971 resultados para Energy Requirement


Relevância:

70.00% 70.00%

Publicador:

Resumo:

In order to determine the net energy, protein and macrominerals requirements of 70 to 120 day old, 52 female White New Zealand rabbits, weighing 1900g +/- 40g were used. At the beginning of the experimental period, 14 of the 52 young does were slaughtered and the 38 remaining animals were kept under two dietary management: ad libitum and restricted feeding. Slaughters were performed to determine each nutrient body content. The weight gain nutrient requirements depicted by the quantities of each nutrient stored into the body were obtained by applying the regression equation, which estimate the empty body nutrient content logarithm as a function of the empty body weight logarithm, as described by ARC (1980). By determining the heat production logarithm at the zero level of metabolizable energy intake, the maintenance net energy requirement was estimated to be 45.31 Kcal/day/Kg(0.75) the mean net energy. protein, calcium, phosphorous, sodium, magnesium and potassium requirements for each gram of weight gain per day were estimated to be, 2.51 Kcal, 0.21g, 0.02g, 0.005g, 0.001g, 0.0004g and 0.002g, respectively.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

The objective of this study was to determine models for ME requirements for broiler breeder pullets using the factorial method. The influence of the temperature on maintenance ME requirements was determined by experiments conducted in three environmental rooms with temperature kept constant at 15, 22, and 30°C, using the comparative slaughter technique. The energy requirements for weight gain were determined based on the body energy content and efficiency of energy utilization for weight gain. Two ME requirement models for each age were developed using the coefficients for maintenance and weight gain. The models for 3 to 8 wk were ME = W 0.75 (186.52 - 1.94T) + 2.47WG, and ME = W 0.75 (174 - 1.88T) + 2.83WG; for 9 to 14 wk, ME = W 0.75 (186.52 - 1.94T) + 2.69WG, and ME = W 0.75 (174 - 1.88T) + 2.50WG; and 15 to 20 wk, ME = W 0.75 (186.52 - 1.94T) + 2.76WG, and ME = W 0.75 (174 - 1.88T) + 3.24WG. In these equations, W is BW (kg), T is temperature (°C), and WG is daily weight gain (g). These models were compared to the breeder's recommendations in a feeding trial from 5 to 20 wk of age. Models 1 and 2 provided energy intakes that promoted BW smaller than the breeder's recommendation. However, all breeder pullets had weights above the standard recommendation. Model 2 gave the smallest ME intake and BW close to the standard recommendation and provided the best prediction of ME requirements.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

Two experiments were conducted to develop and evaluate a model to estimate ME requirements and determine Gompertz growth parameters for broilers. The first experiment was conducted to determine maintenance energy requirements and the efficiencies of energy utilization for fat and protein deposition. Maintenance ME (ME m) requirements were estimated to be 157.8, 112.1, and 127.2 kcal of ME/kg 0.75 per day for broilers at 13, 23, and 32°C, respectively. Environmental temperature (T) had a quadratic effect on maintenance requirements (ME m = 307.87 - 15.63T + 0.3105T 2; r 2= 0.93). Energy requirements for fat and protein deposition were estimated to be 13.52 and 12.59 kcal of ME/g, respectively. Based on these coefficients, a model was developed to calculate daily ME requirements: ME = BW 0.75 (307.87 - 15.63T + 0.3105 T 2) + 13.52 G f + 12.59 G p. This model considers live BW, the effects of environmental temperature, and fractional fat (G f) and protein (G p) deposition. The second experiment was carried out to estimate the growth parameters of Ross broilers and to collect data to evaluate the ME requirement model proposed. Live BW, empty feather-free carcass, weight of the feathers, and carcass chemical compositions were analyzed until 16 wk of age. Parameters of Gompertz curves for each component were estimated. Males had higher growth potential and higher capacity to deposit nutrients than females, except for fat deposition. Data of BW and body composition collected in this experiment were fitted into the energy model proposed herein and the equations described by Emmans (1989) and Chwalibog (1991). The daily ME requirements estimated by the model determined in this study were closer to the ME intake observed in this trial compared with other models. ©2005 Poultry Science Association, Inc.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

Models of daily energy requirement can help to establish better and more profitable feeding programs for poultry. Studies have been conducted at UNESP-Jaboticabal-Brazil with the aim of studying energy utilization in broiler breeders, laying hens, and broilers, and to establish metabolisable energy requirement models. The factorial approach was used to partition the energy requirements into maintenance, growth, and production components. The resulting models consider body weight, weight gain, egg production, and environmental temperature for the determination of the energy requirements of poultry. These models were evaluated in performance trials and provided good estimates. Therefore, they can be used to establish nutritional programs. The aim of this chapter is to describe the development of these models and to outline the results of our studies at UNESP.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

This study evaluated a nonlinear programming excel workbook PPFR (http://www.fmva.unesp.br/ppfr) for determining the optimum nutrient density and maximize margins. Two experiments were conducted with 240 one-day-old female chicks and 240 one-day-old male chicks distributed in 48 pens (10 chicks per pen, 4 replicates) in a completely randomized design. The treatments include the average price history (2009s and 2010s) for broiler increased and decreased by 25% or 50% (5 treatments to nonlinear feed formulation) and 1 linear feed formulation. Body gain, feed intake, feed conversion were measured at 21, 42 and 56 d of age. Chicks had ad libitum access to feed and water in floor pens with wood shavings as litter. The bio-economic Energy Conversion [BEC= (Total energy intake*Feed weighted cost per kg)/ (Weight gain*kg live chicken cost)] was more sensitive for measuring the bio-economic performance for broilers, and especially with better magnitude. This allowed a better assessment of profitability, the rate of growth and not just energy consumption, the production of broilers, by incorporating energy consumption, allowing for more sensitivity to the new index (BEC). The BEC was demonstrated that the principle of nonlinear formulation minimizes losses significantly (P<0.05), especially under unfavorable conditions the price of chicken in the market. Thus, when considering that a diet of energy supply shows up as the most expensive item of a formulation, it should compose necessarily the formula proposed for a bio-economic index. Thus, there is need to evaluate more accurately, not only the ingredients of a ration, but the impact of nutrients on the stability of a solution, mainly due to the energy requirement. This strategy promotes better accuracy for decision making under conditions of uncertainty, to find alternative post-formulation. From the above, both weight gain and feed conversion, as traditional performance indicators, cannot finalize or predict a performance evaluation of an economic system creating increasingly intense and competitive. Thus, the energy concentration of the diet becomes more important definition to feed formulator, by directly impact profit activity by interactions with the density of nutrients. This allowed a better evaluation of profitability, the rate of energy performance for broilers, by incorporating the energy consumption formula, allowing more sensitivity to the new index (BEC). These data show that nonlinear feed formulation is a toll to offer new opportunities for poultry production to improved profitability.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

A review of existing studies about LCA of PV systems has been carried out. The data from this review have been completed with our own figures in order to calculate the Energy Payback Time of double and horizontal axis tracking and fixed systems. The results of this metric span from 2 to 5 years for the latitude and global irradiation ranges of the geographical area comprised between −10◦ to 10◦ of longitude, and 30◦ to 45◦ of latitude. With the caution due to the uncertainty of the sources of information, these results mean that a GCPVS is able to produce back the energy required for its existence from 6 to 15 times during a life cycle of 30 years. When comparing tracking and fixed systems, the great importance of the PV generator makes advisable to dedicate more energy to some components of the system in order to increase the productivity and to obtain a higher performance of the component with the highest energy requirement. Both double axis and horizontal axis trackers follow this way, requiring more energy in metallic structure, foundations and wiring, but this higher contribution is widely compensated by the improved productivity of the system.

Relevância:

70.00% 70.00%

Publicador:

Resumo:

We investigate the energy optimization (minimization) for amplified links. We show that using the using a well-established analytic nonlinear signal-to-noise ratio noise model that for a simple amplifier model there are very clear, fiber independent, amplifier gains which minimize the total energy requirement. With a generalized amplifier model we establish the spacing for the optimum power per bit as well as the nonlinear limited optimum power. An amplifier spacing corresponding to 13 dB gain is shown to be a suitable compromise for practical amplifiers operating at the optimum nonlinear power. © 2014 Optical Society of America.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

In closed-die forging the flash geometry should be such as to ensure that the cavity is completely filled just as the two dies come into contact at the parting plane. If metal is caused to extrude through the flash gap as the dies approach the point of contact — a practice generally resorted to as a means of ensuring complete filling — dies are unnecessarily stressed in a high-stress regime (as the flash is quite thin and possibly cooled by then), which reduces the die life and unnecessarily increases the energy requirement of the operation. It is therefore necessary to carefully determine the dimensions of the flash land and flash thickness — the two parameters, apart from friction at the land, which control the lateral flow. The dimensions should be such that the flow into the longitudinal cavity is controlled throughout the operation, ensuring complete filling just as the dies touch at the parting plane. The design of the flash must be related to the shape and size of the forging cavity as the control of flow has to be exercised throughout the operation: it is possible to do this if the mechanics of how the lateral extrusion into the flash takes place is understood for specific cavity shapes and sizes. The work reported here is part of an ongoing programme investigating flow in closed-die forging. A simple closed shape (no longitudinal flow) which may correspond to the last stages of a real forging operation is analysed using the stress equilibrium approach. Metal from the cavity (flange) flows into the flash by shearing in the cavity in one of the three modes considered here: for a given cavity the mode with the least energy requirement is assumed to be the most realistic. On this basis a map has been developed which, given the depth and width of the cavity as well as the flash thickness, will tell the designer of the most likely mode (of the three modes considered) in which metal in the cavity will shear and then flow into the flash gap. The results of limited set of experiments, reported herein, validate this method of selecting the optimum model of flow into the flash gap.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

A low power keeper circuit using the concept of rate sensing has been proposed. The proposed technique reduces the amount of short circuit power dissipation in the domino gate by 70% compared to the conventional keeper technique. Also the total power-delay product is 26% lower compared to the previously reported techniques. The process tracking capability of the design enables the domino gate to achieve uniform delay across different process corners. This reduces the amount of short circuit power dissipation that occurs in the cascaded domino gates by 90%. The use of the proposed technique in the read path of a register file reduces the energy requirement by 26% as compared to the other keeper techniques. The proposed technique has been prototyped in 130nm CMOS technology.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Sugars perform two vital functions in plants: as compatible solutes protecting the cell against osmotic stress and as mobile source of immediate and long-term energy requirement for growth and development. The two sugars that occur commonly in nature are sucrose and trehalose. Sucrose comprises one glucose and one fructose molecule; trehalose comprises two glucose molecules. Trehalose occurs in significant amounts in insects and fungi which greatly outnumber the plants. Surprisingly, in plants trehalose has been found in barely detectable amounts, if at all, raising the question `why did nature select sucrose instead of trehalose as the mobile energy source and as storage sugar for the plants'? Modelling revealed that when attached to the ribbon-shaped beta-1,4 glucan a trehalose molecule is shaped like a hook. This suggests that the beta-1,4 glucan chains with attached trehalose will fail to align to form inter-chain hydrogen bonds and coalesce into a cellulose microfibril, as a result of which in trehalose-accumulating plant cells, the cell wall will tend to become leaky. Thus in plants an evolutionary selection was made in favour of sucrose as the mobile energy source. Genetic engineering of plant cells for combating abiotic stresses through microbial trehalose-producing genes is fraught with risk of damage to plant cell walls.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The economic prosperity and quality of life in a region are closely linked to the level of its per capita energy consumption. In India more than 70% of the total population inhabits rural areas and 85-90% of energy requirement is being met by bioresources. With dwindling resources, attention of planners is diverted to viable energy alternatives to meet the rural energy demand. Biogas as fuel is one such alternative, which can be obtained by anaerobic digestion of animal residues and domestic and farm wastes, abundantly available in the countryside. Study presents the techniques to assess biogas potential spatially using GIS in Kolar district, Karnataka State, India. This would help decision makers in selecting villages for implementing biogas programmes based on resource availability. Analyses reveal that the domestic energy requirement of more than 60% population can be met by biogas option. This is based on the estimation of the per capita requirement of gas for domestic purposes and availability of livestock residues.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

A dynamical instability is observed in experimental studies on micro-channels of rectangular cross-section with smallest dimension 100 and 160 mu m in which one of the walls is made of soft gel. There is a spontaneous transition from an ordered, laminar flow to a chaotic and highly mixed flow state when the Reynolds number increases beyond a critical value. The critical Reynolds number, which decreases as the elasticity modulus of the soft wall is reduced, is as low as 200 for the softest wall used here (in contrast to 1200 for a rigid-walled channel) The instability onset is observed by the breakup of a dye-stream introduced in the centre of the micro-channel, as well as the onset of wall oscillations due to laser scattering from fluorescent beads embedded in the wall of the channel. The mixing time across a channel of width 1.5 mm, measured by dye-stream and outlet conductance experiments, is smaller by a factor of 10(5) than that for a laminar flow. The increased mixing rate comes at very little cost, because the pressure drop (energy requirement to drive the flow) increases continuously and modestly at transition. The deformed shape is reconstructed numerically, and computational fluid dynamics (CFD) simulations are carried out to obtain the pressure gradient and the velocity fields for different flow rates. The pressure difference across the channel predicted by simulations is in agreement with the experiments (within experimental errors) for flow rates where the dye stream is laminar, but the experimental pressure difference is higher than the simulation prediction after dye-stream breakup. A linear stability analysis is carried out using the parallel-flow approximation, in which the wall is modelled as a neo-Hookean elastic solid, and the simulation results for the mean velocity and pressure gradient from the CFD simulations are used as inputs. The stability analysis accurately predicts the Reynolds number (based on flow rate) at which an instability is observed in the dye stream, and it also predicts that the instability first takes place at the downstream converging section of the channel, and not at the upstream diverging section. The stability analysis also indicates that the destabilization is due to the modification of the flow and the local pressure gradient due to the wall deformation; if we assume a parabolic velocity profile with the pressure gradient given by the plane Poiseuille law, the flow is always found to be stable.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

[ES]En este trabajo se propone el diseño técnico de una microrred eléctrica para la recarga domestica del vehículo eléctrico a partir de energías renovables. Para ello se realizará un estudio del emplazamiento de la instalación y con los datos obtenidos se decidirá la fuente de generación renovable más adecuada para satisfacer el requerimiento de energía para la recarga. A continuación se elegirán los componentes que completen la instalación.