923 resultados para Input impedance
Resumo:
Analytical expressions for the Green’s function of an annular elliptical ring microstrip antenna (AERMA) are developed and reported. The modal, radiation and input impedance characteristics of the TM, modes are determined from these expressions. The resonant frequencies of odd modes are greater than that of the even modes for all TMnl modes (n = 1, 2, 3, ...) udke elliptical microstrip structures. The radiation pattern and input imedance curves of TMI2 mode on comparison with available experimental result shows good agreement whch provides an independent validation to this technique. The performance of the AERMA is then investigated as a function of thickness and substrate dielectric permittivity.
Resumo:
A highly stable microvolt amplifier for use with atmospheric broadband thermopile radiometers is described. The amplifier has a nominal gain of 500, for bipolar input signals in the range +/- 10 mV from a floating source. The noise level at the input is less than 5 mu V (at 100 k Omega input impedance), permitting instantaneous diffuse solar radiation measurements to 0.5 W m(-2) resolution with 12 bit analog to digital conversion. The temperature stability of gain is better than 5 ppm/degrees C (-4 to 20 degrees C). Averaged over a decade of use, the long term drift of the amplifier gain is less than similar to 0.02%/yr. As well as radiometers measuring solar and terrestrial radiations, the amplifier has also been successfully used with low level signals from thermocouples and ground heat flux plates.
Resumo:
The frequency responses of two 50 Hz and one 400 Hz induction machines have been measured experimentally over a frequency range of 1 kHz to 400 kHz. This study has shown that the stator impedances of the machines behave in a similar manner to a parallel resonant circuit, and hence have a resonant point at which the Input impedance of the machine is at a maximum. This maximum impedance point was found experimentally to be as low as 33 kHz, which is well within the switching frequency ranges of modern inverter drives. This paper investigates the possibility of exploiting the maximum impedance point of the machine, by taking it into consideration when designing an inverter, in order to minimize ripple currents due to the switching frequency. Minimization of the ripple currents would reduce torque pulsation and losses, increasing overall performance. A modified machine model was developed to take into account the resonant point, and this model was then simulated with an inverter to demonstrate the possible advantages of matching the inverter switching frequency to the resonant point. Finally, in order to experimentally verify the simulated results, a real inverter with a variable switching frequency was used to drive an induction machine. Experimental results are presented.
Resumo:
In magnetic resonance imaging (MRI), either on human or animal studies, the main requirements for radiofrequency (RF) coils are to produce a homogeneous RF field while used as a transmitter coil and to have the best signal-to-noise ratio (SNR) while used as a receiver. Besides, they need to be easily frequency adjustable and have input impedance matching 50 Omega to several different load conditions. New theoretical and practical concepts are presented here for considerable enhancing of RF coil homogeneity for MRI experiments on small animals. To optimize field homogeneity, we have performed simulations using Blot and Savart law varying the coil`s window angle, achieving the optimum one. However, when the coil`s dimensions are the same order of the wave length and according to transmission line theory, differences in electrical length and effects of mutual inductances between adjacent strip conductors decrease both field homogeneity and SNR. The problematic interactions between strip conductors by means of mutual inductance were eliminated by inserting crossings at half electrical length, avoiding distortion on current density, thus eliminating sources of field inhomogeneity. Experimental results show that measured field maps and simulations are in good agreement. The new coil design, dubbed double-crossed saddle described here have field homogeneity and SNR superior than the linearly driven 8-rung birdcage coil. One of our major findings was that the effects of mutual inductance are more significant than differences in electrical length for this frequency and coil dimensions. In vitro images of a primate Cebus paela brain were acquired, confirming double-crossed saddle superiority. (C) 2010 Wiley Periodicals, Inc. Concepts Magn Reson Part B (Magn Reson Engineering) 37B: 193-201, 2010
Resumo:
In recent years, the radio frequency identification technology (RFID) has gained great interest both industrial communities as scientific communities. Its ability to locate and monitor objects, animals and persons with active or passive tags allows easy development, with good cost-benefice and still presents undeniable benefits in applications ranging from logistics to healthcare, robotics, security, among others. Within this aspect what else comes excelling are RFID tags and the antennas used in RFID readers. Most tags have antennas omnidirectional and are usually manufactured as dipoles modified printed. The primary purpose of a project of antenna for tag is to achieve the required input impedance to perform a good marriage impedance with the load impedance of the chip. Already the objective principal in project of antennas for readers is to achieve reduced sizes and structures with good data transmission capacity. This work brings the numerical characterization of antennas for RFID applications, being these divided into tags RFID and antennas for RFID readers. Three tags RFID and two antennas for RFID readers, found in literature, are analyzed. The analysis of these structures is made using the Method of Waves - WCIP. Initial results found in the literature are compared with those obtained through simulations in WCIP with objective to show that the Method of Waves is able to analyze such structures. To illustrate the results obtained in simulations is presented the behavior of electric and magnetic fields. It also performed a literature review on the characteristics and principles of RFID technology. Suggestions for continuity to this work are presented
Resumo:
Foram realizadas medidas em laboratório da condutividade elétrica complexa de 28 amostras de testemunhos de sondagem de três furos da área MM1-Alvo 1, Distrito dos Carajás, com o objetivo de auxiliar na interpretação de dados geofísicos de campo, obtidos com os métodos polarização induzida/resistividade e eletromagnético/AFMAG, aplicados na área. As medidas foram tomadas no intervalo de frequências de 10-3Hz a 104Hz, medindo-se a amplitude e a fase da condutância. O método empregado foi o de medida direta de impedância, utilizando-se um osciloscópio com memória, um gerador de sinais e dois pré-amplificadores diferenciais com alta impedância de entrada. O sistema de eletrodos escolhido para realizar as medidas foi o de 2 eletrodos de platina-platinizada em virtude de sua resposta de frequência ser plana no intervalo utilizado. Todas as medidas foram realizadas à temperatura constante de 24°C ± 1°C. Para interpretar as medidas de condutividade foi realizado estudo petrográfico das amostras, utilizando-se lâminas delgadas, seções polidas e difração de Raios-X. Foi determinado o teor de cobre, sob a forma de sulfeto, nas amostras utilizando-se o método de absorção atômica. Os resultados petrográficos permitiram classificar as amostras em cinco grupos distintos: granito, biotita-xisto, anfibolito, anfibólio-xisto e quartzito ferruginoso-formação ferrífera. O teor de cobre foi variável nos cinco grupos, havendo teores desde 50ppm até 6000ppm. Nas medidas de condutividade observou-se que, dentre os cinco grupos, as amostras da formação ferrífera apresentaram as maiores variações com a frequência. As amostras de granito tiveram espectro mais plano que as dos xistos e anfibolito. A conclusão a que se chegou é que as anomalias eletromagnéticas e de polarização induzida/resistividade observadas no campo próximo aos três furos (F1, F2, F3) são devidas principalmgnte a formação ferrífera magnetitica, a secundariamente à mineralização de baixo teor de calcopirita associada.
Resumo:
This work is structured as follows: In Section 1 we discuss the clinical problem of heart failure. In particular, we present the phenomenon known as ventricular mechanical dyssynchrony: its impact on cardiac function, the therapy for its treatment and the methods for its quantification. Specifically, we describe the conductance catheter and its use for the measurement of dyssynchrony. At the end of the Section 1, we propose a new set of indexes to quantify the dyssynchrony that are studied and validated thereafter. In Section 2 we describe the studies carried out in this work: we report the experimental protocols, we present and discuss the results obtained. Finally, we report the overall conclusions drawn from this work and we try to envisage future works and possible clinical applications of our results. Ancillary studies that were carried out during this work mainly to investigate several aspects of cardiac resynchronization therapy (CRT) are mentioned in Appendix. -------- Ventricular mechanical dyssynchrony plays a regulating role already in normal physiology but is especially important in pathological conditions, such as hypertrophy, ischemia, infarction, or heart failure (Chapter 1,2.). Several prospective randomized controlled trials supported the clinical efficacy and safety of cardiac resynchronization therapy (CRT) in patients with moderate or severe heart failure and ventricular dyssynchrony. CRT resynchronizes ventricular contraction by simultaneous pacing of both left and right ventricle (biventricular pacing) (Chapter 1.). Currently, the conductance catheter method has been used extensively to assess global systolic and diastolic ventricular function and, more recently, the ability of this instrument to pick-up multiple segmental volume signals has been used to quantify mechanical ventricular dyssynchrony. Specifically, novel indexes based on volume signals acquired with the conductance catheter were introduced to quantify dyssynchrony (Chapter 3,4.). Present work was aimed to describe the characteristics of the conductancevolume signals, to investigate the performance of the indexes of ventricular dyssynchrony described in literature and to introduce and validate improved dyssynchrony indexes. Morevoer, using the conductance catheter method and the new indexes, the clinical problem of the ventricular pacing site optimization was addressed and the measurement protocol to adopt for hemodynamic tests on cardiac pacing was investigated. In accordance to the aims of the work, in addition to the classical time-domain parameters, a new set of indexes has been extracted, based on coherent averaging procedure and on spectral and cross-spectral analysis (Chapter 4.). Our analyses were carried out on patients with indications for electrophysiologic study or device implantation (Chapter 5.). For the first time, besides patients with heart failure, indexes of mechanical dyssynchrony based on conductance catheter were extracted and studied in a population of patients with preserved ventricular function, providing information on the normal range of such a kind of values. By performing a frequency domain analysis and by applying an optimized coherent averaging procedure (Chapter 6.a.), we were able to describe some characteristics of the conductance-volume signals (Chapter 6.b.). We unmasked the presence of considerable beat-to-beat variations in dyssynchrony that seemed more frequent in patients with ventricular dysfunction and to play a role in discriminating patients. These non-recurrent mechanical ventricular non-uniformities are probably the expression of the substantial beat-to-beat hemodynamic variations, often associated with heart failure and due to cardiopulmonary interaction and conduction disturbances. We investigated how the coherent averaging procedure may affect or refine the conductance based indexes; in addition, we proposed and tested a new set of indexes which quantify the non-periodic components of the volume signals. Using the new set of indexes we studied the acute effects of the CRT and the right ventricular pacing, in patients with heart failure and patients with preserved ventricular function. In the overall population we observed a correlation between the hemodynamic changes induced by the pacing and the indexes of dyssynchrony, and this may have practical implications for hemodynamic-guided device implantation. The optimal ventricular pacing site for patients with conventional indications for pacing remains controversial. The majority of them do not meet current clinical indications for CRT pacing. Thus, we carried out an analysis to compare the impact of several ventricular pacing sites on global and regional ventricular function and dyssynchrony (Chapter 6.c.). We observed that right ventricular pacing worsens cardiac function in patients with and without ventricular dysfunction unless the pacing site is optimized. CRT preserves left ventricular function in patients with normal ejection fraction and improves function in patients with poor ejection fraction despite no clinical indication for CRT. Moreover, the analysis of the results obtained using new indexes of regional dyssynchrony, suggests that pacing site may influence overall global ventricular function depending on its relative effects on regional function and synchrony. Another clinical problem that has been investigated in this work is the optimal right ventricular lead location for CRT (Chapter 6.d.). Similarly to the previous analysis, using novel parameters describing local synchrony and efficiency, we tested the hypothesis and we demonstrated that biventricular pacing with alternative right ventricular pacing sites produces acute improvement of ventricular systolic function and improves mechanical synchrony when compared to standard right ventricular pacing. Although no specific right ventricular location was shown to be superior during CRT, the right ventricular pacing site that produced the optimal acute hemodynamic response varied between patients. Acute hemodynamic effects of cardiac pacing are conventionally evaluated after stabilization episodes. The applied duration of stabilization periods in most cardiac pacing studies varied considerably. With an ad hoc protocol (Chapter 6.e.) and indexes of mechanical dyssynchrony derived by conductance catheter we demonstrated that the usage of stabilization periods during evaluation of cardiac pacing may mask early changes in systolic and diastolic intra-ventricular dyssynchrony. In fact, at the onset of ventricular pacing, the main dyssynchrony and ventricular performance changes occur within a 10s time span, initiated by the changes in ventricular mechanical dyssynchrony induced by aberrant conduction and followed by a partial or even complete recovery. It was already demonstrated in normal animals that ventricular mechanical dyssynchrony may act as a physiologic modulator of cardiac performance together with heart rate, contractile state, preload and afterload. The present observation, which shows the compensatory mechanism of mechanical dyssynchrony, suggests that ventricular dyssynchrony may be regarded as an intrinsic cardiac property, with baseline dyssynchrony at increased level in heart failure patients. To make available an independent system for cardiac output estimation, in order to confirm the results obtained with conductance volume method, we developed and validated a novel technique to apply the Modelflow method (a method that derives an aortic flow waveform from arterial pressure by simulation of a non-linear three-element aortic input impedance model, Wesseling et al. 1993) to the left ventricular pressure signal, instead of the arterial pressure used in the classical approach (Chapter 7.). The results confirmed that in patients without valve abnormalities, undergoing conductance catheter evaluations, the continuous monitoring of cardiac output using the intra-ventricular pressure signal is reliable. Thus, cardiac output can be monitored quantitatively and continuously with a simple and low-cost method. During this work, additional studies were carried out to investigate several areas of uncertainty of CRT. The results of these studies are briefly presented in Appendix: the long-term survival in patients treated with CRT in clinical practice, the effects of CRT in patients with mild symptoms of heart failure and in very old patients, the limited thoracotomy as a second choice alternative to transvenous implant for CRT delivery, the evolution and prognostic significance of diastolic filling pattern in CRT, the selection of candidates to CRT with echocardiographic criteria and the prediction of response to the therapy.
Resumo:
Respiratory system input impedance (Zrs) at low to medium frequencies below 100 Hz, and study of its volume dependence, have been used extensively to quantify airway and tissue mechanics. Zrs at high oscillation frequencies including the first antiresonant frequency (far,1) may contain important information about airway mechanics. Changes in high-frequency Zrs with lung volume have not been studied. The volume-dependent behavior of high-frequency Zrs, specifically far,1 and respiratory system resistance at first antiresonance (Rrs(far,1)), was characterized in 16 healthy adults. Zrs was measured with a forced oscillation signal (5-302.5 Hz) through a wavetube setup. To track Zrs, subjects performed slow deep inspiratory and expiratory maneuvers over 30-s measurements, during which average impedance was calculated over 0.4-s intervals, with successive overlapping estimates every 0.156 s. Flow was measured using a pneumotachometer and integrated to obtain volume. Transpulmonary pressure dependence (Ptp) of Zrs was separately determined in five subjects. Both far,1 and Rrs(far,1) decreased with increasing lung volume and Ptp, consistent with an increase in airway caliber and decreased airway wall compliance as volume increased. These characterizations provide insight into airway mechanics, and are furthermore a necessary first step toward determining whether volume dependence of the first antiresonance is altered in disease.
Resumo:
This paper presents the first analysis of the input impedance and radiation properties of a dipole antenna, placed on top of Fan 's three-dimensional electromagnetic bandgap (EBG) structure, (Applied Physics Letters, 1994) constructed using a high dielectric constant ceramic. The best position of the dipole on the EBG surface is determined following impedance and radiation pattern analyses. Based on this optimum configuration an integrated Schottky heterodyne detector was designed, manufactured and tested from 0.48 to 0.52 THz. The main antenna features were not degraded by the high dielectric constant substrate due to the use of the EBG approach. Measured radiation patterns are in good agreement with the predicted ones.
Resumo:
The cutoff frequencies of an EMI filter are normally given by the noise attenuation requirements the filter has to fulfill. In order to select the component values of the filter elements, i.e. inductances and capacitances, an additional design criterium is needed. In this paper the effect of the EMI filter input and output impedances are considered. The input impedance influences the filters effect on the system displacement power factor and the output impedance plays a key role in the system stability. The effect of filter element values, the number of filter stages as well as additional damping networks are considered and a design procedure is provided. For this analysis a two-port description of the input filters employing ABCD-parameters is used.
Resumo:
The transient response of a system of independent electrodes buried in a semi-infinite conducting medium is studied. Using a simple and versatile numerical scheme written by the authors and based on the Electric Field Integral Equation (EFIE), the effect caused by harmonic signals ranging on frequency from Hz to hundred of MHz, and also by lightning type driving signal striking at a remote point far from the conductors, is extensively studied. The value of the scalar potential appearing on the electrodes as a function of the frequency of the applied signal is one of the variables investigated. Other features such as the input impedance at the injection point of the signal and the Ground Potential Rise (GPR) over the electrode system are also discussed
Resumo:
El trabajo presentado en este documento se centra en la temática de la transferencia inalámbrica de energía, concretamente en aplicaciones de campo lejano, para llevar a cabo dicho trabajo nos centraremos en el diseño, implementación y medición de una rectenna operando en la banda ISM concretamente a una frecuencia de 2.45GHz, el objetivo primordial de este trabajo será analizar que parámetros intervienen en la eficiencia de conversión en la etapa de RF-DC a fin de lograr la máxima eficiencia de conversión posible. Para llevar a cabo dicho análisis se emplearán herramientas informáticas, concretamente se hará uso del software AWR Microwave Office, a través del cual se realizarán simulaciones SourcePull a fin de determinar la impedancia óptima de entrada que se le debe presentar a la etapa rectificadora RF-DC para conseguir la máxima eficiencia de conversión, una vez realizadas dichas pruebas se implementará físicamente un circuito rectenna a través del cual realizar medidas de SourcePull mediante un Wide Matching Range Slide Screw Tuner de MAURY MICROWAVE para cotejar las posibles diferencias con los resultados obtenidos en las simulaciones. Tras la fase de pruebas SourcePull se extrapolará una red de entrada en base a los datos obtenidos en las mediciones anteriores y se diseñará y fabricará un circuito rectenna con máxima eficiencia de conversión para un conjunto de valores de potencia de entrada de RF y carga de DC, tras lo cual se analizará la eficiencia del circuito diseñado para diferentes valores de potencia de RF de entrada y carga de DC. Como elemento rectificador emplearemos en nuestro trabajo el diodo Schottky HSMS-2820, los diodos Schottky se caracterizan por tener tiempos de conmutación relativamente bajos y pérdidas en directa reducidas los cual será fundamental a la hora de trabajar con niveles reducidos de potencia de RF de entrada, para implementar el circuito se empleará un substrato FR4 con espesor de 0.8mm para disminuir en la mayor medida posible las pérdidas introducidas por el dieléctrico, se analizarán diferentes posibilidades a la hora de implementar el filtro de RF a la salida del diodo rectificador y finalmente se optará por el empleo de un stub radial ya que será este el que mejor ancho de banda nos proporcione. Los resultados simulados se compararán con los resultados medidos sobre el circuito rectenna para determinar la similitud entre ambos. ABSTRACT. The work presented in this paper focuses on the issue of wireless transfer of energy, particularly applied to far-field applications, to carry out this work we focus on the design, implementation and measurement of a rectenna operating in the ISM band specifically at a frequency of 2.45GHz, the primary objective of this study is to analyze any parameter involved in the RF-DC conversion efficiency in order to achieve the maximum conversion efficiency as possible. Computer analysis tools will be used, particularly AWR Microwave Office software, in order to carry out SourcePull simulations to determine the optimal input impedance which must be presented to the rectifier stage for maximum conversion efficiency, once obtained, a rectenna circuit will be implemented to compute SourcePull measurements, and finally simulated results will be compared to measured results. Once obtained the result, an input network impedance is extrapolated based on data from previous measurements to design and implement a rectenna circuit with high conversion efficiency for a set of RF input power and DC load values , after that, the designed circuit efficiency will be analyzed for different values of RF input power and DC load. In this work a HSMS-2820 Schottky diode will be used as the rectifier , Schottky diodes are characterized by relatively low switching times and reduced direct losses, that properties will be essential when working with low RF input power levels , to implement the circuit a FR4 substrate with 0.8mm thickness is used to reduce as much as possible the dielectric losses, different possibilities to implement the RF filter to the output of the rectifier diode will be analyzed, finally we will opt for the use of a radial stub as this will provide the best bandwidth possible. The simulated results are compared with the results measured on the rectenna circuit to determine the similarity between them.
Resumo:
Background Brachial blood pressure predicts cardiovascular outcome at rest and during exercise. However, because of pulse pressure amplification, there is a marked difference between brachial pressure and central (aortic) pressure. Although central pressure is likely to have greater clinical importance, very little data exist regarding the central haemodynamic response to exercise. The aim of the present study was to determine the central and peripheral haemodynamic response to incremental aerobic exercise. Materials and methods Twelve healthy men aged 31 +/- 1 years (mean +/- SEM) exercised at 50%, 60%, 70% and 80% of their maximal heart rate (HRmax) on a bicycle ergometer. Central blood pressure and estimated aortic pulse wave velocity, assessed by timing of the reflected wave (T-R), were obtained noninvasively using pulse wave analysis. Pulse pressure amplification was defined as the ratio of peripheral to central pulse pressure and, to assess the influence of wave reflection on amplification, the ratio of peripheral pulse pressure to nonaugmented central pulse pressure (PPP : CDBP-P-1) was also calculated. Results During exercise, there was a significant, intensity-related, increase in mean arterial pressure and heart rate (P < 0.001). There was also a significant increase in pulse pressure amplification and in PPP : CDBP-P-1 (P < 0.001), but both were independent of exercise intensity. Estimated aortic pulse wave velocity increased during exercise (P < 0.001), indicating increased aortic stiffness. There was also a positive association between aortic pulse wave velocity and mean arterial pressure (r = 0.54; P < 0.001). Conclusions Exercise significantly increases pulse pressure amplification and estimated aortic stiffness.
Resumo:
Design and development of a photonic bandgap (PBG)-assisted shared-aperture dual-band orthogonal aperture-fed rectangular microstrip patch antenna element, which is suitable for a portable very small aperture terminal (VSAT), are presented in this paper. The dual-band dual-polarized antenna element achieves 21% input impedance bandwidth at the S- and C-bands. A comparison of the antenna with and without 2D PBG grids shows that the inclusion of PBG structures (PBGSs) improves the antenna performances. (c) 2005 Wiley Periodicals, Inc.
Resumo:
A practical, small-size, dual-helical antenna array mounted on a mobile handset model is designed for use as diversity/MIMO receiving antennas. The array is rigorously studied with respect to its diversity performance and the achievable channel capacity. It is found that a very low correlation coefficient, a high diversity gain, an equal-mean branch SNR, and a relatively matched input impedance can be achieved at the same time. It is shown that, at a remarkably small antenna separation (similar to 0.05 lambda), the signal correlation can be reduced to nearly zero, an almost ideal independent operation of the diversity antennas. The increase in MIMO channel capacity is 100% over a single antenna system. Both measured and simulation results are presented.