37 resultados para Amputee
Resumo:
Individuals with limb amputation fitted with conventional socket-suspended prostheses often experience socket related discomfort leading to a significant decrease in quality of life.[1-14] Most of these concerns can be overcome with osseointegration, a direct skeletal fixation method where the prosthetic componentry are directly attached to the fixation, resulting in the redundancy of the traditional socket system. There are two stages of osseointegration; Stage one, a titanium implant is inserted into the marrow space of residual limb bone and Stage two, a titanium extension is attached to the fixture. This surgical procedure is currently blooming worldwide, particularly within Queensland. Whilst providing improvements in quality of life, this new method also has potential to minimise the cost required for an amputee to ambulate during daily living. Thus, the aim of this project was to compare the differences in mean cost of services, cost of componentry and labour hours when using osseointegration compared to traditional socket-based prostheses. Data were extracted from Queensland Artificial Limb Services (QALS) database to determine cost of services, type of services and labour hours required to maintain a prosthetic limb. Five trans-femoral amputee male participants (age 46.4±10.1 yrs; height 175.4±16.3 cm; mass 83.8±14.0 kg; time since second stage 22.0± 8.1 mths) met inclusion criteria which was patient had to be more than 12 months post stage two osseointegration procedure. The socket and osseointegration prosthesis variables examined were the mean hours of labour, mean cost of services and mean cost of prosthetic componentry. Statistical analyses were conducted using an ANOVA. The results identified that there were only significant differences in the number of labour hours (p = 0.005) and cost of services (p = 0.021) when comparing the socket and osseointegration prosthetic type. These results identified that the cost of componentry were comparable between the two methods.
Resumo:
Background Over the last two decades, Transcutaneous Bone-Anchored Prosthesis (TCBAP) has proven to be an effective alternative for prosthetic attachment for amputees, particularly for individuals unable to wear a socket. [1-17] However, the load transmitted through a typical TCBAP to the residual tibia and knee joint can be unbearable for transtibial amputees with knee arthritis. Aim A. To describe the surgical procedure combining TKR with TCBAP for the first time; and B. To present preliminary data on potential risks and benefits with assessment of clinical and functional outcomes at follow up Method We used a TCBAP connected to the tibial base plate of a Total Knee Replacement (TKR) prosthesis enabling the tibial residuum and the knee joint to act as weight sharing structures by transferring the load directly to the femur. We performed a standard hinged TKR connected to a custom made TCBAP at the first stage followed by creating a skin implant interface as a second stage. We retrospectively reviewed four cases of trans-tibial amputations presenting with knee joint arthritis. Patients were assessed clinically and functionally including standard measures of health-related quality of life, amputee mobility predictor tool, ambulation tests and actual activity level. Progress was monitored for 6-24 months. Results Clinical outcomes including adverse events show no major complications but one case of superficial infection. Functional outcomes improved for all participants as early as 6 months follow up. Discussion & Conclusion TKR and TCBAP were combined for the first time in this proof-of-concept case series. The preliminary outcomes indicated that this procedure is potentially a safe and effective alternative for this patient group despite the theoretical increase in risk of ascending infection through the skin-implant interface to the external environment. We suggest larger comparative series to further validate these results.
Resumo:
Background Over the last two decades, Transcutaneous Bone-Anchored Prosthesis (TCBAP) has proven to be an effective alternative for prosthetic attachment for above knee amputees, particularly for individuals suffering from socket interface related complications. [1-17] Amputees with a very short femoral residuum (<15 cm) are at a considerable higher risk for these complications as well as high risk of implant failure, if they underwent a typical TCBAP due to the relatively small bony-implant contact leading to a need of a novel technique. Aim A. To describe the surgical procedure combining THR with TCBAP for the first time; and B. To present preliminary data on potential risks and benefits with assessment of clinical and functional outcomes at follow up Method We used a TCBAP connected to the stem of a Total Hip Replacement (THR) prosthesis enabling the femoral residuum and the hip joint to act as weight sharing structures by transferring the load directly to the pelvis. We performed a tri-polar THR connected to a custom made TCBAP at the first stage followed by creating a skin implant interface as a second stage. We retrospectively reviewed three cases of transfemoral amputations presenting with extremely short femoral residuum. Patients were assessed clinically and functionally including standard measures of health-related quality of life, amputee mobility predictor tool, ambulation tests and actual activity level. Progress was monitored for 6-24 months. Results Clinical outcomes including adverse events show no major complications. Functional outcomes improved for all participants as early as 6 months follow up. All cases were wheelchair bound preoperatively (K0 – AMPRO) improved to walking with One stick (K3 – AMPRO) at 3 months follow up. Discussion & Conclusion THR and TCBAP were combined for the first time in this proof-of-concept case series. The preliminary outcomes indicated that this procedure is potentially a safe and effective alternative despite the theoretical increase in risk of ascending infection through the skin-implant interface to the external environment for this patient group. We suggest larger comparative series to further validate these results.
Resumo:
Use of socket prostheses Currently, for individuals with limb loss, the conventional method of attaching a prosthetic limb relies on a socket that fits over the residual limb. However, there are a number of issues concerning the use of a socket (e.g., blisters, irritation, and discomfort) that result in dissatisfaction with socket prostheses, and these lead ultimately a significant decrease in quality of life. Bone-anchored prosthesis Alternatively, the concept of attaching artificial limbs directly to the skeletal system has been developed (bone anchored prostheses), as it alleviates many of the issues surrounding the conventional socket interface.Bone anchored prostheses rely on two critical components: the implant, and the percutaneous abutment or adapter, which forms the connection for the external prosthetic system (Figure 1). To date, an implant that screws into the long bone of the residual limb has been the most common intervention. However, more recently, press-fit implants have been introduced and their use is increasing. Several other devices are currently at various stages of development, particularly in Europe and the United States. Benefits of bone-anchored prostheses Several key studies have demonstrated that bone-anchored prostheses have major clinical benefits when compared to socket prostheses (e.g., quality of life, prosthetic use, body image, hip range of motion, sitting comfort, ease of donning and doffing, osseoperception (proprioception), walking ability) and acceptable safety, in terms of implant stability and infection. Additionally, this method of attachment allows amputees to participate in a wide range of daily activities for a substantially longer duration. Overall, the system has demonstrated a significant enhancement to quality of life. Challenges of direct skeletal attachment However, due to the direct skeletal attachment, serious injury and damage can occur through excessive loading events such as during a fall (e.g., component damage, peri-prosthetic fracture, hip dislocation, and femoral head fracture). These incidents are costly (e.g., replacement of components) and could require further surgical interventions. Currently, these risks are limiting the acceptance of bone-anchored technology and the substantial improvement to quality of life that this treatment offers. An in-depth investigation into these risks highlighted a clear need to re-design and improve the componentry in the system (Figure 2), to improve the overall safety during excessive loading events. Aim and purposes The ultimate aim of this doctoral research is to improve the loading safety of bone-anchored prostheses, to reduce the incidence of injury and damage through the design of load restricting components, enabling individuals fitted with the system to partake in everyday activities, with increased security and self-assurance. The safety component will be designed to release or ‘fail’ external to the limb, in a way that protects the internal bone-implant interface, thus removing the need for restorative surgery and potential damage to the bone. This requires detailed knowledge of the loads typically experienced by the limb and an understanding of potential overload situations that might occur. Hence, a comprehensive review of the loading literature surrounding bone anchored prostheses will be conducted as part of this project, with the potential for additional experimental studies of the loads during normal activities to fill in gaps in the literature. This information will be pivotal in determining the specifications for the properties of the safety component, and the bone-implant system. The project will follow the Stanford Biodesign process for the development of the safety component.
Resumo:
Background The purpose of this presentation is to outline the relevance of the categorization of the load regime data to assess the functional output and usage of the prosthesis of lower limb amputees. The objectives are • To highlight the need for categorisation of activities of daily living • To present a categorization of load regime applied on residuum, • To present some descriptors of the four types of activity that could be detected, • To provide an example the results for a case. Methods The load applied on the osseointegrated fixation of one transfemoral amputee was recorded using a portable kinetic system for 5 hours. The load applied on the residuum was divided in four types of activities corresponding to inactivity, stationary loading, localized locomotion and directional locomotion as detailed in previously publications. Results The periods of directional locomotion, localized locomotion, and stationary loading occurred 44%, 34%, and 22% of recording time and each accounted for 51%, 38%, and 12% of the duration of the periods of activity, respectively. The absolute maximum force during directional locomotion, localized locomotion, and stationary loading was 19%, 15%, and 8% of the body weight on the anteroposterior axis, 20%, 19%, and 12% on the mediolateral axis, and 121%, 106%, and 99% on the long axis. A total of 2,783 gait cycles were recorded. Discussion Approximately 10% more gait cycles and 50% more of the total impulse than conventional analyses were identified. The proposed categorization and apparatus have the potential to complement conventional instruments, particularly for difficult cases.
Resumo:
Introdução – O efeito de êmbolo é um dos principais problemas relacionados com a eficácia de uma prótese. Uma diminuição do mesmo pode levar a uma marcha mais natural através do aumento da propriocetividade. Objetivos – Verificar se existe diferença de valores do efeito de êmbolo entre vários sistemas de suspensão para próteses transtibiais com a utilização de Liners e testar a aplicação de testes de imagiologia na análise da melhor solução protésica para um determinado indivíduo. Metodologia – Foi obtida uma radiografia da prótese em carga na posição ortostática, mantendo o peso do indivíduo igualmente distribuído pelos dois pés. Seguidamente foi realizada outra radiografia no plano sagital com o joelho com 30° de flexão, com a prótese suspensa e um peso de 5kg aplicado na extremidade distal da mesma durante 30 seg. Através destes dois exames efetuaram-se as medições do êmbolo para cada tipo de sistema de suspensão. Resultados – Dos quatro sistemas estudados apenas três apresentam valores de êmbolo, visto que um dos sistemas não criou suspensão suficiente para suportar o peso colocado na extremidade distal da prótese. Através das medições realizadas nos exames imagiológicos dos três sistemas pudemos encontrar variações de efeito de êmbolo que vão dos 47,91mm aos 72,55mm. Conclusão – Através da realização do estudo imagiológico verificaram-se diferenças a nível do efeito de êmbolo nos vários sistemas de suspensão, provando que esta é uma ferramenta viável na avaliação do mesmo. Também através da análise dos resultados ficou notório que o sistema de suspensão Vacuum Assisted Suspention System (VASS) é o que apresenta menos êmbolo.
Resumo:
Résumé Les premières études électrophysiologiques et anatomiques ont établi le rôle crucial du cortex somatosensoriel primaire et secondaire (SI et SII) dans le traitement de l'information somatosensorielle. Toutefois, les récentes avancées en techniques d’imagerie cérébrale ont mis en question leur rôle dans la perception somatosensorielle. La réorganisation du cortex somatosensoriel est un phénomène qui a été proposé comme cause de la douleur du membre fantôme chez les individus amputés. Comme la plupart des études se sont concentrées sur le rôle du SI, une étude plus approfondie est nécessaire. La présente série d'expériences implique une exploration du rôle des régions somatosensorielles dans la perception des stimuli douleureux et non-douleureux chez des volontaires sains et patients avec des douleurs de membre fantôme. La première étude expérimentale présentée dans le chapitre 3 est une méta-analyse des études de neuro-imagerie employant des stimuli nociceptifs chez des volontaires sains. En comparaison aux précédentes, la présente étude permet la génération de cartes quantitatives probabilistes permettant la localisation des régions activées en réponse à des stimuli nociceptifs. Le rôle du cortex somatosensoriel dans la perception consciente de stimuli chauds a été étudié dans le chapitre 4 grâce à une étude d'imagerie par résonance magnétique fonctionnelle, dans laquelle des stimuli thermiques douloureux et non-douloureux ont été administrés de manière contrebalancée. Grâce à cette procédure, la perception de la chaleur fut atténuée par les stimuli douloureux, ce qui permit la comparaison des stimuli consciemment perçus avec ceux qui ne le furent pas. Les résultats ont montrés que les stimulations chaudes perçues ont engendré l’activation de l’aire SI controlatérale, ainsi que de la région SII. Grâce à l’évaluation clinique de patients amputés présentant une altération de leurs perceptions somatosensorielles, il est également possible de dessiner un aperçu des régions corticales qui sous-tendent ces modifications perceptuelles. Dans le chapitre 5 nous avons émis l'hypothèse proposant que les sensations du membre fantôme représentent un corrélat perceptuel de la réorganisation somatotopique des représentations sensorielles corticales. En effet, la réorganisation des sensations peut donner des indices sur les régions impliquées dans la genèse des sensations référées. Ainsi, un protocole d’évaluation sensoriel a été administré à un groupe de patients affligés de douleur au niveau du membre fantôme. Les résultats ont montré que, contrairement aux études précédentes, les sensations diffèrent grandement selon le type et l'intensité des stimuli tactiles, sans évidence de la présence d’un modèle spatialement localisé. Toutefois, les résultats actuels suggèrent que les régions corticales à champs récepteurs bilatéraux présentent également des modifications en réponse à une déafférentation. Ces études présentent une nouvelle image des régions corticales impliquées dans la perception des stimuli somatosensoriels, lesquelles comprennent les aires SI et SII, ainsi que l'insula. Les résultats sont pertinents à notre compréhension des corrélats neurologiques de la perception somatosensorielle consciente.
Resumo:
Mémoire numérisé par la Division de la gestion de documents et des archives de l'Université de Montréal.
Resumo:
Introducción: El trasplante de mano es una opción en el tratamiento de pacientes amputados. Su recuperación funcional determina, junto con el manejo de la inmunosupresión, el éxito del trasplante. Este estudio buscó identificar y describir los resultados funcionales, sensibilidad y recuperación motora, en pacientes trasplantados. Metodología: Búsqueda sistemática de la literatura incluyendo estudios prospectivos, retrospectivos y reportes de caso en tres bases de datos primarias y una base de datos de revisiones sistemáticas, bajo criterios de búsqueda específicos. Resultados: Once artículos cumplieron con los criterios de inclusión. La discriminación de dos puntos, la estrognosis, el signo de Tinel, la temperatura, el tacto superficial y profundo y el dolor fueron evaluados. Seis pacientes recuperaron los tres últimos durante los primeros 12 meses, tres más lograron discriminación de dos puntos en los pulpejos entre 1.5 y 3 años. De los restantes uno tiene reporte de normalidad a los seis años y en el otro refieren disminución de la sensibilidad protectiva en el mismo plazo. El rango total de movilidad de los dedos sirvió como evaluación de la función motora en cinco pacientes, tres tuvieron reportes por debajo del 50% de lo normal al año del trasplante, el cuarto logró cerca de un 60%, el último fue artodesado. El tiempo mostró ser un factor para la mejoría en la valoración global de la extremidad superior mediante el uso del DASH. Discusión, conclusiones: es necesaria la estadarización y su publicación, de la medición de los resultados funcionales en los pacientes de trasplante de mano.
Resumo:
La utilización de las prótesis de miembro superior se ha convertido en un problema no solo en Colombia sino en el mundo. La experiencia con la prescripción de prótesis de miembro superior nos ha mostrado que en general los amputados las utilizan poco en las actividades
Resumo:
Introducción: En la literatura, han aparecido reportes de neoplasia escamosa de superficie ocular (NESO) asociado con pterigio en un mismo paciente. Sin embargo, Colombia no cuenta con una estadística para ninguna de estas patologías. Objetivos: Determinar la frecuencia de NESO en pterigios resecados, en la Fundación Oftalmológica Nacional. Identificar factores de riesgo y características clínicas que predispongan a su aparición. Metodología: Estudio descriptivo de corte transversal. Se realizó una clasificación prequirúrgica y estudio histopatológico de los pterigios resecados en 93 pacientes, para confirmar su coexistencia con NESO. Se efectuó un análisis de frecuencias para datos demográficos y factores de riesgo asociados su aparición. Resultados: La frecuencia de NESO asociado a pterigio fue 7,07%. De estos, 28,5% identificados como sospechosos en la evaluación preoperatoria. La mayoría se presentaron en mujeres (71,4%), las ocupaciones con mayor frecuencia: labores domésticas (42,8%) y el comercio (28.5%). La exposición a derivados del petróleo y tabaquismo fue del 14,28%. No se presentaron casos asociados a infección por VIH. No hubo diferencias estadísticamente significativas sobre la presencia de NESO al comparar los casos en edad (p=0,8), procedencia (p=0,6) tabaquismo (p=0,4), leucoplaquia (p=1,0), queratinización (p=0,137), o vasos amputados (p=0,137). Conclusiones: De los pacientes con diagnóstico histopatológico de NESO, un porcentaje mínimo es sospechado clínicamente. Además se encontró este diagnóstico en pacientes más jóvenes que lo reportado en la literatura. Se recomienda realizar estudios con mayor número de pacientes para una mejor identificación de factores de riesgo. Palabras clave:
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Objective: To review the literature to identify and synthesize the evidence on risk factors for patient falls in geriatric rehabilitation hospital settings. Data sources: Eligible studies were systematically searched on 16 databases from inception to December 2010. Review methods: The search strategies used a combination of terms for rehabilitation hospital patients, falls, risk factors and older adults. Cross-sectional, cohort, case-control studies and randomized clinical trials (RCTs) published in English that investigated risks for falls among patients ≥65 years of age in rehabilitation hospital settings were included. Studies that investigated fall risk assessment tools, but did not investigate risk factors themselves or did not report a measure of risk (e.g. odds ratio, relative risk) were excluded. Results: A total of 2,824 references were identified; only eight articles concerning six studies met the inclusion criteria. In these, 1,924 geriatric rehabilitation patients were followed. The average age of the patients ranged from 77 to 83 years, the percentage of women ranged from 56% to 81%, and the percentage of fallers ranged from 15% to 54%. Two were case-control studies, two were RCTs and four were prospective cohort studies. Several intrinsic and extrinsic risk factors for falls were identified. Conclusion: Carpet flooring, vertigo, being an amputee, confusion, cognitive impairment, stroke, sleep disturbance, anticonvulsants, tranquilizers and antihypertensive medications, age between 71 and 80, previous falls, and need for transfer assistance are risk factors for geriatric patient falls in rehabilitation hospital settings.
Resumo:
Thesis (Master's)--University of Washington, 2016-06
Resumo:
Thesis (Ph.D.)--University of Washington, 2016-06