EMI in modern AC motor drive systems


Autoria(s): Zare, Firuz
Data(s)

2009

Resumo

In this paper, several aspects of high frequency related issues of modern AC motor drive systems, such as common mode voltage, shaft voltage and resultant bearing current and leakage currents, have been discussed. Conducted emission is a major problem in modern motor drives that produce undesirable effects on electronic devices. In modern power electronic systems, increasing power density and decreasing cost and size of system are market requirements. Switching losses, harmonics and EMI are the key factors which should be considered at the beginning stage of a design to optimise a drive system.

Formato

application/pdf

Identificador

http://eprints.qut.edu.au/31174/

Publicador

IEEE EMC Society

Relação

http://eprints.qut.edu.au/31174/1/a31174.pdf

http://www.emcs.org/acstrial/newsletters/summer09/index.html

Zare, Firuz (2009) EMI in modern AC motor drive systems. IEEE EMC Society Newsletters, summer(222), pp. 53-58.

Direitos

Copyright 2009 IEEE

Personal use of this material is permitted. However, permission to reprint/republish this material for advertising or promotional purposes or for creating new collective works for resale or redistribution to servers or lists, or to reuse any copyrighted component of this work in other works must be obtained from the IEEE.

Fonte

Faculty of Built Environment and Engineering; School of Engineering Systems

Palavras-Chave #090600 ELECTRICAL AND ELECTRONIC ENGINEERING #shaft voltage #common mode voltage #inverter #pulse width modulation #EMI
Tipo

Journal Article