A critical evaluation of secondary cancer risk models applied to Monte Carlo dose distributions of 2-dimensional, 3-dimensional conformal and hybrid intensity-modulated radiation therapy for breast cancer
Data(s) |
21/08/2014
|
---|---|
Resumo |
The comparison of radiotherapy techniques regarding secondary cancer risk has yielded contradictory results possibly stemming from the many different approaches used to estimate risk. The purpose of this study was to make a comprehensive evaluation of different available risk models applied to detailed whole-body dose distributions computed by Monte Carlo for various breast radiotherapy techniques including conventional open tangents, 3D conformal wedged tangents and hybrid intensity modulated radiation therapy (IMRT). First, organ-specific linear risk models developed by the International Commission on Radiological Protection (ICRP) and the Biological Effects of Ionizing Radiation (BEIR) VII committee were applied to mean doses for remote organs only and all solid organs. Then, different general non-linear risk models were applied to the whole body dose distribution. Finally, organ-specific non-linear risk models for the lung and breast were used to assess the secondary cancer risk for these two specific organs. A total of 32 different calculated absolute risks resulted in a broad range of values (between 0.1% and 48.5%) underlying the large uncertainties in absolute risk calculation. The ratio of risk between two techniques has often been proposed as a more robust assessment of risk than the absolute risk. We found that the ratio of risk between two techniques could also vary substantially considering the different approaches to risk estimation. Sometimes the ratio of risk between two techniques would range between values smaller and larger than one, which then translates into inconsistent results on the potential higher risk of one technique compared to another. We found however that the hybrid IMRT technique resulted in a systematic reduction of risk compared to the other techniques investigated even though the magnitude of this reduction varied substantially with the different approaches investigated. Based on the epidemiological data available, a reasonable approach to risk estimation would be to use organ-specific non-linear risk models applied to the dose distributions of organs within or near the treatment fields (lungs and contralateral breast in the case of breast radiotherapy) as the majority of radiation-induced secondary cancers are found in the beam-bordering regions. |
Formato |
application/pdf |
Identificador |
http://boris.unibe.ch/61602/1/0031-9155_59_16_4697.pdf Joosten, Andreas; Bochud, F; Moeckli, R (2014). A critical evaluation of secondary cancer risk models applied to Monte Carlo dose distributions of 2-dimensional, 3-dimensional conformal and hybrid intensity-modulated radiation therapy for breast cancer. Physics in medicine and biology, 59(16), pp. 4697-4722. Institute of Physics Publishing IOP 10.1088/0031-9155/59/16/4697 <http://dx.doi.org/10.1088/0031-9155/59/16/4697> doi:10.7892/boris.61602 info:doi:10.1088/0031-9155/59/16/4697 info:pmid:25082795 urn:issn:0031-9155 |
Idioma(s) |
eng |
Publicador |
Institute of Physics Publishing IOP |
Relação |
http://boris.unibe.ch/61602/ |
Direitos |
info:eu-repo/semantics/restrictedAccess |
Fonte |
Joosten, Andreas; Bochud, F; Moeckli, R (2014). A critical evaluation of secondary cancer risk models applied to Monte Carlo dose distributions of 2-dimensional, 3-dimensional conformal and hybrid intensity-modulated radiation therapy for breast cancer. Physics in medicine and biology, 59(16), pp. 4697-4722. Institute of Physics Publishing IOP 10.1088/0031-9155/59/16/4697 <http://dx.doi.org/10.1088/0031-9155/59/16/4697> |
Palavras-Chave | #610 Medicine & health |
Tipo |
info:eu-repo/semantics/article info:eu-repo/semantics/publishedVersion PeerReviewed |