147 resultados para EMC


Relevância:

20.00% 20.00%

Publicador:

Resumo:

O trabalho teve como objetivo avaliar a compatibilidade de enxertia de cultivares de pereiras sobre porta enxertos de marmeleiros 'Adam's e 'EMC'. O experimento foi desenvolvido em viveiro comercial da empresa Frutirol Agrícola Ltda, localizada no município de Vacaria - RS, a 980 m de altitude. Os porta enxertos de marmeleiros 'Adam's e 'EMC' foram enxertados no mês de julho de 2006 com as cultivares copa Danjou, Conference, Packham's Triumph, Abate Fetel e Rocha sobre os dois porta enxertos; Santa Maria, Benita, Foreli e Decana de Comice sobre o marmeleiro 'Adam's e, Clapp's Favourite e William's sobre 'EMC'. Utilizou-se a técnica de enxertia de garfagem dupla fenda, onde se enxertou ramos da cultivar copa com duas gemas sobre os respectivos porta enxertos, os quais apresentavam diâmetro médio de 8 mm. Em seguida foram amarrados com fita biodegradável BUDTAPE. Em julho de 2007 procederam-se as seguintes avaliações: diâmetro da copa e do porta enxerto (distantes 5 cm do ponto de enxertia), medido com auxílio de um paquímetro; altura de plantas (medida a partir do nível do solo até o ápice da planta); área da seção do tronco da copa e do porta enxerto foi obtida através da fórmula A = (? x (D/2)2) Sendo: A = área da seção do ramo (cm3); ? = 3,1416; D = Diâmetro do ramo principal (mm) e os resultados foram expressos em centímetros cúbicos; Os dados foram submetidos à análise de variância e posteriormente à comparação de médias através do teste de Tukey ao nível de 5% de probabilidade de erro. Os resultados demonstram que a cv. Danjou apresenta pouco vigor em relação as demais cvs. estudadas, para ambos os porta enxertos; plantas vigorosas apresentam menor diferença de diâmetro entre porta enxerto e copa; a cv. Conference apresenta-se mais vigorosa em relação às demais cvs. estudadas quando enxertadas sobre 'EMC'; a cv. William's apresenta incompatibilidade com o marmelo 'EMC'.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

In this paper, several aspects of high frequency related issues of modern AC motor drive systems, such as common mode voltage, shaft voltage and resultant bearing current and leakage currents, have been discussed. Conducted emission is a major problem in modern motor drives that produce undesirable effects on electronic devices. In modern power electronic systems, increasing power density and decreasing cost and size of system are market requirements. Switching losses, harmonics and EMI are the key factors which should be considered at the beginning stage of a design to optimise a drive system.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Electromagnetic compatibility of power electronic systems becomes an engineering discipline and it should be considered at the beginning stage of a design. Thus, a power electronics design becomes more complex and challenging and it requires a good communication between EMI and Power electronics experts. Three major issues in designing a power electronic system are Losses, EMI and Harmonics. These issues affect system cost, size, efficiency and quality and it is a tradeoff between these factors when we design a power converter.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This paper discusses how internet services can be brought one step closer to the rural dispersed communities by improving wireless broadband communications in those areas. To accomplish this objective we describe the use of an innovative Multi-User-Single-Antenna for MIMO (MUSA-MIMO) technology using the spectrum currently allocated to analogue TV. MUSA-MIMO technology can be considered as a special case of MIMO technology, which is beneficial when provisioning reliable and high-speed communication channels. This paper describes channel modelling techniques to characterise the MUSA-MIMO system allowing an effective deployment of this technology. Particularly, it describes the development of a novel MUSA MIMO channel model that takes into account temporal variations in the rural wireless environment. This can be considered as a novel approach tailor-maid to rural Australia for provisioning efficient wireless broadband communications.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This thesis reports on the investigations, simulations and analyses of novel power electronics topologies and control strategies. The research is financed by an Australian Research Council (ARC) Linkage (07-09) grant. Therefore, in addition to developing original research and contributing to the available knowledge of power electronics, it also contributes to the design of a DC-DC converter for specific application to the auxiliary power supply in electric trains. Specifically, in this regard, it contributes to the design of a 7.5 kW DC-DC converter for the industrial partner (Schaffler and Associates Ltd) who supported this project. As the thesis is formatted as a ‘thesis by publication’, the contents are organized around published papers. The research has resulted in eleven papers, including seven peer reviewed and published conference papers, one published journal paper, two journal papers accepted for publication and one submitted journal paper (provisionally accepted subject to few changes). In this research, several novel DC-DC converter topologies are introduced, analysed, and tested. The similarity of all of the topologies devised lies in their ‘current circulating’ switching state, which allows them to store some energy in the inductor, as extra inductor current. The stored energy may be applied to enhance the performance of the converter in the occurrence of load current or input voltage disturbances. In addition, when there is an alternating load current, the ability to store energy allows the converter to perform satisfactorily despite frequently and highly varying load current. In this research, the capability of current storage has been utilised to design topologies for specific applications, and the enhancement of the performance of the considered applications has been illustrated. The simplest DC-DC converter topology, which has a ‘current circulating’ switching state, is the Positive Buck-Boost (PBB) converter (also known as the non-inverting Buck-Boost converter). Usually, the topology of the PBB converter is operating as a Buck or a Boost converter in applications with widely varying input voltage or output reference voltage. For example, in electric railways (the application of our industrial partner), the overhead line voltage alternates from 1000VDC to 500VDC and the required regulated voltage is 600VDC. In the course of this research, our industrial partner (Schaffler and Associates Ltd) industrialized a PBB converter–the ‘Mudo converter’–operating at 7.5 kW. Programming the onboard DSP and testing the PBB converter in experimental and nominal power and voltage was part of this research program. In the earlier stages of this research, the advantages and drawbacks of utilization of the ‘current circulating’ switching state in the positive Buck-Boost converter were investigated. In brief, the advantages were found to be robustness against input voltage and current load disturbances, and the drawback was extra conduction and switching loss. Although the robustness against disturbances is desirable for many applications, the price of energy loss must be minimized to attract attention to the utilization of the PBB converter. In further stages of this research, two novel control strategies for different applications were devised to minimise the extra energy loss while the advantages of the positive Buck-Boost converter were fully utilized. The first strategy is Smart Load Controller (SLC) for applications with pre-knowledge or predictability of input voltage and/or load current disturbances. A convenient example of these applications is electric/hybrid cars where a master controller commands all changes in loads and voltage sources. Therefore, the master controller has a pre-knowledge of the load and input voltage disturbances so it can apply the SLC strategy to utilize robustness of the PBB converter. Another strategy aiming to minimise energy loss and maximise the robustness in the face of disturbance is developed to cover applications with unexpected disturbances. This strategy is named Dynamic Hysteresis Band (DHB), and is used to manipulate the hysteresis band height after occurrence of disturbance to reduce dynamics of the output voltage. When no disturbance has occurred, the PBB converter works with minimum inductor current and minimum energy loss. New topologies based on the PBB converter have been introduced to address input voltage disturbances for different onboard applications. The research shows that the performance of applications of symmetrical/asymmetrical multi-level diode-clamped inverters, DC-networks, and linear-assisted RF amplifiers may be enhanced by the utilization of topologies based on the PBB converter. Multi-level diode-clamped inverters have the problem of DC-link voltage balancing when the power factor of their load closes to unity. This research has shown that this problem may be solved with a suitable multi-output DC-DC converter supplying DClink capacitors. Furthermore, the multi-level diode-clamped inverters supplied with asymmetrical DC-link voltages may improve the quality of load voltage and reduce the level of Electromagnetic Interference (EMI). Mathematical analyses and experiments on supplying symmetrical and asymmetrical multi-level inverters by specifically designed multi-output DC-DC converters have been reported in two journal papers. Another application in which the system performance can be improved by utilization of the ‘current circulating’ switching state is linear-assisted RF amplifiers in communicational receivers. The concept of ‘linear-assisted’ is to divide the signal into two frequency domains: low frequency, which should be amplified by a switching circuit; and the high frequency domain, which should be amplified by a linear amplifier. The objective is to minimize the overall power loss. This research suggests using the current storage capacity of a PBB based converter to increase its bandwidth, and to increase the domain of the switching converter. The PBB converter addresses the industrial demand for a DC-DC converter for the application of auxiliary power supply of a typical electric train. However, after testing the industrial prototype of the PBB converter, there were some voltage and current spikes because of switching. To attenuate this problem without significantly increasing the switching loss, the idea of Active Gate Signalling (AGS) is presented. AGS suggests a smart gate driver that selectively controls the switching process to reduce voltage/current spikes, without unacceptable reduction in the efficiency of switching.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Constructed wetlands are among the most common Water Sensitive Urban Design (WSUD) measures for stormwater treatment. These systems have been extensively studied to understand their performance and influential treatment processes. Unfortunately, most past studies have been undertaken considering a wetland system as a lumped system with a primary focus on the reduction of the event mean concentration (EMC) values of specific pollutant species or total pollutant load removal. This research study adopted an innovative approach by partitioning the inflow runoff hydrograph and then investigating treatment performance in each partition and their relationships with a range of hydraulic factors. The study outcomes confirmed that influenced by rainfall characteristics, the constructed wetland displays different treatment characteristics for the initial and later sectors of the runoff hydrograph. The treatment of small rainfall events (<15 mm) is comparatively better at the beginning of runoff events while the trends in pollutant load reductions for large rainfall events (>15 mm) are generally lower at the beginning and gradually increase towards the end of rainfall events. This highlights the importance of ensuring that the inflow into a constructed wetland has low turbulence in order to achieve consistent treatment performance for both, small and large rainfall events.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

PURPOSE Brivanib, an oral, multi-targeted tyrosine kinase inhibitor with activity against vascular endothelial growth factor (VEGF) and fibroblast growth factor receptor (FGFR) was investigated as a single agent in a phase II trial to assess the activity and tolerability in recurrent or persistent endometrial cancer (EMC). PATIENTS AND METHODS Eligible patients had persistent or recurrent EMC after receiving one to two prior cytotoxic regimens, measurable disease, and performance status of ≤2. Treatment consisted of brivanib 800 mg orally every day until disease progression or prohibitive toxicity. Primary endpoints were progression-free survival (PFS) at six months and objective tumor response. Expression of multiple angiogenic proteins and FGFR2 mutation status was assessed. RESULTS Forty-five patients were enrolled. Forty-three patients were eligible and evaluable. Median age was 64 years. Twenty-four patients (55.8%) received prior radiation. Median number of cycles was two (range 1-24). No GI perforations but one rectal fistula were seen. Nine patients had grade 3 hypertension, with one experiencing grade 4 confusion. Eight patients (18.6%; 90% CI 9.6%-31.7%) had responses (one CR and seven PRs), and 13 patients (30.2%; 90% CI 18.9%-43.9%) were PFS at six months. Median PFS and overall survival (OS) were 3.3 and 10.7 months, respectively. When modeled jointly, VEGF and angiopoietin-2 expression may diametrically predict PFS. Estrogen receptor-α (ER) expression was positively correlated with OS. CONCLUSION Brivanib is reasonably well tolerated and worthy of further investigation based on PFS at six months in recurrent or persistent EMC.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Background Encephalomyocarditis (EMC) caused by EMC virus (EMCV) was diagnosed in a 5-month-old splenectomised calf, which died suddenly on an experimental farm that had a high infestation of rodents. Results At postmortem examination, the lungs were dark purple and diffusely congested. On histological examination, the calf had severe necrotising myocarditis. EMCV was isolated from the heart. The polyprotein gene of the EMCV isolate was amplified by PCR and had 85–91% identity with published EMCV sequences, including 89% identity with isolates from Queensland. On phylogenetic analysis, the polyprotein gene had highest sequence identity with South Korean EMCV strain, CBNU. Conclusion This is the first report of naturally occurring EMC in cattle in Australia and the first report of naturally occurring bovine EMC from which EMCV has been isolated.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A phenomenological model of spin sharing by the constituents of a proton is constructed, based on the recent EMC measurement of the spin dependent structure function and knowledge of the unpolarized parton densities.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Multilevel inverters with dodecagonal (12-sided polygon) voltage space vector (SV) structures have advantages like extension of linear modulation range, elimination of fifth and seventh harmonics in phase voltages and currents for the full modulation range including extreme 12-step operation, reduced device voltage ratings, lesser dv/dt stresses on devices and motor phase windings resulting in lower EMI/EMC problems, and lower switching frequency-making it more suitable for high-power drive applications. This paper proposes a simple method to obtain pulsewidth modulation (PWM) timings for a dodecagonal voltage SV structure using only sampled reference voltages. In addition to this, a carrier-based method for obtaining the PWM timings for a general N-level dodecagonal structure is proposed in this paper for the first time. The algorithm outputs the triangle information and the PWM timing values which can be set as the compare values for any carrier-based hardware PWM module to obtain SV PWM like switching sequences. The proposed method eliminates the need for angle estimation, computation of modulation indices, and iterative search algorithms that are typical in multilevel dodecagonal SV systems. The proposed PWM scheme was implemented on a five-level dodecagonal SV structure. Exhaustive simulation and experimental results for steady-state and transient conditions are presented to validate the proposed method.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The Ultra Wide Band (UWB) system has been a subject of research in the last few years due to its utility in various high power electromagnetic applications. Due to its simplicity in design and fabrication, the Half Impulse Radiating Antenna (HIRA) based UWB system has attracted many researchers. Effectiveness of a UWB system, in terms of the bandwidth of the radiated pulse depends on the duration of the radiated field which is typically of sub nanosecond regime. This duration in turn depends on the closure time of the switch used in the UWB pulsed power source. This paper presents the work carried out on the pressurised gas switch of a 50 kV pulsed power system of a HIRA based UWB system. The aim of the present work is to establish the relationship between the pulser switch breakdown voltage and gas pressure, rise time and gas pressure as well as the dependency of the Pulse Repetition Rate (PRR) on the switch breakdown voltage.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Electromagnetic shielding has become important for various electrical systems because of the electromagnetic pollution caused by the large scale use of electronic devices operating at different frequencies and power levels. Traditionally used metallic shields lack flexibility and hence may not be the right choice for certain applications. In such situations, filled polymer composites provide a good alternative for electromagnetic shielding applications. Being polymer based, they are easy to manufacture and can be molded into the required geometry and shape. In this study, the shielding properties of multiwalled carbon nanotubes and carbon nanofibers filled silicone rubber are studied. The conductivity and the shielding effectiveness of the composites were measured at different filler loadings. Both the fillers are able to make the base polymer conducting even at very low filler loadings. The conductivity and the shielding effectiveness improved when the filler loading was above the percolation threshold.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Visa a atender solicitação do Presidente da Comissão de Finanças e Tributação – CFT, Deputado Mário Feitoza, acerca da admissibilidade da Emenda na Comissão - EMC nº 1, de 2013, de autoria do Deputado Rubens Bueno, apresentada na Comissão de Finanças e Tributação – CFT ao Projeto de Lei - PL nº 6.052, de 2013.