783 resultados para Leadership prototype


Relevância:

20.00% 20.00%

Publicador:

Resumo:

We have designed, built, and tested an early prototype of a novel subxiphoid access system intended to facilitate epicardial electrophysiology, but with possible applications elsewhere in the body. The present version of the system consists of a commercially available insertion needle, a miniature pressure sensor and interconnect tubing, read-out electronics to monitor the pressures measured during the access procedure, and a host computer with user-interface software. The nominal resolution of the system is <0.1 mmHg, and it has deviations from linearity of <1%. During a pilot series of human clinical studies with this system, as well as in an auxiliary study done with an independent method, we observed that the pericardial space contained pressure-frequency components related to both the heart rate and respiratory rate, while the thorax contained components related only to the respiratory rate, a previously unobserved finding that could facilitate access to the pericardial space. We present and discuss the design principles, details of construction, and performance characteristics of this system.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Gamma and beta radiation emitting radiopharmaceuticals are handled in nuclear medicine services, and in many cases there is only individual monitoring of gamma radiation. In this paper, the results obtained using a wrist dosimeter prototype (CaSO(4):Dy + Teflon pellets) show that the doses for workers occupationally exposed to beta radiation from (153)Sm are not negligible. It is important that this dose is evaluated, and it has to be taken into consideration in the individual monitoring system.

Relevância:

20.00% 20.00%

Publicador:

Relevância:

20.00% 20.00%

Publicador:

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: Aortic valve replacement with a cryopreserved aortic homograft (CH) is an attractive alternative to bioprosthesis implantation. The aim of the study was to compare the hemodynamic performance of CH implanted with aortic root inclusion compared to prototype stentless (SS) bioprosthesis, standard stented (SD) bioprosthesis, and a native aortic valve. Methods: Hemodynamics and Doppler echocardiographic measurements such as left ventricular ejection fraction, aortic valve orifice area index (AVOAI), mean and maximal transvalvular gradients, were obtained at rest and immediately after exercise in 28 patients after aortic valve replacement with CH (n = 10), SS (n = 9), or SD (n = 9), and in a control group (CG) of 15 normal volunteers. Results: Rest and peak exercise heart rate and workload achieved were not different among the groups. Baseline AVOAI was larger for CH and CG compared to SS and SD groups (P < 0.05). Maximal and mean transvalvular pressure gradients at rest were lower for CH compared to SS and SD groups (P < 0.05), but higher than CG (P < 0,05). Conclusion: Implanted aortic CH had better hemodynamic performance than SS and SD bioprosthesis and similar to native normal aortic valves, both at rest and immediately after exercise. (ECHOCARDIOGRAPHY, Volume 26, November 2009).