995 resultados para IMPLANTATION


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Conclusion: The cochlear implant was beneficial as an attempt to restore hearing and improve communication abilities in this patient with profound sensorineural hearing loss secondary to Susac syndrome. Objective: To report the audiological outcomes of cochlear implantation (CI) in a young woman with Susac syndrome after a 6-month follow-up period. Susac syndrome is a rare disorder. It is clinically characterized by a typical triad of sensorineural deafness, encephalopathy, and visual defect, due to microangiopathy involving the brain, inner ear, and retina. Methods: This was a retrospective review of a case at a tertiary referral center. After diagnosis, the patient was evaluated by a multidisciplinary team and received a cochlear implant in her right ear. Results: The patient achieved 100% open-set sentence recognition in noise conditions and 92% monosyllable and 68% medial consonant recognition in quiet conditions after 6 months of implant use. She reported the use of the telephone 3 months after activation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective: To determine the effects of melatonin on rat endometrium morphology and embryo implantation. Design: Experimental study. Setting: Federal University of Sao Paulo, Brazil. Animal(s): Forty female rats. Intervention(s): GI: control, GII: sham-operated, GIII: pinealectomized, and GIV: pinealectomized rats that received melatonin during 3 months. The GI, GII, and Gin groups received the vehicle of melatonin (NaCl + ethanol). At the end of the treatment, the animals were killed during the estrous phase; the uterus was removed for morphometric analysis. Urine was collected for 6-sulfatoxymelatonin. Blood was collected for estrogen (E) and progesterone (P) level determinations. In a second experiment, female rats were used to evaluate the endometrial embryo implantation. Main Outcome Measure(s): Endometrial morphology and embryo implantation. Result(s): Gin presented the highest values for endometrial area and thickness index, number of endometrial glands, and eosinophils. The number of vessels of groups I, II, and IV was fewer than that of Gin. The highest number of eosinophils was detected in Gin in comparison to other groups. The implantation rate in Gin was the lowest of all groups. This implantation rate was significantly increased and restored toward normal in GIV. Conclusion(s): Our data suggested that, in nonphotoperiodic animals such as rats, melatonin may positively affect the endometrial morphology and improve embryo implantation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Our purpose was to retrospectively compare controlled ovarian stimulation(COH) in IVF cycles with administration of hCG on the day of menses (D1-hCG) with women not receiving hCG at day 1 of menses (Control). Data on maternal age, endocrine profile, amount of rFSH required, embryo characteristics, implantation and pregnancy rates were recorded for comparison between D1-hCG (n = 36) and Control (n = 64). Dose of rFSH required to accomplish COH was significantly lower in D1-hCG. Following ICSI, more top-quality embryos were available for transfer per patient in the D1-hCG and biochemical pregnancy rates per transfer were significantly higher in the D1-hCG. Significantly higher implantation and on-going pregnancy rates per embryo transfer were observed in D1-hCG (64%) compared to Control (41%). Administration of D1-hCG prior to COH reduces rFSH use and enhances oocyte developmental competence to obtain top quality embryos, and improves implantation and on-going pregnancy rates. At present it is not clear if the benefit is related to producing an embryo that more likely to implant or a more receptive uterus, or merely fortuitous and related to the relatively small power of the study.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: The incidence of venous lesions following transvenous cardiac device implantation is high. Previous implantation of temporary leads ipsilateral to the permanent devices, and a depressed left ventricular ejection fraction have been associated with an increased risk of venous lesions, though the effects of preventive strategies remain controversial. This randomized trial examined the effects of warfarin in the prevention of these complications in high-risk patients. Method: Between February 2004 and September 2007, we studied 101 adults who underwent a first cardiac device implantation, and who had a left ventricular ejection fraction <= 0.40, or a temporary pacing system ipsilateral to the permanent implant, or both. After device implantation, the patients were randomly assigned to warfarin to a target international normalized ratio of 2.0-3.5, or to placebo. Clinical and laboratory evaluations were performed regularly up to 6 months postimplant. Venous lesions were detected at 6 months by digital subtraction venography. Results: Venous obstructions of various degrees were observed in 46 of the 92 patients (50.0%) who underwent venography. The frequency of venous obstructions was 60.4% in the placebo, versus 38.6% in the warfarin group (P = 0.018), corresponding to an absolute risk reduction of 22% (relative risk = 0.63; 95% confidence interval = 0.013-0.42). Conclusions: Warfarin prophylaxis lowered the frequency of venous lesions after transvenous devices implantation in high-risk patients. (PACE 2009; 32:S247-S251)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Comparative studies between 5 French guiding catheter and others of larger size using the transfemoral approach to coronary stenting have not been described. Coronary stent implantation was performed in 90 patients in a randomized trial. The primary end-point was to compare the incidence of successful uncomplicated stent implantation per lesion with the 5F and 7F guiding catheters. Patients were excluded for excessive vessel tortuosity or anticipated need for equipment not fitting through a 5 catheter. Baseline characteristics and the use of direct stenting did not differ between the two groups. The primary success rate was 97.8% per patient in both groups and 98% per lesion in the 5 French and 97.9% in the 7 French. Guiding catheter change was necessary in 1 patient in each group to successfully complete the procedure in both groups. The amount of contrast used was 63 +/- 27.3 mL in the 5 French and 76 +/- 25 mL in the 7 French groups (P < 0.05). Vascular complications and blood transfusions occurred somewhat more frequently in the 7 French group (P = 0.058). The manual compression time after sheath removal was 5.1 +/- 2.0 min and 8.0 +/- 4.3 min, respectively, in the 5 and 7 French groups (P < 0.01). In conclusion, the 5 French guiding catheters showed a similar success rate with coronary stenting when compared to the 7 French, but the amount of contrast used and manual compression time after sheath removal, as well as the rate of vascular and bleeding complications, were reduced in the 5 French group.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aim of this study was to evaluate the efficiency of trypsin treatment on the inactivation of bovine herpesvirus type 1 (BoHV-1) on in vitro produced by fertilization and artificially infected bovine embryos. Bovine embryos on day 7 were exposed with 10 mu l of BoHV-1, Los Angeles strain 10(7.5) TCID. These embryos and control embryos were divided in two groups: submitted to the sequential washes or to the trypsin treatment according to the International Embryo Transfer Society (IETS) guidelines. The embryos and the last washing drop of each group were used as inoculum to infect Madin Darby bovine kidney (MDBK) cells and submitted to nested PCR reaction using the primer that encodes the gene conserved region of virus glycoprotein gB. The data have shown that the control embryos and their last washing drop were negative. The exposed embryos that were treated with trypsin have shown positive results on the n-PCR and MDBK culture, and their last washing drop were negative. Our data have demonstrated that the trypsin treatment was not able to eliminate the BHV-1 of the embryos, suggesting an interaction between virus and embryo.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Introduction: The aim of this study was to assess cyclic fatigue resistance in rotary nickel-titanium instruments submitted to nitrogen ion implantation by using a custom-made cyclic fatigue testing apparatus. Methods: Thirty K3 files, size #25, taper 0.04, were divided into 3 experimental groups as follows: group A, 12 files exposed to nitrogen ion implantation at a dose of 2.5 x 10(17) ions/cm(2), accelerating voltage of 200 kV, currents of 1 mu A/cm(2), 130 degrees C temperature, and vacuum conditions of 10 x 10(-6) torr for 6 hours; group B, 12 nonimplanted files; and group C, 6 files submitted to thermal annealing for 6 hours at 130 degrees C. One extra file was used for process control. All files were submitted to a cyclic fatigue test that was performed with an apparatus that allowed the instruments to rotate freely, simulating rotary instrumentation of a curved canal (40-degree, 5-mm radius curve). An electric motor handpiece was used with a contra-angle of 16:1 at an operating speed of 300 rpm and a torque of 2 N-cm. Time to failure was recorded with a stopwatch in seconds and subsequently converted to number of cycles to fracture. Data were analyzed with the Student t test (P < .05). Results: Ion-implanted instruments reached significantly higher cycle numbers before fracture (mean, 510 cycles) when compared with annealed (mean, 428 cycles) and nonimplanted files (mean, 381 cycles). Conclusions: Our results showed that nitrogen ion implantation improves cyclic fatigue resistance in rotary nickel-titanium instruments. Industrial implementation. of this surface modification technique would produce rotary nickel-titanium instruments with a longer working life. (J Endod 2010;36:1183-1186)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We evaluated patients with end-stage heart failure who have a high likelihood of response to cardiac resynchronization therapy (biventricular pacing). It appears that 20% of patients do not respond to this expensive therapy despite the use of selection criteria (dilated cardiomyopathy, heart failure, New York Heart Association class II or IV, left ventricular election fraction 120 ms). The presence of left ventricular dys-synchrony is needed to result in improvement after cardiac resynchronization therapy. (C)2003 by Excerpta Medica, Inc.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Heart failure is the final stage of most of cardiac diseases. It is a complex syndrome in which the patients should have the following features: symptoms of heart failure, typically shortness of breath at rest or during exertion, and/or fatigue; signs of fluid retention such as pulmonary congestion or ankle swelling; and objective evidence of an abnormality of the structure or function of the heart at rest. This progressive syndrome as a high incidence and prevalence and poor prognosis: four-year mortality is around 50% with 40% of the patients admitted to hospital dying or readmitted within a year. With ageing, many patients will develop chronic heart failure, which, because of its symptoms, patient’s awareness of their risk of dying, and the effects of therapy, together with frequent hospitalizations, has considerable impact on patient’s health-related quality of life.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The magnetic and electrical properties of Ni implanted single crystalline TiO2 rutile were studied for nominal implanted fluences between 0.5 x 10(17) cm(-2) and 2.0 x 10(17) cm(-2) with 150 keV energy, corresponding to maximum atomic concentrations between 9 at% and 27 at% at 65 nm depth, in order to study the formation of metallic oriented aggregates. The results indicate that the as implanted crystals exhibit superparamagnetic behavior for the two higher fluences, which is attributed to the formation of nanosized nickel clusters with an average size related with the implanted concentration, while only paramagnetic behavior is observed for the lowest fluence. Annealing at 1073 K induces the aggregation of the implanted nickel and enhances the magnetization in all samples. The associated anisotropic behavior indicates preferred orientations of the nickel aggregates in the rutile lattice consistent with Rutherford backscattering spectrometry-channelling results. Electrical conductivity displays anisotropic behavior but no magnetoresistive effects were detected. (C) 2013 Elsevier B.V. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In two distinct experiments, immature S. mansoni worms (LE strain, Belo Horizonte, Brazil), aged 20 days, obtained from the portal system of white outbred mice, were irradiated with 14 and 4 Krad, respectively. Afterwards, the worms were directly inoculated into the portal vein of normal mice. Inoculation was performed with 20 irradiated worms per animal. Fifty days after inoculation, the mice that received 4 and 14 Krad-irradiated worms and their respective controls were infected with S. mansoni cercariae (LE strain), by transcutaneous route. Twenty days after this challenge infection, the animals were sacrificed and perfused for mature irradiated (90-day-old) and immature (20-day-old) worm counts. Analysis of the results showed that statistically significant protection against cercariae occurred in both groups with irradiated worms.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The classic transvenous implantation of a permanent pacemaker in a pectoral location may be precluded by obstruction of venous access through the superior vena cava or recent infection at the implant site. When these barriers to the procedure are bilateral and there are also contraindications or technical difficulties to performing a thoracotomy for an epicardial approach, the femoral vein, although rarely used, can be a viable alternative. We describe the case of a patient with occlusion of both subclavian veins and a high risk for mini-thoracotomy or videothoracoscopy, who underwent implantation of a permanent single-chamber pacemaker via the right femoral vein.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

INTRODUCTION: The septal position is an alternative site for cardiac pacing (CP) that is potentially less harmful to cardiac function. METHODS: Patients with Chagas disease without heart failure submitted to permanent pacemaker (PP) implantation at the Clinics Hospital of the Triângulo Mineiro Federal University (UFTM), were selected from February 2009 to February 2010. The parameters analyzed were ventricular remodeling, the degree of electromechanical dyssynchrony (DEM), exercise time and VO2 max during exercise testing (ET) and functional class (NYHA). Echocardiography was performed 24 to 48h following implantation and after one year follow-up. The patients were submitted to ET one month postprocedure and at the end of one year. RESULTS: Thirty patients were included. Patient mean age was 59±13 years-old. Indication for PP implantation was complete atrioventricular (AV) block in 22 (73.3%) patients and 2nd degree AV block in the other eight (26.7%). All patients were in NYHA I and no changes occurred in the ET parameters. No variations were detected in echocardiographic remodeling measurements. Intraventricular dyssynchrony was observed in 46.6% of cases and interventricular dyssynchrony in 33.3% of patients after one year. CONCLUSIONS: The findings of this work suggest that there is not significant morphological and functional cardiac change following pacemaker implantation in septal position in chagasic patients with normal left ventricular function after one year follow-up. Thus, patients may remain asymptomatic, presenting maintenance of functional capacity and no left ventricular remodeling.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE: The authors analyzed the 30-day and 6-month outcomes of 1,126 consecutive patients who underwent coronary stent implantation in 1996 and 1997. METHODS: The 30-day results and 6-month angiographic follow-up were analyzed in patients treated with coronary stents in 1996 and 1997. All patients underwent coronary stenting with high-pressure implantation (>12 atm) and antiplatelet drug regimen (aspirin plus ticlopidine). RESULTS: During the study period, 1,390 coronary stents were implanted in 1,200 vessels of 1,126 patients; 477 patients were treated in the year 1996 and 649 in 1997. The number of percutaneous procedures performed using stents increased significantly in 1997 compared to 1996 (64 % vs 48%, p=0.0001). The 30-day results were similar in both years; the success and stent thrombosis rates were equal (97% and 0.8%, respectively). The occurrence of new Q wave MI (1.3% vs 1.1%, 1996 vs 1997, p=NS), emergency coronary bypass surgery (1% vs 0.6%, 1996 vs 1997, p=NS) and 30-day death rates (0.2% vs 0.5%, 1996 vs 1997, p=NS) were similar. The 6-month restenosis rate was 25% in 1996 and 27% in 1997 (p= NS); the target vessel revascularization rate was 15% in 1996 and 16% in 1997 (p = NS). CONCLUSIONS: Intracoronary stenting showed a high success rate and a low incidence of 30-day occurrence of new major coronary events in both periods, despite the greater angiographic complexity of the patients treated with in 1997. These adverse variables did not have a negative influence at the 6-month clinical and angiographic follow-up, with similar rates of restenosis and ischemia-driven target lesion revascularization rates.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: Comparative analysis of the in-hospital results after primary implantation of stents or coronary balloon angioplasty in patients with acute myocardial infarction (MI). METHODS: CENIC (National Center of Cardiovascular Interventions) gathered data on 3,924 patients undergoing coronary angioplasty (in the primary form, without the previous use of thrombolytic agents) in the first 24 hours after a MI, during the period of 1996-1998. From these 3,924 patients, 1,337 (34%) underwent stent implantation. We analyzed the success of the procedure and the occurrence of adverse cardiac events. RESULTS: In patients undergoing stent implantation there were more males (77% vs 69%, p=0.001), previous by pass surgery (6.3% vs. 4.5%, p=0.01), anterior MI and stent implantation in left descending artery (55% vs. 48% vs. p=0.009), and saphenous vein bypass grafts (3.3% vs. 1.9%). the procedure was more succesful in the group of stents (97% vs. 84%, p=0.001) and reinfarction rate (2.5 vs. 4%, p=0.002). The need for emergency revascularization was similar (1% vs. 1.1%, NS). Total in-hospital mortality was lower in stent group (3.4% vs. 7. 2%, p=0.0001) and this effect was in patients Killip class III/V (19.5% vs. 32.5%, p= 0.002) because there was no difference in patients class I/II (1.7% vs. 2.8%, p=0.9). CONCLUSION: Primary stent implantation in acute myocardial infarction showed better early results than balloon angioplasty alome.