825 resultados para In-sample
Resumo:
In this work, both,solid phase microextraction (SPME) and solid phase extraction(SPE) were used to enrich organochlorine compounds in water samples and analyzed by gas chromatography with electron capture detector. The operating conditions of SPME have been studied and different kinds of solid phase were compared. Linear alkybenzene sulfonate(LAS) was added to the samples to investigate its effect on the analysis. The results indicated that polyacrylate was better than other commercial solid phases in extraction of moderated polar organic compounds and the sensitivity of SPME was higher than SPE. LAS affect much in liquid-liquid extraction and headspace SPME; but it has little effect on SPE and direct-SPME method. The applications showed that SPME was a fast and effective method in sample preparation.
Resumo:
AlGaN/GaN npn heterojunction bipolar transistor structures were grown by low-pressure MOCVD. Secondary ion mass spectroscopy (SIMS) measurements were carried out to study the Mg memory effect and redistribution in the emitter-base junction. The results indicated that there is a Mg-rich film formed in the ongrowing layer after the Cp2Mg source is switched off. The Mg-rich film can be confined in the base section by switching off the Cp2Mg source for appropriate time before the end of base growth. Low temperature growth of the undoped GaN spacer suppresses the Mg redistribution from Mg rich film. The delay rate of the Mg profile in sample C with spacer growing in low temperature is about 56 nm/decade, which becomes sharper than 80 nm/decade of the samples A and B without low temperature spacer. (C) 2005 Elsevier Ltd. All rights reserved.
Resumo:
Infrared absorption spectroscopy, optical transient current spectroscopy (OTCS), and photoluminescence (PL) spectroscopy are used to investigate the annealing induced evolution of defects in low-temperature (LT)-grown GaAs-related materials. Two LT samples of bulk GaAs (sample A) and GaAs/AlxGa1-xAs multiple-quantum-well. (MQW) structure (sample B) were grown at 220 and 320 degreesC on (001) GaAs substrates, respectively. A strong defect-related absorption band has been observed in both as-grown samples A and B. It becomes weaker in samples annealed at temperatures above 600 degreesC. In sample A, annealed in the range of 600-800 degreesC, a large negative decay signal of the optical transient current (OTC) is observed in a certain range of temperature, which distorts deep-level spectra measured by OTCS, making it difficult to identify any deep levels. At annealing temperatures of 600 and 700 degreesC, both As-Ga antisite and small As cluster-related deep levels are identified in sample B. It is found that compared to the As cluster, the As-Ga antisite has a larger activation energy and carrier capture rate. At an annealing temperature of 800 degreesC, the large negative decay signal of the OTC is also observed in sample B. It is argued that this negative decay signal of the OTC is related to large arsenic clusters. For sample B, transient PL spectra have also been measured to study the influence of the, defect evolution on optical properties of LT GaAs/AlxGa1-xAs MQW structures. Our results clearly identify a defect evolution from AS(Ga) antisites to arsenic clusters after annealing.
Resumo:
Undoped high resistivity (HR) GaN epilayers were grown on (0001) sapphire substrate by metalorganic chemical vapor deposition (MOCVD). Thermally stimulated current (TSC) and resistivity measurements have been carried out to investigate deep level traps. Deep levels with activation energies of 1.06eV and 0.85eV were measured in sample 1. Gaussian fitting of TSC spectra showed five deep levels in different samples. (c) 2006 WILEY VCH Vertag GmbH & Co. KGaA, Weinheim
Resumo:
This work evaluates the effect of wavelength positioning errors in spectral scans on analytical results when the Kalman filtering technique is used for the correction of line interferences in inductively coupled plasma atomic emission spectrometry (ICP-AES). The results show that a positioning accuracy of 0.1 pm is required in order to obtain accurate and precise estimates for analyte concentrations. The positioning error in sample scans is more crucial than that in model scans. The relative bias in measured analyte concentration originating from a positioning error in a sample scan increases linearly with an increase in the magnitude of the error and the peak distance of the overlapping lines, but is inversely proportional to the signal-to-background ratio. By the use of an optimization procedure for the positions of scans with the innovations number as the criterion, the wavelength positioning error can be reduced and, correspondingly, the accuracy and precision of analytical results improved.
Resumo:
The corrosion behaviour of titanium substance and the XPS characterization of Ti surface in the H2C2O4 solution have been first studied by X-ray photoelectron spectroscopy, The experimental results show that there am mile Ti-2 and Ti2+ on sample surface in 10% H2C2O4 solution for two boars corrosion at 80 degrees C, but if corrosion is extended to 4 hones, the surface composition is mainly TiO2 with a small amount of Ti2+. This result corresponds to the structure of TiH1.642 composion in sample surface found by XRD analysis. Since bath TiO2 and the surface coating RuO2 are of Gald-Redstone structure, therefore electrode materials of Ti-Ru are stable in chemical industry.
Resumo:
A suitable method for the pretreutment of dissolved nitrate samples in seawaters for nitrogen isotopic analysis was established. First, the seawater samples were processed by removing nitrite and amonium. Then Devard's alloy was added in sample for conversion of dissolved nitrate to ammonium. The sample was distilled, and then the ammonium condensate was collected with zeolite. after distillation, the collected condensate was filtered and prepared for determining nitropic values. Some tests of the method were conducted. The distillation condition, the influence of salinity on nitrogen isotopic analysis, absorption of ammonium onto zeolite and an improved method on a large volume of seawater were discussed in this study. The results showed that the distillation step had an average recovery of (104.9 +/- 4.2) % (n = 6) when distillating every 300 mL aliquot of the sample under a strong alkaline condition with 0.5 g devard's alloy and a distillation time of 30 min. The nitrogen isotopic fractionation decreased markedly when salinity was increased from 0% to 0.5%; further increase(1% - 3.5%) showed little effect. The adsorption rate of ammonium onto zeolite had a high yield of (95.96 +/- 1.08) % (n = 6) in average. An improved collection method was used to process a large volume of seawater with several distillations, and had good effect on analysis. The method had been applied to analyze water samples collected from Changjiang estuary. The analytical results indicate that the method is suitable for delta N-15 analysis of dissolved nitrate in seawaters. The present method could provide valuable information about the source and cycle mechanism of dissolved nitrogen in estuary waters.
Resumo:
Emodin, a natural anthraquinone compound isolated from the rhizome of rhubarb, is reported to suppress the growth of tumor in many clinical situations. In this study, we focused on the effect of emodin in human breast cancer BCap-37 cells and further understand the underlying molecular mechanism in treating breast cancer. Using MTT assay and flow cytometry, we demonstrated the critical role of emodin in the suppression of the proliferation of BCap-37 cells based on a concentration- and time-dependent manner. The increase of apoptotic rate was also observed after incubation of BCap-37 cells on emodin at 20 mu M and 50 mu M for 48 h. The cells exhibited typical apoptotic features including cellular morphological change, chromatin condensation and membrane blebbing. The results of the study further showed that Bcl-2 level decreased, while Bax and cytosolic cytochrome c levels in sample cells increased after the emodin treatment by using Western blot. The decline in the Bcl-2/Bax ratio and the increase of cytosolic cytochrome c concentration were consistent with the increase of the apoptotic ratio. The results strongly suggest that the disruption of the mitochondrial signaling pathway was involved in emodin-induced apoptosis in BCap-37 cells.
Resumo:
Trends in sample extremes are of interest in many contexts, an example being environmental statistics. Parametric models are often used to model trends in such data, but they may not be suitable for exploratory data analysis. This paper outlines a semiparametric approach to smoothing example extremes, based on local polynomial fitting of the generalized extreme value distribution and related models. The uncertainty of fits is assessed by using resampling methods. The methods are applied to data on extreme temperatures and on record times for the womens 3000m race.
Resumo:
Sedatives and tranquillisers are frequently used to reduce stress during the transportation of food producing animals. The most widely used classes of sedatives include the butyrophenone azaperone, the phenothiazines acepromazine, propionylpromazine, chlorpromazine and the beta-blocker, carazolol. For regulatory control purposes, tolerances for azaperone and carazolol have been set by the European Union as 100 and 25 mug kg(-1), respectively. Furthermore, the use of the phenothiazines is prohibited and therefore has a zero tolerance. A method for the detection of residues of five tranquillisers and one beta-blocker using a single ELISA plate has been developed. Kidney samples (2.5 g) were extracted with dichloromethane and applied to a competitive enzyme immunoassay using three polyclonal antibodies raised in rabbits against azaperol, propionylpromazine and carazolol conjugates. In sample matrix, the azaperol antibody cross-reacted 28.0% with azaperone and the propionylpromazine antibody cross-reacted 24.9% with acepromazine and 11.7% with chlorpromazine. In the ELISA, the detection capabilities of the six sedatives, azaperol, azaperone, carazolol, acepromazine, chlorpromazine, and propionylpromazine are 5, 15, 5, 5, 20 and 5 mug kg(-1), respectively. The proposed method is a sensitive and rapid multi-residue technique that offers a cost effective alternative to current published procedures, without any concession on the ability to detect sedative misuse.
Resumo:
This work explores the effects of argon and nitrogen, two electrochemically and chemically inert gases frequently used in sample preparation of room temperature ionic liquid (RTIL) solutions, on the eelectrochemical characterization of ferrocene (Fc) dissolved in the RTIL 1-ethyl-3-methylimidazolium bis(trifluoromethanesulfonyl)imide ([C(2)mim][NTf2]). Remarkably, chronoamperometrically determined diffusion coefficients of Fc in [C(2)mim][NTf2] are found to increase from 4.8 (+/- 0.2) x 10(-11) m(2) s(-1) under vacuum conditions to 6.6 (+/- 0.5) x 10(-11) m(2) s(-1) in an atmosphere of 1 atm Ar. In contrast, exposing a vacuum-purified sample to an atmosphere of 1 atm N-2 resulted in no significant change in the measured diffusion coefficient of Fc. The effect of dissolved argon on diffusion transport is unexpected and has implications in electrochemistry and elsewhere. Fc was found to volatilize under vacuum conditions. We propose, however, that evacuation of the cell by vacuum prior to electrochemical measurements being carried out is the only way to ensure that no contamination of the sample occurs, and use of an in situ method of determining the diffusion coefficient and concentration of Fc dispells,any ambiguity associated with Fc depletion by vacuum.
Resumo:
This paper investigates the performance of the tests proposed by Hadri and by Hadri and Larsson for testing for stationarity in heterogeneous panel data under model misspecification. The panel tests are based on the well known KPSS test (cf. Kwiatkowski et al.) which considers two models: stationarity around a deterministic level and stationarity around a deterministic trend. There is no study, as far as we know, on the statistical properties of the test when the wrong model is used. We also consider the case of the simultaneous presence of the two types of models in a panel. We employ two asymptotics: joint asymptotic, T, N -> infinity simultaneously, and T fixed and N allowed to grow indefinitely. We use Monte Carlo experiments to investigate the effects of misspecification in sample sizes usually used in practice. The results indicate that the assumption that T is fixed rather than asymptotic leads to tests that have less size distortions, particularly for relatively small T with large N panels (micro-panels) than the tests derived under the joint asymptotics. We also find that choosing a deterministic trend when a deterministic level is true does not significantly affect the properties of the test. But, choosing a deterministic level when a deterministic trend is true leads to extreme over-rejections. Therefore, when unsure about which model has generated the data, it is suggested to use the model with a trend. We also propose a new statistic for testing for stationarity in mixed panel data where the mixture is known. The performance of this new test is very good for both cases of T asymptotic and T fixed. The statistic for T asymptotic is slightly undersized when T is very small (
Resumo:
Tese de mestrado, Neurociências, Faculdade de Medicina, Universidade de Lisboa, 2015
Resumo:
We investigate the cointegration between VIX and CDS indices, and the possibility of exploiting it in an existing credit market timing investment model. We find cointegration over most of the sample period and the leadership of VIX over the CDS in the price discovery process. We present two methods for including cointegration into the model. Both strategies improve the in-sample and out-of-sample model performances, even though out-of-sample results are weaker. We find that in-sample better performances are explained by a stronger cointegration, concluding that in the presence of cointegration our strategies can be profitable in an investment model that considers transaction costs.
Resumo:
Microwave digestions of mercury in Standards Reference Material (SRM) coal samples with nitric acid and hydrogen peroxide in quartz vessels were compared with Teflon® vessel digestion by using flow injection cold vapor atomic absorption spectrometry. Teflon® vessels gave poor reproducibiUty and tended to deliver high values, while the digestion results from quartz vessel show good agreement with certificate values and better standard deviations. Trace level elements (Ag, Ba, Cd, Cr, Co, Cu, Fe, Mg, Mn, Mo, Pb, Sn, Ti, V and Zn) in used oil and residual oil samples were determined by inductively coupled plasma-optical emission spectrometry. Different microwave digestion programs were developed for each sample and most of the results are in good agreement with certified values. The disagreement with values for Ag was due to the precipitation of Ag in sample; while Sn, V and Zn values had good recoveries from the spike test, which suggests that these certified values might need to be reconsidered. Gold, silver, copper, cadmium, cobalt, nickel and zinc were determined by continuous hydride generation inductively coupled plasma-optical emission spectrometry. The performance of two sample introduction systems: MSIS™ and gas-liquid separator were compared. Under the respective optimum conditions, MSIS^"^ showed better sensitivity and lower detection limits for Ag, Cd, Cu, Co and similar values for Au, Ni and Zn to those for the gas-liquid separator.