958 resultados para High Reliability
Resumo:
Objectives: To investigate the test-retest reliability of mechanical parameters derived from a 3-min isokinetic all-out test, performed at 60 and 100 rpm. Reliability and validity of the peak oxygen uptake derived from 3-min isokinetic all-out test were also tested. Design: 14 healthy male subjects completed an incremental ramp testing and four randomized 3-min isokinetic all-out test (two at 60 rpm and two at 100 rpm). Methods: The absolute and relative reliability of the following parameters were analyzed: peak power, mean power, end power, fatigue index, work performed above end power and peak oxygen uptake. Results: No difference was found between each two sets of data, although there were between-cadence differences for peak power, mean power, end power, and fatigue index. Higher intra-class correlation (ICC) and lower coefficient of variation (CV) were found for end power (ICC = 0.91 and 0.95; CV = 5.6 and 5.7%) and mean power (ICC = 0.97 and 0.98; CV = 2.4 and 3.1%), than for peak power (ICC = 0.81 and 0.84; CV = 8.7 and 10%) and work performed above end power (ICC = 0.79 and 0.84; CV = 7.9 and 10.6%; values reported for 60 rpm and 100 rpm, respectively). High reliability scores were also observed for peak oxygen uptake at both cadences (60 rpm, CV = 3.2%; 100 rpm, CV = 2.3%,) with no difference with the incremental ramp testing peak oxygen uptake. Conclusions: The power profile and peak oxygen uptake of a 3-min isokinetic all-out test are both highly reliable, whether the test is performed at 60 or 100 rpm. Besides, peak oxygen uptake and work performed above end power were not affected by the change in cadence while peak power, mean power, end power, and fatigue index were. © 2013.
Resumo:
This study compared the effectiveness of the multifocal visual evoked cortical potentials (mfVEP) elicited by pattern pulse stimulation with that of pattern reversal in producing reliable responses (signal-to-noise ratio >1.359). Participants were 14 healthy subjects. Visual stimulation was obtained using a 60-sector dartboard display consisting of 6 concentric rings presented in either pulse or reversal mode. Each sector, consisting of 16 checks at 99% Michelson contrast and 80 cd/m2 mean luminance, was controlled by a binary m-sequence in the time domain. The signal-to-noise ratio was generally larger in the pattern reversal than in the pattern pulse mode. The number of reliable responses was similar in the central sectors for the two stimulation modes. At the periphery, pattern reversal showed a larger number of reliable responses. Pattern pulse stimuli performed similarly to pattern reversal stimuli to generate reliable waveforms in R1 and R2. The advantage of using both protocols to study mfVEP responses is their complementarity: in some patients, reliable waveforms in specific sectors may be obtained with only one of the two methods. The joint analysis of pattern reversal and pattern pulse stimuli increased the rate of reliability for central sectors by 7.14% in R1, 5.35% in R2, 4.76% in R3, 3.57% in R4, 2.97% in R5, and 1.78% in R6. From R1 to R4 the reliability to generate mfVEPs was above 70% when using both protocols. Thus, for a very high reliability and thorough examination of visual performance, it is recommended to use both stimulation protocols.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
This study compared the effectiveness of the multifocal visual evoked cortical potentials (mfVEP) elicited by pattern pulse stimulation with that of pattern reversal in producing reliable responses (signal-to-noise ratio >1.359). Participants were 14 healthy subjects. Visual stimulation was obtained using a 60-sector dartboard display consisting of 6 concentric rings presented in either pulse or reversal mode. Each sector, consisting of 16 checks at 99% Michelson contrast and 80 cd/m² mean luminance, was controlled by a binary m-sequence in the time domain. The signal-to-noise ratio was generally larger in the pattern reversal than in the pattern pulse mode. The number of reliable responses was similar in the central sectors for the two stimulation modes. At the periphery, pattern reversal showed a larger number of reliable responses. Pattern pulse stimuli performed similarly to pattern reversal stimuli to generate reliable waveforms in R1 and R2. The advantage of using both protocols to study mfVEP responses is their complementarity: in some patients, reliable waveforms in specific sectors may be obtained with only one of the two methods. The joint analysis of pattern reversal and pattern pulse stimuli increased the rate of reliability for central sectors by 7.14% in R1, 5.35% in R2, 4.76% in R3, 3.57% in R4, 2.97% in R5, and 1.78% in R6. From R1 to R4 the reliability to generate mfVEPs was above 70% when using both protocols. Thus, for a very high reliability and thorough examination of visual performance, it is recommended to use both stimulation protocols.
Resumo:
Background and Purpose. Arm lymphedema following breast cancer In this study, we assessed the surgery is a continuing problem. reliability and validity of circumferential measurements and water displacement for measuring upper-limb volume. Subjects. Participants included subjects who had had breast cancer surgery, including axillary dissection-19 with and 22 without a diagnosis of arm lymphedema-and 25 control subjects. Methods. Two raters measured each subject by using circumferential tape measurements at specified distances from the fingertips and in relation to anatornic landmarks and by using water displacement. Interrater reliability was calculated by analysis of variance and multilevel modeling. Volumes from circumferential measurements were compared with those from water displacement by use of means and correlation coefficients, respectively. The standard error of measurement, minimum detectable change (MDC), and limits of agreement (LOA) for volumes also were calculated. Results. Arm volumes obtained with these methods had high reliability. Compared with volumes from water displacement, volumes from circumferential measurements had high validity, although these volumes were slightly larger. Expected differences between subjects with and without clinical lymphedema following breast cancer were found. The MDC of volumes or the error associated with a single measure for data based oil anatomic landmarks was lower than that based oil distance from fingertips. The mean LOA with water displacement were lower for data based on anatomic landmarks than for data based on distance from fingertips. Discussion and Conclusion. Volumes calculated from anatomic landmarks are reliable, valid, and more accurate than those obtained from circumferential measurements based on distance from fingertips.
Resumo:
In the deregulated Power markets it is necessary to have a appropriate Transmission Pricing methodology that also takes into account “Congestion and Reliability”, in order to ensure an economically viable, equitable, and congestion free power transfer capability, with high reliability and security. This thesis presents results of research conducted on the development of a Decision Making Framework (DMF) of concepts and data analytic and modelling methods for the Reliability benefits Reflective Optimal “cost evaluation for the calculation of Transmission Cost” for composite power systems, using probabilistic methods. The methodology within the DMF devised and reported in this thesis, utilises a full AC Newton-Raphson load flow and a Monte-Carlo approach to determine, Reliability Indices which are then used for the proposed Meta-Analytical Probabilistic Approach (MAPA) for the evaluation and calculation of the Reliability benefit Reflective Optimal Transmission Cost (ROTC), of a transmission system. This DMF includes methods for transmission line embedded cost allocation among transmission transactions, accounting for line capacity-use as well as congestion costing that can be used for pricing using application of Power Transfer Distribution Factor (PTDF) as well as Bialek’s method to determine a methodology which consists of a series of methods and procedures as explained in detail in the thesis for the proposed MAPA for ROTC. The MAPA utilises the Bus Data, Generator Data, Line Data, Reliability Data and Customer Damage Function (CDF) Data for the evaluation of Congestion, Transmission and Reliability costing studies using proposed application of PTDF and other established/proven methods which are then compared, analysed and selected according to the area/state requirements and then integrated to develop ROTC. Case studies involving standard 7-Bus, IEEE 30-Bus and 146-Bus Indian utility test systems are conducted and reported throughout in the relevant sections of the dissertation. There are close correlation between results obtained through proposed application of PTDF method with the Bialek’s and different MW-Mile methods. The novel contributions of this research work are: firstly the application of PTDF method developed for determination of Transmission and Congestion costing, which are further compared with other proved methods. The viability of developed method is explained in the methodology, discussion and conclusion chapters. Secondly the development of comprehensive DMF which helps the decision makers to analyse and decide the selection of a costing approaches according to their requirements. As in the DMF all the costing approaches have been integrated to achieve ROTC. Thirdly the composite methodology for calculating ROTC has been formed into suits of algorithms and MATLAB programs for each part of the DMF, which are further described in the methodology section. Finally the dissertation concludes with suggestions for Future work.
Resumo:
The Pierre Auger Cosmic Ray Observatory North site employs a large array of surface detector stations (tanks) to detect the secondary particle showers generated by ultra-high energy cosmic rays. Due to the rare nature of ultra-high energy cosmic rays, it is important to have a high reliability on tank communications, ensuring no valuable data is lost. The Auger North site employs a peer-to-peer paradigm, the Wireless Architecture for Hard Real-Time Embedded Networks (WAHREN), designed specifically for highly reliable message delivery over fixed networks, under hard real-time deadlines. The WAHREN design included two retransmission protocols, Micro- and Macro- retransmission. To fully understand how each retransmission protocol increased the reliability of communications, this analysis evaluated the system without using either retransmission protocol (Case-0), both Micro- and Macro-retransmission individually (Micro and Macro), and Micro- and Macro-retransmission combined. This thesis used a multimodal modeling methodology to prove that a performance and reliability analysis of WAHREN was possible, and provided the results of the analysis. A multimodal approach was necessary because these processes were driven by different mathematical models. The results from this analysis can be used as a framework for making design decisions for the Auger North communication system.
Resumo:
Universidade Estadual de Campinas . Faculdade de Educação Física
Resumo:
TEMA: a avaliação da eficiência mastigatória pela análise colorimétrica com beads, pode ser um método promissor, mas não há relatos sobre a sua confiabilidade. OBJETIVO: investigar a confiabiabilidade das beads para teste de eficiência mastigatória e a correlação com a atividade eletromiográfica dos músculos masseter e temporal anterior. MÉTODO: participaram dezenove sujeitos adultos jovens, nove do gênero masculino e dez do feminino com idades entre dezoito e vinte-oito anos, com dentição completa, sem histórico de desordem temporomandibular, trauma, cirurgia na região de cabeça e pescoço, tratamento ortodôntico ou fonoaudiológico. O teste de eficiência mastigatória foi realizado com beads nas condições: mastigação habitual, mastigação unilateral direita e esquerda, com duração de 20 segundos. Simultaneamente, foi realizada a eletromiografia. A atividade em máxima intercuspidação habitual dos dentes também foi registrada. A quantidade de fucsina liberada após a mastigação foi medida usando o espectrofotômetro Beckman DU-7 UV-Visible (Beckman Inc., Palo Alto, CA, USA). RESULTADOS: houve alta confiabilidade do teste de eficiência mastigatória (r = 0,86, p < 0,01) e correlação significante com a atividade eletromiográfica (r = 0,76, p < 0,01). Também houve correlações positivas quando as provas foram analisadas separadamente. CONCLUSÃO: o teste de eficiência mastigatória realizado com beads mostrou-se um método confiável e correlacionado positivamente à atividade eletromiográfica dos músculos temporal anterior e músculos masseter.
Resumo:
OBJETIVO: Avaliar a confiabilidade do questionário Lista de Atividades Físicas em crianças. MÉTODOS: O estudo é parte da adaptação transcultural do questionário, realizado com 83 escolares de sete a dez anos, matriculados do segundo ao quinto ano do ensino fundamental da cidade de São Paulo, SP, em 2008. O questionário foi respondido pela criança por meio de entrevista individual, apresenta lista com 21 atividades físicas moderadas a vigorosas realizadas no dia anterior, é dividido em períodos (antes, durante e após a escola) e possui seção de avaliação da entrevista. O questionário permite quantificar: tempo em atividades físicas e sedentárias; e custos metabólicos total e ponderado. A confiabilidade foi avaliada comparando-se duas entrevistas realizadas com intervalo médio de três horas. Para a seção C (avaliação da entrevista), compararam-se dados da primeira entrevista e de um avaliador externo. Utilizaram-se a proposta de Bland & Altman e os coeficientes de correlação intraclasse e de correlação de concordância de Lin na avaliação da confiabilidade. RESULTADOS: Os limites inferiores dos coeficientes de correlação intraclasse para os desfechos analisados variaram de 0,84 a 0,96. A precisão e concordância variaram, respectivamente, de 0,83 a 0,97 e de 0,99 a 1. A reta estimada a partir de pares de valores obtidos nas duas aplicações para atividade física indica elevada precisão dos dados. O item da entrevista com pior resultado foi a habilidade em estimar tempo (regular em 27,7% das entrevistas). Os itens da seção C apresentaram coeficientes de correlação intraclasse entre 0,60 e 0,70, exceto o nível de cooperação (0,46). CONCLUSÕES: A Lista de Atividades Físicas apresenta alta confiabilidade para aferir atividade física e sedentária do dia anterior em crianças.
Resumo:
Background and Study Aim: Evaluation of sport skills test can be very useful tool for coach practice. The aim of the present paper was: (a) to evaluate the reliability and accuracy of the Specific Physical Fitness Tests (SPFT) (b) to review the results of karate athletes who represent different weight categories, and who are at different stages of schooling; (c) to establish grading criteria of physical fitness preparation. Material/Methods: The reseach was conducted among 219 Kyokushin karate players, whose profiles were presented as (chi) over bar +/- SD and their main characteristics were the following: age 26.8 +/- 4.67 (19-39) years, body mass 75.2 +/- 8.35 (50-97) kg and body height 176.4 +/- 5.67 (160-196) cm. The value of the BMI amounted to 24.1 +/- 2.17 (17.9-29.4) kg/m(2). All the subjects of the research had training experience of 10.5 +/- 3.71 (4-20) years and their degree of proficiency ranged from 4(th) kyu to 3(rd) dan. The physical fitness trials proposed by Story (1989) included: hip turning speed, speed punches, flexibility, rapid kicks, agility, and evasion actions. It was supplemented by a test of local strength endurance, composing a battery of the SPFT, which was implemented by first of the authors between 1991 and 2006. Results: SPFT is characterized by high reliability and it can be used to diagnose the physical fitness preparation and monitor the individual results of training. It discriminates accurately competitors with different sports level and it is characterized by very high accuracy, it is correlated with the test results of motor general physical fitness abilities and coordination abilities as well as it is connected with the somatic build of the athlete. The performance classification table was developed on the basis of our research. Discussion: Results obtained in SPFT were shortly discussed. Conclusions: The collected results of our research allowed us to come to, the conclusion: The table can be applied not only to assess karate fighters, but also adepts in taekwondo, kick-boxing, ju-jitsu, hapkido or other mixed martial arts.
Resumo:
This study examined the psychometric properties of the Brazilian versions of the Fagerstrom Test for Nicotine Dependence (FTND) and the Heaviness of Smoking Index (HSI). The test-retest reliability of the FTND was assessed in a sample of 61 smoking university students, with a 15-day interval between assessments. The interrater reliability was examined in 30 smoking patients of a psychosocial care center for alcohol and drug users (PCC-AD). The reliability coefficient was estimated by the kappa and intraclass correlation coefficients. The predictive validity, internal consistency, and factor structure of the FTND and the HSI were evaluated by factor analysis in 271 smokers treated at an emergency unit and at the PCC-AD. The gold standard was the nicotine dependence criteria of DSM-IV, as assessed by the Structured Clinical Interview for DSM-IV. The FTND showed high reliability, with correlation coefficients of .92 for test-retest reliability and .99 for interrater reliability. Both the FTND and the HSI presented high levels of sensitivity and specificity. The internal consistency evaluation yielded a Cronbach`s alpha coefficient of .83 for the FTND and of .56 for the HSI. An exploratory factor analysis found 2 factors in the FTND, which were validated by a confirmatory factor analysis. The results obtained in this study confirm the validity and reliability of the Brazilian versions of the FTND and the HSI.
Resumo:
The aim of this study was to determine the applicability of multislice and cone-beam computerized tomography (CT) in the assessment of bone defects in patients with oral clefts. Bone defects were produced in 9 dry skulls to mimic oral clefts. All defects were modeled with wax. The skulls were submitted to multislice and cone-beam CT. Subsequently, physical measurements were obtained by the Archimedes principle of water displacement of wax models. The results demonstrated that multislice and cone-beam CT showed a high efficiency rate and were considered to be effective for volumetric assessment of bone defects. It was also observed that both CT modalities showed excellent results with high reliability in the study of the volume of bone defects, with no difference in performance between them. The clinical applicability of our research has shown these CT modalities to be immediate and direct, and they is important for the diagnosis and therapeutic process of patients with oral cleft. (Oral Surg Oral Med Oral Pathol Oral Radiol Endod 2011; 112: 249-257)
Resumo:
Polymers have become the reference material for high reliability and performance applications. In this work, a multi-scale approach is proposed to investigate the mechanical properties of polymeric based material under strain. To achieve a better understanding of phenomena occurring at the smaller scales, a coupling of a Finite Element Method (FEM) and Molecular Dynamics (MD) modeling in an iterative procedure was employed, enabling the prediction of the macroscopic constitutive response. As the mechanical response can be related to the local microstructure, which in turn depends on the nano-scale structure, the previous described multi-scale method computes the stress-strain relationship at every analysis point of the macro-structure by detailed modeling of the underlying micro- and meso-scale deformation phenomena. The proposed multi-scale approach can enable prediction of properties at the macroscale while taking into consideration phenomena that occur at the mesoscale, thus offering an increased potential accuracy compared to traditional methods.
Resumo:
AIM: This work presents detailed experimental performance results from tests executed in the hospital environment for Health Monitoring for All (HM4All), a remote vital signs monitoring system based on a ZigBee® (ZigBee Alliance, San Ramon, CA) body sensor network (BSN). MATERIALS AND METHODS: Tests involved the use of six electrocardiogram (ECG) sensors operating in two different modes: the ECG mode involved the transmission of ECG waveform data and heart rate (HR) values to the ZigBee coordinator, whereas the HR mode included only the transmission of HR values. In the absence of hidden nodes, a non-beacon-enabled star network composed of sensing devices working on ECG mode kept the delivery ratio (DR) at 100%. RESULTS: When the network topology was changed to a 2-hop tree, the performance degraded slightly, resulting in an average DR of 98.56%. Although these performance outcomes may seem satisfactory, further investigation demonstrated that individual sensing devices went through transitory periods with low DR. Other tests have shown that ZigBee BSNs are highly susceptible to collisions owing to hidden nodes. Nevertheless, these tests have also shown that these networks can achieve high reliability if the amount of traffic is kept low. Contrary to what is typically shown in scientific articles and in manufacturers' documentation, the test outcomes presented in this article include temporal graphs of the DR achieved by each wireless sensor device. CONCLUSIONS: The test procedure and the approach used to represent its outcomes, which allow the identification of undesirable transitory periods of low reliability due to contention between devices, constitute the main contribution of this work.