938 resultados para Closed-Loop Systems
Resumo:
The research field of my PhD concerns mathematical modeling and numerical simulation, applied to the cardiac electrophysiology analysis at a single cell level. This is possible thanks to the development of mathematical descriptions of single cellular components, ionic channels, pumps, exchangers and subcellular compartments. Due to the difficulties of vivo experiments on human cells, most of the measurements are acquired in vitro using animal models (e.g. guinea pig, dog, rabbit). Moreover, to study the cardiac action potential and all its features, it is necessary to acquire more specific knowledge about single ionic currents that contribute to the cardiac activity. Electrophysiological models of the heart have become very accurate in recent years giving rise to extremely complicated systems of differential equations. Although describing the behavior of cardiac cells quite well, the models are computationally demanding for numerical simulations and are very difficult to analyze from a mathematical (dynamical-systems) viewpoint. Simplified mathematical models that capture the underlying dynamics to a certain extent are therefore frequently used. The results presented in this thesis have confirmed that a close integration of computational modeling and experimental recordings in real myocytes, as performed by dynamic clamp, is a useful tool in enhancing our understanding of various components of normal cardiac electrophysiology, but also arrhythmogenic mechanisms in a pathological condition, especially when fully integrated with experimental data.
Resumo:
We present a new model formulation for a multi-product lot-sizing problem with product returns and remanufacturing subject to a capacity constraint. The given external demand of the products has to be satisfied by remanufactured or newly produced goods. The objective is to determine a feasible production plan, which minimizes production, holding, and setup costs. As the LP relaxation of a model formulation based on the well-known CLSP leads to very poor lower bounds, we propose a column-generation approach to determine tighter bounds. The lower bound obtained by column generation can be easily transferred into a feasible solution by a truncated branch-and-bound approach using CPLEX. The results of an extensive numerical study show the high solution quality of the proposed solution approach.
Resumo:
Durante las últimas décadas se ha producido un fenómeno global de envejecimiento en la población. Esta tendencia se puede observar prácticamente en todos los países del mundo y se debe principalmente a los avances en la medicina, y a los descensos en las tasas de fertilidad y mortalidad. El envejecimiento de la población tiene un gran impacto en la salud de los ciudadanos, y a menudo es la causa de aparición de enfermedades crónicas. Este tipo de enfermedades supone una amenaza y una carga importantes para la sociedad, especialmente en aspectos como la mortalidad o los gastos en los sistemas sanitarios. Entre las enfermedades cardiovasculares, la insuficiencia cardíaca es probablemente la condición con mayor prevalencia y afecta a 23-26 millones de personas en todo el mundo. Normalmente, la insuficiencia cardíaca presenta un mal pronóstico y una tasa de supervivencia bajas, en algunos casos peores que algún tipo de cáncer. Además, suele ser la causa de hospitalizaciones frecuentes y es una de las enfermedades más costosas para los sistemas sanitarios. La tendencia al envejecimiento de la población y la creciente incidencia de las enfermedades crónicas están llevando a una situación en la que los sistemas de salud no son capaces de hacer frente a la demanda de la sociedad. Los servicios de salud existentes tendrán que adaptarse para ser efectivos y sostenibles en el futuro. Es necesario identificar nuevos paradigmas de cuidado de pacientes, así como mecanismos para la provisión de servicios que ayuden a transformar estos sistemas sanitarios. En este contexto, esta tesis se plantea la búsqueda de soluciones, basadas en las Tecnologías de la Información y la Comunicación (TIC), que contribuyan a realizar la transformación en los sistemas sanitarios. En concreto, la tesis se centra en abordar los problemas de una de las enfermedades con mayor impacto en estos sistemas: la insuficiencia cardíaca. Las siguientes hipótesis constituyen la base para la realización de este trabajo de investigación: 1. Es posible definir un modelo basado en el paradigma de lazo cerrado y herramientas TIC que formalice el diseño de mejores servicios para pacientes con insuficiencia cardíaca. 2. El modelo de lazo cerrado definido se puede utilizar para definir un servicio real que ayude a gestionar la insuficiencia cardíaca crónica. 3. La introducción, la adopción y el uso de un servicio basado en el modelo definido se traducirá en mejoras en el estado de salud de los pacientes que sufren insuficiencia cardíaca. a. La utilización de un sistema basado en el modelo de lazo cerrado definido mejorará la experiencia del usuario de los pacientes. La definición del modelo planteado se ha basado en el estándar ISO / EN 13940- Sistema de conceptos para dar soporte a la continuidad de la asistencia. Comprende un conjunto de conceptos, procesos, flujos de trabajo, y servicios como componentes principales, y representa una formalización de los servicios para los pacientes con insuficiencia cardíaca. Para evaluar el modelo definido se ha definido un servicio real basado en el mismo, además de la implementación de un sistema de apoyo a dicho servicio. El diseño e implementación de dicho sistema se realizó siguiendo la metodología de Diseño Orientado a Objetivos. El objetivo de la evaluación consistía en investigar el efecto que tiene un servicio basado en el modelo de lazo cerrado sobre el estado de salud de los pacientes con insuficiencia cardíaca. La evaluación se realizó en el marco de un estudio clínico observacional. El análisis de los resultados ha comprendido métodos de análisis cuantitativos y cualitativos. El análisis cuantitativo se ha centrado en determinar el estado de salud de los pacientes en base a datos objetivos (obtenidos en pruebas de laboratorio o exámenes médicos). Para realizar este análisis se definieron dos índices específicos: el índice de estabilidad y el índice de la evolución del estado de salud. El análisis cualitativo ha evaluado la autopercepción del estado de salud de los pacientes en términos de calidad de vida, auto-cuidado, el conocimiento, la ansiedad y la depresión, así como niveles de conocimiento. Se ha basado en los datos recogidos mediante varios cuestionarios o instrumentos estándar (i.e. EQ-5D, la Escala de Ansiedad y Depresión (HADS), el Cuestionario de Cardiomiopatía de Kansas City (KCCQ), la Escala Holandesa de Conocimiento de Insuficiencia Cardíaca (DHFKS), y la Escala Europea de Autocuidado en Insuficiencia Cardíaca (EHFScBS), así como cuestionarios dedicados no estandarizados de experiencia de usuario. Los resultados obtenidos en ambos análisis, cuantitativo y cualitativo, se compararon con el fin de evaluar la correlación entre el estado de salud objetivo y subjetivo de los pacientes. Los resultados de la validación demostraron que el modelo propuesto tiene efectos positivos en el cuidado de los pacientes con insuficiencia cardíaca y contribuye a mejorar su estado de salud. Asimismo, ratificaron al modelo como instrumento válido para la definición de servicios mejorados para la gestión de esta enfermedad. ABSTRACT During the last decades we have witnessed a global aging phenomenon in the population. This can be observed in practically every country in the world, and it is mainly caused by the advances in medicine, and the decrease of mortality and fertility rates. Population aging has an important impact on citizens’ health and it is often the cause for chronic diseases, which constitute global burden and threat to the society in terms of mortality and healthcare expenditure. Among chronic diseases, Chronic Heart Failure (CHF) or Heart Failure (HF) is probably the one with highest prevalence, affecting between 23 and 26 million people worldwide. Heart failure is a chronic, long-term and serious condition with very poor prognosis and worse survival rates than some type of cancers. Additionally, it is often the cause of frequent hospitalizations and one of the most expensive conditions for the healthcare systems. The aging trends in the population and the increasing incidence of chronic diseases are leading to a situation where healthcare systems are not able to cope with the society demand. Current healthcare services will have to be adapted and redefined in order to be effective and sustainable in the future. There is a need to find new paradigms for patients’ care, and to identify new mechanisms for services’ provision that help to transform the healthcare systems. In this context, this thesis aims to explore new solutions, based on ICT, that contribute to achieve the needed transformation within the healthcare systems. In particular, it focuses on addressing the problems of one of the diseases with higher impact within these systems: Heart Failure. The following hypotheses represent the basis to the elaboration of this research: 1. It is possible to define a model based on a closed-loop paradigm and ICT tools that formalises the design of enhanced healthcare services for chronic heart failure patients. 2. The described closed-loop model can be exemplified in a real service that supports the management of chronic heart failure disease. 3. The introduction, adoption and use of a service based on the outlined model will result in improvements in the health status of patients suffering heart failure. 4. The user experience of patients when utilizing a system based on the defined closed-loop model will be enhanced. The definition of the closed-loop model for health care support of heart failure patients have been based on the standard ISO/EN 13940 System of concepts to support continuity of care. It includes a set of concept, processes and workflows, and services as main components, and it represent a formalization of services for heart failure patients. In order to be validated, the proposed closed-loop model has been instantiated into a real service and a supporting IT system. The design and implementation of the system followed the user centred design methodology Goal Oriented Design. The validation, that included an observational clinical study, aimed to investigate the effect that a service based on the closed-loop model had on heart failure patients’ health status. The analysis of results comprised quantitative and qualitative analysis methods. The quantitative analysis was focused on determining the health status of patients based on objective data (obtained in lab tests or physical examinations). Two specific indexes where defined and considered in this analysis: the stability index and the health status evolution index. The qualitative analysis assessed the self-perception of patients’ health status in terms of quality of life, self-care, knowledge, anxiety and depression, as well as knowledge levels. It was based on the data gathered through several standard instruments (i.e. EQ-5D, the Hospital Anxiety and Depression Scale, the Kansas City Cardiomyopathy Questionnaire, the Dutch Heart Failure Knowledge Scale, and the European Heart Failure Self-care Behaviour Scale) as well as dedicated non-standardized user experience questionnaires. The results obtained in both analyses, quantitative and qualitative, were compared in order to assess the correlation between the objective and subjective health status of patients. The results of the validation showed that the proposed model contributed to improve the health status of the patients and had a positive effect on the patients’ care. It also proved that the model is a valid instrument for designing enhanced healthcare services for heart failure patients.
Resumo:
Deep brain stimulation (DBS) provides significant therapeutic benefit for movement disorders such as Parkinson’s disease (PD). Current DBS devices lack real-time feedback (thus are open loop) and stimulation parameters are adjusted during scheduled visits with a clinician. A closed-loop DBS system may reduce power consumption and side effects by adjusting stimulation parameters based on patient’s behavior. Thus behavior detection is a major step in designing such systems. Various physiological signals can be used to recognize the behaviors. Subthalamic Nucleus (STN) Local field Potential (LFP) is a great candidate signal for the neural feedback, because it can be recorded from the stimulation lead and does not require additional sensors. This thesis proposes novel detection and classification techniques for behavior recognition based on deep brain LFP. Behavior detection from such signals is the vital step in developing the next generation of closed-loop DBS devices. LFP recordings from 13 subjects are utilized in this study to design and evaluate our method. Recordings were performed during the surgery and the subjects were asked to perform various behavioral tasks. Various techniques are used understand how the behaviors modulate the STN. One method studies the time-frequency patterns in the STN LFP during the tasks. Another method measures the temporal inter-hemispheric connectivity of the STN as well as the connectivity between STN and Pre-frontal Cortex (PFC). Experimental results demonstrate that different behaviors create different m odulation patterns in STN and it’s connectivity. We use these patterns as features to classify behaviors. A method for single trial recognition of the patient’s current task is proposed. This method uses wavelet coefficients as features and support vector machine (SVM) as the classifier for recognition of a selection of behaviors: speech, motor, and random. The proposed method is 82.4% accurate for the binary classification and 73.2% for classifying three tasks. As the next step, a practical behavior detection method which asynchronously detects behaviors is proposed. This method does not use any priori knowledge of behavior onsets and is capable of asynchronously detect the finger movements of PD patients. Our study indicates that there is a motor-modulated inter-hemispheric connectivity between LFP signals recorded bilaterally from STN. We utilize a non-linear regression method to measure this inter-hemispheric connectivity and to detect the finger movements. Our experimental results using STN LFP recorded from eight patients with PD demonstrate this is a promising approach for behavior detection and developing novel closed-loop DBS systems.
Resumo:
National Highway Traffic Safety Administration, Office of Research and Development, Washington, D.C.
Resumo:
This paper reports on the development of elements of an e-supply chain management system for managing maintenance, repair and overhaul (MRO) relationships in the aerospace industry. A standard systems development methodology has been followed to produce a process model (i.e. the AMSCR model); an information model (i.e. business rules) and a computerised information management capability (i.e. automated optimisation). The proof of concept for this web-based MRO supply chain system has been established through the collaboration with a sample of the different types of supply chain members. The proven benefit is a reduction in the stock-holding costs for the whole supply chain whilst also minimising non-flying time of the aircraft that the supply chain supports. This type of system is now vital in an industry that has continuously decreasing profit margins, which in turn means pressure to reduce servicing times and increase the interval between maintenance actions.
Resumo:
Dissertação para obtenção do Grau de Mestre em Engenharia Química e Bioquímica
Resumo:
Type 1 diabetic patients depend on external insulin delivery to keep their blood glucose within near-normal ranges. In this work, two robust closed-loop controllers for blood glucose regulation are developed to prevent the life-threatening hypoglycemia, as well as to avoid extended hyperglycemia. The proposed controllers are designed by using the sliding mode control technique in a Smith predictor structure. To improve meal disturbance rejection, a simple feedforward controller is added to inject meal-time insulin bolus. Simulations scenarios were used to test the controllers, and showed the controllers ability to maintain the glucose levels within the safe limits in the presence of errors in measurements, modeling and meal estimation
Resumo:
The effect of motor training using closed loop controlled Functional Electrical Stimulation (FES) on motor performance was studied in 5 spinal cord injured (SCI) volunteers. The subjects trained 2 to 3 times a week during 2 months on a newly developed rehabilitation robot (MotionMaker?). The FES induced muscle force could be adequately adjusted throughout the programmed exercises by the way of a closed loop control of the stimulation currents. The software of the MotionMaker? allowed spasms to be detected accurately and managed in a way to prevent any harm to the SCI persons. Subjects with incomplete SCI reported an increased proprioceptive awareness for motion and were able to achieve a better voluntary activation of their leg muscles during controlled FES. At the end of the training, the voluntary force of the 4 incomplete SCI patients was found increased by 388% on their most affected leg and by 193% on the other leg. Active mobilisation with controlled FES seems to be effective in improving motor function in SCI persons by increasing the sensory input to neuronal circuits involved in motor control as well as by increasing muscle strength.
Resumo:
This paper presents a Bayesian approach to the design of transmit prefiltering matrices in closed-loop schemes robust to channel estimation errors. The algorithms are derived for a multiple-input multiple-output (MIMO) orthogonal frequency division multiplexing (OFDM) system. Two different optimizationcriteria are analyzed: the minimization of the mean square error and the minimization of the bit error rate. In both cases, the transmitter design is based on the singular value decomposition (SVD) of the conditional mean of the channel response, given the channel estimate. The performance of the proposed algorithms is analyzed,and their relationship with existing algorithms is indicated. As withother previously proposed solutions, the minimum bit error rate algorithmconverges to the open-loop transmission scheme for very poor CSI estimates.
Resumo:
This report explores the design and control issues associated with a brushless actuator capable of achieving extremely high torque accuracy. Models of several different motor - sensor configurations were studied to determine dynamic characteristics. A reaction torque sensor fixed to the motor stator was implemented to decouple the transmission dynamics from the sensor. This resulted in a compact actuator with higher bandwidth and precision than could be obtained with an inline or joint sensor. Testing demonstrated that closed-loop torque accuracy was within 0.1%, and the mechanical bandwidth approached 300 Hz.
Resumo:
Objectives: To assess the impact of a closed-loop electronic prescribing, automated dispensing, barcode patient identification and electronic medication administration record (EMAR) system on prescribing and administration errors, confirmation of patient identity before administration, and staff time. Design, setting and participants: Before-and-after study in a surgical ward of a teaching hospital, involving patients and staff of that ward. Intervention: Closed-loop electronic prescribing, automated dispensing, barcode patient identification and EMAR system. Main outcome measures: Percentage of new medication orders with a prescribing error, percentage of doses with medication administration errors (MAEs) and percentage given without checking patient identity. Time spent prescribing and providing a ward pharmacy service. Nursing time on medication tasks. Results: Prescribing errors were identified in 3.8% of 2450 medication orders pre-intervention and 2.0% of 2353 orders afterwards (p<0.001; χ2 test). MAEs occurred in 7.0% of 1473 non-intravenous doses pre-intervention and 4.3% of 1139 afterwards (p = 0.005; χ2 test). Patient identity was not checked for 82.6% of 1344 doses pre-intervention and 18.9% of 1291 afterwards (p<0.001; χ2 test). Medical staff required 15 s to prescribe a regular inpatient drug pre-intervention and 39 s afterwards (p = 0.03; t test). Time spent providing a ward pharmacy service increased from 68 min to 98 min each weekday (p = 0.001; t test); 22% of drug charts were unavailable pre-intervention. Time per drug administration round decreased from 50 min to 40 min (p = 0.006; t test); nursing time on medication tasks outside of drug rounds increased from 21.1% to 28.7% (p = 0.006; χ2 test). Conclusions: A closed-loop electronic prescribing, dispensing and barcode patient identification system reduced prescribing errors and MAEs, and increased confirmation of patient identity before administration. Time spent on medication-related tasks increased.
Resumo:
Acquiring a mechanistic understanding of the role of the biotic feedbacks on the links between atmospheric CO2 concentrations and temperature is essential for trustworthy climate predictions. Currently, computer based simulations are the only available tool to estimate the global impact of the biotic feedbacks on future atmospheric CO2 and temperatures. Here we propose an alternative and complementary approaches by using materially closed and energetically open analogue/physical models of the carbon cycle. We argue that there is potential in using a materially closed approach to improve our understanding of the magnitude and sign of many biotic feedbacks, and that recent technological advance make this feasible. We also suggest how such systems could be designed and discuss the advantages and limitations of establishing physical models of the global carbon cycle.
Resumo:
The feedback mechanism used in a brain-computer interface (BCI) forms an integral part of the closed-loop learning process required for successful operation of a BCI. However, ultimate success of the BCI may be dependent upon the modality of the feedback used. This study explores the use of music tempo as a feedback mechanism in BCI and compares it to the more commonly used visual feedback mechanism. Three different feedback modalities are compared for a kinaesthetic motor imagery BCI: visual, auditory via music tempo, and a combined visual and auditory feedback modality. Visual feedback is provided via the position, on the y-axis, of a moving ball. In the music feedback condition, the tempo of a piece of continuously generated music is dynamically adjusted via a novel music-generation method. All the feedback mechanisms allowed users to learn to control the BCI. However, users were not able to maintain as stable control with the music tempo feedback condition as they could in the visual feedback and combined conditions. Additionally, the combined condition exhibited significantly less inter-user variability, suggesting that multi-modal feedback may lead to more robust results. Finally, common spatial patterns are used to identify participant-specific spatial filters for each of the feedback modalities. The mean optimal spatial filter obtained for the music feedback condition is observed to be more diffuse and weaker than the mean spatial filters obtained for the visual and combined feedback conditions.