954 resultados para CANCER-RISK ASSESSMENT


Relevância:

100.00% 100.00%

Publicador:

Resumo:

With the smartphone revolution, consumer-focused mobile medical applications (apps) have flooded the market without restriction. We searched the market for commercially available apps on all mobile platforms that could provide automated risk analysis of the most serious skin cancer, melanoma. We tested 5 relevant apps against 15 images of previously excised skin lesions and compared the apps' risk grades to the known histopathologic diagnosis of the lesions. Two of the apps did not identify any of the melanomas. The remaining 3 apps obtained 80% sensitivity for melanoma risk identification; specificities for the 5 apps ranged from 20%-100%. Each app provided its own grading and recommendation scale and included a disclaimer recommending regular dermatologist evaluation regardless of the analysis outcome. The results indicate that autonomous lesion analysis is not yet ready for use as a triage tool. More concerning is the lack of restrictions and regulations for these applications.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Airborne particles, including both ultrafine and supermicrometric particles, contain various carcinogens. Exposure and risk-assessment studies regularly use particle mass concentration as dosimetry parameter, therefore neglecting the potential impact of ultrafine particles due to their negligible mass compared to supermicrometric particles. The main purpose of this study was the characterization of lung cancer risk due to exposure to polycyclic aromatic hydrocarbons and some heavy metals associated with particle inhalation by Italian non-smoking people. A risk-assessment scheme, modified from an existing risk model, was applied to estimate the cancer risk contribution from both ultrafine and supermicrometric particles. Exposure assessment was carried out on the basis of particle number distributions measured in 25 smoke-free microenvironments in Italy. The predicted lung cancer risk was then compared to the cancer incidence rate in Italy to assess the number of lung cancer cases attributed to airborne particle inhalation, which represents one of the main causes of lung cancer, apart from smoking. Ultrafine particles are associated with a much higher risk than supermicrometric particles, and the modified risk-assessment scheme provided a more accurate estimate than the conventional scheme. Great attention has to be paid to indoor microenvironments and, in particular, to cooking and eating times, which represent the major contributors to lung cancer incidence in the Italian population. The modified risk assessment scheme can serve as a tool for assessing environmental quality, as well as setting up exposure standards for particulate matter.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

PURPOSE: Risk-stratified guidelines can improve quality of care and cost-effectiveness, but their uptake in primary care has been limited. MeTree, a Web-based, patient-facing risk-assessment and clinical decision support tool, is designed to facilitate uptake of risk-stratified guidelines. METHODS: A hybrid implementation-effectiveness trial of three clinics (two intervention, one control). PARTICIPANTS: consentable nonadopted adults with upcoming appointments. PRIMARY OUTCOME: agreement between patient risk level and risk management for those meeting evidence-based criteria for increased-risk risk-management strategies (increased risk) and those who do not (average risk) before MeTree and after. MEASURES: chart abstraction was used to identify risk management related to colon, breast, and ovarian cancer, hereditary cancer, and thrombosis. RESULTS: Participants = 488, female = 284 (58.2%), white = 411 (85.7%), mean age = 58.7 (SD = 12.3). Agreement between risk management and risk level for all conditions for each participant, except for colon cancer, which was limited to those <50 years of age, was (i) 1.1% (N = 2/174) for the increased-risk group before MeTree and 16.1% (N = 28/174) after and (ii) 99.2% (N = 2,125/2,142) for the average-risk group before MeTree and 99.5% (N = 2,131/2,142) after. Of those receiving increased-risk risk-management strategies at baseline, 10.5% (N = 2/19) met criteria for increased risk. After MeTree, 80.7% (N = 46/57) met criteria. CONCLUSION: MeTree integration into primary care can improve uptake of risk-stratified guidelines and potentially reduce "overuse" and "underuse" of increased-risk services.Genet Med 18 10, 1020-1028.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

BACKGROUND: A possible strategy for increasing smoking cessation rates could be to provide smokers who have contact with healthcare systems with feedback on the biomedical or potential future effects of smoking, e.g. measurement of exhaled carbon monoxide (CO), lung function, or genetic susceptibility to lung cancer. OBJECTIVES: To determine the efficacy of biomedical risk assessment provided in addition to various levels of counselling, as a contributing aid to smoking cessation. SEARCH STRATEGY: We systematically searched the Cochrane Collaboration Tobacco Addiction Group Specialized Register, Cochrane Central Register of Controlled Trials 2008 Issue 4, MEDLINE (1966 to January 2009), and EMBASE (1980 to January 2009). We combined methodological terms with terms related to smoking cessation counselling and biomedical measurements. SELECTION CRITERIA: Inclusion criteria were: a randomized controlled trial design; subjects participating in smoking cessation interventions; interventions based on a biomedical test to increase motivation to quit; control groups receiving all other components of intervention; an outcome of smoking cessation rate at least six months after the start of the intervention. DATA COLLECTION AND ANALYSIS: Two assessors independently conducted data extraction on each paper, with disagreements resolved by consensus. Results were expressed as a relative risk (RR) for smoking cessation with 95% confidence intervals (CI). Where appropriate a pooled effect was estimated using a Mantel-Haenszel fixed effect method. MAIN RESULTS: We included eleven trials using a variety of biomedical tests. Two pairs of trials had sufficiently similar recruitment, setting and interventions to calculate a pooled effect; there was no evidence that CO measurement in primary care (RR 1.06, 95% CI 0.85 to 1.32) or spirometry in primary care (RR 1.18, 95% CI 0.77 to 1.81) increased cessation rates. We did not pool the other seven trials. One trial in primary care detected a significant benefit of lung age feedback after spirometry (RR 2.12; 95% CI 1.24 to 3.62). One trial that used ultrasonography of carotid and femoral arteries and photographs of plaques detected a benefit (RR 2.77; 95% CI 1.04 to 7.41) but enrolled a population of light smokers. Five trials failed to detect evidence of a significant effect. One of these tested CO feedback alone and CO + genetic susceptibility as two different intervention; none of the three possible comparisons detected significant effects. Three others used a combination of CO and spirometry feedback in different settings, and one tested for a genetic marker. AUTHORS' CONCLUSIONS: There is little evidence about the effects of most types of biomedical tests for risk assessment. Spirometry combined with an interpretation of the results in terms of 'lung age' had a significant effect in a single good quality trial. Mixed quality evidence does not support the hypothesis that other types of biomedical risk assessment increase smoking cessation in comparison to standard treatment. Only two pairs of studies were similar enough in term of recruitment, setting, and intervention to allow meta-analysis.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

BACKGROUND: A possible strategy for increasing smoking cessation rates could be to provide smokers who have contact with healthcare systems with feedback on the biomedical or potential future effects of smoking, e.g. measurement of exhaled carbon monoxide (CO), lung function, or genetic susceptibility to lung cancer. We reviewed systematically data on smoking cessation rates from controlled trials that used biomedical risk assessment and feedback. OBJECTIVES: To determine the efficacy of biomedical risk assessment provided in addition to various levels of counselling, as a contributing aid to smoking cessation. SEARCH STRATEGY: We systematically searched he Cochrane Collaboration Tobacco Addiction Group Specialized Register, Cochrane Central Register of Controlled Trials (CENTRAL), MEDLINE (1966 to 2004), and EMBASE (1980 to 2004). We combined methodological terms with terms related to smoking cessation counselling and biomedical measurements. SELECTION CRITERIA: Inclusion criteria were: a randomized controlled trial design; subjects participating in smoking cessation interventions; interventions based on a biomedical test to increase motivation to quit; control groups receiving all other components of intervention; an outcome of smoking cessation rate at least six months after the start of the intervention. DATA COLLECTION AND ANALYSIS: Two assessors independently conducted data extraction on each paper, with disagreements resolved by consensus. MAIN RESULTS: From 4049 retrieved references, we selected 170 for full text assessment. We retained eight trials for data extraction and analysis. One of the eight used CO alone and CO + Genetic Susceptibility as two different intervention groups, giving rise to three possible comparisons. Three of the trials isolated the effect of exhaled CO on smoking cessation rates resulting in the following odds ratios (ORs) and 95% confidence intervals (95% CI): 0.73 (0.38 to 1.39), 0.93 (0.62 to 1.41), and 1.18 (0.84 to 1.64). Combining CO measurement with genetic susceptibility gave an OR of 0.58 (0.29 to 1.19). Exhaled CO measurement and spirometry were used together in three trials, resulting in the following ORs (95% CI): 0.6 (0.25 to 1.46), 2.45 (0.73 to 8.25), and 3.50 (0.88 to 13.92). Spirometry results alone were used in one other trial with an OR of 1.21 (0.60 to 2.42).Two trials used other motivational feedback measures, with an OR of 0.80 (0.39 to 1.65) for genetic susceptibility to lung cancer alone, and 3.15 (1.06 to 9.31) for ultrasonography of carotid and femoral arteries performed in light smokers (average 10 to 12 cigarettes a day). AUTHORS' CONCLUSIONS: Due to the scarcity of evidence of sufficient quality, we can make no definitive statements about the effectiveness of biomedical risk assessment as an aid for smoking cessation. Current evidence of lower quality does not however support the hypothesis that biomedical risk assessment increases smoking cessation in comparison with standard treatment. Only two studies were similar enough in term of recruitment, setting, and intervention to allow pooling of data and meta-analysis.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

There is evidence that consumption of fish, especially oily fish, has substantial beneficial effects on health. In particular an inverse relationship of oily fish intake to coronary heart disease incidence has been established. These beneficial effects are ascribed to fish oil components including long chain ω-3 polyunsaturated fatty acids. On the other hand it should be noted that oily fish also contains hazardous substances such as dioxins, PCBs and methylmercury. Soy consumption has been associated with potential beneficial and adverse effects. The claimed benefits include reduced risk of cardiovascular disease; osteoporosis, breast and prostate cancer whereas potential adverse effects include impaired thyroid function, disruption of sex hormone levels, changes in reproductive function and increased breast cancer risk The two cases of natural foods highlight the need to consider both risks and benefits in order to establish the net health impact associated to the consumption of specific food products. Within the Sixth Framework programme of the European Commission, the BRAFO project was funded to develop a framework that allows for the quantitative comparison of human health risks and benefits in relation to foods and food compounds. This paper describes the application of the developed framework to two natural foods, farmed salmon and soy protein. We conclude that the BRAFO methodology is highly applicable to natural foods. It will help the benefit-risk managers in selecting the appropriate dietary recommendations for the population.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The cancer risks (CR) by oral ingestion, dermal absorption, and inhalation exposure of trihalomethanes (THM) from tap water of ten districts in Fortaleza, Brazil were estimated. The mean levels of THM compounds were obtained in Fortaleza tap water as follow: 63.9 mu g L(-1) for chloroform (CHCl(3)), 40.0 mu g L(-1) for bromodichloromethane (CHBrCl(2)), and 15.6 mu g L(-1) for dibromochloromethane (CHBr(2)Cl). Bromoform (CHBr(3)) was not detected. The mean CR for THMs in tap water is 3.96 x 10(-4). The results indicate that Fortaleza residents have a higher CR by inhalation than dermal absorption and oral ingestion. The CR for CHCl(3) contributes with 68% as compared with the total CR, followed by CHBrCl(2) (21%), and CHBr(2)Cl (11%). The hazard index (HI) is about ten times lower than unity, not indicating non-cancer effects.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Decision support tools for the assessment and management of breast cancer risk may improve uptake of prevention strategies. End-user input in the design of such tools is critical to increase clinical use. Before developing such a computerized tool, we examined clinicians' practice and future needs. Twelve breast surgeons, 12 primary care physicians and 5 practice nurses participated in 4 focus groups. These were recorded, coded, and analyzed to identify key themes. Participants identified difficulties assessing risk, including a lack of available tools to standardize practice. Most expressed confidence identifying women at potentially high risk, but not moderate risk. Participants felt a tool could especially reassure young women at average risk. Desirable features included: evidence-based, accessible (e.g. web-based), and displaying absolute (not relative) risks in multiple formats. The potential to create anxiety was a concern. Development of future tools should address these issues to optimize translation of knowledge into clinical practice.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The risk for venous thromboembolism (VTE) in medical patients is high, but risk assessment is rarely performed because there is not yet a good method to identify candidates for prophylaxis. Purpose: To perform a systematic review about VTE risk factors (RFs) in hospitalized medical patients and generate recommendations (RECs) for prophylaxis that can be implemented into practice. Data sources: A multidisciplinary group of experts from 12 Brazilian Medical Societies searched MEDLINE, Cochrane, and LILACS. Study selection: Two experts independently classified the evidence for each RF by its scientific quality in a standardized manner. A risk-assessment algorithm was created based on the results of the review. Data synthesis: Several VTE RFs have enough evidence to support RECs for prophylaxis in hospitalized medical patients (eg, increasing age, heart failure, and stroke). Other factors are considered adjuncts of risk (eg, varices, obesity, and infections). According to the algorithm, hospitalized medical patients ≥40 years-old with decreased mobility, and ≥1 RFs should receive chemoprophylaxis with heparin, provided they don't have contraindications. High prophylactic doses of unfractionated heparin or low-molecular-weight-heparin must be administered and maintained for 6-14 days. Conclusions: A multidisciplinary group generated evidence-based RECs and an easy-to-use algorithm to facilitate VTE prophylaxis in medical patients. © 2007 Rocha et al, publisher and licensee Dove Medical Press Ltd.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The purpose of the work reported here is to test reliable molecular profiles using routinely processed formalin-fixed paraffin-embedded (FFPE) tissues from participants of the clinical trial BIG 1-98 with a median follow-up of 60 months.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

We report the concentrations of 28 PAHs, 15 oxygenated PAHs (OPAHs) and 11 trace metals/metalloids (As, Cd, Co, Cr, Cu, Fe, Mn, Ni, Pb, Se, and Zn) in muscle and gut + gill tissues of demersal fishes (Drapane africana, Cynoglossus senegalensis and Pomadasys peroteti) from three locations along the coast of the Gulf of Guinea (Ghana). The concentrations of ∑ 28PAHs in muscle tissues averaged 192 ng g− 1 dw (range: 71–481 ng g− 1 dw) and were not statistically different between locations. The concentrations of ∑ 28 PAHs were higher in guts + gills than in muscles. The PAH composition pattern was dominated by low molecular weight compounds (naphthalene, alkyl-naphthalenes and phenanthrene). All fish tissues had benzo[a]pyrene concentrations lower than the EU limit for food safety. Excess cancer risk from consumption of some fish was higher than the guideline value of 1 × 10− 6. The concentrations of ∑ 15 OPAHs in fish muscles averaged 422 ng g− 1 dw (range: 28–1715 ng g− 1dw). The ∑ 15 OPAHs/∑ 16 US-EPA PAHs concentration ratio was > 1 in 68% of the fish muscles and 100% of guts + gills. The log-transformed concentrations of PAHs and OPAHs in muscles, guts + gills were significantly (p < 0.05) correlated with their octanol–water partitioning coefficients, strongly suggesting that equilibrium partitioning from water/sediment into fish tissue was the main mechanism of bioaccumulation. The trace metal concentrations in the fish tissues were in the medium range when compared to fish from other parts of the world. The concentrations of some trace metals (Cd, Cu, Fe, Mn, Zn) were higher in guts + gills than in muscle tissues. The target hazard quotients for metals were < 1 and did not indicate a danger to the local population. We conclude that the health risk arising from the consumption of the studied fish (due to their PAHs and trace metals content) is minimal.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The comparison of radiotherapy techniques regarding secondary cancer risk has yielded contradictory results possibly stemming from the many different approaches used to estimate risk. The purpose of this study was to make a comprehensive evaluation of different available risk models applied to detailed whole-body dose distributions computed by Monte Carlo for various breast radiotherapy techniques including conventional open tangents, 3D conformal wedged tangents and hybrid intensity modulated radiation therapy (IMRT). First, organ-specific linear risk models developed by the International Commission on Radiological Protection (ICRP) and the Biological Effects of Ionizing Radiation (BEIR) VII committee were applied to mean doses for remote organs only and all solid organs. Then, different general non-linear risk models were applied to the whole body dose distribution. Finally, organ-specific non-linear risk models for the lung and breast were used to assess the secondary cancer risk for these two specific organs. A total of 32 different calculated absolute risks resulted in a broad range of values (between 0.1% and 48.5%) underlying the large uncertainties in absolute risk calculation. The ratio of risk between two techniques has often been proposed as a more robust assessment of risk than the absolute risk. We found that the ratio of risk between two techniques could also vary substantially considering the different approaches to risk estimation. Sometimes the ratio of risk between two techniques would range between values smaller and larger than one, which then translates into inconsistent results on the potential higher risk of one technique compared to another. We found however that the hybrid IMRT technique resulted in a systematic reduction of risk compared to the other techniques investigated even though the magnitude of this reduction varied substantially with the different approaches investigated. Based on the epidemiological data available, a reasonable approach to risk estimation would be to use organ-specific non-linear risk models applied to the dose distributions of organs within or near the treatment fields (lungs and contralateral breast in the case of breast radiotherapy) as the majority of radiation-induced secondary cancers are found in the beam-bordering regions.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

ACCURACY OF THE BRCAPRO RISK ASSESSMENT MODEL IN MALES PRESENTING TO MD ANDERSON FOR BRCA TESTING Publication No. _______ Carolyn A. Garby, B.S. Supervisory Professor: Banu Arun, M.D. Hereditary Breast and Ovarian Cancer (HBOC) syndrome is due to mutations in BRCA1 and BRCA2 genes. Women with HBOC have high risks to develop breast and ovarian cancers. Males with HBOC are commonly overlooked because male breast cancer is rare and other male cancer risks such as prostate and pancreatic cancers are relatively low. BRCA genetic testing is indicated for men as it is currently estimated that 4-40% of male breast cancers result from a BRCA1 or BRCA2 mutation (Ottini, 2010) and management recommendations can be made based on genetic test results. Risk assessment models are available to provide the individualized likelihood to have a BRCA mutation. Only one study has been conducted to date to evaluate the accuracy of BRCAPro in males and was based on a cohort of Italian males and utilized an older version of BRCAPro. The objective of this study is to determine if BRCAPro5.1 is a valid risk assessment model for males who present to MD Anderson Cancer Center for BRCA genetic testing. BRCAPro has been previously validated for determining the probability of carrying a BRCA mutation, however has not been further examined particularly in males. The total cohort consisted of 152 males who had undergone BRCA genetic testing. The cohort was stratified by indication for genetic counseling. Indications included having a known familial BRCA mutation, having a personal diagnosis of a BRCA-related cancer, or having a family history suggestive of HBOC. Overall there were 22 (14.47%) BRCA1+ males and 25 (16.45%) BRCA2+ males. Receiver operating characteristic curves were constructed for the cohort overall, for each particular indication, as well as for each cancer subtype. Our findings revealed that the BRCAPro5.1 model had perfect discriminating ability at a threshold of 56.2 for males with breast cancer, however only 2 (4.35%) of 46 were found to have BRCA2 mutations. These results are significantly lower than the high approximation (40%) reported in previous literature. BRCAPro does perform well in certain situations for men. Future investigation of male breast cancer and men at risk for BRCA mutations is necessary to provide a more accurate risk assessment.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Conservative procedures in low-dose risk assessment are used to set safety standards for known or suspected carcinogens. However, the assumptions upon which the methods are based and the effects of these methods are not well understood.^ To minimize the number of false-negatives and to reduce the cost of bioassays, animals are given very high doses of potential carcinogens. Results must then be extrapolated to much smaller doses to set safety standards for risks such as one per million. There are a number of competing methods that add a conservative safety factor into these calculations.^ A method of quantifying the conservatism of these methods was described and tested on eight procedures used in setting low-dose safety standards. The results using these procedures were compared by computer simulation and by the use of data from a large scale animal study.^ The method consisted of determining a "true safe dose" (tsd) according to an assumed underlying model. If one assumed that Y = the probability of cancer = P(d), a known mathematical function of the dose, then by setting Y to some predetermined acceptable risk, one can solve for d, the model's "true safe dose".^ Simulations were generated, assuming a binomial distribution, for an artificial bioassay. The eight procedures were then used to determine a "virtual safe dose" (vsd) that estimates the tsd, assuming a risk of one per million. A ratio R = ((tsd-vsd)/vsd) was calculated for each "experiment" (simulation). The mean R of 500 simulations and the probability R $<$ 0 was used to measure the over and under conservatism of each procedure.^ The eight procedures included Weil's method, Hoel's method, the Mantel-Byran method, the improved Mantel-Byran, Gross's method, fitting a one-hit model, Crump's procedure, and applying Rai and Van Ryzin's method to a Weibull model.^ None of the procedures performed uniformly well for all types of dose-response curves. When the data were linear, the one-hit model, Hoel's method, or the Gross-Mantel method worked reasonably well. However, when the data were non-linear, these same methods were overly conservative. Crump's procedure and the Weibull model performed better in these situations. ^

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Currently, there is increasing use of nanomaterials in the food industry thanks to the many advantages offered and make the products that contain them more competitive in the market. Their physicochemical properties often differ from those of bulk materials, which require specialized risk assessment. This should cover the risks to the health of workers and consumers as well as possible environmental risks. The risk assessment methods must go updating due to more widespread use of nanomaterials, especially now that are making their way down to consumer products. Today there is no specific legislation for nanomaterials, but there are several european dispositions and regulations that include them. This review gives an overview of the risk assessment and the existing current legislation regarding the use of nanotechnology in the food industry.