986 resultados para File systems
Resumo:
To explore the feasibility of processing Compact Muon Solenoid (CMS) analysis jobs across the wide area network, the FIU CMS Tier-3 center and the Florida CMS Tier-2 center designed a remote data access strategy. A Kerberized Lustre test bed was installed at the Tier-2 with the design to provide storage resources to private-facing worker nodes at the Tier-3. However, the Kerberos security layer is not capable of authenticating resources behind a private network. As a remedy, an xrootd server on a public-facing node at the Tier-3 was installed to export the file system to the private-facing worker nodes. We report the performance of CMS analysis jobs processed by the Tier-3 worker nodes accessing data from a Kerberized Lustre file. The processing performance of this configuration is benchmarked against a direct connection to the Lustre file system, and separately, where the xrootd server is near the Lustre file system.
Resumo:
Introdução: Em Portugal a realidade actual, clínica e financeira do exercício da Medicina Dentária é bem distinta da do final do séc. XX devido à pletora de Médicos Dentistas e à baixa de honorários por acto Médico registada nos últimos anos. Objectivos: Este trabalho teve como objectivo perceber um pouco sobre os detalhes a ter em consideração aquando da abertura de uma clínica centrada na realização de tratamentos na área da Endodontia, e como publicitá-la de forma legal e apelativa. Pretende-se depois também estimar o custo mínimo para a realização de tratamentos Endodonticos com diferentes equipamentos e comparar a eficácia entre tratamentos usando ferramentas diferentes. Materiais e Métodos: Foram usadas como fontes de pesquisa para o presente trabalho bases de dados como a PubMed, B-On e Cochrane Library. Foi também usado o Google. Para pesquisa no PubMed foram usados vários descritores MeSH, como “Commerce”, “Dentistry”, “Endodontics”, “Management” e “Marketing”. Foram também usadas diversas palavras-chave no PubMed e nos outros motores de pesquisa, como “Anesthesia”, “Dental Office”, “Files”, “Irrigation”, “Magnification”, “Microscope”, “Obturation Systems” e “Rotatory Systems”. As pesquisas foram filtradas para serem apresentados apenas resultados entre 2011 e 2016, sendo este filtro retirado só quando não eram encontrados resultados satisfatórios ou relevantes para os temas discutidos no trabalho. Foram obtidos 3927 artigos e seleccionados 24. A inclusão destes artigos foi feita tendo em conta as suas fontes bibliográficas e a qualidade dos estudos a que se reportavam. Foram excluídos artigos que se reportavam a estudos muito antigos ou a tecnologias ultrapassadas, como sistemas de limas antigos. Conclusões: As novas tecnologias usadas para tratamento Endodontico, apesar de dispendiosas, melhoram muito o atendimento ao paciente.
Resumo:
In a general purpose cloud system efficiencies are yet to be had from supporting diverse applications and their requirements within a storage system used for a private cloud. Supporting such diverse requirements poses a significant challenge in a storage system that supports fine grained configuration on a variety of parameters. This paper uses the Ceph distributed file system, and in particular its global parameters, to show how a single changed parameter can effect the performance for a range of access patterns when tested with an OpenStack cloud system.
Resumo:
P>AimTo compare the efficacy of different digital radiographic imaging systems for determining the length of endodontic files.MethodologyK-type endodontic files were introduced into the canals of 40 extracted human permanent single-rooted teeth and fixed in place at random lengths. The teeth were radiographed using Digora Optime (R), CygnusRay MPS (R) and CDR Wireless (R) digital imaging systems. Six observers measured every file length in all the images and repeated this procedure in 50% of the image samples, and assigned a score to the level of difficulty found. Analysis of variance for differences between digital systems and Tukey's test were performed. The level of intraobserver agreement was measured by intraclass correlation. The assigned scores were evaluated by Kruskal-Wallis and Dunn's tests.ResultsThe CDR Wireless values did not differ significantly from the actual lengths and the CygnusRay MPS values. The Digora Optime system was significantly different from the others and overestimated the values (P < 0.05). The Digora Optime was significantly easier to use for taking measurements and the CygnusRay MPS the most difficult (P < 0.05). All digital radiographic imaging systems showed excellent agreement with the Intraclass Correlation Coefficient > 0.95.ConclusionsThe three digital radiographic imaging systems were precise. The CDR Wireless system was significantly more accurate in determining endodontic file lengths, and similarly to Digora Optime, was considered the least difficult to use when assessing endodontic file lengths.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Includes bibliographical references.
Resumo:
Originally presented as the author's thesis, University of Illinois at Urbana-Champaign.
Resumo:
"January 1998."
Resumo:
Enterprise System (ES) implementation and management are knowledge intensive tasks that inevitably draw upon the experience of a wide range of people with diverse knowledge capabilities. Knowledge Management (KM) has been identified as a critical success factor in ES projects. Despite the recognized importance of managing knowledge for ES benefits realization, systematic attempts to conceptualize KM-structures have been few. Where the adequacy of KM-structures is assessed, the process and measures are typically idiosyncratic and lack credibility. Using the ‘KM-process’, itself based in sociology of knowledge, this paper conceptualizes four main constructs to measure the adequacy of KM-structures. The SEM model is tested using 310 responses gathered from 27 ES installations that had implemented SAP R/3. The findings reveal six constructs for KM-structure. Furthermore, the paper demonstrates the application of KM-structures in the context of ES using the Adaptive Structuration Theory. The results demonstrate that having adequate KM-structures in place, while necessary, is not sufficient. These rules and resources must be appropriated to have greater positive influence on the Enterprise System. Furthermore, the study provides empirical support for knowledge-based theory by illustrating the importance of knowledge use/re-use (vs. knowledge creation) as the most important driver in the process of KM.
Resumo:
The business value of Enterprise Resource Planning systems (ERP systems), and in general large software implementations, has been extensively debated in both popular press and in the academic literature for over two decades. Organisations invest enormous sums of money and resources in Enterprise Resource Planning systems (and related infrastructure), presumably expecting positive impacts to the organisation and its functions. Some studies have reported large productivity improvements and substantial benefits from ERP systems, while others have reported that ERP systems have not had any bottom-line impact. This paper discusses initial findings from a study that focuses on identifying and assessing important ERP impacts in 23 Australian public sector organizations.
Resumo:
Experts’ views and commentary have been highly respected in every discipline. However, unlike traditional disciplines like medicine, mathematics and engineering, Information System (IS) expertise is difficult to define. This paper attempts to understand the characteristics of IS-expert through a comprehensive literature review of analogous disciplines and then derives a formative research model with three main constructs. Further, this research validates the formative model to identify the characteristics of expertise using data gathered from 220 respondents using a contemporary Information System. Finally this research demonstrates how individuals with different levels of expertise differ in their views in relation to system evaluations.
Resumo:
Digital human modeling (DHM) systems underwent significant development within the last years. They achieved constantly growing importance in the field of ergonomic workplace design, product development, product usability, ergonomic research, ergonomic education, audiovisual marketing and the entertainment industry. They help to design ergonomic products as well as healthy and safe socio-technical work systems. In the domain of scientific DHM systems, no industry specific standard interfaces are defined which could facilitate the exchange of 3D solid body data, anthropometric data or motion data. The focus of this article is to provide an overview of requirements for a reliable data exchange between different DHM systems in order to identify suitable file formats. Examples from the literature are discussed in detail. Methods: As a first step a literature review is conducted on existing studies and file formats for exchanging data between different DHM systems. The found file formats can be structured into different categories: static 3D solid body data exchange, anthropometric data exchange, motion data exchange and comprehensive data exchange. Each file format is discussed and advantages as well as disadvantages for the DHM context are pointed out. Case studies are furthermore presented, which show first approaches to exchange data between DHM systems. Lessons learnt are shortly summarized. Results: A selection of suitable file formats for data exchange between DHM systems is determined from the literature review.
Resumo:
Substation Automation Systems have undergone many transformational changes triggered by improvements in technologies. Prior to the digital era, it made sense to confirm that the physical wiring matched the schematic design by meticulous and laborious point to point testing. In this way, human errors in either the design or the construction could be identified and fixed prior to entry into service. However, even though modern secondary systems today are largely computerised, we are still undertaking commissioning testing using the same philosophy as if each signal were hard wired. This is slow and tedious and doesn’t do justice to modern computer systems and software automation. One of the major architectural advantages of the IEC 61850 standard is that it “abstracts” the definition of data and services independently of any protocol allowing the mapping of them to any protocol that can meet the modelling and performance requirements. On this basis, any substation element can be defined using these common building blocks and are made available at the design, configuration and operational stages of the system. The primary advantage of accessing data using this methodology rather than the traditional position method (such as DNP 3.0) is that generic tools can be created to manipulate data. Self-describing data contains the information that these tools need to manipulate different data types correctly. More importantly, self-describing data makes the interface between programs robust and flexible. This paper proposes that the improved data definitions and methods for dealing with this data within a tightly bound and compliant IEC 61850 Substation Automation System could completely revolutionise the need to test systems when compared to traditional point to point methods. Using the outcomes of an undergraduate thesis project, we can demonstrate with some certainty that it is possible to automatically test the configuration of a protection relay by comparing the IEC 61850 configuration extracted from the relay against its SCL file for multiple relay vendors. The software tool provides a quick and automatic check that the data sets on a particular relay are correct according to its CID file, thus ensuring that no unexpected modifications are made at any stage of the commissioning process. This tool has been implemented in a Java programming environment using an open source IEC 61850 library to facilitate the server-client association with the relay.