929 resultados para Fast alcohol screening test


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Different solid composites made by mechanical dispersions of graphite particles into heated paraffin (from 65 to 80% graphite, in mass) were prepared and assessed in order to optimize their use in electrochemical and electroanalytical procedures for bioanalysis. Besides these, composites were also evaluated by thermoanalytical techniques aiming to study their conservation and long-term stability (over eight months without special care), among others. Best results were found at 80% m/m graphite in paraffin. Such electrode combines low-cost, stability, sensitivity, ease of maintenance and clearance, besides the possibilities of manufacture in many different forms and shapes (with or without modifications) and applicability in a wide range of pH. Electrochemical studies by different voltammetric techniques involving vitamins from complex B (riboflavin and pyridoxine) leaded to a better understanding about their electrooxidative processes onto carbon-composite electrodes, specially regarding reversibility and pH-dependence. Data were also acquired and optimized with analytical purposes, being square-wave voltammetry in pH 4.2 chosen by its many advantages. Good linearity between peak responses as function of concentration were reached from 5 to 43 μmol L-1 for riboflavin (peak at -0.257 V) and up to 8.5 × 10-4 mol L -1 for pyridoxine (peak at +1.04 V), best studied conditions; limits of detection (at an S/N of 3) for both analites showed to be circa 1.0 mol L-1. Different commercial samples were analyzed for riboflavin (EMS® complex B syrup) and pyridoxine (Citoneurin 5000 Merck® ampoules) providing 96.6% and 98.7% recoveries, respectively.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Coordenação de Aprefeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The present study is an analytical review of the methodology used in studies of efficacy of screening instruments to detect harmful use/ alcohol dependence according to the gender in population surveys. Systematic review of bibliography was done, using data from Web of Science, Pubmed and PsycInfo. Population studies were included without date range, in English, Spanish or Portuguese languages, with sample of adults, evaluating psychometric characteristics of any alcohol screening instrument, whereas studies in special population or under treatment as well as prevalence of alcohol consumption were excluded. Thirteen studies were selected to be included in the present review. According to the studies, the instruments that presented a better performance among men were AUDIT and its derivatives (6 studies) and CAGE (2 studies), whereas among women, AUDIT and its derivatives (7 studies), followed by CAGE (3 studies). The increase of consumption and problems related to alcohol use and its implications for public health indicate the need and urgency for adequacy of screening instruments to differences of gender in general population. The population surveys in the area are scarce. Furthermore, the found studies present heterogeneous methodology which makes accurate comparisons difficult.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Background: Many studies reported that brief interventions are effective in reducing excessive drinking. This study aimed to assess the efficacy of a protocol of brief intervention for college students (BASICS), delivered face-to-face, to reduce risky alcohol consumption and negative consequences. Methods: A systematic review with meta-analysis was performed by searching for randomized controlled trials (RCTs) in Medline, PsycInfo, Web of Science and Cochrane Library databases. A quality assessment of RCTs was made by using a validated scale. Combined mean effect sizes, using meta-analysis random-effects models, were calculated. Results: 18 studies were included in the review. The sample sizes ranged from 54 to 1275 (median = 212). All studies presented a good evaluation of methodological quality and four were found to have excellent quality. After approximately 12 months of follow-up, students receiving BASICS showed a significant reduction in alcohol consumption (difference between means = -1.50 drinks per week, 95% CI: -3.24 to -0.29) and alcohol-related problems (difference between means = -0.87, 95% CI: -1.58 to -0.20) compared to controls. Conclusions: Overall, BASICS lowered both alcohol consumption and negative consequences in college students. Gender and peer factors seem to play an important role as moderators of behavior change in college drinking. Characteristics of BASICS procedure have been evaluated as more favorable and acceptable by students in comparison with others interventions or control conditions. Considerations for future researches were discussed.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

BACKGROUND: Complete investigation of thrombophilic or hemorrhagic clinical presentations is a time-, apparatus-, and cost-intensive process. Sensitive screening tests for characterizing the overall function of the hemostatic system, or defined parts of it, would be very useful. For this purpose, we are developing an electrochemical biosensor system that allows measurement of thrombin generation in whole blood as well as in plasma. METHODS: The measuring system consists of a single-use electrochemical sensor in the shape of a strip and a measuring unit connected to a personal computer, recording the electrical signal. Blood is added to a specific reagent mixture immobilized in dry form on the strip, including a coagulation activator (e.g., tissue factor or silica) and an electrogenic substrate specific to thrombin. RESULTS: Increasing thrombin concentrations gave standard curves with progressively increasing maximal current and decreasing time to reach the peak. Because the measurement was unaffected by color or turbidity, any type of blood sample could be analyzed: platelet-poor plasma, platelet-rich plasma, and whole blood. The test strips with the predried reagents were stable when stored for several months before testing. Analysis of the combined results obtained with different activators allowed discrimination between defects of the extrinsic, intrinsic, and common coagulation pathways. Activated protein C (APC) predried on the strips allowed identification of APC-resistance in plasma and whole blood samples. CONCLUSIONS: The biosensor system provides a new method for assessing thrombin generation in plasma or whole blood samples as small as 10 microL. The assay is easy to use, thus allowing it to be performed in a point-of-care setting.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

BACKGROUND: Virtual reality testing of everyday activities is a novel type of computerized assessment that measures cognitive, executive, and motor performance as a screening tool for early dementia. This study used a virtual reality day-out task (VR-DOT) environment to evaluate its predictive value in patients with mild cognitive impairment (MCI). METHODS: One hundred thirty-four patients with MCI were selected and compared with 75 healthy control subjects. Participants received an initial assessment that included VR-DOT, a neuropsychological evaluation, magnetic resonance imaging (MRI) scan, and event-related potentials (ERPs). After 12 months, participants were assessed again with MRI, ERP, VR-DOT, and neuropsychological tests. RESULTS: At the end of the study, we differentiated two subgroups of patients with MCI according to their clinical evolution from baseline to follow-up: 56 MCI progressors and 78 MCI nonprogressors. VR-DOT performance profiles correlated strongly with existing predictive biomarkers, especially the ERP and MRI biomarkers of cortical thickness. CONCLUSIONS: Compared with ERP, MRI, or neuropsychological tests alone, the VR-DOT could provide additional predictive information in a low-cost, computerized, and noninvasive way.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

BACKGROUND Screening of aphasia in acute stroke is crucial for directing patients to early language therapy. The Language Screening Test (LAST), originally developed in French, is a validated language screening test that allows detection of a language deficit within a few minutes. The aim of the present study was to develop and validate two parallel German versions of the LAST. METHODS The LAST includes subtests for naming, repetition, automatic speech, and comprehension. For the translation into German, task constructs and psycholinguistic criteria for item selection were identical to the French LAST. A cohort of 101 stroke patients were tested, all of whom were native German speakers. Validation of the LAST was based on (1) analysis of equivalence of the German versions, which was established by administering both versions successively in a subset of patients, (2) internal validity by means of internal consistency analysis, and (3) external validity by comparison with the short version of the Token Test in another subset of patients. RESULTS The two German versions were equivalent as demonstrated by a high intraclass correlation coefficient of 0.91. Furthermore, an acceptable internal structure of the LAST was found (Cronbach's α = 0.74). A highly significant correlation (r = 0.74, p < 0.0001) between the LAST and the short version of the Token Test indicated good external validity of the scale. CONCLUSION The German version of the LAST, available in two parallel versions, is a new and valid language screening test in stroke.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Federal Highway Administration, Washington, D.C.