949 resultados para Dog - intraocular pressure
Resumo:
Changes to the redox status of biological systems have been implicated in the pathogenesis of a wide variety of disorders including cancer, Ischemia-reperfusion (I/R) injury and neurodegeneration. In times of metabolic stress e.g. ischaemia/reperfusion, reactive oxygen species (ROS) production overwhelms the intrinsic antioxidant capacity of the cell, damaging vital cellular components. The ability to quantify ROS changes in vivo, is therefore essential to understanding their biological role. Here we evaluate the suitability of a novel reversible profluorescent probe containing a redox-sensitive nitroxide moiety (methyl ester tetraethylrhodamine nitroxide, ME-TRN), as an in vivo, real-time reporter of retinal oxidative status. The reversible nature of the probe's response offers the unique advantage of being able to monitor redox changes in both oxidizing and reducing directions in real time. After intravitreal administration of the ME-TRN probe, we induced ROS production in rat retina using an established model of complete, acute retinal ischaemia followed by reperfusion. After restoration of blood flow, retinas were imaged using a Micron III rodent fundus fluorescence imaging system, to quantify the redox-response of the probe. Fluorescent intensity declined during the first 60 min of reperfusion. The ROS-induced change in probe fluorescence was ameliorated with the retinal antioxidant, lutein. Fluorescence intensity in non-Ischemia eyes did not change significantly. This new probe and imaging technology provide a reversible and real-time response to oxidative changes and may allow the in vivo testing of antioxidant therapies of potential benefit to a range of diseases linked to oxidative stress
Resumo:
To discover quantitative trait loci for intraocular pressure, amajor risk factor for glaucoma and the only modifiable one,weperformed agenome-wide association studyonadiscoverycohort of2175individualsfromSydney, Australia. We found a novel association between intraocular pressure and a common variant at 7p21 near to GLCCI1 and ICA1. The findings in this region were confirmed through two UK replication cohorts totalling 4866 individuals (rs59072263, Pcombined = 1.10 × 10-8). A copy of the G allele at this SNP is associated with an increase in mean IOP of 0.45 mmHg (95%CI = 0.30-0.61 mmHg). These results lend support to the implication of vesicle trafficking and glucocorticoid inducibility pathways in the determination of intraocular pressure and in the pathogenesis of primary open-angle glaucoma.
Resumo:
Purpose To investigate if the accuracy of intraocular pressure (IOP) measurements using rebound tonometry over disposable hydrogel (etafilcon A) contact lenses (CL) is affected by the positive power of the CLs. Methods The experimental group comprised 26 subjects, (8 male, 18 female). IOP measurements were undertaken on the subjects’ right eyes in random order using a Rebound Tonometer (ICare). The CLs had powers of +2.00D and +6.00D. Measurements were taken over each contact lens and also before and after the CLs had been worn. Results The IOP measure obtained with both CLs was significantly lower compared to the value without CLs (t test; p<0.001) but no significant difference was found between the two powers of CLs. Conclusions Rebound tonometry over positive hydrogel CLs leads to a certain degree of IOP underestimation. This result didn’t change for the two positive lenses used in the experiment, despite their large difference in power and therefore in lens thickness. Optometrists should bear this in mind when measuring IOP with the rebound tonometer over plus power contact lenses.
Resumo:
Glaucoma is a multifactorial long-term ocular neuropathy associated with progressive loss of the visual field, retinal nerve fiber structural abnormalities and optic disc changes. Like arterial hypertension it is usually a symptomless disease, but if left untreated leads to visual disability and eventual blindness. All therapies currently used aim to lower intraocular pressure (IOP) in order to minimize cell death. Drugs with new mechanisms of action could protect glaucomatous eyes against blindness. Renin-angiotensin system (RAS) is known to regulate systemic blood pressure and compounds acting on it are in wide clinical use in the treatment of hypertension and heart failure but not yet in ophthalmological use. There are only few previous studies concerning intraocular RAS, though evidence is accumulating that drugs antagonizing RAS can also lower IOP, the only treatable risk factor in glaucoma. The main aim of this experimental study was to clarify the expression of the renin-angiotensin system in the eye tissues and to test its potential oculohypotensive effects and mechanisms. In addition, the possible relationship between the development of hypertension and IOP was evaluated in animal models. In conclusion, a novel angiotensin receptor type (Mas), as well as ACE2 enzyme- producing agonists for Mas, were described for the first time in the eye structures participating in the regulation of IOP. In addition, a Mas receptor agonist significantly reduced even normal IOP. The effect was abolished by a specific receptor antagonist. Intraocular, local RAS would thus to be involved in the regulation of IOP, probably even more in pathological conditions such as glaucoma though there was no unambiguous relationship between arterial and ocular hypertension. The findings suggest the potential as antiglaucomatous drugs of agents which increase ACE2 activity and the formation of angiotensin (1-7), or activate Mas receptors.
Resumo:
Objective: The influence of sex hormones on intraocular pressure (IOP) has been the focus of recent debate. Previous studies investigating the effects of hormone therapy (HT) on IOP in postmenopausal women have produced conflicting results but have been limited by small numbers of participants. The aim of our study was to compare IOP in women without glaucoma taking HT with those not taking HT. Methods: A prospective cross-sectional study of postmenopausal women visiting a single ophthalmic medical practitioner was conducted. All women with a history of intraocular disease, a family history of glaucoma, or refractive error exceeding ±5 diopters were excluded. Applanation tonometry was used to measure IOP, and participants were then asked if they were current HT users. Results: A total of 263 participants were recruited, of whom 91 reported current use of HT; 172 had never used HT. Within the HT group, 33 were taking an estrogen-therapy and 58 were taking a estrogen-progesterone therapy. Mean IOP in the HT group was significantly lower than that in the non-HT group; the mean difference was 1.41 mm Hg (P <0.001). This difference remained statistically significant after statistical correction for age, use of systemic ß-blockers, and time of IOP measurement. There was no significant difference in mean IOP between women taking combined versus those taking estrogen-only preparations. Conclusions: Our study showed that IOP was significantly lower in women taking HT than in those who had never taken HT, even after removing other possible influences on IOP. The IOP-lowering effect of HT deserves further investigation to explore whether it may represent a possible new therapeutic modality for glaucoma. © 2010 by The North American Menopause Society.
Resumo:
Aims. To evaluate the effect of acute elevation of intraocular pressure (IOP) on optic disc cupping. Methods. 10 emmetropic and 10 myopic volunteers were included in this study. The cup area (CA) and cup volume (CV) of the optic disc were determined with the Heidelberg retina tomograph (HRT). After baseline determinations, a suction cup was used to increase the intraocular pressure (IOP) to 20-25 mmHg above the baseline and HRT images were obtained. Results. Baseline IOP was 13.5 (SD 1.3) mmHg and 12.6 (2.6) mmHg in the emmetropic and myopic groups, respectively. The IOP was elevated to 35.4 (3.3) mmHg and 34.4 (2.5) mmHg in the emmetropic and myopic groups, respectively. When compared with their baseline values, the cupping variables (CA and CV) were significantly increased (p <0.05) during the suction treatment in both emmetropic and myopic subjects. Conclusion. There was a significant enlargement in the optic disc cupping during the artificial increment of intraocular pressure in both emmetropic and myopic eyes. In non-glaucomatous eyes the optic nerve head has a partially dynamic topography dependent upon the level of IOP.
Resumo:
Aims. To evaluate the intraocular pressure (IOP) measurements in patients with band keratopathy or glued corneas obtained from affected and non-affected areas. Methods. 15 patients with band keratopathy or glued corneas were prospectively recruited. When both eyes were affected, only the right eye was analysed. Tono-Pen readings of IOP were obtained sequentially from the affected and non-affected corneal surface. Additionally, Goldmann applanation tonometry was attempted. Results. Determination of IOP with the Tono-Pen was possible in all cases, while Goldmann tonometry was not performed in three patients because of severe corneal irregularities. The average of the Tono-Pen readings obtained from the affected cornea (34.8 (SD 14.0) mmHg) was consistently and significantly higher (p <0.001) than mean IOP obtained by the Tono-Pen from the non-affected area (14.8 (4.3) mmHg). The average of Goldmann tonometry readings (14.4 (6.1) mmHg) did not differ significantly from the Tono-Pen values obtained from the non-affected corneal area (p = 0.47) but was significantly lower than the Tono-Pen measurements obtained from the affected area (p <0.001) Conclusion. In patients with band keratopathy or glued corneas determination of IOP by Tono-Pen tonometry varies from affected to non-affected area. The Tono-Pen overestimates the level of IOP when it is applied to areas with band keratopathy or with glue.
Resumo:
PURPOSE: The purpose of this study was to assess the effect on intraocular pressure (IOP) and the safety and tolerability of oromucosal administration of a low dose of delta-9-tetrahydrocannabinol (?-9-THC) and cannabidiol (CBD). PATIENTS AND METHODS: A randomized, double-masked, placebo-controlled, 4 way crossover study was conducted at a single center, using cannabis-based medicinal extract of ?-9-THC and CBD. Six patients with ocular hypertension or early primary open angle glaucoma received a single sublingual dose at 8 AM of 5 mg ?-9-THC, 20 mg CBD, 40 mg CBD, or placebo. Main outcome measure was IOP. Secondary outcomes included visual acuity, vital signs, and psychotropic effects. RESULTS: Two hours after sublingual administration of 5 mg ?-9-THC, the IOP was significantly lower than after placebo (23.5 mm Hg vs. 27.3 mm Hg, P=0.026). The IOP returned to baseline level after the 4-hour IOP measurement. CBD administration did not reduce the IOP at any time. However, the higher dose of CBD (40 mg) produced a transient elevation of IOP at 4 hours after administration, from 23.2 to 25.9 mm Hg (P=0.028). Vital signs and visual acuity were not significantly changed. One patient experienced a transient and mild paniclike reaction after ?-9-THC administration. CONCLUSIONS: A single 5 mg sublingual dose of ?-9-THC reduced the IOP temporarily and was well tolerated by most patients. Sublingual administration of 20 mg CBD did not reduce IOP, whereas 40 mg CBD produced a transient increase IOP rise. Copyright © 2006 by Lippincott Williams & Wilkins.
Resumo:
Aim: To study the long-term outcome of deep sclerectomy in patients with open angle glaucoma. Methods: Prospective consecutive series of 43 eyes (38 patients) with medically uncontrolled open-angle glaucoma undergoing deep sclerectomy. All patients underwent clinical assessment before and after surgery at day 7 and at months 1, 3, 6, 12, 18, 24, 36. Surgical success was considered if the patient's intraocular pressure (IOP)>22 mmHg and the IOP was lowered by more than 20% without the use of any medication. Kaplan-Meier survival curves were used to evaluate the success rate. Results: The mean follow-up time was 28.1±8.2 months. Mean IOP decreased significantly from a preoperative value of 24.6±5.5 mmHg to a postoperative value of 18.5±4.6 mmHg at 36 months (P>0.001). Microperforation of TDM occurred in three cases (7.0%) and ciliary body prolapse in one case (2.3%) but did not prevent completion of the operation. Postoperatively, hyphaema was detected in one case and shallow anterior chamber in another case and both were treated conservatively. Bleb encapsulation with elevation of IOP occurred in two cases (4.7%) and was treated with 5-fluorouracil subconjunctival injection. Goniopuncture with neodymium : YAG laser was performed in two cases (4.7%). There were no other late complications with the exception of failure of the operation. On the life-table analysis the success rate at 12, 24, and 30 months were 61.4, 36.6, and 18.9%, respectively. Conclusion: Deep sclerectomy reduced the IOP temporarily while minimising the risk of postoperative complications commonly encountered with standard trabeculectomy. However, after long-term follow-up surgery failed to maintain a low IOP. © 2006 Nature Publishing Group. All rights reserved.
Resumo:
PURPOSE: To consider whether STZ-induced hyperglycemia renders rat retinal function and ocular blood flow more susceptible to acute intraocular pressure (IOP) challenge.
METHODS: Retinal function (electroretinogram, ERG) was measured during acute IOP challenge (10-100 mmHg, 5 mmHg increments, 3 min/step, vitreal cannulation) in adult Long-Evans rats (6-week old, citrate: n=6, STZ: n=10) 4 weeks after citrate buffer or streptozotocin (STZ, 65 mg/kg, blood glucose > 15 mmol/l) injection. At each IOP, dim and bright flash (-4.56, -1.72 log cd.s.m^-2) ERG responses were recorded to measure inner retinal and ON-bipolar cell function, respectively. Ocular blood flow (laser Doppler flowmetry, citrate; n=6, STZ; n=10) was also measured during acute IOP challenge. Retinae were isolated for qPCR analysis of nitric oxide synthase mRNA expression endothelial, eNos; inducible, iNos; neuronal, nNos).
RESULTS: STZ-induced diabetes increased the susceptibility of inner retinal (IOP at 50% response, 60.1, CI: 57.0-62.0 mmHg vs. citrate: 67.5, CI: 62.1-72.4 mmHg) and ON-bipolar cell function (STZ: 60.3, CI: 58.0-62.8 mmHg vs. citrate: 65.1, CI: 58.0-62.78 mmHg) and ocular blood flow (43.9, CI: 40.8-46.8 vs. citrate: 53.4, CI: 50.7-56.1 mmHg) to IOP challenge. Citrate eyes showed elevated eNos mRNA (+49.7%) after IOP stress, an effect not found in STZ-diabetic eyes (-5.7%, P<0.03). No difference was observed for iNos or nNos (P>0.05) following IOP elevation.
CONCLUSIONS: STZ-induced diabetes increased functional susceptibility during acute IOP challenge. This functional vulnerability is associated with a reduced capacity for diabetic eyes to upregulate eNOS expression and to autoregulate blood flow in response to stress.