938 resultados para Geiger-M©·uller counters.
Resumo:
The cosmopolitan family Calamoceratidae Ulmer, 1906, has 8 living genera, among them Phylloicus Muller, 1880, with species distributed from South to Central America. This genus is characterized by its dark-colored adults (brown to black) with diurnal to crepuscular habits. In this paper, the adults, pupae, and larvae of Phylloicus camargoi n. sp. are described and illustrated. The new species is easily diagnosed by male tergum X bearing a short, digitate, setose, basodorsal process; 2 short, digitate, hairless, lateral processes; and 2 pairs of very short processes on the posterior margin: a pair of digitate, hairless, posterolateral processes, and a pair of posteromesal processes. Additional diagnostic characters are the presence of 3 color bands on the forewings, 2 golden longitudinal bands and a white transversal one.
Resumo:
In this study, we demonstrate that Muller cells cultured from human retinas are capable of strongly expressing the glycine transporter Glyt-1 as assessed by immunocytochemistry. By contrast, intact normal and pathological human retinas exhibit Glyt-1 immunoreactivity only in neurons. These data suggest that Glyt-1 expression in cultured Muller cells is an epiphenomenon associated with culturing in vitro, rather than a normal physiological or even pathophysiological phenomenon in vivo. (C) 2001 Wiley-Liss, Inc.
Resumo:
Relata-se a introdução em nosso meio de Thiara (Melanoides) tuberculata possivelmente anterior a 1967, quando pela primeira vez foi coletada em Santos. Essa espécie pode comportar-se como primeiro hospedeiro intermediário de Paragonimus westermani e de Clonorchis sinensis. Somente o último trematódeo tem alguma possibilidade de vir a parasitar o homem, em nosso meio.
Resumo:
Atualmente, as radiações ionizantes desempenham um papel fundamental nas áreas de diagnóstico e terapia, estando omnipresentes em ambientes hospitalares. Contudo, devido aos efeitos biológicos adversos da radiação, torna-se essencial a protecção dos profissionais de saúde e pacientes. Consequentemente, um array de detetores capazes de produzir um sinal acústico, aquando da presença de radiação ionizante excedendo determinados valores limite e transmissão via wireless das leituras para um sistema central _e de grande interesse prático. Nesta dissertação, foi implementado um sistema capaz de alimentar um array de sensores de radiação para monitorização de diferentes espaços e transmissão das leituras efetuadas via wireless. A aquisição de dados foi realizada, recorrendo à utilização de um conversor analógico-digital. Vários testes de validação foram realizados, através de vários passos para alcançar a concretização do sistema final, nomeadamente testes relativos ao circuito de detecção, módulos de comunicação wireless, bem como o uso de diferentes ambientes de desenvolvimento integrados (IDE). Os resultados destes testes mostram a visualização e gravação adequadas dos dados relativos aos níveis de radiação, bem como a transmissão de dados de forma viável, permitindo a monitorização de espaços sujeitos à presença de radiação ionizante. Desta forma, um array de contadores Geiger-Müller, ligados a módulos wireless XBee open-source e uma placa Arduino, possibilitou a implementação de um sistema viável e de baixo custo para monitorização de radiação ionizante e registar esses mesmos dados para posterior análise.
Resumo:
Nuestro proyecto intentará conseguir la contabilización de los fallos en los accesos a caché de segundo nivel (L2) de un determinado proceso, para lo que trataremos de habilitar los contadores de rendimiento del Pentium 4, configurarlos para obtener la información buscada de acuerdo a los eventos a monitorizar y, por último, obtener esta información y dejarla adisposición de la aplicación de usuario que la requiera.
Resumo:
OBJECTIVE: To evaluate the results of Muller's muscle-conjunctival resection for correction of blepharoptosis and to discuss the advantages of this procedure. METHODS: 38 patients (39 eyelids) were submitted to Muller's muscle-conjunctival resection. Blepharoptosis varied from 1.0 mm to 3.0 mm (mean: 2.0 mm). The amount of eyelid elevation produced by phenylephrine guided the amount of tissue to be resected. RESULT: 33 eyelids (85%) treated with this procedure were cosmetically acceptable. CONCLUSIONS: Muller's muscle-conjunctival resection procedure is a relatively simple technique for blepharoptosis, with good levator function and positive 10% phenylephrine test. The advantages are: preservation of tarsus and predictable results.
Resumo:
The gated operation is proposed as an effective method to reduce the noise in pixel detectors based on Geiger mode avalanche photodiodes. A prototype with the sensor and the front-end electronics monolithically integrated has been fabricated with a conventional HV-CMOS process. Experimental results demonstrate the increase of the dynamic range of the sensor by applying this technique.
Resumo:
The need to move forward in the knowledge of the subatomic world has stimulated the development of new particle colliders. However, the objectives of the next generation of colliders sets unprecedented challenges to the detector performance. The purpose of this contribution is to present a bidimensional array based on avalanche photodiodes operated in the Geiger mode to track high energy particles in future linear colliders. The bidimensional array can function in a gated mode to reduce the probability to detect noise counts interfering with real events. Low reverse overvoltages are used to lessen the dark count rate. Experimental results demonstrate that the prototype fabricated with a standard HV-CMOS process presents an increased efficiency and avoids sensor blindness by applying the proposed techniques.
Resumo:
Avalanche photodiodes operated in the Geiger mode offer a high intrinsic gain as well as an excellent timing accuracy. These qualities make the sensor specially suitable for those applications where detectors with high sensitivity and low timing uncertainty are required. Moreover, they are compatible with standard CMOS technologies, allowing sensor and front-end electronics integration within the pixel cell. However, the sensor suffers from high levels of intrinsic noise, which may lead to erroneous results and limit the range of detectable signals. They also increase the amount of data that has to be stored. In this work, we present a pixel based on a Geiger-mode avalanche photodiode operated in the gated mode to reduce the probability to detect noise counts interfering with photon arrival events. The readout circuit is based on a two grounds scheme to enable low reverse bias overvoltages and consequently lessen the dark count rate. Experimental characterization of the fabricated pixel with the HV-AMS 0.35µm standard technology is also presented in this article.
Resumo:
Donateur : Bonaparte, Roland (1858-1924)
Resumo:
Sagitta setosa is a neritic Chaetognath exhibiting a discontinuous geographic distribution. To assess the influence of its discontinuous geographic distribution on morphometric variability between isolated populations, we conducted a biometric study of S. setosa from three different locations: Goteborg and Plymouth (North Atlantic) and Barcelona ( Western Mediterranean). Out results do indicate some disparity between the populations that is reflected not in size differences, largely determined by water temperature, but in shape (body proportions).
Resumo:
The objective of this project was to gather all the counters which are used on HSPA performance monitoring. The main purpose was to create a compact packet of HSPA performance counters and radio network monitoring which Ericsson's employees can then use in their daily work. The study includes a short introduction to the architecture of the 3G-radio access network. The HSPA technology and HSPA performance are presented including a functional description of performance counters and KPIs, which are used for performance management and monitoring. The theory part of the study also covers an overview of performance management in OSS-RC. The final part of the study covers an overview of the performance management tools, in-troducing how the counters are represented in these interfaces. MOShell and OSS-RC are tools used in this study. Tools were selected because the MOShell is Ericsson's inter-nal management tool and OSS-RC is a tool designed for customers.