859 resultados para Afm
Resumo:
This present work reports on development of an amperometric immunosensor for the diagnosis of Chagas' disease using a specific glycoprotein of the trypomastigote surface, which belongs to the Tc85-11 protein family of Trypanosoma cruzi (T cruzi). An atomically flat gold surface on a silicon substrate and gold screen-printed electrodes were functionalized with cystatrine and later activated with glutaraldehyde (GA), which was used to form covalent bonds with the purified recombinant antigen (Tc85-11). The antigen reacts with the antibody from the serum, and the affinity reaction was monitored directly using atomic force microscopy or amperometry through a secondary antibody tagged to peroxidase (HRP). Surface imaging allowed to us to differentiate the modification steps and antigen-antibody interaction allowed to distinguish the affinity reactions. In the amperometric immunosensor, peroxidase catalyses the L-2 formation in the presence of hydrogen peroxide and potassium iodide, and the reduction current intensity was measured at a given potential with screen-printed electrodes. The immunosensor was applied to sera of chagasic patients and patients having different systemic diseases. (c) 2006 Elsevier Ltd. All rights reserved.
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
In last decades, control of nonlinear dynamic systems became an important and interesting problem studied by many authors, what results the appearance of lots of works about this subject in the scientific literature. In this paper, an Atomic Force Microscope micro cantilever operating in tapping mode was modeled, and its behavior was studied using bifurcation diagrams, phase portraits, time history, Poincare maps and Lyapunov exponents. Chaos was detected in an interval of time; those phenomena undermine the achievement of accurate images by the sample surface. In the mathematical model, periodic and chaotic motion was obtained by changing parameters. To control the chaotic behavior of the system were implemented two control techniques. The SDRE control (State Dependent Riccati Equation) and Time-delayed feedback control. Simulation results show the feasibility of the bothmethods, for chaos control of an AFM system. Copyright © 2011 by ASME.
Resumo:
Pós-graduação em Ciência dos Materiais - FEIS
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
Nanocomposites were prepared from mixture of different concentrations of ferroelectric nanoparticles in an elastomeric matrix based on the vulcanized natural rubber. The morphological characterization of nanocomposites was carried out using Scanning electron microscopy (SEM), Transmission electron microscopy (TEM) and Atomic force microscopy (AFM). The nanocrystalline ferroelectric oxide is potassium strontium niobate (KSN) with stoichiometry KSr2Nb5O15, and was synthesized by the chemical route using a modified polyol method, obtaining particle size and microstrain equal to 20 nm and 0.32, respectively. These ferroelectric nanoparticles were added into the natural rubber in concentrations equal to 1, 3, 5, 10, 20 and 50 phr (parts per hundred of rubber) forming ferroelectric nanocomposites (NR/KSN). Using morphological characterization, we identified the maximum value of surface roughness at low concentrations, in particular, sample with 3 phr of nanoparticles and factors such as encapsulation and uniformity in the distribution of nanoparticles into the natural rubber matrix are investigated and discussed.
Resumo:
The Frequency Modulated - Atomic Force Microscope (FM-AFM) is apowerful tool to perform surface investigation with true atomic resolution. The controlsystem of the FM-AFM must keep constant both the frequency and amplitude ofoscillation of the microcantilever during the scanning process of the sample. However,tip and sample interaction forces cause modulations in the microcantilever motion.A Phase-Locked Loop (PLL) is used as a demodulator and to generate feedback signalto the FM-AFM control system. The PLL performance is vital to the FM-AFMperformace since the image information is in the modulated microcantilever motion.Nevertheless, little attention is drawn to PLL performance in the FM-AFM literature.Here, the FM-AFM control system is simulated, comparing the performancefor di erent PLL designs.
Resumo:
In this work, the synthetic hydroxyapatite (HAP) was studied using different preparation routes to decrease the crystal size and to study the temperature effect on the HAP nano-sized hydroxyapatite crystallization. X-ray diffraction (XRD) analysis indicated that all samples were composed by crystalline and amorphous phases . The sample with greater quantity of amorphous phase (40% of total mass) was studied. The nano-sized hydroxyapatite powder was heated and studied at 300, 500, 700, 900 and 1150 °C. All samples were characterized by XRD and their XRD patterns refined using the Rietveld method. The crystallites presented an anisotropic form, being larger in the [001] direction. It was observed that the crystallite size increased continuously with the heating temperature and the eccentricity of the ellipsoidal shape changed from 2.75 at 300 °C to 1.94, 1.43, 1.04 and 1.00 respectively at 500, 700, 900 and 1150 °C. In order to better characterize the morphology of the HAP the samples were also examined using atomic force microscopy (AFM), infrared spectrometry (IR) and thermogravimetric analysis (TGA).
Resumo:
The effect of CO2 continuous laser irradiation on the surface properties of veneering porcelains has already been tested. The surface observed after laser irradiation is similar to that achieved by auto-glaze in terms of roughness and color parameters (Sgura R, et al. Dental Materials 2011;27(Suppl. 1):e72–73). The purpose of this study was to analyze the surface porosity of porcelain discs after CO2 laser treatment and compare it to auto-glaze treatment, in furnace. A morphological analysis of the porcelain surface was conducted using atomic force microscopy (AFM) and conventional optical microscopy (OM).
Resumo:
In der vorliegenden Arbeit wurden AFM-Kraft-Abstands-Kurven benutzt, um die mechanischen Eigenschaften dünner Polymerfilme verschiedener Schichtdicken (2 - 400 nm) auf einem sehr viel steiferen Substrat (mechanische Doppelschichten) zu untersuchen. Die mechanischen Eigenschaften einer solchen Probe setzen sich aus den mechanischen Eigenschaften der Bestandteile, d.h. Polymer und Substrat, zusammen. Der Beitrag der Bestandteile hängt von der Schichtdicke und von der Auflagekraft ab. Es wurden existierende Modelle für die Auswertung von an Doppelschichten gemessenen Deformationskurven überprüft und festgestellt, dass kein Modell befriedigende Ergebnisse erzielt. Dies zeigte die Notwendigkeit einer neuen semiempirischen Theorie zur Beschreibung der Deformationskurven von mechanischen Doppelschichten. In dieser Arbeit wird der hyperbolische Fit zu diesem Zweck eingeführt. Die Validität des hyperbolischen Fit wurde anhand von drei Experimenten gezeigt. Alle experimentellen Kurven konnten sehr gut durch den hyperbolischen Fit beschrieben werden. Die Elastizitätsmoduln der Bestandteile konnten in Übereinstimmung mit den Literaturwerten berechnet werden. Die Schichtdicken der Proben konnten in allen Fällen mit großer Exaktheit bestimmt werden. Es wurde zudem die Möglichkeit der Auswertung einzelner Kraft-Abstands-Kurven untersucht. Damit konnte die Schichtdicke der untersuchten Doppelschichten ortsaufgelöst im Submikrometerbereich bestimmt werden und ein verstecktes Substrat detektiert werden. Die Adhäsion an der Grenzfläche Polymer/Substrat hat einen fundamentalen Einfluss auf die mechanischen Eigenschaften der Doppelschicht, der qualitativ im letzten Teil der Doktorarbeit gezeigt werden konnte.
Resumo:
Le malattie neurodegenerative sono caratterizzate da aggregazione proteica, dipendente dalla perdita della usuale struttura fisiologica funzionale delle proteine coinvolte, a favore di conformazioni tossiche (patologiche). Il modello corrente descrive questi cambiamenti conformazionali come eventi rari e ritiene che non esista una sola conformazione patogena, ma che tali possibili conformazioni siano piuttosto eterogenee. La caratterizzazione di queste strutture è, di conseguenza, difficile con le tradizionali tecniche in bulk che permettono di studiare solo la conformazione media e non rendono possibile il riconoscimento delle caratteristiche dei conformeri individuali. Lo sviluppo delle tecniche di singola molecola ha permesso di studiare in modo approfondito le conformazioni possibili. In questo lavoro la spettroscopia di forza di singola molecola basata sull'AFM viene applicata a PrP (proteina responsabile delle encefalopatie spongiformi trasmissibili). Si studiano gli equilibri conformazionali del monomero e quelli di costrutti oligomerici, allo scopo di caratterizzare gli step iniziali dei processi aggregativi. Nel corso di questo lavoro di tesi è stato, in particolare, sviluppato un sistema di analisi dati, al fine di studiare in modo quantitativo le distribuzioni di eventi ottenute. Grazie a tale strumento è stato possibile riconoscere i segnali di unfolding della conformazione nativa del monomero e notare come essa sia presente anche in costrutti oligomerici, ad indicare come questo ripiegamento sia stabile anche in presenza di più monomeri ravvicinati. Si è osservato l'effetto del pH sulla stabilità di tale struttura, notando come pH acidi destabilizzino il ripiegamento nativo. Inoltre si è studiato il ruolo dell'orientazione dei monomeri nella formazione di strutture dimeriche. Monomeri e oligomeri di PrP sono stati descritti come proteine parzialmente strutturate il cui panorama energetico contiene molti minimi locali, dando origine a parecchie conformazioni transienti.
Resumo:
We demonstrate a reliable microfabrication process for a combined atomic force microscopy (AFM) and scanning electrochemical microscopy (SECM) measurement tool. Integrated cone-shaped sensors with boron doped diamond (BDD) or gold (Au) electrodes were fabricated from commercially available AFM probes. The sensor formation process is based on mature semiconductor processing techniques, including focused ion beam (FIB) machining, and highly selective reactive ion etching (RIE). The fabrication approach preserves the geometry of the original AFM tips resulting in well reproducible nanoscaled sensors. The feasibility and functionality of the fully featured tips are demonstrated by cyclic voltammetry, showing good agreement between the measured and calculated currents of the cone-shaped AFM-SECM electrodes.