999 resultados para Intensity points


Relevância:

30.00% 30.00%

Publicador:

Resumo:

The spatial variation of chromospheric oscillations in network bright points (NBPs) is studied using high-resolution observations in Ca II K3. Light curves and hence power spectra were created by isolating distinct regions of the NBP via a simple intensity thresholding technique. Using this technique, it was possible to identify peaks in the power spectra with particular spatial positions within the NBPs. In particular, long-period waves with periods of 4-15 minutes (1-4 mHz) were found in the central portions of each NBP, indicating that these waves are certainly not acoustic but possibly due to magnetoacoustic or magnetogravity wave modes. We also show that spatially averaged or low spatial resolution power spectra can lead to an inability to detect such long-period waves.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Magnetic bright points (MBPs) in the internetwork are among the smallest objects in the solar photosphere and appear bright against the ambient environment. An algorithm is presented that can be used for the automated detection of the MBPs in the spatial and temporal domains. The algorithm works by mapping the lanes through intensity thresholding. A compass search, combined with a study of the intensity gradient across the detected objects, allows the disentanglement of MBPs from bright pixels within the granules. Object growing is implemented to account for any pixels that might have been removed when mapping the lanes. The images are stabilized by locating long-lived objects that may have been missed due to variable light levels and seeing quality. Tests of the algorithm, employing data taken with the Swedish Solar Telescope, reveal that approximate to 90 per cent of MBPs within a 75 x 75 arcsec(2) field of view are detected.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

High-cadence, multiwavelength, optical observations of solar magnetic bright points (MBPs), captured at the disk center using the ROSA and IBIS imaging systems on the Dunn Solar Telescope, are presented. MBPs manifesting in the Na I D-1 core are found to preferentially exist in regions containing strong downflows, in addition to cospatial underlying photospheric magnetic field concentrations. Downdrafts within Na I D-1 bright points exhibit speeds of up to 7 km s(-1), with preferred structural symmetry in intensity, magnetic field, and velocity profiles about the bright point center. Excess intensities associated with G-band and Ca II K observations of MBPs reveal a power-law trend when plotted as a function of the magnetic flux density. However, Na I D-1 observations of the same magnetic features indicate an intensity plateau at weak magnetic field strengths below approximate to 150 G, suggesting the presence of a two-component heating process: one which is primarily acoustic and the other predominantly magnetic. We suggest that this finding is related to the physical expansion of magnetic flux tubes, with weak field strengths (approximate to 50 G) expanding by similar to 76%, compared to a similar to 44% expansion when higher field strengths (approximate to 150 G) are present. These observations provide the first experimental evidence of rapid downdrafts in Na I D-1 MBPs and reveal the nature of a previously unresolved intensity plateau associated with these structures.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Magnetic bright points (MBPs) are among the smallest observable objects on the solar photosphere. A combination of G-band observations and numerical simulations is used to determine their area distribution. An automatic detection algorithm, employing one-dimensional intensity profiling, is utilized to identify these structures in the observed and simulated data sets. Both distributions peak at an area of approximate to 45,000 km(2), with a sharp decrease toward smaller areas. The distributions conform with log-normal statistics, which suggests that flux fragmentation dominates over flux convergence. Radiative magneto-convection simulations indicate an independence in the MBP area distribution for differing magnetic flux densities. The most commonly occurring bright point size corresponds to the typical width of inter-granular lanes.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Purpose: The aim of this work was to determine if volumetric modulated arc therapy (VMAT) plans, created for constant dose-rate (cdrVMAT) delivery are a viable alternative to step and shoot five-field intensity modulated radiation therapy (IMRT). Materials and methods: The cdrVMAT plans, inverse planned on a treatment planning system with no solution to account for couch top or rails, were created for delivery on a linear accelerator with no variable dose rate control system. A series of five-field IMRT and cdrVMAT plans were created using dual partial arcs (gantry rotating between 260° and 100°) with 4° control points for ten prostate patients with the average rectal constraint incrementally increased. Pareto fronts were compared for the planning target volume homogeneity and average rectal dose between the two techniques for each patient. Also investigated were tumour control probability and normal tissue complication probability values for each technique. The delivery parameters [monitor units (MU) and time] and delivery accuracy of the IMRT and VMAT plans were also compared. Results: Pareto fronts showed that the dual partial arc plans were superior to the five-field IMRT plans, particularly for the clinically acceptable plans where average rectal doses were less for rotational plans (p = 0·009) with no statistical difference in target homogeneity. The cdrVMAT plans had significantly more MU (p = 0·005) but the average delivery time was significantly less than the IMRT plans by 42%. All clinically acceptable cdrVMAT plans were accurate in their delivery (gamma 99·2 ± 1·1%, 3%3 mm criteria). Conclusions Accurate delivery of dual partial arc cdrVMAT avoiding the couch top and rails has been demonstrated.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Introduction The majority of stage III patients with non-small cell lung cancer (NSCLC) are unsuitable for concurrent chemoradiotherapy, the non-surgical gold standard of care. As the alternative treatment options of sequential chemoradiotherapy and radiotherapy alone are associated with high local failure rates, various intensification strategies have been employed. There is evidence to suggest that altered fractionation using hyperfractionation, acceleration, dose escalation, and individualisation may be of benefit. The MAASTRO group have pioneered the concept of ‘isotoxic’ radiotherapy allowing for individualised dose escalation using hyperfractionated accelerated radiotherapy based on predefined normal tissue constraints. This study aims to evaluate whether delivering isotoxic radiotherapy using intensity modulated radiotherapy (IMRT) is achievable.

Methods and analysis Isotoxic IMRT is a multicentre feasibility study. From June 2014, a total of 35 patients from 7 UK centres, with a proven histological or cytological diagnosis of inoperable NSCLC, unsuitable for concurrent chemoradiotherapy will be recruited. A minimum of 2 cycles of induction chemotherapy is mandated before starting isotoxic radiotherapy. The dose of radiation will be increased until one or more of the organs at risk tolerance or the maximum dose of 79.2 Gy is reached. The primary end point is feasibility, with accrual rates, local control and overall survival our secondary end points. Patients will be followed up for 5 years.

Ethics and dissemination The study has received ethical approval (REC reference: 13/NW/0480) from the National Research Ethics Service (NRES) Committee North West—Greater Manchester South. The trial is conducted in accordance with the Declaration of Helsinki and Good Clinical Practice (GCP). The trial results will be published in a peer-reviewed journal and presented internationally.

Trial registration number NCT01836692; Pre-results.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

La relation mère-enfant est une variable déterminante de l’adaptation de l’enfant exposé à la violence conjugale. Toutefois, les rares études qui analysent simultanément le point de vue de la mère et celui de l’enfant au sujet de la qualité de leur relation révèlent peu de liens entre eux. La présente étude vise à identifier les variables associées à l’écart dans l’évaluation que la mère et l’enfant victimes de violence conjugale font de la qualité de leur relation. Au total, 117 mères victimes de violence conjugale et leur enfant âgé entre 8 et 12 ans ont participé à l’étude. Conformément aux hypothèses, plusieurs variables déjà liées à la qualité de la relation mère-enfant en contexte de violence conjugale sont associées aux différences de points de vue. C’est le cas pour les troubles extériorisés de l’enfant, son degré de parentification, la détresse de la mère et les troubles intériorisés de l’enfant. En revanche, l’intensité de la violence conjugale, la présence d’abus physique et le sexe de l’enfant ne prédisent pas de manière significative les écarts de point de vue entre la mère et l’enfant. La discussion montre l’intérêt de prendre en compte non seulement le point de vue de la mère et celui de l’enfant à propos de leur relation mais également leurs écarts de point de vue et les facteurs qui y contribuent.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Nurse Managers need today more than ever instruments that can be used to justify the billions of dollars that are invested in the healthcare sector annually. The objective of the study was to establish the validity and reliability of the Nursing Intensity Critical Care Questionnaire (NICCQ) in a cardiac surgery intensive care unit (CSICU) of a tertiary hospital. An expert panel evaluated the questionnaire’s content validity while generalizability theory was used to estimate the G and D coefficients. Decision studies enabled the investigators to determine if the current ward functioning of having one nurse rate one patient is adequate. Also, exploratory factorial analyses (EFA) preceded by principal component analyses (PCA) looked at establishing the factorial structure for the NICCQ. Finally, the NICCQ was correlated with a severity of illness score known as the Acute Physiology And Chronic Health Evaluation II (APACHE II) to estimate the correlation between patient illness and nursing intensity of care. The NICCQ was used by nurses using a sample of patients who had undergone cardiac surgery and were hospitalized on a CSICU of a tertiary teaching hospital. A convenience sample of nurses and patients on the CSICU was used to reflect the procedures and usual functioning of the unit. Each item on the questionnaire measured nursing intensity of care using a three point ordinal scale (Light, Moderate, and Severe) for the first 11 items, and a five point ordinal scale for the global assessment item (including the intermediate categories light/moderate and moderate/severe). The questionnaire proved to be both valid and able to be generalized to all nurses working in the CSICU. Overall results showed that 94.4% of the item generalizability coefficients indicated acceptable to excellent reliability, with most (86.1%) being larger than .90. The EFA established a simple 4 factor structure that explained little of the variance (32%). A correlation coefficient of 0.36 indicated that patient’ severity of illness is somewhat correlated with nursing intensity of care. The study showed that the NICCQ is a valid questionnaire with a generalizability coefficient that is large enough to be used by nurses’ managers for administrative purposes. Further research using larger samples would be needed to further test the factor structure of the NICCQ.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

In this paper we discuss current work concerning Appearance-based and CAD-based vision; two opposing vision strategies. CAD-based vision is geometry based, reliant on having complete object centred models. Appearance-based vision builds view dependent models from training images. Existing CAD-based vision systems that work with intensity images have all used one and zero dimensional features, for example lines, arcs, points and corners. We describe a system we have developed for combining these two strategies. Geometric models are extracted from a commercial CAD library of industry standard parts. Surface appearance characteristics are then learnt automatically by observing actual object instances. This information is combined with geometric information and is used in hypothesis evaluation. This augmented description improves the systems robustness to texture, specularities and other artifacts which are hard to model with geometry alone, whilst maintaining the advantages of a geometric description.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Our aim was to investigate the immediate effects of bilateral, 830 nm, low-level laser therapy (LLLT) on high-intensity exercise and biochemical markers of skeletal muscle recovery, in a randomised, double-blind, placebo-controlled, crossover trial set in a sports physiotherapy clinic. Twenty male athletes (nine professional volleyball players and eleven adolescent soccer players) participated. Active LLLT (830 nm wavelength, 100 mW, spot size 0.0028 cm(2), 3-4 J per point) or an identical placebo LLLT was delivered to five points in the rectus femoris muscle (bilaterally). The main outcome measures were the work performed in the Wingate test: 30 s of maximum cycling with a load of 7.5% of body weight, and the measurement of blood lactate (BL) and creatine kinase (CK) levels before and after exercise. There was no significant difference in the work performed during the Wingate test (P > 0.05) between subjects given active LLLT and those given placebo LLLT. For volleyball athletes, the change in CK levels from before to after the exercise test was significantly lower (P = 0.0133) for those given active LLLT (2.52 U l(-1) +/- 7.04 U l(-1)) than for those given placebo LLLT (28.49 U l(-1) +/- 22.62 U l(-1)). For the soccer athletes, the change in blood lactate levels from before exercise to 15 min after exercise was significantly lower (P < 0.01) in the group subjected to active LLLT (8.55 mmol l(-1) +/- 2.14 mmol l(-1)) than in the group subjected to placebo LLLT (10.52 mmol l(-1) +/- 1.82 mmol l(-1)). LLLT irradiation before the Wingate test seemed to inhibit an expected post-exercise increase in CK level and to accelerate post-exercise lactate removal without affecting test performance. These findings suggest that LLLT may be of benefit in accelerating post-exercise recovery.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

In the last years, phototherapy has becoming a promising tool to improve skeletal muscle recovery after exercise, however, it was not compared with other modalities commonly used with this aim. In the present study we compared the short-term effects of cold water immersion therapy (CWIT) and light emitting diode therapy (LEDT) with placebo LEDT on biochemical markers related to skeletal muscle recovery after high-intensity exercise. A randomized double-blind placebo-controlled crossover trial was performed with six male young futsal athletes. They were treated with CWIT (5A degrees C of temperature [SD +/- 1A degrees]), active LEDT (69 LEDs with wavelengths 660/850 nm, 10/30 mW of output power, 30 s of irradiation time per point, and 41.7 J of total energy irradiated per point, total of ten points irradiated) or an identical placebo LEDT 5 min after each of three Wingate cycle tests. Pre-exercise, post-exercise, and post-treatment measurements were taken of blood lactate levels, creatine kinase (CK) activity, and C-reactive protein (CRP) levels. There were no significant differences in the work performed during the three Wingate tests (p > 0.05). All biochemical parameters increased from baseline values (p < 0.05) after the three exercise tests, but only active LEDT decreased blood lactate levels (p = 0.0065) and CK activity (p = 0.0044) significantly after treatment. There were no significant differences in CRP values after treatments. We concluded that treating the leg muscles with LEDT 5 min after the Wingate cycle test seemed to inhibit the expected post-exercise increase in blood lactate levels and CK activity. This suggests that LEDT has better potential than 5 min of CWIT for improving short-term post-exercise recovery.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The aim of this study was to investigate the mechanisms whereby low-intensity laser therapy may affect the severity of oral mucositis. A hamster cheek pouch model of oral mucositis was used with all animals receiving intraperitoneal 5-fluorouracil followed by surface irritation. Animals were randomly allocated into three groups and treated with a 35 mW laser, 100 mW laser, or no laser. Clinical severity of mucositis was assessed at four time-points by a blinded examiner. Buccal pouch tissue was harvested from a subgroup of animals in each group at four time-points. This tissue was used for immunohistochemistry for cyclooxygenase-2 (COX-2), vascular endothelial growth factor (VEGF), and factor VIII (marker of microvessel density) and the resulting staining was quantified. Peak severity of mucositis was reduced in the 35 mW laser group as compared to the 100 mW laser and control groups. This reduced peak clinical severity of mucositis in the 35 mW laser group was accompanied by a significantly lower level of COX-2 staining. The 100 mW laser did not have an effect on the severity of clinical mucositis, but was associated with a decrease in VEGF levels at the later time-points, as compared to the other groups. There was no clear relationship of VEGF levels or microvessel density to clinical mucositis severity. The tissue response to laser therapy appears to vary by dose. Low-intensity laser therapy appears to reduce the severity of mucositis, at least in part, by reducing COX-2 levels and associated inhibition of the inflammatory response.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Detection thresholds and psychophysical curves were established for caffeine, quinine-HCl (QHCl), and propylthiouracil (PROP) in a sample of 33 subjects (28 female mean age 24 ± 4). The mean detection threshold (±standard error) for caffeine, QHCl, and PROP was 1.2 ± 0.12, 0.0083 ± 0.001, and 0.088 ± 0.07 mM, respectively. Pearson product–moment analysis revealed no significant correlations between detection thresholds of the compounds. Psychophysical curves were constructed for each bitter compound over 6 concentrations. There were significant correlations between incremental points of the individual psychophysical curves for QHCl and PROP. Regarding caffeine, there was a specific concentration (6 mM) below and above which the incremental steps in bitterness were correlated. Between compounds, analysis of psychophysical curves revealed no correlations with PROP, but there were significant correlations between the bitterness of caffeine and QHCl at higher concentrations on the psychophysical curve (P < 0.05). Correlation analysis of detection threshold and suprathreshold intensity within a compound revealed a significant correlation between PROP threshold and suprathreshold intensity (r = 0.46–0.4, P < 0.05), a significant negative correlation for QHCl (r = –0.33 to –0.4, P < 0.05), and no correlation for caffeine. The results suggest a complex relationship between chemical concentration, detection threshold, and suprathreshold intensity.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Purpose

To test a field-based protocol using intermittent activities representative of children's physical activity behaviours, to generate behaviourally valid, population-specific accelerometer cut-points for sedentary behaviour, moderate, and vigorous physical activity.
Methods

Twenty-eight children (46% boys) aged 10–11 years wore a hip-mounted uniaxial GT1M ActiGraph and engaged in 6 activities representative of children's play. A validated direct observation protocol was used as the criterion measure of physical activity. Receiver Operating Characteristics (ROC) curve analyses were conducted with four semi-structured activities to determine the accelerometer cut-points. To examine classification differences, cut-points were cross-validated with free-play and DVD viewing activities.
Results

Cut-points of ≤372, >2160 and >4806 counts•min−1 representing sedentary, moderate and vigorous intensity thresholds, respectively, provided the optimal balance between the related needs for sensitivity (accurately detecting activity) and specificity (limiting misclassification of the activity). Cross-validation data demonstrated that these values yielded the best overall kappa scores (0.97; 0.71; 0.62), and a high classification agreement (98.6%; 89.0%; 87.2%), respectively. Specificity values of 96–97% showed that the developed cut-points accurately detected physical activity, and sensitivity values (89–99%) indicated that minutes of activity were seldom incorrectly classified as inactivity.
Conclusion

The development of an inexpensive and replicable field-based protocol to generate behaviourally valid and population-specific accelerometer cut-points may improve the classification of physical activity levels in children, which could enhance subsequent intervention and observational studies.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Actigraph accelerometers are hypothesized to be valid measurements for assessing children's sedentary time. However, there is considerable variation in accelerometer cut-points used. Therefore, we compared the most common accelerometer sedentary cut-points of children performing sedentary behaviors. Actigraph Actitrainer uniaxial accelerometers were used to measure children's activity intensity (29 children, 5-11 years old) during different activities, namely playing computer games, nonelectronic sedentary games, watching television and playing outdoors. A structured protocol was the criterion for assessing the validity of four common cut-points (100, 300, 800, 1100 counts/minute). The median counts during all sedentary behaviors were below the lowest comparison cut-point of 100 cpm. The 75th percentile values for the sedentary behaviors were always below the cut-point of 300 cpm. Our results suggest that the cut-point of <100 cpm is the most appropriate.