987 resultados para Fractures surgery


Relevância:

60.00% 60.00%

Publicador:

Resumo:

Primary rib tumors constitute a rare entity and have only seldom been studied separately. In a retrospective study based on 21 cases, with the help of the literature, we try to specify the specific problems encountered with rib tumors and the therapeutic consequences that follow. Our series comprises 10 benign tumors, 3 malignant tumors and 8 cartilaginous tumors. The benign tumors were resected and all the patients recovered uneventfully. One of the patients died of a plasmocytoma 92 months after resection. Among the cartilaginous tumors, we observed two recurrences after 9 and 24 months from which the patient died eventually at 20 and 72 months after resection. The histologic diagnosis of a rib tumor must be made through an excisional biopsy. Cartilaginous tumors are potentially malignant. They must be treated as malignant tumors by radical resection and primary reconstruction. The long-term follow-up of every patient carrying a rib tumor is mandatory because of the risk of late recurrence.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The aim of this study was to prospectively evaluate the accuracy and predictability of new three-dimensionally preformed AO titanium mesh plates for posttraumatic orbital wall reconstruction.We analyzed the preoperative and postoperative clinical and radiologic data of 10 patients with isolated blow-out orbital fractures. Fracture locations were as follows: floor (N = 7; 70%), medial wall (N = 1; 1%), and floor/medial wall (N = 2; 2%). The floor fractures were exposed by a standard transconjunctival approach, whereas a combined transcaruncular transconjunctival approach was used in patients with medial wall fractures. A three-dimensional preformed AO titanium mesh plate (0.4 mm in thickness) was selected according to the size of the defect previously measured on the preoperative computed tomographic (CT) scan examination and fixed at the inferior orbital rim with 1 or 2 screws. The accuracy of plate positioning of the reconstructed orbit was assessed on the postoperative CT scan. Coronal CT scan slices were used to measure bony orbital volume using OsiriX Medical Image software. Reconstructed versus uninjured orbital volume were statistically correlated.Nine patients (90%) had a successful treatment outcome without complications. One patient (10%) developed a mechanical limitation of upward gaze with a resulting handicapping diplopia requiring hardware removal. Postoperative orbital CT scan showed an anatomic three-dimensional placement of the orbital mesh plates in all of the patients. Volume data of the reconstructed orbit fitted that of the contralateral uninjured orbit with accuracy to within 2.5 cm(3). There was no significant difference in volume between the reconstructed and uninjured orbits.This preliminary study has demonstrated that three-dimensionally preformed AO titanium mesh plates for posttraumatic orbital wall reconstruction results in (1) a high rate of success with an acceptable rate of major clinical complications (10%) and (2) an anatomic restoration of the bony orbital contour and volume that closely approximates that of the contralateral uninjured orbit.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Isolated avulsion fracture of the peroneus longus tendon insertion at the base of the first metatarsal is very rare. Similar to most avulsion fractures that result from excessive strain at a tendon or ligament insertion, this type of injury is caused by the strong tension exerted by the peroneus longus tendon. The mechanisms leading to this lesion and treatment options are not clearly defined. We present the case of an isolated minimally displaced intra-articular avulsion fracture at the plantar lateral base of the first metatarsal. Faced with a painful non-union following conservative treatment we considered excision of the bony fragment and first tarsometatarsal arthrodesis. This leads to a favourable functional outcome.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

A group of nine patients with a diaphyseal fracture of the humerus and treated with retrograde nailing were studied with a mean follow-up of 15.3 months. Six patients with a humeral fracture without neurological deficit showed a good shoulder and elbow mobility at the last visit. Three patients with neurological lesion preoperatively suffer from a diminished range of movement not related to the surgical procedure. During the operation and postoperatively we found no complication related to the implant and more precisely we could not find a iatrogenic fracture or nervous lesion except one intraoperative lesion of the radial nerve probably related to an important traction movement during reduction with complete remission. Consolidation has been achieved for all fractures but one. This patient suffers from a lesion of the brachial plexus with complete plegia of the arm and a vascular lesion. This patient had to be reoperated for an atrophic non-union by bone grafting and plate fixation. The retrograde nail is a good implant and must be considered in our treatment plans as much as conservative treatment or surgical treatment with plating, anterograde nailing or the use of an external fixator. Only then will we be able to give to the patient the most adapted treatment for his fracture.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

PURPOSE: To review, retrospectively, the possible causes of sub- or intertrochanteric fractures after screw fixation of intracapsular fractures of the proximal femur. METHODS: Eighty-four patients with an intracapsular fracture of proximal femur were operated between 1995 and 1998 by using three cannulated 6.25 mm screws. The screws were inserted in a triangular configuration, one screw in the upper part of the femoral neck and two screws in the inferior part. Between 1999 and 2001, we use two screws proximally and one screw distally. RESULTS: In the first series, two patients died within one week after operation. Sixty-four fractures healed without problems. Four patients developed an atrophic non-union; avascular necrosis of the femoral head was found in 11 patients. Three patients (3.6%) suffered a sub- and/or intertrochanteric fracture after a mean postoperative time of 30 days, in one case without obvious trauma. In all three cases surgical revision was necessary. Between 1999 and 2001 we did not observe any fracture after screwing. CONCLUSION: Two screws in the inferior part of the femoral neck create a stress riser in the subtrochanteric region, potentially inducing a fracture in the weakened bone. For internal fixation for proximal intracapsular femoral fracture only one screw must be inserted in the inferior part of neck.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

OBJECTIVE: To describe the epidemiology, the surgical treatment, the microbiology, the antibiotic prophylaxis and the outcome of patients with the most severe type of open fractures. METHODS: Retrospective chart reviews of patients with Gustilo type III open fracture admitted to an university hospital in Switzerland between January 2007 and December 2011. The patient's and fracture's characteristics, surgery, antibiotic prophylaxis, and microbiology findings at the initial and at the revision surgery were described. RESULTS: Thirty patients were included (83% male, mean age 41 years). More than half of the patients had polytrauma. In all patients, debridement and stabilization surgery (70% using external fixation) were performed at admission. Soft tissue reconstruction was performed in 87% and in 23% immediate bone graft was performed. Antibiotic prophylaxis were given in all patients for a median duration of 9 days (60% received amoxicillin/clavulanic acid). Positive bacterial culture was found in 53% of the patients at initial surgery and in 88% at revision surgery. At initial and revision surgery, 47% and 88% of the pathogens were amoxicillin/clavulanic acid-resistant. Treatment outcome was favorable in 24 of 30 patients (80%) and in six cases (20%) an amputation had to be performed. None of the patients had chronic bone infection. CONCLUSIONS: Positive cultures were found often in open fractures. Amoxicillin/clavulanic acid which is often mentioned in many guidelines as prophylaxis in open fractures does not cover the most common isolated organisms. The combination of surgery and antibiotic prophylaxis leads to good outcome in Gustilo type III fracture.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

BACKGROUND Closed reduction and pinning is the accepted treatment choice for dislocated supracondylar humeral fractures in children (SCHF). Rates of open reduction, complications and outcome are reported to be dependent on delay of surgery. We investigated whether delay of surgery had influence on the incidence of open reduction, complications and outcome of surgical treatment of SCHFs in the authors' institution. METHODS Three hundred and forty-one children with 343 supracondylar humeral fractures (Gartland II: 144; Gartland III: 199) who underwent surgery between 2000 and 2009 were retrospectively analysed. The group consisted of 194 males and 149 females. The average age was 6.3 years. Mean follow-up was 6.2 months. Time interval between trauma and surgical intervention was determined using our institutional database. Clinical and radiographical data were collected for each group. Influence of delay of treatment on rates of open reduction, complications and outcome was calculated using logistic regression analysis. Furthermore, patients were grouped into 4 groups of delay (<6 h, n = 166; 6-12 h, n = 95; 12-24 h, n = 68; >24 h, n = 14) and the aforementioned variables were compared among these groups. RESULTS The incidence of open procedures in 343 supracondylar humeral fractures was 2.6 %. Complication rates were similar to the literature (10.8 %) primarily consisting of transient neurological impairments (9.0 %) which all were fully reversible by conservative treatment. Poor outcome was seen in 1.7 % of the patients. Delay of surgical treatment had no influence on rates of open surgery (p = 0.662), complications (p = 0.365) or poor outcome (p = 0.942). CONCLUSIONS In this retrospective study delay of treatment of SCHF did not have significant influence on the incidence of open reduction, complications, and outcome. Therefore, in SCHF with sufficient blood perfusion and nerve function, elective treatment is reasonable to avoid surgical interventions in the middle of the night which are stressful and wearing both for patients and for surgeons. LEVEL OF EVIDENCE III (retrospective comparative study).

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The aim of this study was to use mechanical and photoelastic tests to compare the performance of cannulated screws with other fixation methods in mandibular symphysis fractures. Ten polyurethane mandibles were allocated to each group and fixed as follows: group PRP, 2 perpendicular miniplates; group PLL, 1 miniplate and 1 plate, parallel; and group CS, 2 cannulated screws. Vertical linear loading tests were performed. The differences between mean values were analyzed with the Tukey test. The photoelastic test was carried out using a polariscope. The results revealed differences between the CS and PRP groups at 1, 3, 5, and 10 millimeters of displacement. The photoelastic test confirmed higher stress concentration in all groups close to the mandibular base, whereas the CS group showed it throughout the region assessed. Conical cannulated screws performed well in mechanical and photoelastic tests.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

To perform a comparative evaluation of the mechanical resistance of simulated fractures of the mandibular body which were repaired using different fixation techniques with two different brands of 2.0 mm locking fixation systems. Four aluminum hemimandibles with linear sectioning simulating a mandibular body fracture were used as the substrates and were fixed using the two techniques and two different brands of fixation plate. These were divided into four groups: groups I and II were fixed with one four-hole plate, with four 6 mm screws in the tension zone and one four-hole plate, with four 10 mm screws in the compression zone; and groups III and IV were fixed with one four-hole plate with four 6 mm screws in the neutral zone. Fixation plates manufactured by Tóride were used for groups I and III, and by Traumec for groups II and IV. The hemimandibles were submitted to vertical, linear load testing in an Instron 4411 servohydraulic mechanical testing unit, and the load/displacement (3 mm, 5 mm and 7 mm) and the peak loads were measured. Means and standard deviations were evaluated applying variance analysis with a significance level of 5%. The only significant difference between the brands was seen at displacements of 7 mm. Comparing the techniques, groups I and II showed higher mechanical strength than groups III and IV, as expected. For the treatment of mandibular linear body fracture, two locking plates, one in the tension zone and another in the compression zone, have a greater mechanical strength than a single locking plate in the neutral zone.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The aim of the present study was to compare four methods of fixation in mandibular body fractures. Mechanical and photoelastic tests were performed using polyurethane and photoelastic resin mandibles, respectively. The study groups contained the following: (I), two miniplates of 2.0 mm; (II) one 2.0 mm plate and an Erich arch bar; (III) one 2.4 mm plate and an Erich arch bar, and (IV) one 2.0 mm plate and one 2.4 mm plate. The differences between the mean values were analyzed using Tukey's test, the Mann-Whitney test and the Bonferroni correction. Group II recorded the lowest resistance, followed by groups I, IV and III. The photoelastic test confirmed the increase of tension in group II. The 2.4 mm system board in linear mandibular body fractures provided more resistance and the use of only one 2.0 mm plate in the central area of the mandible created higher tension.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

To develop Y-shaped plates with different thicknesses to be used in simulated fractures of the mandibular condyle. Ten plates were developed in Y shape, containing eight holes, and 30 synthetic polyurethane mandible replicas were developed for the study. The load test was performed on an Instron Model 4411 universal testing machine, applying load in the mediolateral and anterior-posterior positions on the head of the condyle. Two-way ANOVA with Tukey testing with a 5% significance level was used. It was observed that when the load was applied in the medial-lateral plate of greater thickness (1.5 mm), it gave the highest strength, while in the anteroposterior direction, the plate with the highest resistance was of the lesser thickness (0.6 mm). A plate with a thickness of 1.5 mm was the one with the highest average value for all displacements. In the anteroposterior direction, the highest values of resistance were seen in the displacement of 15 mm. After comparing the values of the biomechanical testing found in the scientific literature, it is suggested that the use of Y plates are suitable for use in subcondylar fractures within the limitations of the study.