890 resultados para Artificial organs
Resumo:
Right heart dysfunction is one of the most serious complications following implantation of a left ventricular assist device (LVAD), often leading to the requirement for short or long term right ventricular support (RVAD). The inflow cannulation site induces major haemodynamic changes and so there is a need to optimize the site used depending on the patient's condition. Therefore, this study evaluated and compared the haemodynamic influence of right atrial (RAC) and right ventricular (RVC) inflow cannulation sites. An in-vitro, variable heart failure, mock circulation loop was used to compare RAC and RVC in mild and severe biventricular heart failure (BHF) conditions. In the severe BHF condition, higher ventricular ejection fraction (RAC: 13.6%, RVC: 32.7%) and thus improved heart chamber and RVAD washout was observed with RVC, which suggested this strategy might be preferable for long term support (ie. bridge to transplant or destination therapy) to reduce the risk of thrombus formation. In the mild BHF condition, higher pulmonary valve flow (RAC: 3.33 L/min, RVC: 1.97 L/min) and lower right ventricular stroke work (RAC: 0.10 W, RVC: 0.13 W) and volumes were recorded with RAC. These results indicate an improved potential for myocardial recovery, thus RAC should be chosen in this condition. This in-vitro study suggests that RVAD inflow cannulation site should be chosen on a patient-specific basis with a view to the support strategy to promote myocardial recovery or reduce the risk of long-term complications.
Resumo:
Biventricular support with dual rotary ventricular assist devices (VADs) has been implemented clinically with restriction of the right VAD (RVAD) outflow cannula to artificially increase afterload and, therefore, operate within recommended design speed ranges. However, the low preload and high afterload sensitivity of these devices increase the susceptibility of suction events. Active control systems are prone to sensor drift or inaccurate inferred (sensor-less) data, therefore an alternative solution may be of benefit. This study presents the in vitro evaluation of a compliant outflow cannula designed to passively decrease the afterload sensitivity of rotary RVADs and minimize left-sided suction events. A one-way fluid-structure interaction model was initially used to produce a design with suitable flow dynamics and radial deformation. The resultant geometry was cast with different initial cross-sectional restrictions and concentrations of a softening diluent before evaluation in a mock circulation loop. Pulmonary vascular resistance (PVR) was increased from 50 dyne s/cm5 until left-sided suction events occurred with each compliant cannula and a rigid, 4.5 mm diameter outflow cannula for comparison. Early suction events (PVR ∼ 300 dyne s/cm5) were observed with the rigid outflow cannula. Addition of the compliant section with an initial 3 mm diameter restriction and 10% diluent expanded the outflow restriction as PVR increased, thus increasing RVAD flow rate and preventing left-sided suction events at PVR levels beyond 1000 dyne s/cm5. Therefore, the compliant, restricted outflow cannula provided a passive control system to assist in the prevention of suction events with rotary biventricular support while maintaining pump speeds within normal ranges of operation.
Resumo:
Extracellular matrix (ECM) materials are widely used in cartilage tissue engineering. However, the current ECM materials are unsatisfactory for clinical practice as most of them are derived from allogenous or xenogenous tissue. This study was designed to develop a novel autologous ECM scaffold for cartilage tissue engineering. The autologous bone marrow mesenchymal stem cell-derived ECM (aBMSC-dECM) membrane was collected and fabricated into a three-dimensional porous scaffold via cross-linking and freeze-drying techniques. Articular chondrocytes were seeded into the aBMSC-dECM scaffold and atelocollagen scaffold, respectively. An in vitro culture and an in vivo implantation in nude mice model were performed to evaluate the influence on engineered cartilage. The current results showed that the aBMSC-dECM scaffold had a good microstructure and biocompatibility. After 4 weeks in vitro culture, the engineered cartilage in the aBMSC-dECM scaffold group formed thicker cartilage tissue with more homogeneous structure and higher expressions of cartilaginous gene and protein compared with the atelocollagen scaffold group. Furthermore, the engineered cartilage based on the aBMSC-dECM scaffold showed better cartilage formation in terms of volume and homogeneity, cartilage matrix content, and compressive modulus after 3 weeks in vivo implantation. These results indicated that the aBMSC-dECM scaffold could be a successful novel candidate scaffold for cartilage tissue engineering.
Resumo:
OBJECTIVE: Acute liver failure (ALF) is haemodynamically characterized by a hyperdynamic circulation. The aims of this study were to investigate the systemic and regional haemodynamics in ALF, to measure changes in nitric oxide metabolites (NOx) and to evaluate whether these haemodynamic disturbances could be attenuated with albumin dialysis. MATERIAL AND METHODS: Norwegian Landrace pigs (23-30 kg) were randomly allocated to groups as controls (sham-operation, n = 8), ALF (hepatic devascularization, n = 8) and ALF + albumin dialysis (n = 8). Albumin dialysis was started 2 h after ALF induction and continued for 4 h. Systemic and regional haemodynamics were monitored. Creatinine clearance, nitrite/nitrate and catecholamines were measured. A repeated measures ANOVA was used to analyse the data. RESULTS: In the ALF group, the cardiac index increased (PGT < 0.0001), while mean arterial pressure (PG = 0.02) and systemic vascular resistance decreased (PGT < 0.0001). Renal resistance (PG = 0.04) and hind-leg resistance (PGT = 0.003) decreased in ALF. There was no difference in jejunal blood flow between the groups. ALF pigs developed renal dysfunction with increased serum creatinine (PGT = 0.002) and decreased creatinine clearance (P = 0.02). Catecholamines were significantly higher in ALF, but NOx levels were not different. Albumin dialysis did not attenuate these haemodynamic or renal disturbances. CONCLUSIONS: The haemodynamic disturbances during the early phase of ALF are characterized by progressive systemic vasodilatation with no associated changes in metabolites of NO. Renal vascular resistance decreased and renal dysfunction developed independently of changes in renal blood flow. After 4 h of albumin dialysis there was no attenuation of the haemodynamic or renal disturbances.
Resumo:
Introducción: las terapias continuas de reemplazo renal son una importante medida a utilizar en los pacientes con lesión renal aguda que ingresan a la unidad de cuidado intensivo, la pérdida temprana del circuito por coagulación del mismo es una situación que afecta a este grupo de pacientes. Materiales y métodos: se realizo un estudio de casos y controles de una duración de tres meses tomando los pacientes que eran sometidos a terapia continua de reemplazo renal en la fundación Cardioinfantil, se eligieron como casos aquellos pacientes que no lograban completar 72 horas de terapia por perdida del circuito relacionada con coagulación, y aquellos que si se tomaron como controles, se analizaron ambos grupos en función de diferentes variables demográficas, clínicas y del circuito, tomando como análisis primario el primer filtro utilizado y haciendo un análisis secundario incluyendo todos los filtros. Resultados: se recolectaron 24 pacientes para el análisis primario y 101 filtros para el análisis secundario, el 37,5% de los filtros duró > 72 horas y 62,5%, menos de este tiempo. El puntaje APACHE II (OR: 0,76, p 0.003) y sitio de inserción femoral derecho (OR: 0.14, p 0.007) se encontraron protectoras para la disfunción temprana. Discusión: aunque no se alcanzó la muestra total, se encontró asociación protectora del acceso femoral derecho, que fue novedosa, pero requiere confirmación. El APACHE II, también protector, puede corresponder a un sesgo, se necesitan más estudios para aclarar estos hallazgos y determinar la presencia de otras variables que intervengan.
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
The purpose was to evaluate the cytotoxicity of two novel formulations (alpha and beta) of calcium phosphate cements. Positive control, represented by a commercial hydroxyapatite cement, and negative control were included for comparative purposes. A continuous lineage of fibroblastic cells was used, and the effect of the tested materials on both cell proliferation and viability was assessed by counting cell number on hemocytometer and by the trypan blue exclusion test, respectively. Study design attempted to simulate clinical use by allowing direct and indirect contact of cells and cements. Results were analyzed by the Kruskal-Wallis test and indicated that the beta formulation was extremely cytotoxic (P < 0.001), because this material induced the greatest reduction on cell proliferation and viability. The alpha formulation behaved similarly to the positive control regarding its effect on cell proliferation and viability. Thus, it is concluded that alpha formulation has promise for further evaluation of its behavior in vivo.
Resumo:
Major problems with the treatment of osteomyelitis are associated with poor antibiotic distribution at the site of infection due to limited blood circulation to the skeletal tissue. Improved treatment procedures have been used in drug delivery systems that include bioceramics and natural and synthetic polymers. This work reports the development of anionic collagen:hydroxyapatite composite paste for sustained antibiotic release. Antibiotic release by the composite was characterized by two steps. In the first, 15.0 +/- 4.9% was released in the first 5 h (n = 53) by a normal Fick diffusion mechanism. In the second step, only 16.8 +/- 2.2% was released after 7 days. In conclusion, hydroxyapatite:anionic collagen composite can be an efficient support for sustained antibiotic release in the treatment of osteomyelitis because most of the antibiotic release may be associated with composite bioresorption, thus permitting antibiotic release throughout the healing process. Hydroxyapatite:anionic collagen paste showed good biocompatibility associated with bone tissue growth with material still being observed after 60 days from the time of implants.
Resumo:
During knee ligament reconstruction, the tendon graft is tensioned to prevent the occurrence of excessive graft elongation during the postoperative period. Tensioning may be achieved by applying a cyclic or static load to the graft during fixation. Although this procedure is part of the surgery, there is no consensus in international literature regarding ideal tension levels to be used in this procedure. This study was conducted on 10 tendons of the human gracilis muscle and 10 tendons of semitendinosus muscle removed from five male cadavers whose mean age was 20.8 years. These tendons underwent 10 in vitro strain cycles at three levels of deformation (2.5, 3, and 4%) and the value of the deforming load used for each cycle was recorded. The statistical analysis demonstrated that in order to attain the same level of deformation during the 10 cycles there was a reduction in the value of strain applied to the graft, observed at the three levels of deformation. It was concluded that the semitendinosus tendon presents a more uniform mechanical behavior and that there is a need for new graft tensioning protocols that consider the force associated with deformation.
Resumo:
The aim of this work is the evaluation of four different heat exchangers used for myocardium during cardioplegic system in cardiac surgeries. Four types of shell and tube heat exchangers made of different exchange elements were constructed, as follows: stainless steel tubes, aluminium tubes, polypropylene hollow fiber, and bellows type. The evaluation was performed by in vitro tests of parameters such as heat transfer, pressure drop, and hemolysis tendency. The result has shown that all four systems tested were able to achieve the heat performance, and to offer low resistance to flow, and safety, as well as have low tendency to hemolysis. However, we can emphasize that the bellows type heat exchanger has a significant difference with regard to the other three types.
Resumo:
Despite their propensity for significant infectious and mechanical complications, tunneled central venous catheters (CVCs) have become a common means of vascular access in the world for patients requiring chronic hemodialysis for end-stage renal disease. The objective of this study was to explore if cryopreserved solutions of the thrombolytic agent alteplase could be used as an effective, safe, and economically reasonable alternative in hemodialysis patients with occluded tunneled CVC. Patients requiring chronic hemodialysis and presenting with occluded tunneled CVC received a sufficient volume of the alteplase solution to fill the occluded catheter. To make alteplase economically feasible, it was diluted to 1-mg/mL aliquots and they were stored at -20 degrees C until use. Eighty-one patients accounting for 179 attempted clearances were assessable for efficacy. One hundred forty-seven (82.1%) of the 179 catheter clearance attempts resulted in successful catheter clearance after one dose. Twenty-seven (15.1%) of all occluded CVCs were successful after two doses whereas five (2.8%) were not. No adverse events were reported. Cryopreserved 1-mg/mL aliquots of alteplase are safe and effective in the clearance of occluded CVC for hemodialysis patients.
Resumo:
Prolonged intermittent renal replacement therapy (PIRRT) has emerged as an alternative to continuous renal replacement therapy in the management of acute kidney injury (AKI) patients. This trial aimed to compare the dialysis complications occurring during different durations of PIRRT sessions in critically ill AKI patients. We included patients older than 18 years with AKI associated with sepsis admitted to the intensive care unit and using noradrenaline doses ranging from 0.3 to 0.7 mu g/kg/min. Patients were divided into two groups randomly: in G1, 6-h sessions were performed, and in G2, 10-h sessions were performed. Seventy-five patients were treated with 195 PIRRT sessions for 18 consecutive months. The prevalence of hypotension, filter clotting, hypokalemia, and hypophosphatemia was 82.6, 25.3, 20, and 10.6%, respectively. G1 was composed of 38 patients treated with 100 sessions, whereas G2 consisted of 37 patients treated with 95 sessions. G1 and G2 were similar in male predominance (65.7 vs. 75.6%, P=0.34), age (63.6 +/- 14 vs. 59.9 +/- 15.5 years, P=0.28) and Sequential Organ Failure Assessment score (SOFA; 13.1 +/- 2.4 vs. 14.2 +/- 3.0, P=0.2). There was no significant difference between the two groups in hypotension (81.5 vs. 83.7%, P=0.8), filter clotting (23.6 vs. 27%, P=0.73), hypokalemia (13.1 vs. 8.1%, P=0.71), and hypophosphatemia (18.4 vs. 21.6%, P=0.72). However, the group treated with sessions of 10h were refractory to clinical measures for hypotension, and dialysis sessions were interrupted more often (9.5 vs. 30.1%, P=0.03). Metabolic control and fluid balance were similar between G1 and G2 (blood urea nitrogen [BUN]: 81 +/- 30 vs. 73 +/- 33mg/dL, P=1.0; delivered Kt/V: 1.09 +/- 0.24 vs. 1.26 +/- 0.26, P=0.09; actual ultrafiltration: 1731 +/- 818 vs. 2332 +/- 947mL, P=0.13) and fluid balance (-731 +/- 125 vs. -652 +/- 141mL, respectively) . In conclusion, intradialysis hypotension was common in AKI patients treated with PIRRT. There was no difference in the prevalence of dialysis complications in patients undergoing different durations of PIRRT.
Resumo:
Thrombosis of tunneled central venous catheters (CVC) in hemodialysis (HD) patients is common and it can lead to the elimination of vascular sites. This study aimed to evaluate the incidence of thrombotic obstruction of tunneled CVC in HD patients and the efficacy of occlusion treatment with alteplase use, and identify factors associated with thrombotic occlusion. It was a prospective cohort study performed in two centers which evaluated the diagnosis and treatment of thrombotic occlusion of CVC in HD patients for 24 consecutive months. The catheter occlusion was defined as the difficulty infusing or withdrawing fluid from their paths. Alteplase dose was infused to fill the lumen of the occluded catheter and remained for 50 min. As there was no obstruction of the catheter, the procedure was repeated. Three hundred and thirty-nine CVC in 247 patients were evaluated and followed, totalling 67 244 CVC-days. One hundred fifty-seven patients had only one CVC, 88 patients had two CVC during the study, and two patients had three CVC. The median age was 58 (47–66) years, patients were predominantly men (54%), with diabetic nephropathy as the main cause of chronic kidney disease (44%), the internal jugular vein as the main site of implantation (82%), and duration of dialysis before CVC implantation of 119 (41.5 to 585.5) days. Eight hundred and fifteen occlusion episodes were diagnosed (12 episodes/1000 CVC-days), with primary success with alteplase in 596 episodes (77%) and secondary in 81 cases (10%). In 99 episodes (13%), success was not achieved after the second dose of alteplase. Two hundred and thirty CVC were removed during the study and the removal causes were arteriovenous fistula use in 88 patients (38.3%), infectious and mechanical complications in 89 (38.7%) and 21 (9.1%), respectively, and others (transplantation, transfer, or death) in 32 patients (13.9%). Adverse effects were also not observed. In the multivariate analysis, we identified the greatest number of days with CVC (OR = 1.02, CI = 1.01–1.04, P = 0.004), the presence of diabetes (OR = 1.560, CI = 1.351–1.894, P = 0.015), and exit site infection (ESI) (OR = 1.567 CI = 1347–1926, P = 0.023) as factors associated with obstruction. Thrombotic occlusion showed frequent mechanical complication in CVC of HD patients. We observed 12 episodes of obstruction per 1000 CVC-days, with a high success rate after alteplase use (87%). In the multivariate analysis, the time with CVC, the presence of diabetes, and ESI were identified as variables associated with thrombotic obstruction.