998 resultados para Large aperture
Resumo:
Spatial resolution in photoacoustic and thermoacoustic tomography is ultrasound transducer (detector) bandwidth limited. For a circular scanning geometry the axial (radial) resolution is not affected by the detector aperture, but the tangential (lateral) resolution is highly dependent on the aperture size, and it is also spatially varying (depending on the location relative to the scanning center). Several approaches have been reported to counter this problem by physically attaching a negative acoustic lens in front of the nonfocused transducer or by using virtual point detectors. Here, we have implemented a modified delay-and-sum reconstruction method, which takes into account the large aperture of the detector, leading to more than fivefold improvement in the tangential resolution in photoacoustic (and thermoacoustic) tomography. Three different types of numerical phantoms were used to validate our reconstruction method. It is also shown that we were able to preserve the shape of the reconstructed objects with the modified algorithm. (C) 2014 Optical Society of America
Resumo:
We present a method of image-speckle contrast for the nonprecalibration measurement of the root-mean-square roughness and the lateral-correlation length of random surfaces with Gaussian correlation. We use the simplified model of the speckle fields produced by the weak scattering object in the theoretical analysis. The explicit mathematical relation shows that the saturation value of the image-speckle contrast at a large aperture radius determines the roughness, while the variation of the contrast with the aperture radius determines the lateral-correlation length. In the experimental performance, we specially fabricate the random surface samples with Gaussian correlation. The square of the image-speckle contrast is measured versus the radius of the aperture in the 4f system, and the roughness and the lateral-correlation length are extracted by fitting the theoretical result to the experimental data. Comparison of the measurement with that by an atomic force microscope shows our method has a satisfying accuracy. (C) 2002 Optical Society of America.
Resumo:
New parasitic lasing suppression techniques are developed and high gain amplification is demonstrated in a petawatt level Ti:sapphire amplifier based on the chirped pulse amplification (CPA) scheme. Cladding the large aperture Ti: sapphire with refractive-index matched liquid doped with absorber suppresses the transverse lasing. The acousto-optic programmable dispersive filter (AOPDF) is used to realize side-lobe suppression in the temporal profile of the compressed pulse. The 800 nm laser output with peak power of 0.89 PW and pulse width of 29.0 fs is demonstrated. (c) 2007 Optical Society of America.
Resumo:
This thesis describes the development of low-noise heterodyne receivers at THz frequencies for submillimeter astronomy using Nb-based superconductor-insulator-superconductor (SIS) tunneling junctions. The mixers utilize a quasi-optical configuration which consists of a planar twin-slot antenna and antisymmetrically-fed two-junctions on an antireflection-coated silicon hyperhemispherical lens. On-chip integrated tuning circuits, in the form of microstrip lines, are used to obtain maximum coupling efficiency in the designed frequency band. To reduce the rf losses in the integrated tuning circuits above the superconducting Nb gap frequency (~ 700 GHz), normal-metal Al is used to replace Nb as the tuning circuits.
To account the rf losses in the micros trip lines, we calculated the surface impedance of the AI films using the nonlocal anomalous skin effect for finite thickness films. Nb films were calculated using the Mattis-Bardeen theory in the extreme anomalous limit. Our calculations show that the losses of the Al and Nb microstrip lines are about equal at 830 GHz. For Al-wiring and Nb-wiring mixers both optimized at 1050 GHz, the RF coupling efficiency of Al-wiring mixer is higher than that of Nb-wiring one by almost 50%. We have designed both Nb-wiring and Al-wiring mixers below and above the gap frequency.
A Fourier transform spectrometer (FTS) has been constructed especially for the study of the frequency response of SIS receivers. This FTS features large aperture size (10 inch) and high frequency resolution (114 MHz). The FTS spectra, obtained using the SIS receivers as direct detectors on the FTS, agree quite well with our theoretical simulations. We have also, for the first time, measured the FTS heterodyne response of an SIS mixer at sufficiently high resolution to resolve the LO and the sidebands. Heterodyne measurements of our SIS receivers with Nb-wiring or Al-wiring have yielded results which arc among the best reported to date for broadband heterodyne receivers. The Nb-wiring mixers, covering 400 - 850 GHz band with four separate fixed-tuned mixers, have uncorrected DSB receiver noise temperature around 5hv/kb to 700 GHz, and better than 540 K at 808 GHz. An Al-wiring mixer designed for 1050 GHz band has an uncorrected DSB receiver noise temperature 840 K at 1042 GHz and 2.5 K bath temperature. Mixer performance analysis shows that Nb junctions can work well up to twice the gap frequency and the major cause of loss above the gap frequency is the rf losses in the microstrip tuning structures. Further advances in THz SIS mixers may be possible using circuits fabricated with higher-gap superconductors such as NbN. However, this will require high-quality films with low RF surface resistance at THz frequencies.
Resumo:
The resolution and classical noise in ghost imaging with a classical thermal light are investigated theoretically. For ghost imaging with a Gaussian Schell model source, the dependences of the resolution and noise on the spatial coherence of the source and the aperture in the imaging system are discussed and demonstrated by using numerical simulations. The results show that an incoherent source and a large aperture will lead to a good image quality and small noise.
Resumo:
We propose a novel highly sensitive wave front detection method for a quick check of a flat wave front by taking advantage of a non-zero-order pi phase plate that yields a non-zero-order diffraction pattern. When a light beam with a flat wave front illuminates a phase plate, the zero-order intensity is zero. When there is a slight distortion of the wave front, the zero-order intensity increases. The ratio of first-order intensity to that of zero-order intensity is used as the criterion with which to judge whether the wave front under test is flat, eliminating the influence of background light. Experimental results demonstrate that this method is efficient, robust, and cost-effective and should be highly interesting for a quick check of a flat wave front of a large-aperture laser beam and adaptive optical systems. (c) 2005 Optical Society of America.
Resumo:
在星间激光通信中,涉及对大口径衍射极限激光波面的检测,为保证测量精度,必须严格控制波面十涉仪镜子的自重和温度变形。采用有限元方法对大型干涉仪镜子在不同支承方式下的表面变形进行了分析,结果表明,接触角为180°的钢带支承是较好的支承方式,反射镜表面变形峰-谷(P-V)值仅为1.35nm,均方根(RMS)值为0.363nm根据这一结论,设计了一个同定支承点与浮动支承相结合的超静定钢带支承结构。在该结构下,分析了镜子轴向、径向、周向的温度梯度效应,分析数据表明,镜子的热弹性变形远大于自重变形,建议采取一定的温控
Resumo:
采用蜗轮蜗杆驱动调整机构、使用同步带安装标准镜片方式、正交十字导轨支撑等可有效提高光学精密检测系统中大口径干涉仪装置的镜面面形质量、稳定性和调节准确度,从理论上介绍了蜗轮蜗杆驱动机构等设计原理及其基本公式,并从实验上验证了这些机构对光学精密检测系统稳定性的影响.
Resumo:
从靶场反射镜架模块的机械结构设计布局所需几何空间的角度出发,根据大口径、列阵器件的特殊要求,给出符合“神光Ⅲ”装置总体技术要求的ICF靶场光束口径与列阵间隔之间的关系,得出靶场△纵、△横应满足的公式.
Resumo:
控制由机械装夹方式所引入的波前畸变以提高惯性约束聚变(ICF)输出光束的质量,是在大口径钕玻璃片主放大器结构设计中必须考虑的。提出了一种新的有限元变形结果与光学元件面形畸变之间的数据处理方式,并与传统方式进行了对比。基于新的数据处理接口,利用光机集成分析方法对大口径八边形钕玻璃片的支撑系统结构设计参数进行优化。优化的结果保证了由支撑系统引起的透过波前畸变小于十分之一波长,同时波前畸变与设计参数变动的相关性最小。
Resumo:
在传统哈特曼检验法基础上研制成功一种扫描型哈特曼检测新装置。可对最大口径为Ф300mm的聚焦镜在全口径范围内进行采样测量。该检测装置由大口径标准平行光管、扫描式哈特曼光阑、被俭聚焦镜、CCD摄像机及计算机组成。在水平和垂直两个径向上开有等间距排列且相互错开半个间距的小孔。并且在步进电机的驱动下绕光轴旋转。可对被检聚焦镜进行全口径连续采样。对有效口径为夺154mm的斐索平面干涉仪非球面准直物镜的球差及焦斑能量集中度进行了测量。进而由球差计算得到了波像差。并用干涉法对该准直物镜进行了测量。球差的理论值与测量值
Resumo:
El nuevo modelo de e-colaboración científica y e-producción de conocimiento imponen el registro, catalogación y la preservación distribuida de grandes volúmenes de datos. Su posterior análisis y el conocimiento que de ellos emerja se logrará mediante de técnicas de minería de datos, las cuales dependerán, en gran medida , los mecanismos de almacenamiento y catalogación utilizado. Por ello, cada vez más y con más frecuencia, las comunidades virtuales de investigación requieren de ambientes de e-colaboración y e-investigación centrados en los datos. LAGOVirtual es un proyecto en fase de desarrollo el cual tiene como objetivo final establecer una plataforma de colaboración para el Large Aperture Gamma Ray Burst Observatory (LAGO). Este observatorio continental está diseñado para la detección de componentes de alta energía de rayos gamma, mediante la utilización de detectores Cherenkov de agua, ubicados en sitios de alta montaña (Chacaltaya-Bolivia, 5300 m.s.n.m, Pico Espejo-Venezuela, 4750 m.s.n.m., Sierra Negra- Mexico, 4650 m.s.n.m., Marcapomacocha-Peru, 4600 m.s.n.m). Esta plataforma de colaboración utiliza como para un repositorio DSpace adaptado para la preservación y diseminación de los datos registrados en cada una de las instalaciones. DSpace ha sido modificado aprovechando su estructura jerárquica, creando como comunidades principales a los países miembros del proyecto, seguido por subcomunidades, conformadas por las diferentes instituciones y tipo de investigación. Los datos adquiridos por los detectores Cherenkov, son almacenados y catalogados dentro de esta estructura, igualmente, se almacenan los datos de análisis (datos de los instrumentos, gráficos, datos post-procesados, etc.) asociados, manteniendo un vínculo entre ellos dentro del repositorio.Esta contribución tiene por objeto, además de las tendencias de distintas comunidades para la preservación de datos a través de repositorios, mostrar los detalles de la implantación particular para LAGO DSpace.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
This paper presents an ultrasonic method to measure small concentrations of water in lubricating oil. It uses an ultrasonic measurement cell composed by a piezoceramic emitter (5 and 10 MHz), and a large aperture PVDF receiver that eliminates diffraction effects. The propagation velocity, attenuation coefficient and density of several samples of water-in-oil emulsion were measured. The concentrations of water of the samples were in the range of 0 to 5% in volume, and the results showed that these low concentrations can be discriminated within a resolution of 0.2% in the studied range, using the measurement of the propagation velocity.
Resumo:
This work describes the use of a large aperture PVDF receiver in the measurement of density of liquids and elastic constants of composite materials. The density measurement of several liquids is obtained with the accuracy of less than 0.2% using a conventional NDT emitter transducer and a 70-mm diameter, 52-μm P(VDF-TrFE) membrane with gold electrodes. The determination of the elastic constants of composite materials is based in the measurement of phase velocity. It is shown that the diffraction can lead to errors around 1% in the velocity measurement when using a pair of ultrasonic transducers (1MHz and 19mm diameter) operating in transmission-reception mode separated by a distance of 100 mm. This effect is negligible when using a pair of 10-MHz transducers. On the other hand, the dispersion at 10 MHz can result in errors of about 0.5%, measuring the velocity in composite materials. The use of an 80-mm diameter, 52-μm thick PVDF membrane receiver allows measuring the phase velocity without the diffraction effects.