926 resultados para CATHETER-RELATED INFECTIONS


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Background Bloodstream infections resulting from intravascular catheters (catheter-BSI) in critical care increase patients' length of stay, morbidity and mortality, and the management of these infections and their complications has been estimated to cost the NHS annually £19.1–36.2M. Catheter-BSI are thought to be largely preventable using educational interventions, but guidance as to which types of intervention might be most clinically effective is lacking. Objective To assess the effectiveness and cost-effectiveness of educational interventions for preventing catheter-BSI in critical care units in England. Data sources Sixteen electronic bibliographic databases – including MEDLINE, MEDLINE In-Process & Other Non-Indexed Citations, Cumulative Index to Nursing and Allied Health Literature (CINAHL), NHS Economic Evaluation Database (NHS EED), EMBASE and The Cochrane Library databases – were searched from database inception to February 2011, with searches updated in March 2012. Bibliographies of systematic reviews and related papers were screened and experts contacted to identify any additional references. Review methods References were screened independently by two reviewers using a priori selection criteria. A descriptive map was created to summarise the characteristics of relevant studies. Further selection criteria developed in consultation with the project Advisory Group were used to prioritise a subset of studies relevant to NHS practice and policy for systematic review. A decision-analytic economic model was developed to investigate the cost-effectiveness of educational interventions for preventing catheter-BSI. Results Seventy-four studies were included in the descriptive map, of which 24 were prioritised for systematic review. Studies have predominantly been conducted in the USA, using single-cohort before-and-after study designs. Diverse types of educational intervention appear effective at reducing the incidence density of catheter-BSI (risk ratios statistically significantly < 1.0), but single lectures were not effective. The economic model showed that implementing an educational intervention in critical care units in England would be cost-effective and potentially cost-saving, with incremental cost-effectiveness ratios under worst-case sensitivity analyses of < £5000/quality-adjusted life-year. Limitations Low-quality primary studies cannot definitively prove that the planned interventions were responsible for observed changes in catheter-BSI incidence. Poor reporting gave unclear estimates of risk of bias. Some model parameters were sourced from other locations owing to a lack of UK data. Conclusions Our results suggest that it would be cost-effective and may be cost-saving for the NHS to implement educational interventions in critical care units. However, more robust primary studies are needed to exclude the possible influence of secular trends on observed reductions in catheter-BSI.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Objective: To determine the number of colony-forming units (CFU) that best correlates with catheter-related infections (CRI) in newborns.Methods: This was a prospective study of semiquantitative cultures of catheter tips obtained from newborns in the neonatal unit at Faculdade de Medicina de Botucatu, state of São Paulo, Brazil. The microorganisms isolated from catheter and peripheral blood cultures were identified and submitted to a drug susceptibility test. The optimal cutoff point was determined by the receiver operating characteristic (ROC) curve.Results: A total of 85 catheters obtained from 63 newborns were studied. Staphylococcus epidermidis was the predominant species in the catheters (75%). Eight of 11 (72.7%) CRI episodes were associated with coagulase-negative staphylococci, six of which were of the S. epidermidis type. ROC curve analysis indicated that the optimal cutoff point for the diagnosis of CRI was 122 CFU.Conclusions: The cutoff point of 122 CFU correlated best with the diagnosis of CRI in newborns.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Semiquantitative (Maki) and quantitative (Brun- Buisson) culture techniques were employed in the diagnosis of catheter-related bloodstream infections (CRBSI) in patients who have a short-term central venous catheter (inserted for 30 days). The diagnosis of CRBSI was based on the results of semiquantitative and quantitative culture of material from the removed catheters. Catheter tips (118) from 100 patients were evaluated by both methods. Semiquantitative analysis revealed 34 catheters (28.8%) colonized by ≥15 colonyforming units (cfu), while quantitative cultures (34 catheters, 28.8%) showed the growth of ≥103 cfu/mL. Bacteremia was confirmed in four patients by isolating microorganisms of identical species from both catheters and blood samples. Using the semiquantitative culture technique on short-term central venous catheter tips, we have shown that with a cut-off level of ≥15 cfu, the technique had 100.0% sensitivity, specificity of 68.4%, 25.0% positive predictive value (PPV) and 100.0% negative predictive value (NPV), efficiency of 71.4% and a prevalence of 9.5%. The quantitative method, with a cut-off limit of ≥103 cfu/mL, gave identical values: the sensitivity was 100.0%, specificity 68.4%, positive predictive value (PPV) 25.0%, negative predictive value (NPV) 100.0%, efficiency 71.4% and prevalence 9.5%. We concluded that the semiquantitative and quantitative culture methods, evaluated in parallel, for the first time in Brazil, have similar sensitivity and specificity. Keywords: central venous catheter; semi-quantitative culture; quantitative culture; catheter-related bacteremia.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

There are many infectious complications related to vascular access in patients undergoing maintenance hemodialysis. We report two cases of endophthalmitis as a metastatic infection associated with a tunneled catheter and a temporary dual lumen catheter. Both patients were diabetic. A 61-year-old female on maintenance hemodialysis by a jugular tunnelized catheter during the past year was receiving parenteral antibiotics for catheter salvage due to fever episodes in the last 3 months. She was admitted to the hospital presenting pain, proptosis, conjunctival hyperemia, corneal infiltrate, and visual acuity of no light perception (NLP). A 51-year-old male recently undergoing hemodialysis by a temporary dual lumen catheter presented fever. His catheter was removed, but he was admitted to the hospital presenting fever, decreased vision, edema, and pain in his left eye. On examination, eyelid edema, conjunctival hyperemia, purulent secretion, hypopyon in the pupils, and visual acuity of NLP were verified. A diagnosis of endogenous endophthalmitis was made in both patients on clinical grounds and computed tomography. Evisceration of the left eye was the first option of treatment for both patients due to poor vision. Cultures of the eviscerated ocular globes showed Staphylococcus hemolyticus and Staphylococcus aureus, respectively. After evisceration, both patients received treatment, had a good outcome, and were discharged to continue their hemodialysis program. Metastatic bacterial endophthalmitis is a rare complication of dialysis catheter-related bacteremia. When suspected, urgent ophthalmologic evaluation and treatment are needed to reduce the risk of losing vision in the affected eye.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

An observational study was conducted in a SICU to determine the frequency of subclavian vein catheter-related infection at 72 hours, to identify the hospital cost of exchange via a guidewire and the estimated hospital cost-savings of a 72 hour vs 144 hour exchange policy.^ An overall catheter-related infection ($\geq$15 col. by Maki's technique (1977)) occurred in 3% (3/100) of the catheter tips cultured. Specific infections rates were: 9.7% (3/31) for triple lumen catheters, 0% (0/30) for Swan-Ganz catheters, 0% (0/30) for Cordes catheters, and 0% (0/9) for single lumen catheters.^ An estimated annual hospital cost-savings of $35,699.00 was identified if exchange of 72 hour policy were changed to every 144 hours.^ It was recommended that a randomized clinical trial be conducted to determine the effect of changing a subclavian vein catheter via a guidewire every 72 hours vs 144 hours. ^

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Background: Surveillance programmes have become the most effective tool for controlling catheter-related bloodstream infections (CRBSI). However, few studies have investigated programmes covering all hospital settings. Aim: To describe the results of a control and prevention programme for CRBSI based on compliance with recommendations for insertion and maintenance, using annual burden of disease in a tertiary level hospital. Methods: A CRBSI control and prevention programme involving all hospital settings was implemented. The programme consisted of CRBSI surveillance, direct observation of insertion and maintenance of catheters to determine performance, and education for healthcare workers. Findings: In total, 2043 short-term catheters were inserted in 1546 patients for 18,570 catheter-days, and 279 long-term catheters were inserted in 243 patients for 40,440 catheter-days. The annual incidence density was 5.98 (first semester 6.40, second semester 5.64) CRBSI per 1000 catheter-days for short-term catheters, and 0.57 (first semester 0.66, second semester 0.43) CRBSI per 1000 catheter-days for long-term catheters. One hundred and forty insertion procedures were observed, with an average insertion time of 13 (standard deviation 7) min. Compliance with recommendations was as follows: hand hygiene, 86.8%; use of alcoholic chlorhexidine solution for skin disinfection, 35.5%; use of mask, 93.4%; use of gloves, 98.7%; use of gown, 75.0%; use of sterile cloth, 93.8%; use of cap, 92.2%; bandage application, 62.7%; and use of aseptic technique, 89.5%. Forty-five maintenance procedures were observed, and compliance rates were as follows: hand hygiene, 42.1%; use of gloves, 78.1%; and port disinfection with alcoholic chlorhexidine solution, 32.5%. Conclusion: The CRBSI control and prevention programme implemented at the study hospital has decreased the rate of CRBSI, provided important information about the total burden of disease, and revealed possible ways to improve interventions in the future.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The present thesis investigates targeted (locally and systemically) delivery of a novel group of inhibitors of enzyme transglutaminases (TGs). TGs are a widely distributed group of enzymes that catalyse the formation of isopeptide bonds between the y-carboxamide group of protein-bound glutamines and the a-amino group of protein-bound lysines or polyamines. The first group of the novel inhibitors tested were the tluorescently labelled inhibitors of Factor XIIIa (FXIIIa). These small, non-toxic inhibitors have the potential to prevent stabilisation of thrombi by FXIIIa and consequently increase the natural rate of thrombolysis, in addition it reduces staphylococcal colonisation of catheters by inhibiting their FXIIIa¬mediated cross-linking to blood clot proteins on the central venous catheter (CVCs) surface. The aim of this work was to incorporate the FXIIIa inhibitor either within coating of polyurethane (PU) catheters or to integrate it into silicone catheters, so as to reduce the incidence of thrombotic occlusion and associated bacterial infection in CVCs. The initial work focused on the incorporation of FXIIIa inhibitors within polymeric coatings of PU catheters. After defining the key characteristics desired for an effective polymeric-coating, polyvinylpyrrolidone (PVP), poly(lactic-co-glycolic acid) (PLGA) or their combination were studies as polymers of choice for coating of the catheters_ The coating was conducted by dip-coating method in a polymer solution containing the inhibitor. Upon incubation of the inhibitor-and polymer-coated strips in buffer, PVP was dissolved instantly, generating fast and significant drug release, whilst PLGA did not dissolve, yielding a slow and an insufficient amount of drug release. Nevertheless, the drug release profile was enhanced upon employing a blend solution of PVP and PLGA. The second part of the study was to incorporate the FXIIIa inhibitor into a silicone elastomer; results demonstrated that FXIIIa inhibitor can be incorporated and released from silicone by using citric acid (CA) and sodium bicarbonate (SB) as additives and the drug release rate can be controlled by the amount of incorporated additives in the silicone matrix. Furthermore, it was deemed that the inhibitor was still biologically active subsequent to being released from the silicone elastomer strips. Morphological analysis confirmed the formation of channels and cracks inside the specimens upon the addition of CA and SB. Nevertheless, the tensile strength, in addition to Young's modulus of silicone elastomer strips, decreased constantly with an increasing amount of amalgamated CA/ SB in the formulations. According to our results, incorporation of FXIIIa inhibitor into catheters and other medical implant devices could offer new perspectives in preventing bio-material associated infections and thrombosis. The use of tissue transglutaminase (T02) inhibitor for treating of liver fibrosis was also investigated. Liver fibrosis is characterized by increased synthesis and decreased degradation of the extracellular matrix (ECM). Transglutaminase-mediated covalent cross-linking is involved in the stabilization of ECM in human liver fibrosis. Thus, TG2 inhibitors may be used to counteract the decreased degradation of the ECM. The potential of a liposome based drug delivery system for site specific delivery of the fluorescent TG2 inhibitor into the liver was investigated; results indicated that the TG2 inhibitor can be successfully integrated into liposomes and delivered to the liver, therefore demonstrating that liposomes can be employed for site-specific delivery of TG2 inhibitors into the liver and TG2 inhibitor incorporating liposomes could offer a new approach in treating liver fibrosis and its end stage disease cirrhosis.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Objectives: A rapid random amplification of polymorphic DNA (RAPD) technique was developed to distinguish between strains of coagulase-negative staphylococci (CoNS) involved in central venous catheter (CVC)-related bloodstream infection. Its performance was compared with that of pulsed-field gel electrophoresis (PFGE). Methods: Patients at the University Hospital Birmingham NHS Foundation Trust, U.K. who underwent stem cell transplantation and were diagnosed with CVC-related bloodstream infection due to CoNS whilst on the bone marrow transplant unit were studied. Isolates of CoNS were genotyped by PFGE and RAPD, the latter employing a single primer and a simple DNA extraction method. Results: Both RAPD and PFGE were highly discriminatory (Simpson's diversity index, 0.96 and 0.99, respectively). Within the 49 isolates obtained from blood cultures of 33 patients, 20 distinct strains were identified by PFGE and 25 by RAPD. Of the 25 strains identified by RAPD, nine clusters of CoNS contained isolates from multiple patients, suggesting limited nosocomial spread. However, there was no significant association between time of inpatient stay and infection due to any particular strain. Conclusion: The RAPD technique presented allows CoNS strains to be genotyped with high discrimination within 4 h, facilitating real-time epidemiological investigations. In this study, no single strain of CoNS was associated with a significant number of CVC-related bloodstream infections. © 2005 Published by Elsevier Ltd on behalf of the British Infection Society.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Intravascular catheters are one of the main causes of bacteraemia and septicaemia in hospitalised patients and continue to be associated with a significant morbidity and mortality. Two main types of infections occur, they can be either localised at the catheter insertion site of systemic with a septicaemia. The clinical parameters related to these infections are presented. The laboratory diagnosis of these infections is also extensively reviewed and recommendations are made as to the most appropriate diagnostic method to be used. © 2005 The British Infection Society. Published by Elsevier Ltd. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

OBJECTIVE: To synthesise the available evidence and estimate the comparative efficacy of control strategies to prevent total hip replacement (THR)-related surgical site infections (SSIs) using a mixed treatment comparison. DESIGN: Systematic review and mixed treatment comparison. SETTING: Hospital and other healthcare settings. PARTICIPANTS: Patients undergoing THR. PRIMARY AND SECONDARY OUTCOME MEASURES: The number of THR-related SSIs occurring following the surgical operation. RESULTS: 12 studies involving 123 788 THRs and 9 infection control strategies were identified. The strategy of 'systemic antibiotics+antibiotic-impregnated cement+conventional ventilation' significantly reduced the risk of THR-related SSI compared with the referent strategy (no systemic antibiotics+plain cement+conventional ventilation), OR 0.13 (95% credible interval (CrI) 0.03-0.35), and had the highest probability (47-64%) and highest median rank of being the most effective strategy. There was some evidence to suggest that 'systemic antibiotics+antibiotic-impregnated cement+laminar airflow' could potentially increase infection risk compared with 'systemic antibiotics+antibiotic-impregnated cement+conventional ventilation', 1.96 (95% CrI 0.52-5.37). There was no high-quality evidence that antibiotic-impregnated cement without systemic antibiotic prophylaxis was effective in reducing infection compared with plain cement with systemic antibiotics, 1.28 (95% CrI 0.38-3.38). CONCLUSIONS: We found no convincing evidence in favour of the use of laminar airflow over conventional ventilation for prevention of THR-related SSIs, yet laminar airflow is costly and widely used. Antibiotic-impregnated cement without systemic antibiotics may not be effective in reducing THR-related SSIs. The combination with the highest confidence for reducing SSIs was 'systemic antibiotics+antibiotic-impregnated cement+conventional ventilation'. Our evidence synthesis underscores the need to review current guidelines based on the available evidence, and to conduct further high-quality double-blind randomised controlled trials to better inform the current clinical guidelines and practice for prevention of THR-related SSIs.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Background:Human papillomavirus (HPV) variants differ in their biological and chemical properties, and therefore, may present differences in pathogenicity. Most authors classified variants based on the phylogenetic analysis of L1 region. Nevertheless, recombination in HPV samples is becoming a usual finding and thus, characterizing genetic variability in other regions should be essential. Objectives:We aimed to characterize the genetic variability of HPV 18 in 5 genomic regions: E6, E7, E4, L1 and the Upstream Regulatory Region (URR), working with both single infection and multiple HPV infection samples. Furthermore, we aimed to assess the prevalence of HPV 18 variants in our region and look for possible existence of recombination as well as analyze the relationship between these variants and the type of lesion. Methods: From 2007 to 2010, Clinical Microbiology and Infection Control Department analyzed 44 samples which were positive for HPV 18. Genetic variability was determined in PCR products and variants were assigned to European, Asian-amerindian or African lineage. Recombination and association of variants with different types of lesion was studied. Results: Genetic analysis of the regions revealed a total of 56 nucleotide variations. European, African and Asian-amerindian variants were found in 25/44 (56.8%), 10/44 (22.7%) and 5/44 (11.4%) samples, respectively. We detected the presence of recombinant variants in 2/44 (4.5%) cases. Samples taken from high-grade squamous intraepithelial lesions (H-SIL) only presented variants with specific-african substitutions. Conclusions: Multiple HPV infection, non-european HPV variants prevalence and existence of recombination are considered risk factors for HPV persistence and progression of intraepithelial abnormalities, and therefore, should be taken into consideration in order to help to design and optimize diagnostics protocols as well as improve epidemiologic studies. Our study is one of the few studies in Spain which analyses the genetic variability of HPV18 and we showed the importance of characterizing more than one genomic region in order to detect recombination and classify HPV variants properly

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Staphylococcus epidermidis, the most frequently isolated coagulase-negative staphylococcus, is the leading cause of infection related to implanted medical devices (IMDs). This is directly related to its capability to establish multilayered, highly structured biofilms on artificial surfaces. At present, conventional systemic therapies using standard antimicrobial agents represent the main strategy to treat and prevent medical device-associated infections. However, device-related infections are notoriously difficult to treat and bacteria within biofilm communities on the surface of IMDs frequently outlive treatment, and removal of the medical device is often required for successful therapy. Importantly, major advances in this research area have been made, leading to a greater understanding of the complexities of biofilm formation of S. epidermidis and resulting in significant developments in the treatment and prevention of infections related to this member of the coagulase-negative group of staphylococci. This review will examine the pathogenesis of the clinically significant S. epidermidis and provide an overview of the conventional and emerging antibiofilm approaches in the management of medical device-associated infections related to this important nosocomial pathogen.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Medical device related infections are becoming an increasing prevalent area of infectious disease. They can be attributed to a multitude of factors from an increasing elderly population with reduced immunological status to increasing microbial resistance and evolution. Of greatest significance is the failure of standard antimicrobial regimens to eradicate biomaterial-related infections due to the formation of microbial biofilms consisting of extracellular polymeric substances. Biofilms form and thrive at the abiotic device surface where nutrients are more concentrated and symbiotic colonies can be formed. The formation of a biofilm matrix occurs in a series of steps beginning with reversible attachment of bacteria to the surface of the substrate and terminating in dispersion of mature biofilm microcolonies that aim to colonise fresh surfaces high in nutrients. Mature biofilms can resist 10-1000 times the concentrations of standard antibiotic regimens that are required to kill genetically equivalent planktonic forms. The extent of the infection and the pathogen(s) present can be attributed to both the form and location of the device. It is important that preventative measures and treatment strategies relate to combating the causative microorganisms. Preventative measures include: the use of anti-infective biomaterials that can be coated or incorporated with standard or innovative antimicrobials; modified anti-adhesive medical devices; environmental sterilisation protocols and prophylactic drug therapy. Treatment of established infection may require removal of the device or if deemed possible the device may be salvageable through the initiation of antimicrobial therapy. The increasing spectre of antibiotic resistance and medical device related infections are a large and increasing burden on health care systems and the patient’s quality of life and long term prognosis. As an infectious disease it represents one of the most difficult challenges facing modern science and healthcare.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The aim of the present study was to describe the practice of central venous catheter (CVC) removal and outcomes of catheter-related bloodstream infection (CR-BSI) in adult haematology patients. Patients were identified retrospectively according to diagnosis coding of inpatient episodes and evaluated when, on examination of medical records, there had been evidence of sepsis with strong clinical suspicion that the source was the CVC. Demographic and bacteriological data, as well as therapeutic measures and clinical outcomes, were recorded. One hundred and three patient episodes were evaluated. The most frequent type of CVC was the Hickman catheter and the most frequently isolated pathogen was coagulase-negative staphylococci. Twenty-five percent of episodes were managed with catheter removal. Treatment failure, defined as recurrence of infection within 90 days or mortality attributed to sepsis within 30 days, occurred significantly more frequently in the group managed without catheter removal (52.5% versus 4%, P

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Infections associated with implants are increasingly important in modem medicine. Biofilms are the cause that these infections are more difficult to diagnose and to cure. Particularly low-grade infections are difficult to distinguish from aseptic failure, because they often present with early loosening and persisting pain. For an accurate diagnosis, clinical signs and symptoms, laboratory markers of infection, microbiology, histology and imaging examinations are needed. The treatment goal is eradication of infection and an optimal functional result. Successful treatment requires adequate surgical procedure combined with long-term antimicrobial therapy, ideally with an agent acting on biofilms.