361 resultados para BFB boiler
Resumo:
In this study, equations for the calculation of erosion wear caused by ash particles on convective heat exchanger tubes of steam boilers are presented. Anew, three-dimensional test arrangement was used in the testing of the erosion wear of convective heat exchanger tubes of steam boilers. When using the sleeve-method, three different tube materials and three tube constructions could be tested. New results were obtained from the analyses. The main mechanisms of erosionwear phenomena and erosion wear as a function of collision conditions and material properties have been studied. Properties of fossil fuels have also been presented. When burning solid fuels, such as pulverized coal and peat in steam boilers, most of the ash is entrained by the flue gas in the furnace. In bubbling andcirculating fluidized bed boilers, particle concentration in the flue gas is high because of bed material entrained in the flue gas. Hard particles, such as sharp edged quartz crystals, cause erosion wear when colliding on convective heat exchanger tubes and on the rear wall of the steam boiler. The most important ways to reduce erosion wear in steam boilers is to keep the velocity of the flue gas moderate and prevent channelling of the ash flow in a certain part of the cross section of the flue gas channel, especially near the back wall. One can do this by constructing the boiler with the following components. Screen plates can beused to make the velocity and ash flow distributions more even at the cross-section of the channel. Shield plates and plate type constructions in superheaters can also be used. Erosion testing was conducted with three types of tube constructions: a one tube row, an inline tube bank with six tube rows, and a staggered tube bank with six tube rows. Three flow velocities and two particle concentrations were used in the tests, which were carried out at room temperature. Three particle materials were used: quartz, coal ash and peat ash particles. Mass loss, diameter loss and wall thickness loss measurements of the test sleeves were taken. Erosion wear as a function of flow conditions, tube material and tube construction was analyzed by single-variable linear regression analysis. In developing the erosion wear calculation equations, multi-variable linear regression analysis was used. In the staggered tube bank, erosion wear had a maximum value in a tube row 2 and a local maximum in row 5. In rows 3, 4 and 6, the erosion rate was low. On the other hand, in the in-line tube bank the minimum erosion rate occurred in tube row 2 and in further rows the erosion had an increasing value, so that in a six row tube bank, the maximum value occurred in row 6.
Resumo:
Työn tärkeimpänä tavoitteena oli edistää ympäristöjärjestelmän laatimista Kvaerner Pulping, Power divisioonan Kattilat-liiketoimintayksikölle. Lisäksi tavoitteena oli tarkastella yritykseen kohdistuvia ympäristövaatimuksia ja niiden vaikutusta yrityksen toimintaan. Aluksi työssä tarkasteltiin ympäristöjärjestelmästandardien sisältöjä ja niiden eroja. Työssä käsiteltiin myös erilaisia elinkaarijohtamisen malleja, joita voidaan hyödyntää yrityksen kokonaisvaltaisessa ympäristöjärjestelmässä. Työssä tarkasteltiin myös sidosryhmien vaikutusta yrityksen ympäristötoimintaan. Kattilalaitostoimittajan tärkeimpiä asiakkaita ovat sellu- ja paperiteollisuus. Näihin yrityksiin on kohdistunut runsaan kymmenen vuoden aikana paineita ympäristötoiminnan tehostamiseksi. Tämän kehityksen seurauksena vastaavat tehostamispaineet ovat siirtymässä myös alihankkijoille, kuten kattilaitostoimittajille. Tehokkaan ympäristöjohtamisen takaamiseksi työssä määriteltiin ympäristövastuut ja –valtuudet sekä ympäristöpäämäärät ja –tavoitteet. Lisäksi tunnistettiin yrityksen toimintaan liittyvät ympäristönäkökohdat ja –riskit. Työn yhteydessä laadittiin ympäristöjärjestelmän luonnos, ja se sisältää jatkuvan parantamisen periaatteen. Työn yhteydessä laadittiin lisäksi Kvaerner Pulping Oy:n koelaitokselle ympäristölupahakemus. Työssä on kuvattu koelaitosta ja sen ympäristölupahakemukseen liittyviä asioita esimerkkinä parantuneesta ympäristöasioiden hoidosta.
Resumo:
Kaksifaasivirtauksen kuvaamiseen käytettävät mallit, ja menetelmät kaksifaasivirtauksen painehäviön määrittämiseksi kehittyvät yhä monimutkaisimmiksi. Höyrystinputkissa tapahtuvien painehäviöiden arvioinnin vaatiman laskennan suorittamiseksi tietokoneohjelman kehittäminen on välttämätöntä. Tässä työssä on kehitetty itsenäinen PC-ohjelma painehäviöiden arvioimiseksi pakotetulle konvektiovirtaukselle pystysuorissa höyrykattilan höyrystinputkissa. Veden ja vesihöyryn aineominaisuuksien laskentaan käytetään IAPWS-IF97 –yhtälökokoelmaa sekä muita tarvittavia IAPWS:n suosittelemia yhtälöitä. Höyrystinputkessa kulloinkin vallitsevan virtausmuodon määrittämiseen käytetään sovelluskelpoisia virtausmuotojen välisiä rajoja kuvaavia yhtälöitä. Ohjelmassa käytetään painehäviön määritykseen kirjallisuudessa julkaistuja yhtälöitä, virtausmuodosta riippuen, alijäähtyneelle virtaukselle, kupla-, tulppa- ja rengasvirtaukselle sekä tulistetun höyryn virtaukselle. Ohjelman laskemia painehäviöarvioita verrattiin kirjallisuudesta valittuihin mittaustuloksiin. Laskettujen painehäviöiden virhe vaihteli välillä –19.5 ja +23.9 %. Virheiden itseisarvojen keskiarvo oli 12.8 %.
Resumo:
Työssä tutkittiin Andritz-Ahlstrom toimittamien soodakattiloiden lämmönsiirtoa ANITA 2.20- suunnitteluohjelmalla feedback- laskentaa apuna käyttäen. Data laskentaan saatiin kattiloiden takuukokeissa mitatuista arvoista. Mittaukset on suoritettiin Andritz-Ahlstromin henkilökunnan toimesta tehdashenkilökunnan avustuksella. Feedback -laskenta tapahtui mittaustulosten perusteella, joten tiettyä virhettä luonnollisesti esiintyi. Aluksi laskettiin taseet molempien ekojen yli erikseen sekä molemmat yhdessä Excel-taulukkolaskentaohjelmalla. Täältä saatiin oletettu savukaasuvirtaus kattilassa. Tämän jälkeen lämpöpintoja muokattiin todellisuutta vastaaviksi yleislikaisuuskerrointa muuttamalla (overall fouling factor). Kertoimet ovat liikkuivat noin 0.4 ja 1.6 välillä riipuen kattilan tyypistä ja ANITAn oletuksesta lämpöpintojen likaisuudelle. Havaittin että yhtä varsinaista syytä lämpöpintojen eroavaisuuteen oletetusta ei saatu. Syitä toiminnan poikkeamiseen oli monia. Mm. etukammion koolla havaittiin olevan suurtakin vaikutusta tulistimien, etenkin savukaasuvirrassa ensimmäisen tulistimen toimintaan. Yleisesti todettiin muiden tulistimien vastaavan oletettua toimintaa. Keittopinnan ja ekonomiserien toimintaa tutkittiin hivenen suppeammin ja havaittiin niiden toimivan huomattavasti stabiilimmin kuin tulistimien. Likaisuus kertoimet oletetusta vaihtelivat noin ±20 %.
Resumo:
Työn tavoitteena oli tutkia vaikuttaako puupolttoaineen lisääminen turpeen joukkoon leijukerroskattilan hiukkaspäästöihin tai sähkösuodattimen erotusasteeseen. Työn teoriaosassa selvitettiin hiukkaspäästöjen muodostumista leijukerrospoltossa ja vertailtiin eri polttotekniikoiden hiukkaspäästöjä. Lisäksi esiteltiin erilaisia hiukkasten erottamiseen soveltuvia erotuslaitteita. Tarkastelussa keskityttiin sähkösuodattimeen, joka on yleisin hiukkasten erottamiseen käytettävä erotuslaite. Työn kokeellinen osa suoritettiin turvetta ja puuta polttavalla kuplivalla leijukerroskattilalla. Kokeellisessa osassa tutkittiin vaikuttaako puun lisäys syntyvien hiukkasten kokojakaumiin, sähkösuodattimen jälkeiseen kokonaishiukkaspäästöön tai sähkösuodattimen erotusasteeseen. Kokeet suoritettiin sekä pelkkänä turpeenpolttona (2 koetta), että kahdella eri puu/turve-polttoainesuhteella. Kokojakaumamittaukset suoritettiin lisäksi kahdella eri menetelmällä. Kokojakaumamittausten perusteella todettiin puun lisäyksen kasvattavan pienhiukkasten muodostumista. Pienhiukkasten osuus kasvoi sekapolton myötä myös sähkösuodattimen jälkeen. Sekapoltolla ei sen sijaan ollut selvää vaikutusta kokonaishiukkaspäästöön tai sähkösuodattimen erotusasteeseen.
Resumo:
Tämän työn tarkoituksena oli löytää keinoja erään leijukerroskattilan typenoksidipäästöjen vähentämiseksi. Koska päästöt olivat jo alunperin alhaiset leijukerrostekniikan ja hybridin SNCR/SCR –typenpoistolaitteiston ansiosta, päätettiin päästöjä lähteä vähentämään parantamalla ammoniakkiruiskutuksen säätöä. Alkuperäinen ammoniakkiruiskutuksen säätö oli liian hidas, jotta satunnaisten häiriöiden aiheuttamat typenoksidipiikit olisi pystytty poistamaan. Ammoniakkiruiskutusta parannettiin lisäämällä jokaiseen ammoniakkilinjaan mäntäpumput, joiden avulla ammoniakkia voidaan syöttää sinne, missä sitä eniten tarvitaan. Ammoniakkiruiskutuksen säätöön kehitettiin uusi sumeaan logiikkaan perustuva säätäjä. Myös muita kehittyneitä säätömenetelmiä kuten neuroverkkoa hyödynnettiin säätäjän kehityksessä. Ammoniakkiruiskutuksen säätäjää testattiin menestyksekkäästi Ruotsissa Brista Kraftin Märstassa sijaitsevalla voimalaitoksella
Resumo:
Työn tavoite oli kehittää karakterisointimenetelmät kalkkikiven ja polttoaineen tuhkan jauhautumisen ennustamiselle kiertoleijukattilan tulipesässä. Kiintoainekäyttäytymisen karakterisoinnilla ja mallintamisella voidaan tarkentaa tulipesän lämmönsiirron ja tuhkajaon ennustamista. Osittain kokeelliset karakterisointimenetelmät perustuvat kalkkikiven jauhautumiseen laboratoriokokoluokan leijutetussa kvartsiputkireaktorissa ja tuhkan jauhatumiseen rotaatiomyllyssä. Karakterisointimenetelmät ottavat huomioon eri-laiset toimintaolosuhteet kaupallisen kokoluokan kiertoleijukattiloissa. Menetelmät kelpoistettiin kaupallisen kokoluokan kiertoleijukattiloista mitattujen ja fraktioittaisella kiintoainemallilla mallinnettujen taseiden avulla. Kelpoistamistaseiden vähäisyydestä huolimatta karakterisointimenetelmät arvioitiin virhetarkastelujen perusteella järkeviksi. Karakterisointimenetelmien kehittämistä ja tarkentamista tullaan jatkamaan.
Resumo:
Better models are needed for radiative heat transfer in boiler furnaces. If the process is known better, combustion in the furnace can be optimized to produce low emissions. It makes the process to be environmental friendly. Furthermore, if there is a better model of the furnace it can more fully explain what is happening inside the furnace. Using of the model one can quickly and easily analyze how it operates with bio fuels, moist fuels or difficult fuels and improve the operation. Models helps with better estimation of furnace dimensions and result in more accurate understanding of operation. Key component lacking in these models is radiative heat transfer in particle laden gases. If there are no particles than radiative heat transfer can be calculated approximately. There are two problems with current models when used with flow modeling. The first one is a need to account for a particle laden gas and the second one is an absence of a fast algorithm. Fast calculation is needed if radiative heat transfer calculation is done for a large CDF model. Computations slow down if time is required for calculating radiative properties over and over again. This thesis presents a band model for radiative heat transfer in boiler furnaces. Advantage is a quickness of calculation and account of particles in the process.
Resumo:
A model to solve heat and mass balances during the offdesign load calculations was created. These equations are complex and nonlinear. The main new ideas used in the created offdesign model of a kraft recovery boiler are the use of heat flows as torn iteration variables instead of the current practice of using the mass flows, vectorizing equation solving, thus speeding up the process, using non dimensional variables for solving the multiple heat transfer surface problem and using a new procedure for calculating pressure losses. Recovery boiler heat and mass balances are reduced to vector form. It is shown that these vectorized equations can be solved virtually without iteration. The iteration speed is enhanced by the use of the derived method of calculating multiple heat transfer surfaces simultaneously. To achieve this quick convergence the heat flows were used as the torn iteration parameters. A new method to handle pressure loss calculations with linearization was presented. This method enabled less time to be spent calculating pressure losses. The derived vector representation of the steam generator was used to calculate offdesign operation parameters for a 3000 tds/d example recovery boiler. The model was used to study recovery boiler part load operation and the effect of the black liquor dry solids increase on recovery boiler dimensioning. Heat flows to surface elements for part load calculations can be closely approximated with a previously defined exponent function. The exponential method can be used for the prediction of fouling in kraft recovery boilers. For similar furnaces the firing of 80 % dry solids liquor produces lower hearth heat release rate than the 65 % dry solids liquor if we fire at constant steam flow. The furnace outlet temperatures show that capacity increase with firing rate increase produces higher loadings than capacity increase with dry solids increase. The economizers, boiler banks and furnaces can be dimensioned smaller if we increase the black liquor dry solids content. The main problem with increased black liquor dry solids content is the decrease in the heat available to superheat. Whenever possible the furnace exit temperature should be increased by decreasing the furnace height. The increase in the furnace exit temperature is usually opposed because of fear of increased corrosion.
Resumo:
It is often reasonable to convert old boiler to bubbling fluidized bed boiler instead of building a new one. Converted boiler consists of old and new heat surfaces which must be fitted to operate together. Prediction of heat transfer in not so ideal conditions sets challenges for designers. Two converted boilers situated in Poland were studied on the grounds of acceptance tests and further studies. Calculation of boiler process was performed with boiler design program. Main interest was heat transfer in superheaters and factors affecting it. Theory for heat transfer is presented according to information found from literature. Results obtained from experimental studies and calculations have been compared. With correct definitions calculated parameters corresponded well to measured data at boiler maximum design load. However overload situations revealed to be difficult to model at least without considering changes in the combustion process which requires readjustments to the design program input values.
Resumo:
Engineering and pricing of large recovery boiler were studied in this work. Engineering was carried out with Anita 4.2 which is an engineering program of Andritz. Key initial values were chosen with previous studies. Primary target of this work was to find out the consequences that furnace dimensions and furnace screen vertical part has to boiler pricing. Boilers that were engineered had different rate of furnace width and depth and different heat transfer plate count. Boiler balances were invariable. Boilers with different vertical screen construction were also calculated. First variation was boiler with vertical screen up to furnace roof. Other variation was to connect vertical screen to Pre-boiler generating bank inlet tubes. Total prices were calculated to engineered boilers. Pricing was sort out to heat transfers, high pressure pipes, steel structures, auxiliary equipments and civil/structural costs. This study did not notice parts of the boiler which costs do not vary with the construction of the boiler. Heat transfers had the largest share of costs. Boiler building had the most significant differences between the boilers. Furnace screen had also significant role especially to costs of the boiler building.
Resumo:
A distinctive design feature of steam boiler with natural circulation is the presence of the steam drum which plays a role of the separator of vapor from the flow of water-and-steam mixture coming into steam drum from the furnace tubes. Steam drum with unheated downcomer tubes, deducing from it, and riser (screen/furnace tubes) inside the furnace is a closed circulation loop in which movement of water (downcomer tubes) and water-and-steam mixture (riser tubes) is organized. The movement of the working fluid is appears due to occurrence of the natural pressure, determined by the difference in hydrostatic pressure and the mass of water and water-and-steam mixtures in downcomer and riser tubes and called the driving pressure of the natural circulation:
Resumo:
The aim of this work is to study the effect of different fuel mixtures on the operation of circulating fluidized bed (CFB) boiler. The applicability of heat balance modeling software IPSEpro to simulate CFB boiler operation is also investigated. The work discusses various types of boilers and methods of boiler operation. The fuel properties and the possible fuel influence on the boiler efficiency are described. Various biofuel types that are possible to use in combination with other fuels are presented. Some examples of the fuel mixtures use are given. A CFB boiler model has been constructed using IPSEpro and applied to analyze boiler operation outside design conditions. In the simulations, the effect of different load levels and moisture contents for the fuel mixture has been studied.
Resumo:
A distinctive design feature of steam boiler with natural circulation is the presence of the steam drum which plays a role of the separator of vapor from the flow of water-and-steam mixture coming into steam drum from the furnace tubes. Steam drum with unheated downcomer tubes, deducing from it, and riser (screen/furnace tubes) inside the furnace is a closed circulation loop in which movement of water (downcomer tubes) and water-and-steam mixture (riser tubes) is organized. The movement of the working fluid is appears due to occurrence of the natural pressure, determined by the difference in hydrostatic pressure and the mass of water and water-and-steam mixtures in downcomer and riser tubes and called the driving pressure of the natural circulation: S drive = H steam (ρ down + ρ mix) g where: ρ down - density of water in downcomer tubes; ρ mix - density of water in riser tubes; H steam - height of steam content section; g - acceleration of gravity. In steam boilers with natural circulation the circulation rate is usually between 10 and 30. Thus, consumption of water in the circulation circuit “circulation rate times” more than steam output of the boiler. There are two aspects of the design of natural water circulation loops. One is to ensure a sufficient mass flux of circulating water to avoid burnout of evaporator tubes. The other is to avoid tube wall temperature fluctuation and tube vibration due to oscillation of circulation velocity. The design criteria are therefore reduced, in principle, to those of critical heat flux, critical flow rate for burnout, and flow instability. In practical design, however, the circulation velocity and the void fraction at the evaporator tube outlet are used as the design criteria (Seikan I., et. al., 1999). This study has been made with assumption that the heat flux in the furnace of the boiler even all the time. The target of the study was to define the circulation rate of the boiler, thus average heat flux do not change it. I would like to acknowledge professionals from “Foster Wheeler” company for good and comfortable cooperation.
Resumo:
Palm oil is one of the two most important vegetable oils in the world's oil and fats market. The extraction and purification processes generate different kinds of waste generally known as palm oil mill effluent (POME). Earlier studies had indicated the possibility of using boiler fly ash to adsorb impurities and colour in POME treatment. The adsorption treatment of POME using boiler fly ash was further investigated in detail in this work with regards to the reduction of BOD, colour and TSS from palm oil mill effluent. The amount of BOD, colour and TSS adsorbed increased as the weight of the boiler fly ash used was increased. Also, the smaller particle size of 425µm adsorbed more than the 850µm size. Attempts were made to fit the experimental data with the Freundlich, Langmuir and Dubinin-Radushkevich isotherms. The R² values, which ranged from 0.8974-0.9898, 0.8848-0.9824 and 0.6235-0.9101 for Freundlich, Langmuir and Dubinin-Radushkevich isotherms respectively, showed that Freundlich isotherm gave a better fit followed by Langmuir and then Dubinin-Radushkevich isotherm. The sorption trend could be put as BOD > Colour > TSS. The apparent energy of adsorption was found to be 1.25, 0.58 and 0.97 (KJ/mol) for BOD, colour and TSS respectively, showing that sorption process occurs by physiosorption. Therefore, boiler fly ash is capable of reducing BOD, Colour and TSS from POME and hence could be used to develop a good adsorbent for POME treatment.