978 resultados para Arterial stenosis


Relevância:

40.00% 40.00%

Publicador:

Resumo:

BACKGROUND/AIMS: The present report examines a new pig model for progressive induction of high-grade stenosis, for the study of chronic myocardial ischemia and the dynamics of collateral vessel growth. METHODS: Thirty-nine Landrace pigs were instrumented with a novel experimental stent (GVD stent) in the left anterior descending coronary artery. Eight animals underwent transthoracic echocardiography at rest and under low-dose dobutamine. Seven animals were examined by nuclear PET and SPECT analysis. Epi-, mid- and endocardial fibrosis and the numbers of arterial vessels were examined by histology. RESULTS: Functional analysis showed a significant decrease in global left ventricular ejection fraction (24.5 +/- 1.6%) 3 weeks after implantation. There was a trend to increased left ventricular ejection fraction after low-dose dobutamine stress (36.0 +/- 6.6%) and a significant improvement of the impaired regional anterior wall motion. PET and SPECT imaging documented chronic hibernation. Myocardial fibrosis increased significantly in the ischemic area with a gradient from epi- to endocardial. The number of arterial vessels in the ischemic area increased and coronary angiography showed abundant collateral vessels of Rentrop class 1. CONCLUSION: The presented experimental model mimics the clinical situation of chronic myocardial ischemia secondary to 1-vessel coronary disease.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

We have used an experimental model of aorta stenosis, with a Plexiglas plug, simulating a stable atheromatous plaque that promotes local turbulence and thrombosis. With animal survival of more than 24 h, we followed the partial fibrinolysis of the thrombus as well as its posterior organization and incorporation to the arterial wall as a neointima for up to 30 days. The mushroom plug form permitted the development of recirculation and stasis areas around it, favouring this evolution. Despite noted limitations, this study demonstrates that thrombus incorporation can contribute to plaque extension, as it can promote recirculation and stasis areas.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Fibromuscular dysplasia (FMD) is an important cause of renal artery stenosis, particularly in young females. Polymorphisms of the renin-angiotensin (RA) system have been implicated in the pathogenesis of hypertension and atherosclerotic vascular disease, and may play a role in the development of FMD. Examination of polymorphisms by PCR for angiotensin-converting enzyme (ACE) I/D, angiotensin II type 1 receptor (AT(1)R) A1166C and angiotensinogen (AGT) M235T and T174M was undertaken in 43 patients with typical multifocal renal arterial FMD (MF-FMD) and in 89 controls. The age of NIF-FMD patients at the time of diagnosis of hypertension did not differ (38.6 + 11.1 years vs 35.5 +/- 10.3 years, P = 0.12) from controls and the proportion (95% vs 86%, P = 0.14) of females was similar. Allele frequencies did not differ significantly between groups, except that MF-FMD patients had a significantly higher frequency of the ACE I allele than control subjects (0.62 vs 0.47, P = 0.026). Since the ACE I allele is associated with lower circulating ACE levels and possibly lower tissue levels of angiotensin II (Ang II), and since Ang II modulates vascular smooth muscle cell growth and synthetic activity, the I allele might predispose to defective remodelling of the arterial media, and thus to the development of MF-FMD. This contrasts with atherosclerotic renal artery stenosis, coronary stent restenosis and carotid intimal thickening, which are diseases affecting the arterial intima, and which are associated with increased frequency of the D allele.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

PURPOSE: Inspite of the long experience with the treatment of intermittent claudication, little is known about the natural history of stenotic lesions in the iliac segment. With the advent of endovascular treatment, this knowledge has become important. METHODS: Fifty-two stenosis, diagnosed using arteriography, in 38 claudicant patients were analyzed. After a minimum time interval of 6 months, a magnetic resonance angiography was performed to determine whether there was arterial occlusion. The primary factors that could influence the progression of a stenosis were analyzed, such as risk factors (smoking, hypertension, diabetes, sex, and age), compliance with clinical treatment, initial degree of stenosis, site of the stenosis, and length of follow-up. RESULTS: The average length of follow-up was 39 months. From the 52 lesions analyzed, 13 (25%) evolved to occlusion. When occlusion occurred, there was clinical deterioration in 63.2% of cases. This association was statistically significant (P = .002). There was no statistically significant association of the progression of the lesion with the degree or site of stenosis, compliance with treatment, or length of follow-up. Patients who evolved to occlusion were younger (P = .02). The logistic regression model showed that the determinant factors for clinical deterioration were arterial occlusion and noncompliance with clinical treatment. CONCLUSIONS: The progression of a stenosis to occlusion, which occurred in 25% of the cases, caused clinical deterioration. Clinical treatment was important, but it did not forestall the arterial occlusion. Prevention of occlusion could be achieved by early endovascular intervention or with the development of drugs that might stabilize the atherosclerotic plaque.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Objectives Unipolar depression (UPD) is a leading cause of global burden of diseases, particularly among the elderly, whose treatment may be challenging. In such cases, ECT is often recommended due to its safety and efficacy. This report presents a case of a 67-year-old male inpatient that developed a rare cardiac complication during ECT. Methods Clinical case report with patient’s consent and bibliographic review. Results A 67-year-old male inpatient with recurrent severe psychotic depression was hospitalized and ECT was indicated after failure of the pharmacological treatment. A comprehensive clinical pre-evaluation revealed only nonspecific ST-segment changes in electrocardiogram. During the 7th ECT session, it was observed transitory ST-segment depression followed by a discrete increase of plasma troponin I. Severe tri-vessel coronary artery stenosis was found and a percutaneous coronary angioplasty was performed, with satisfactory psychiatric and cardiac outcomes. Conclusions Unipolar depression (UPD) and cardiovascular disease are often coexistent conditions, especially among the elderly. In the current case, myocardial ischemia was detected lately during ECT therapy and its treatment allowed the UPD treatment to be completed adequately.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

We report the case of a 7-year-old male child diagnosed with Williams-Beuren syndrome and arterial hypertension refractory to clinical treatment. The diagnosis was confirmed by genetic study. Narrowing of the descending aorta and stenosis of the renal arteries were also diagnosed. Systemic vascular alterations caused by deletion of the elastin gene may occur early in individuals with Williams-Beuren syndrome, leading to the clinical manifestation of systemic arterial hypertension refractory to drug treatment.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The present study was undertaken to examine the cross-sectional vascular compliance at the anastomotic site. METHODS AND MATERIAL: We performed end-to-end anastomosis on the carotid artery of six pigs using continuous 6/0 polypropylene. Four carotid arteries were excised and mounted in a perfusion chamber while the remaining two were left in living animals. We used pulsed ultrasound (NIUS 02) to generate detailed longitudinal profiles of diameter and compliance in the proximity and on the anastomosis. RESULTS: On the anastomosis, the vessel diameter decreases (-1 to -2.6% of diastolic diameter) when blood pressure increases with an exponential correlation (R2 = 0.75). The arterial compliance at the anastomosis was negative: the vessel cross-section reduction for a pulse pressure of 1 up to 32 mmHg was 0.9 to 2% of diastolic vessel cross-section. CONCLUSIONS: Vessel movement generated a dynamic stenosis whose magnitude seems to depend on blood pressure level. Increasing blood pressure causes the retraction of vessel ends which causes vessel lumen reduction. These results suggest that continuous suture does not provide the continuity of mechanical properties of the artery.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

PURPOSE: To implement a double-inversion bright-blood coronary MR angiography sequence using a cylindrical re-inversion prepulse for selective visualization of the coronary arteries. MATERIALS AND METHODS: Local re-inversion bright-blood magnetization preparation was implemented using a nonselective inversion followed by a cylindrical aortic re-inversion prepulse. After an inversion delay that allows for in-flow of the labeled blood-pool into the coronary arteries, three-dimensional radial steady-state free-precession (SSFP) imaging (repetition/echo time, 7.2/3.6 ms; flip angle, 120 degrees, 16 profiles per RR interval; field of view, 360 mm; matrix, 512, twelve 3-mm slices) is performed. Coronary MR angiography was performed in three healthy volunteers and in one patient on a commercial 1.5 Tesla whole-body MR System. RESULTS: In all subjects, coronary arteries were selectively visualized with positive contrast. In addition, a middle-grade stenosis of the proximal right coronary artery was seen in one patient. CONCLUSION: A novel T1 contrast-enhancement strategy is presented for selective visualization of the coronary arteries without extrinsic contrast medium application. In comparison to former arterial spin-labeling schemes, the proposed magnetization preparation obviates the need for a second data set and subtraction.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

PURPOSE: To assess the technical feasibility of multi-detector row computed tomographic (CT) angiography in the assessment of peripheral arterial bypass grafts and to evaluate its accuracy and reliability in the detection of graft-related complications, including graft stenosis, aneurysmal changes, and arteriovenous fistulas. MATERIALS AND METHODS: Four-channel multi-detector row CT angiography was performed in 65 consecutive patients with 85 peripheral arterial bypass grafts. Each bypass graft was divided into three segments (proximal anastomosis, course of the graft body, and distal anastomosis), resulting in 255 segments. Two readers evaluated all CT angiograms with regard to image quality and the presence of bypass graft-related abnormalities, including graft stenosis, aneurysmal changes, and arteriovenous fistulas. The results were compared with McNemar test with Bonferroni correction. CT attenuation values were recorded at five different locations from the inflow artery to the outflow artery of the bypass graft. These findings were compared with the findings at duplex ultrasonography (US) in 65 patients and the findings at conventional digital subtraction angiography (DSA) in 27. RESULTS: Image quality was rated as good or excellent in 250 (98%) and in 252 (99%) of 255 bypass segments, respectively. There was excellent agreement both between readers and between CT angiography and duplex US in the detection of graft stenosis, aneurysmal changes, and arteriovenous fistulas (kappa = 0.86-0.99). CT angiography and duplex US were compared with conventional DSA, and there was no statistically significant difference (P >.25) in sensitivity or specificity between CT angiography and duplex US for both readers for detection of hemodynamically significant bypass stenosis or occlusion, aneurysmal changes, or arteriovenous fistulas. Mean CT attenuation values ranged from 232 HU in the inflow artery to 281 HU in the outflow artery of the bypass graft. CONCLUSION: Multi-detector row CT angiography may be an accurate and reliable technique after duplex US in the assessment of peripheral arterial bypass grafts and detection of graft-related complications, including stenosis, aneurysmal changes, and arteriovenous fistulas.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The presence of peripheral arterial occlusive disease increases the morbidity and mortality of patients with coronary artery disease. The objective of the present study was to calculate the prevalence of peripheral arterial occlusive disease in patients referred for coronary angiography. This prevalence study was carried out at the Hemodynamics Unit of Hospital Santa Isabel, Salvador, Brazil, from December 2004 to April 2005. After approval by the Ethics Committee of the hospital, 397 patients with angiographic signs of coronary artery disease were enrolled. Diagnosis of peripheral arterial occlusive disease was made using the ankle-brachial blood pressure index (£0.90). Statistical analyses were performed using the z test and a level of significance of a = 5%, 95%CI, the chi-square test and t-test, and multiple logistic regression analysis. The prevalence of peripheral arterial occlusive disease was 34.3% (95%CI: 29.4-38.9). Mean age was 65.7 ± 9.4 years for patients with peripheral arterial occlusive disease, and 60.3 ± 9.8 years for patients without peripheral arterial occlusive disease (P = 0.0000003). The prevalence of peripheral arterial occlusive disease was 1.57 times greater in patients with hypertension (P = 0.007) and 2.91 times greater in patients with coronary stenosis ³50% (P = 0.002). Illiterate patients and those with little education had a 44% higher chance of presenting peripheral arterial occlusive disease probably as a result of public health prevention policies of limited effectiveness. The prevalence of peripheral arterial occlusive disease in patients referred to a tertiary care hospital in Salvador, Bahia, for coronary angiography, was 34.3%.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

L’athérosclérose est une maladie qui cause, par l’accumulation de plaques lipidiques, le durcissement de la paroi des artères et le rétrécissement de la lumière. Ces lésions sont généralement localisées sur les segments artériels coronariens, carotidiens, aortiques, rénaux, digestifs et périphériques. En ce qui concerne l’atteinte périphérique, celle des membres inférieurs est particulièrement fréquente. En effet, la sévérité de ces lésions artérielles est souvent évaluée par le degré d’une sténose (réduction >50 % du diamètre de la lumière) en angiographie, imagerie par résonnance magnétique (IRM), tomodensitométrie ou échographie. Cependant, pour planifier une intervention chirurgicale, une représentation géométrique artérielle 3D est notamment préférable. Les méthodes d’imagerie par coupe (IRM et tomodensitométrie) sont très performantes pour générer une imagerie tridimensionnelle de bonne qualité mais leurs utilisations sont dispendieuses et invasives pour les patients. L’échographie 3D peut constituer une avenue très prometteuse en imagerie pour la localisation et la quantification des sténoses. Cette modalité d’imagerie offre des avantages distincts tels la commodité, des coûts peu élevés pour un diagnostic non invasif (sans irradiation ni agent de contraste néphrotoxique) et aussi l’option d’analyse en Doppler pour quantifier le flux sanguin. Étant donné que les robots médicaux ont déjà été utilisés avec succès en chirurgie et en orthopédie, notre équipe a conçu un nouveau système robotique d’échographie 3D pour détecter et quantifier les sténoses des membres inférieurs. Avec cette nouvelle technologie, un radiologue fait l’apprentissage manuel au robot d’un balayage échographique du vaisseau concerné. Par la suite, le robot répète à très haute précision la trajectoire apprise, contrôle simultanément le processus d’acquisition d’images échographiques à un pas d’échantillonnage constant et conserve de façon sécuritaire la force appliquée par la sonde sur la peau du patient. Par conséquent, la reconstruction d’une géométrie artérielle 3D des membres inférieurs à partir de ce système pourrait permettre une localisation et une quantification des sténoses à très grande fiabilité. L’objectif de ce projet de recherche consistait donc à valider et optimiser ce système robotisé d’imagerie échographique 3D. La fiabilité d’une géométrie reconstruite en 3D à partir d’un système référentiel robotique dépend beaucoup de la précision du positionnement et de la procédure de calibration. De ce fait, la précision pour le positionnement du bras robotique fut évaluée à travers son espace de travail avec un fantôme spécialement conçu pour simuler la configuration des artères des membres inférieurs (article 1 - chapitre 3). De plus, un fantôme de fils croisés en forme de Z a été conçu pour assurer une calibration précise du système robotique (article 2 - chapitre 4). Ces méthodes optimales ont été utilisées pour valider le système pour l’application clinique et trouver la transformation qui convertit les coordonnées de l’image échographique 2D dans le référentiel cartésien du bras robotisé. À partir de ces résultats, tout objet balayé par le système robotique peut être caractérisé pour une reconstruction 3D adéquate. Des fantômes vasculaires compatibles avec plusieurs modalités d’imagerie ont été utilisés pour simuler différentes représentations artérielles des membres inférieurs (article 2 - chapitre 4, article 3 - chapitre 5). La validation des géométries reconstruites a été effectuée à l`aide d`analyses comparatives. La précision pour localiser et quantifier les sténoses avec ce système robotisé d’imagerie échographique 3D a aussi été déterminée. Ces évaluations ont été réalisées in vivo pour percevoir le potentiel de l’utilisation d’un tel système en clinique (article 3- chapitre 5).

Relevância:

30.00% 30.00%

Publicador:

Resumo:

FUNDAMENTO: A hipertrofia ventricular esquerda (HVE) é comum em pacientes com hipertensão arterial sistêmica (HAS) e estenose aórtica (EAo) e, com certa frequência, encontramos associação entre estas patologias. Mas, em tal situação, não está clara a importância de cada uma na HVE. OBJETIVO: 1 - Avaliar em pacientes portadores de EAo, submetidos previamente a estudo ecocardiográfico, a magnitude da HVE, nos casos de EAo isolada e associada à HAS; 2 - Avaliar o padrão de remodelamento geométrico nas duas situações. MÉTODOS: Estudo retrospectivo, observacional e transversal, incluindo 298 pacientes consecutivos, com EAo ao ecocardiograma. HVE foi considerada para massa miocárdica > 224g em homens e > 162g em mulheres. Os pacientes foram classificados como portadores de EAo leve (gradiente máximo < 30,0 mmHg), moderada (entre 30 e 50,0 mmHg) e grave (> 50,0 mmHg), além disso, foram separados em dois subgrupos: com e sem HAS. RESULTADOS: Nos três níveis de lesão aórtica, a massa ventricular esquerda foi maior na EAo associada à HAS do que na EAo isolada (EAo leve: 172 ± 45 vs 223 ± 73g, p < 0,0001; EAo moderada: 189 ± 77 vs 245 ± 81g, p = 0,0313; EAo grave: 200 ± 62 vs 252 ± 88g, p = 0,0372). Presença de HAS esteve associada a maior risco de HVE (OR = 2,1,IC95%:1,2-3,6; p = 0,012). Pacientes com EAo grave e HAS apresentaram predomínio de hipertrofia concêntrica, quando comparados com aqueles normotensos (p = 0,013). CONCLUSÃO: em pacientes com EAo, a presença de HAS foi um fator adicional de aumento da massa ventricular esquerda, interferindo também na geometria ventricular.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

OBJETIVO: Observar o comportamento da sutura arterial em aortas abdominais de coelhos em crescimento, comparando-se as técnicas contínua e com pontos separados, empregando-se dois tipos de fios: Polipropilene 7-0 (inabsorvível) e Polidioxanone 7-0 (absorvível). MÉTODOS: Grupos: GI - Controle (sem sutura); GII - Polipropilene, Pontos Separados; GIII - Polipropilene, Contínua; GIV - Polidioxanone, Pontos Separados e GV - Polidioxanone, Contínua. Cada grupo foi subdividido em quatro Momentos de Eutanásia: aos 7, 14, 30 e 60 dias de pós-operatório. Foram avaliados: peso dos animais, diâmetros e pulsos arteriais, estenose, trombose, aderências, aortografia, visibilidade do fio, cicatrização e microscopia. RESULTADOS: a) após 60 dias, o local da linha de sutura cresceu de forma significativa em todos os grupos; b) a técnica de sutura com pontos separados causou menor estenose da linha de sutura, observada tanto no ato cirúrgico, como na eutanásia dos animais; c) no exame histopatológico, as diferenças encontradas entre grupos foram transitórias, não persistindo após 60 dias de pós-operatório. CONCLUSÃO: O polidioxanone mostrou ser a melhor opção, entre os dois fios, para sutura de artérias em crescimento, pois causa pouca ou nenhuma restrição ao crescimento arterial na linha de sutura, mesmo quando se emprega a técnica contínua.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Atherosclerotic renal artery stenosis (RAS) and coronary artery disease (CAD) arise from the same multiple risk factors. The purpose of this study was to assess the frequency of previously undiagnosed CAD in patients with angiographically confirmed RAS, by conducting coronary arteriography in the same setting. of 57 consecutive patients referred for renal arteriography on clinical grounds during a 14-month period, 28 had no RAS and 6 had RAS, but previously documented CAD. of the remainder 23 patients. 17 (74%; CI 56%-92%) had both RAS and CAD (7 single vessel, 4 two-vessel, and 7 multivessel disease). The clinical characteristics, such as age, blood pressure (BP) levels, signs of heart failure, were no different between those with and without CAD, although the 4 diabetic patients, the 4 patients with fundoscopic findings of grade III retinopathy, 11 of 14 with peripheral arterial disease, and 7 of 8 patients with prior stroke belonged in the CAD group. None developed complications as a result of the two consecutive procedures. The data suggest that in patients with RAS the frequency of silent CAD is high and cannot be predicted on clinical grounds alone, therefore coronary angiography should be routinely recommended in the same setting.