999 resultados para Acoustic Impact
Resumo:
Objectives: We compare the dose parameters between 3 different radiosurgery delivery techniques which may have an impact on cochlea function. Methods: Five patients with unilateral vestibular schwannoma (VS) were selected for this study. Planning procedure was carried out using the BrainLAB® iPlan planning system v. 4.5. For each patient three different planning techniques were used: dynamic arc (DA) with 5 arcs per plan, hybrid arc (HA) with 5 arcs per plan and IMRT with 8 fields per plan. For each technique, two plans were generated with different methods: with the first method (PTV coverage) it was the goal to fully cover the PTV with at least 12 Gy (normalization: 12 Gy covered 99% of the PTV) and with the second method (cochlea sparing) it was the goal to spare the cochlea (normalization: 12 Gy covers 50% of the PTV/V4Gy of cochlea lower than 1%). Plan evaluation was done considering target volume and coverage (conformity and homogeneity) and OAR constraints (mean (Dmean) and maximum dose (Dmax) to cochlea, Dmax to brainstem and cochlea). The total number of monitor units (MU) was analyzed. Results: The median tumor volume was 0.95 cm³ (range, 0.86-3 cm³). The median PTV was 1.44 cm³ (range, 1-3.5 cm³). The median distance between the tumor and the cochlea's modiulus was 2.7 mm (range, 1.8-6.3 mm). For the PTV coverage method, when we compared the cochlear dose in VS patients planned with DA, HA and IMRT, there were no significant differences in Dmax (p = 0.872) and in Dmean (p= 0.860). We found a significant correlation (p< 0.05) between the target volume and the cochlear Dmean for all plans with Pearson's coefficient correlation of 0.90, 0.92 and 0.94 for the DA, HA and IMRT techniques, respectively. For the cochlea sparing method, when we compared the cochlear dose in VS patients planned with DA, HA and IMRT, there were no significant differences in Dmax (p = 0.310) and in Dmean (p= 0.275). However, in this group the V4Gy of the ipsilateral cochlea represents less than 1%. When using the HA or IMRT technique, the homogeneity and conformity in the PTV, but also the number of MUs were increased in comparison to the DA technique. Conclusion: VS tumors that extend distally into the IAC had an equivalent sparing of cochlea with DA approach compared with the HA and IMRT techniques. Disclosure: No significant relationships.
Resumo:
La Directiva 2003/10/CE del Parlamento Europeo y del Consejo, del 6 de febrero de 2003, específica con arreglo al apartado 1 del artículo 16 de la Directiva 89/391/CEE las disposiciones mínimas de seguridad y de salud relativas a la exposición de los trabajadores a los riesgos derivados de los agentes físicos (ruido). En la industria musical, y en concreto en los músicos de orquesta, una exposición de más de ocho horas al día a un nivel de presión sonora de 80dB(A) o más es algo muy común. Esta situación puede causar a los trabajadores daños auditivos como la hiperacusia, hipoacusia, tinitus o ruptura de la membrana basilar entre otros. Esto significa que deben tomarse medidas para implementar las regulaciones de la forma más razonable posible para que la interpretación del músico, la dinámica y el concepto musical que se quiere transmitir al público se vea lo menos afectada posible. Para reducir la carga auditiva de los músicos de orquesta frente a fuertes impactos sonoros provenientes de los instrumentos vecinos, se está investigando sobre el uso de unos paneles acústicos que colocados en puntos estratégicos de la orquesta pueden llegar a reducir el impacto sonoro sobre el oído hasta 20dB. Los instrumentos de viento metal y de percusión son los responsables de la mayor emisión de presión sonora. Para proteger el oído de los músicos frente a estos impactos, se colocan los paneles en forma de barrera entre dichos instrumentos y los músicos colocados frente a ellos. De esta forma se protege el oído de los músicos más afectados. Para ver el efecto práctico que producen estos paneles en un conjunto orquestal, se realizan varias grabaciones en los ensayos y conciertos de varias orquestas. Los micrófonos se sitúan a la altura del oído y a una distancia de no más de 10cm de la oreja de varios de los músicos más afectados y de los músicos responsables de la fuerte emisión sonora. De este modo se puede hacer una comparación de los niveles de presión sonora que percibe cada músico y evaluar las diferencias de nivel existentes entre ambos. Así mismo se utilizan configuraciones variables de los paneles para comparar las diferencias de presión sonora que existen entre las distintas posibilidades de colocarlos y decidir así sobre la mejor ubicación y configuración de los mismos. A continuación, una vez obtenidos las muestras de audio y los diferentes archivos de datos medidos con un analizador de audio en distintas posiciones de la orquesta, todo ello se calibra y analiza utilizando un programa desarrollado en Matlab, para evaluar el efecto de los paneles sobre la percepción auditiva de los músicos, haciendo especial hincapié en el análisis de las diferencias de nivel de presión sonora (SPL). Mediante el cálculo de la envolvente de las diferencias de nivel, se evalúa de un modo estadístico el efecto de atenuación de los paneles acústicos en los músicos de orquesta. El método está basado en la probabilidad estadística de varias muestras musicales ya que al tratarse de música tocada en directo, la dinámica y la sincronización entre los músicos varía según el momento en que se toque. Estos factores junto con el hecho de que la partitura de cada músico es diferente dificulta la comparación entre dos señales grabadas en diferentes puntos de la orquesta. Se necesita por lo tanto de varias muestras musicales para evaluar el efecto de atenuación de los paneles en las distintas configuraciones mencionadas anteriormente. El estudio completo del efecto de los paneles como entorno que influye en los músicos de orquesta cuando están sobre el escenario, tiene como objetivo la mejora de sus condiciones de trabajo. Abstract For several years, the European Union has been adopting many laws and regulations to protect and give more security to people who are exposed to some risk in their job. Being exposed to a loud sound pressure level during many hours in the job runs the risk of hearing damage. Particularly in the field of music, the ear is the most important working tool. Not taking care of the ear can cause some damage such as hearing loss, tinnitus, hyperacusis, diplacusis, etc. This could have an impact on the efficiency and satisfaction of the musicians when they are playing, which could also cause stress problems. Orchestra musicians, as many other workers in this sector, are usually exposed to a sound level of 80dB(A) or more during more than eight hours per day. It means that they must satisfy the law and their legal obligations to avoid health problems proceeding from their job. Putting into practice the new regulations is a challenge for orchestras. They must make sure that the repertoire, with its dynamic, balance and feeling, is not affected by the reduction of sound levels imposed by the law. This study tries to investigate the benefits and disadvantages of using shields as a hearing protector during rehearsals and orchestral concerts.
Resumo:
This work describes an acoustic system that allows the automatic detection and location of mechanical impacts on metallic based structures, which is suitable in robotics and industrial applications. The system is based on the time delays of propagation of the acoustic waves along the metallic based structure and it determines the instant and the position when and were the impact has been produced by piezoelectric sensors and an electronic-computerized system. We have obtained that for distance impact of 40 cm and 50 cm the time delay is 2 s and 72 s respectively.
Resumo:
In the last years, many analyses from acoustic signal processing have been used for different applications. In most cases, these sensor systems are based on the determination of times of flight for signals from every transducer. This paper presents a flat plate generalization method for impact detection and location over linear links or bars-based structures. The use of three piezoelectric sensors allow to achieve the position and impact time while the use of additional sensors lets cover a larger area of detection and avoid wrong timing difference measurements. An experimental setup and some experimental results are briefly presented.
Resumo:
The impact noise reduction provided by floor coverings is usually obtained in laboratory, using the methodology described in the standard EN ISO 140-8, which requires the use of standard acoustic chambers. The construction of such chambers, following the requirements described in the EN ISO 140-1, implies a significant investment, and therefore only a limited number exists in each country. Alternatives to these standard methodologies, that allow a sufficiently accurate evaluation and require lower resources, have been interesting many researchers and manufacturers. In this paper, one such strategy is discussed, where a reduced sized slab is used to determine the noise reduction provided by floor coverings, following the procedure described in the ISO/CD 16251-1 technical document. Several resilient coverings, floating floors and floating slabs are tested and the results are compared with those obtained using the procedures described in the standards EN ISO 140-8 and EN ISO 717-2.
Resumo:
Articulatory imprecision has been documented as a key perceptual feature of the dysarthria associated with childhood cerebellar tumor (CCT). As yet the underlying acoustic and physiological characteristics of motor speech production that contribute to this perceptual feature have not been identified. The aim of the current study was to describe perceptual and acoustic characteristics of consonant production in three children with dysarthria associated with CCT The results indicated that in all three cases the timing of articulatory movements during stop consonant production differed from that measured in a control group of same-age peers. The impact of cerebellar lesions in adulthood on articulatory gestures is used as a reference for discussing the findings of the current study with similarities evident. Also discussed are future research directions for examining the underlying acoustic or physiological basis for articulatory imprecision in children with dysarthria associated with CCT.
Resumo:
There is growing evidence that 1,25-dihydroxyvitamin D-3 is involved in normal brain development. The aim of this study was to examine the impact of prenatal and postnatal hypovitaminosis D on prepulse inhibition (PPI) of acoustic startle in adult rats. We compared six groups of rats: control rats with normal vitamin D throughout life and normal litter size (Litter); control rats with normal vitamin D but with a reduced litter size of two (Control); offspring from reduced litters of vitamin D deplete mothers who were repleted at birth (Birth), repleted at weaning (Weaning) or remained on a deplete diet until 10 weeks of age (Life); or control rats that were placed on a vitamin D-deficient diet from 5 to 10 weeks of age (Adult). All rats were tested in acoustic startle chambers at 5 and 10 weeks of age for acoustic startle responses and for PPI. There were no significant group differences at 5 weeks of age on the acoustic startle response or on PPI. At 10 weeks of age, rats in the Life group only had impaired PPI despite having normal acoustic startle responses. We conclude that combined prenatal and chronic postnatal hypovitaminosis D, but not early life hypovitaminosis D, alters PPI. (C) 2004 Elsevier Inc. All rights reserved.
Resumo:
This thesis considers two basic aspects of impact damage in composite materials, namely damage severity discrimination and impact damage location by using Acoustic Emissions (AE) and Artificial Neural Networks (ANNs). The experimental work embodies a study of such factors as the application of AE as Non-destructive Damage Testing (NDT), and the evaluation of ANNs modelling. ANNs, however, played an important role in modelling implementation. In the first aspect of the study, different impact energies were used to produce different level of damage in two composite materials (T300/914 and T800/5245). The impacts were detected by their acoustic emissions (AE). The AE waveform signals were analysed and modelled using a Back Propagation (BP) neural network model. The Mean Square Error (MSE) from the output was then used as a damage indicator in the damage severity discrimination study. To evaluate the ANN model, a comparison was made of the correlation coefficients of different parameters, such as MSE, AE energy, AE counts, etc. MSE produced an outstanding result based on the best performance of correlation. In the second aspect, a new artificial neural network model was developed to provide impact damage location on a quasi-isotropic composite panel. It was successfully trained to locate impact sites by correlating the relationship between arriving time differences of AE signals at transducers located on the panel and the impact site coordinates. The performance of the ANN model, which was evaluated by calculating the distance deviation between model output and real location coordinates, supports the application of ANN as an impact damage location identifier. In the study, the accuracy of location prediction decreased when approaching the central area of the panel. Further investigation indicated that this is due to the small arrival time differences, which defect the performance of ANN prediction. This research suggested increasing the number of processing neurons in the ANNs as a practical solution.
Resumo:
An important aspect of speech perception is the ability to group or select formants using cues in the acoustic source characteristics-for example, fundamental frequency (F0) differences between formants promote their segregation. This study explored the role of more radical differences in source characteristics. Three-formant (F1+F2+F3) synthetic speech analogues were derived from natural sentences. In Experiment 1, F1+F3 were generated by passing a harmonic glottal source (F0 = 140 Hz) through second-order resonators (H1+H3); in Experiment 2, F1+F3 were tonal (sine-wave) analogues (T1+T3). F2 could take either form (H2 or T2). In some conditions, the target formants were presented alone, either monaurally or dichotically (left ear = F1+F3; right ear = F2). In others, they were accompanied by a competitor for F2 (F1+F2C+F3; F2), which listeners must reject to optimize recognition. Competitors (H2C or T2C) were created using the time-reversed frequency and amplitude contours of F2. Dichotic presentation of F2 and F2C ensured that the impact of the competitor arose primarily through informational masking. In the absence of F2C, the effect of a source mismatch between F1+F3 and F2 was relatively modest. When F2C was present, intelligibility was lowest when F2 was tonal and F2C was harmonic, irrespective of which type matched F1+F3. This finding suggests that source type and context, rather than similarity, govern the phonetic contribution of a formant. It is proposed that wideband harmonic analogues are more effective informational maskers than narrowband tonal analogues, and so become dominant in across-frequency integration of phonetic information when placed in competition.
Resumo:
Two Polarstern expeditions were conducted in 1995 (ANT-XII/4) and 2001 (ANT-XVIII/5a) to the Bellingshausen Sea and Amundsen Sea and the suspected Eltanin meteorite impact in the SE-Pacific. A survey of the sediment distribution and its acoustic structure along the cruise track was performed. The seafloor topography was sampled using the multibeam sonar system Hydrosweep DS2 which operates on a frequency of 15.5 kHz. The resulting AWI Bathymetric Chart of the Eltanin Meteorite Impact Area is based on a Digital Terrain Model of this area. The mapping was performed using ArcGIS. The Eltanin impact area which covers the 4.100 m high Freden Seamount is visualized by one overview sheet of the scale 1:200,000 and four 1:100,000 subsheets.
Resumo:
The role of source properties in across-formant integration was explored using three-formant (F1+F2+F3) analogues of natural sentences (targets). In experiment 1, F1+F3 were harmonic analogues (H1+H3) generated using a monotonous buzz source and second-order resonators; in experiment 2, F1+F3 were tonal analogues (T1+T3). F2 could take either form (H2 or T2). Target formants were always presented monaurally; the receiving ear was assigned randomly on each trial. In some conditions, only the target was present; in others, a competitor for F2 (F2C) was presented contralaterally. Buzz-excited or tonal competitors were created using the time-reversed frequency and amplitude contours of F2. Listeners must reject F2C to optimize keyword recognition. Whether or not a competitor was present, there was no effect of source mismatch between F1+F3 and F2. The impact of adding F2C was modest when it was tonal but large when it was harmonic, irrespective of whether F2C matched F1+F3. This pattern was maintained when harmonic and tonal counterparts were loudness-matched (experiment 3). Source type and competition, rather than acoustic similarity, governed the phonetic contribution of a formant. Contrary to earlier research using dichotic targets, requiring across-ear integration to optimize intelligibility, H2C was an equally effective informational masker for H2 as for T2.
Resumo:
Hemp-lime concrete is a sustainable alternative to standard wall construction materials. It boasts excellent hygrothermal properties in part deriving from its porous structure. This paper investigates the acoustic properties of hemp-lime concrete, using binders developed from hydrated lime and pozzolans as well as hydraulic and cementicious binders. To assess the acoustic absorption of hemp-lime walls, as they are commonly finished in practical construction, wall sections are rendered and the resulting impact on absorption is evaluated. Hemp-concretes with lime-pozzolan binders display superior acoustic properties relative to more hydraulic binders. These are diminished when rendered, as the open surface porosity is affected, however hemp-lime construction offers the potential to meet standard and guideline targets for spaces requiring acoustic treatment.
Resumo:
Opto-acoustic imaging is a growing field of research in recent years, providing functional imaging of physiological biomarkers, such as the oxygenation of haemoglobin. Piezo electric transducers are the industry standard detector for ultrasonics, but their limited bandwidth, susceptibility to electromagnetic interference and their inversely proportional sensitivity to size all affect the detector performance. Sensors based on polymer optical fibres (POF) are immune to electromagnetic interference, have lower acoustic impedance and a reduced Young's Modulus compared to silica fibres. Furthermore, POF enables the possibility of a wideband sensor and a size appropriate to endoscopy. Micro-structured POF (mPOF) used in an interferometric detector has been shown to be an order of magnitude more sensitive than silica fibre at 1 MHz and 3 times more sensitive at 10 MHz. We present the first opto-acoustic measurements obtained using a 4.7mm PMMA mPOF Bragg grating with a fibre diameter of 130 μm and present the lateral directivity pattern of a PMMA mPOF FBG ultrasound sensor over a frequency range of 1-50 MHz. We discuss the impact of the pattern with respect to the targeted application and draw conclusions on how to mitigate the problems encountered.
Resumo:
The cerebellum is an important site for cortical demyelination in multiple sclerosis, but the functional significance of this finding is not fully understood. To evaluate the clinical and cognitive impact of cerebellar grey-matter pathology in multiple sclerosis patients. Forty-two relapsing-remitting multiple sclerosis patients and 30 controls underwent clinical assessment including the Multiple Sclerosis Functional Composite, Expanded Disability Status Scale (EDSS) and cerebellar functional system (FS) score, and cognitive evaluation, including the Paced Auditory Serial Addition Test (PASAT) and the Symbol-Digit Modalities Test (SDMT). Magnetic resonance imaging was performed with a 3T scanner and variables of interest were: brain white-matter and cortical lesion load, cerebellar intracortical and leukocortical lesion volumes, and brain cortical and cerebellar white-matter and grey-matter volumes. After multivariate analysis high burden of cerebellar intracortical lesions was the only predictor for the EDSS (p<0.001), cerebellar FS (p = 0.002), arm function (p = 0.049), and for leg function (p<0.001). Patients with high burden of cerebellar leukocortical lesions had lower PASAT scores (p = 0.013), while patients with greater volumes of cerebellar intracortical lesions had worse SDMT scores (p = 0.015). Cerebellar grey-matter pathology is widely present and contributes to clinical dysfunction in relapsing-remitting multiple sclerosis patients, independently of brain grey-matter damage.
Resumo:
Background. Benign prostatic hyperplasia (BPH) pharmacological treatment may promote a decrease in prostate vascularization and bladder neck relaxation with theoretical improvement in prostate biopsy morbidity, though never explored in the literature. Methods. Among 242 consecutive unselected patients who underwent prostate biopsy, after excluding those with history of prostate biopsy/surgery or using medications not for BPH, we studied 190 patients. On the 15th day after procedure patients were questioned about symptoms lasting over a week and classified according to pharmacological BPH treatment. Results. Thirty-three patients (17%) were using alpha-blocker exclusively, five (3%) 5-alpha-reductase inhibitor exclusively, twelve (6%) patients used both medications, and 140 (74%) patients used none. There was no difference in regard to age among groups (P = 0.5). Postbiopsy adverse effects occurred as follows: hematuria 96 (50%), hematospermia 53 (28%), hematochezia 22 (12%), urethrorrhagia 19 (10%), fever 5 (3%), and pain 20 (10%). There was a significant negative correlation between postbiopsy hematuria and BPH pharmacological treatment with stronger correlation for combined use of 5-alpha-reductase inhibitor and alpha-blocker over 6 months (P = 0.0027). Conclusion. BPH pharmacological treatment, mainly combined for at least 6 months seems to protect against prostate biopsy adverse effects. Future studies are necessary to confirm our novel results.