911 resultados para Emission Computed-tomography


Relevância:

100.00% 100.00%

Publicador:

Resumo:

BACKGROUND: Neoadjuvant chemoradiation (CRT) therapy may result in significant tumor regression in patients with rectal cancer. Patients who develop complete tumor regression have been managed by treatment strategies that are alternatives to standard total mesorectal excision. Therefore, assessment of tumor response with positron emission tomography/computed tomography (PET/CT) after neoadjuvant treatment may offer relevant information for the selection of patients to receive alternative treatment strategies. METHODS: Patients with clinical T2 (cT2) through cT4NxM0 rectal adenocarcinoma were included prospectively. Neoadjuvant therapy consisted of 54 grays of radiation and 5-fluorouracil-based chemotherapy. Baseline PET/CT studies were obtained before CRT followed by PET/CT studies at 6 weeks and 12 weeks after the completion of CRT. Clinical assessment was performed at 12 weeks after CRT completion. PET/CT results were compared with clinical and pathologic data. RESULTS: In total, 99 patients were included in the study. Twenty-three patients were complete responders (16 had a complete clinical response, and 7 had a complete pathologic response). The PET/CT response evaluation at 12 weeks indicated that 18 patients had a complete response, and 81 patients had an incomplete response. There were 5 false-negative and 10 false-positive PET/CT results. PET/CT for the detection of residual cancer had 93% sensitivity, 53% specificity, a 73% negative predictive value, an 87% positive predictive value, and 85% accuracy. Clinical assessment alone resulted in an accuracy of 91%. PET/CT information may have detected misdiagnoses made by clinical assessment alone, improving overall accuracy to 96%. CONCLUSIONS: Assessment of tumor response at 12 weeks after CRT completion with PET/CT imaging may provide a useful additional tool with good overall accuracy for the selection of patients who may avoid unnecessary radical resection after achieving a complete clinical response. Cancer 2012;35013511. (C) 2011 American Cancer Society.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Choline positron emission tomography (PET)/computed tomography (CT) is a currently used diagnostic tool in restaging prostate cancer (PCa) patients with increasing prostate-specific antigen (PSA) after either radical prostatectomy (RP) or external-beam radiation therapy (EBRT). However, no final recommendations have been made on the use of this modality for patient management.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

We prospectively investigated the potential of positron emission tomography (PET) using the somatostatin receptor (SSTR) analogue ⁶⁸Ga-DOTATATE and 2-deoxy-2[¹⁸F]fluoro-D-glucose (¹⁸F-FDG) in diffuse parenchymal lung disease (DPLD). Twenty-six patients (mean age 68.9 ± 11.0 years) with DPLD were recruited for ⁶⁸Ga-DOTATATE and ¹⁸F-FDG combined PET/high-resolution computed tomography (HRCT) studies. Ten patients had idiopathic pulmonary fibrosis (IPF), 12 patients had nonspecific interstitial pneumonia (NSIP), and 4 patients had other forms of DPLD. Using PET, the pulmonary tracer uptake (maximum standardized uptake value [SUV(max)]) was calculated. The distribution of PET tracer was compared to the distribution of lung parenchymal changes on HRCT. All patients demonstrated increased pulmonary PET signal with ⁶⁸Ga-DOTATATE and ¹⁸F-FDG. The distribution of parenchymal uptake was similar, with both tracers corresponding to the distribution of HRCT changes. The mean SUV(max) was 2.2 ± 0.7 for ⁶⁸Ga-DOTATATE and 2.8 ± 1.0 (t-test, p  =  .018) for ¹⁸F-FDG. The mean ⁶⁸Ga-DOTATATE SUV(max) in IPF patients was 2.5 ± 0.9, whereas it was 2.0 ± 0.7 (p  =  .235) in NSIP patients. The correlation between ⁶⁸Ga-DOTATATE SUV(max) and gas transfer (transfer factor of the lung for carbon monoxide [TLCO]) was r  =  -.34 (p  =  .127) and r  =  -.49 (p  =  .028) between ¹⁸F-FDG SUV(max) and TLCO. We provide noninvasive in vivo evidence in humans showing that SSTRs may be detected in the lungs of patients with DPLD in a similar distribution to sites of increased uptake of ¹⁸F-FDG on PET.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Single photon emission with computed tomography (SPECT) hexamethylphenylethyleneamineoxime technetium-99 images were analyzed by an optimal interpolative neural network (OINN) algorithm to determine whether the network could discriminate among clinically diagnosed groups of elderly normal, Alzheimer disease (AD), and vascular dementia (VD) subjects. After initial image preprocessing and registration, image features were obtained that were representative of the mean regional tissue uptake. These features were extracted from a given image by averaging the intensities over various regions defined by suitable masks. After training, the network classified independent trials of patients whose clinical diagnoses conformed to published criteria for probable AD or probable/possible VD. For the SPECT data used in the current tests, the OINN agreement was 80 and 86% for probable AD and probable/possible VD, respectively. These results suggest that artificial neural network methods offer potential in diagnoses from brain images and possibly in other areas of scientific research where complex patterns of data may have scientifically meaningful groupings that are not easily identifiable by the researcher.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

18-Fluorodeoxyglucose (FDG-PET/CT) is an established imaging modality that has been proven to be of benefit in the management of aggressive B-cell non-Hodgkin's lymphoma, such as diffuse large B-cell lymphoma and advanced stage follicular lymphoma. The combination of anatomic and functional imaging afforded by FDG-PET/CT has led to superior sensitivity and specificity in the primary staging, restaging, and assessment of response to treatment of hematological malignancies when compared to FDG-PET and CT alone. The use of FDG-PET/CT for post treatment surveillance imaging remains controversial, and further study is needed to ascertain whether this modality is cost effective and appropriate for use in this setting.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The SPECT (Single Photon Emission Computed Tomography) systems are part of a medical image acquisition technology which has been outstanding, because the resultant images are functional images complementary to those that give anatomic information, such as X-Ray CT, presenting a high diagnostic value. These equipments acquire, in a non-invasive way, images from the interior of the human body through tomographic mapping of radioactive material administered to the patient. The SPECT systems are based on the Gamma Camera detection system, and one of them being set on a rotational gantry is enough to obtain the necessary data for a tomographic image. The images obtained from the SPECT system consist in a group of flat images that describe the radioactive distribution on the patient. The trans-axial cuts are obtained from the tomographic reconstruction techniques. There are analytic and iterative methods to obtain the tomographic reconstruction. The analytic methods are based on the Fourier Cut Theorem (FCT), while the iterative methods search for numeric solutions to solve the equations from the projections. Within the analytic methods, the filtered backprojection (FBP) method maybe is the simplest of all the tomographic reconstruction techniques. This paper's goal is to present the operation of the SPECT system, the Gamma Camera detection system, some tomographic reconstruction techniques and the requisites for the implementation of this system in a Nuclear Medicine service

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The use of ion microbeams as probes for computedtomography has proven to be a powerful tool for the three-dimensional characterization of specimens a few tens of micrometers in size. Compared to other types of probes, the main advantage is that quantitative information about mass density and composition can be obtained directly, using specific reconstruction codes. At the Centre d’Etudes Nucléaires de Bordeaux Gradignan (CENBG), this technique was initially developed for applications in cellular biology. However, the observation of the cell ultrastructure requires a sub-micron resolution. The construction of the nanobeamline at the Applications Interdisciplinaires des Faisceaux d’Ions en Region Aquitaine (AIFIRA) irradiation facility has opened new perspectives for such applications. The implementation of computedtomography on the nanobeamline of CENBG has required a careful design of the analysis chamber, especially microscopes for precise sample visualization, and detectors for scanning transmission ion microscopy (STIM) and for particle induced X-ray emission (PIXE). The sample can be precisely positioned in the three directions X, Y, Z and a stepper motor coupled to a goniometer ensures the rotational motion. First images of 3D tomography were obtained on a reference sample containing microspheres of certified diameter, showing the good stability of the beam and the sample stage, and the precision of the motion.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Thoracoscopic instrumented anterior spinal fusion for adolescent idiopathic scoliosis (AIS) has clinical benefits that include reduced pulmonary morbidity, postoperative pain, and improved cosmesis. However, quantitative data on radiological improvement of vertebral rotation using this method is lacking. This study’s objectives were to measure preoperative and postoperative axial vertebral rotational deformity at the curve apex in endoscopically-treated anterior-instrumented scoliosis patients using CT, and assess the relevance of these findings to clinically measured chest wall rib hump deformity correction. This is the first quantitative CT study to confirm that endoscopic anterior instrumented fusion for AIS substantially improves axial vertebral body rotational deformity at the apex of the curve. The margin of correction of 43% compares favourably with historically published figures of 24% for patients with posterior all-hook-rod constructs. CT measurements correlated significantly to the clinical outcome of rib hump deformity correction.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

X-ray computed tomography (CT) is a medical imaging technique that produces images of trans-axial planes through the human body. When compared with a conventional radiograph, which is an image of many planes superimposed on each other, a CT image exhibits significantly improved contrast although this is at the expense of reduced spatial resolution.----- A CT image is reconstructed mathematically from a large number of one dimensional projections of the chosen plane. These projections are acquired electronically using a linear array of solid-state detectors and an x ray source that rotates around the patient.----- X-ray computed tomography is used routinely in radiological examinations. It has also be found to be useful in special applications such as radiotherapy treatment planning and three-dimensional imaging for surgical planning.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

One of the primary treatment goals of adolescent idiopathic scoliosis (AIS) surgery is to achieve maximum coronal plane correction while maintaining coronal balance. However maintaining or restoring sagittal plane spinal curvature has become increasingly important in maintaining the long-term health of the spine. Patients with AIS are characterised by pre-operative thoracic hypokyphosis, and it is generally agreed that operative treatment of thoracic idiopathic scoliosis should aim to restore thoracic kyphosis to normal values while maintaining lumbar lordosis and good overall sagittal balance. The aim of this study was to evaluate CT sagittal plane parameters, with particular emphasis on thoracolumbar junctional alignment, in patients with AIS who underwent Video Assisted Thoracoscopic Spinal Fusion and Instrumentation (VATS). This study concluded that video-assisted thoracoscopic spinal fusion and instrumentation reliably increases thoracic kyphosis while preserving junctional alignment and lumbar lordosis in thoracic AIS.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Sixteen formalin-fixed foetal livers were scanned in vitro using a new system for estimating volume from a sequence of multiplanar 2D ultrasound images. Three different scan techniques were used (radial, parallel and slanted) and four volume estimation algorithms (ellipsoid, planimetry, tetrahedral and ray tracing). Actual liver volumes were measured by water displacement. Twelve of the sixteen livers also received x-ray computed tomography (CT) and magnetic resonance (MR) scans and the volumes were calculated using voxel counting and planimetry. The percentage accuracy (mean ± SD) was 5.3 ± 4.7%, −3.1 ± 9.6% and −0.03 ± 9.7% for ultrasound (radial scans, ray volumes), MR and CT (voxel counting) respectively. The new system may be useful for accurately estimating foetal liver volume in utero.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Despite the prominent use of the Suchey-Brooks (S-B) method of age estimation in forensic anthropological practice, it is subject to intrinsic limitations, with reports of differential inter-population error rates between geographical locations. This study assessed the accuracy of the S-B method to a contemporary adult population in Queensland, Australia and provides robust age parameters calibrated for our population. Three-dimensional surface reconstructions were generated from computed tomography scans of the pubic symphysis of male and female Caucasian individuals aged 15–70 years (n = 195) in Amira® and Rapidform®. Error was analyzed on the basis of bias, inaccuracy and percentage correct classification for left and right symphyseal surfaces. Application of transition analysis and Chi-square statistics demonstrated 63.9% and 69.7% correct age classification associated with the left symphyseal surface of Australian males and females, respectively, using the S-B method. Using Bayesian statistics, probability density distributions for each S-B phase were calculated, providing refined age parameters for our population. Mean inaccuracies of 6.77 (±2.76) and 8.28 (±4.41) years were reported for the left surfaces of males and females, respectively; with positive biases for younger individuals (<55 years) and negative biases in older individuals. Significant sexual dimorphism in the application of the S-B method was observed; and asymmetry in phase classification of the pubic symphysis was a frequent phenomenon. These results recommend that the S-B method should be applied with caution in medico-legal death investigations of Queensland skeletal remains and warrant further investigation of reliable age estimation techniques.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

In this work we used a 3D quantitative CT ultrasound imaging system to characterise polymer gel dosimeters. The system comprised of two identical 5 MHz 128 element phased-array ultrasound transducers co-axially aligned and submerged in water as a coupling agent. Rotational and translational movement of the gel dosimeter sample between the transducers were performed using a robotic arm. Ultrasound signals were generated and received using an Olympus Omniscan unit. Dose sensitivity of attenuation and time of flight ultrasonic parameters were assessed using this system.