222 resultados para 99mTc-sestamibi
Exercise may cause myocardial ischemia at the anaerobic threshold in cardiac rehabilitation programs
Resumo:
Myocardial ischemia may occur during an exercise session in cardiac rehabilitation programs. However, it has not been established whether it is elicited when exercise prescription is based on heart rate corresponding to the anaerobic threshold as measured by cardiopulmonary exercise testing. Our objective was to determine the incidence of myocardial ischemia in cardiac rehabilitation programs according to myocardial perfusion SPECT in exercise programs based on the anaerobic threshold. Thirty-nine patients (35 men and 4 women) diagnosed with coronary artery disease by coronary angiography and stress technetium-99m-sestamibi gated SPECT associated with a baseline cardiopulmonary exercise test were assessed. Ages ranged from 45 to 75 years. A second cardiopulmonary exercise test determined training intensity at the anaerobic threshold. Repeat gated-SPECT was obtained after a third cardiopulmonary exercise test at the prescribed workload and heart rate. Myocardial perfusion images were analyzed using a score system of 6.4 at rest, 13.9 at peak stress, and 10.7 during the prescribed exercise (P < 0.05). The presence of myocardial ischemia during exercise was defined as a difference ≥2 between the summed stress score and summed rest score. Accordingly, 25 (64%) patients were classified as ischemic and 14 (36%) as nonischemic. MIBI-SPECT showed myocardial ischemia during exercise within the anaerobic threshold. The 64% prevalence of ischemia observed in the study should not be looked on as representative of the whole population of patients undergoing exercise programs. Changes in patient care and exercise programs were implemented as a result of our finding of ischemia during the prescribed exercise.
Resumo:
La cirugía radioguiada es una rama de la medicina nuclear con la cual se marca el tejido tumoral con un radiotrazador (MIBI) y mediante el uso de una gamasonda o gamacámara poder diferenciarlo del tejido cerebral sano in vivo en la sala de cirugía. Esta técnica se ha aplicado con éxito en tumores del SNC (Gliomas de alto grado, metástasis, meningiomas). Los tumores del SNC representan el 1% de todos los tumores pero son la tercera causa de mortalidad por cáncer en el mundo. Hay un mejor pronóstico de los pacientes con mayor extensión de la resección. Objetivos: Evaluar la factibilidad de la técnica y optimizar los procesos en el INC con la finalidad de desarrollar un protocolo de línea de investigación en esta materia. Materiales y métodos: se realiza un reporte de casos de pacientes con diagnóstico de tumor cerebral supratentorial. Se realizó SPECT cerebral con MIBI para confirmar captación del radiotrazador. En los pacientes que marcaron positivo se programó cirugía radioguiada con gamacámara portátil Sentinel Resultados: En 5 pacientes con tumores supratentoriales se realizó SPECT cerebral con MIBI: 3 de ellos fueron positivos los cuales fueron programados para cirugía radioguiada y los 2 restantes con cirugía convencional. Dos de los casos positivos correspondieron a Tumor de alto grado y un caso de tumor abscedado. En quienes se practicó la cirugía radioguiada se consiguió resección tumoral completa tumoral por imagen de gamacámara intraquirúrgica
Resumo:
Pós-graduação em Ginecologia, Obstetrícia e Mastologia - FMB
Resumo:
ZusammenfassungrnDie häufigsten Todesfälle weltweit sind auf Herzerkrankungen zurückzuführen. Bei der koronaren Herzkrankheit (KHK) sammeln sich über Jahre arteriosklerotische Ablagerungen in den Herzkranzgefäßen an und führen so zu einer verminderten Durchblutung und Versorgung des Herzmuskelgewebes mit Sauerstoff und Nährstoffen. Zur nuklearmedizinischen Bildgebung finden am häufigsten das SPECT-Nuklid 201Tl sowie die beiden 99mTc-Radiopharmaka Sestamibi und Tetrofosmin Anwendung. Die PET-Technik ist der SPECT-Technik in Bezug auf absolute Quantifizierung sowie Auflösung überlegen. Ziel der vorliegenden Arbeit war es, ein mögliches PET-Radiopharmakon zur Diagnostik der KHK zu entwickeln. Um eine dem 99mTc-Nuklid vergleichbare Verfügbarkeit im klinischen Alltag zu erreichen, sollte als Basis des neuen Radiopharmakons das mittels Radionuklid-Generator verfügbare 68Ga dienen. Schiff’sche Basen-Verbindungen zeigten nach Komplexierung mit 67/68Ga eine deutliche Aufnahme in die Herzmuskelzellen. Auf dieser Grundlage wurden verschiedene Schiff’sche Basen-Strukturen synthetisiert. Diese unterscheiden sich einerseits durch das Substitutionsmuster der verwendeten Aldehyde und andererseits durch das verwendete Rückgrat. Alle synthetisierten Chelatoren wurden erfolgreich mit 68Ga radioaktiv markiert und konnten anschließend aufgereinigt werden. Die Evaluierung dieser Substanzen in vitro zeigte, dass sie in unterschiedlichen Medien stabil ist. Die Lipophilie der 68Ga-Verbindungen (log D) lag zwischen 0,87±0,24 und 2,72±0,14. Die Ladung der Verbindungen wurde mittels Papierelektrophorese bei pH= 7 als kationisch bestimmt. Zusätzlich fanden in vitro-Untersuchungen zur Bestimmung der Aufnahme der Komplexe in HL-1 Herzzellen statt. Um den Einfluss des Zellmembranpotentials bzw. des Mitochondrienmembranpotentials zu untersuchen, wurde ein Teil der Zellen dafür mit Valinomycin (Ionophor, zerstört das Potential) behandelt. Mittels ex vivo-Biodistributionen wurde die Organverteilung von zwei Schiff’schen Basen (68Ga-BADED-2 und 68Ga-BAPDMEN-2) mit dem routinemäßig in der Klinik eingesetzten Derivat 99mTc-Sestamibi sowie dem 18F-Flurpiridaz in Ratten verglichen. Alle Verbindungen zeigten dabei eine deutliche Herzaufnahme von mehr als 2 % der injizierten Dosis pro Gramm Gewebe. Durch in vivo-PET-Aufnahmen wurden die Zeit-Aktivitätskurven der 68Ga-Verbindungen sowie zum Vergleich des 18F-Flurpiridaz bestimmt. Die Aufnahmen lagen im Bereich von 0,63±0,15 für 68Ga-BAPEN-3 bis 2,72±0,86 für 68Ga-BADED-8.In dem zweiten Teil der Arbeit wurden die Vorteile des hochaffinen Herztracers Flurpiridaz mit dem lipophilen, positiv-geladenen Ga-Schiff’sche Base-Chelator kombiniert. Hierzu wurde zunächst das Insektizid Flurpiridaz synthetisiert und mit dem BAPEN-Rückgrat gekoppelt. Die entstandene Verbindung wurde erstmals mit 68Ga radioaktiv markiert und muss in weiterführenden Arbeiten evaluiert werden.
Resumo:
Herz-Kreislauf-Erkrankungen zählen weltweit zu den Hauptursachen, die zu frühzeitigem Tod führen. Pathophysiologisch liegt eine Gefäßwandverdickung durch Ablagerung arteriosklerotischer Plaques (Arteriosklerose) vor. Die molekulare Bildgebung mit den nuklearmedizinischen Verfahren SPECT und PET zielt darauf ab, minderperfundierte Myokardareale zu visualisieren, um den Krankheitsverlauf durch frühzeitige Therapie abschwächen zu können. Routinemäßig eingesetzt werden die SPECT-Perfusionstracer [99mTc]Sestamibi und [99mTc]Tetrofosmin. Zum Goldstandard für die Quantifizierung der Myokardperfusion werden allerdings die PET-Tracer [13N]NH3 und [15O]H2O, da eine absolute Bestimmung des Blutflusses in mL/min/g sowohl in der Ruhe als auch bei Belastung möglich ist. 2007 wurde [18F]Flurpiridaz als neuer Myokardtracer vorgestellt, dessen Bindung an den MC I sowohl in Ratten, Hasen, Primaten als auch in ersten klinischen Humanstudien eine selektive Myokardaufnahme zeigte. Um eine Verfügbarkeit des Radionuklids über einen Radionuklidgenerator gewährleisten zu können, sollten makrozyklische 68Ga-Myokard-Perfusionstracer auf Pyridaben-Basis synthetisiert und evaluiert werden. Die neue Tracer-Klasse setzte sich aus dem makrozyklischen Chelator, einem Linker und dem Insektizid Pyridaben als Targeting-Vektor zusammen. Struktur-Affinitätsbeziehungen konnten auf Grund von Variation des Linkers (Länge und Polarität), der Komplexladung (neutral und einfach positiv geladen), des Chelators (DOTA, NODAGA, DO2A) sowie durch einen Multivalenzansatz (Monomer und Dimer) aufgestellt werden. Insgesamt wurden 16 neue Verbindungen synthetisiert. Ihre 68Ga-Markierung wurde hinsichtlich pH-Wert, Temperatur, Vorläufermenge und Reaktionszeit optimiert. Die DOTA/NODAGA-Pyridaben-Derivate ließen sich mit niedrigen Substanzmengen (6 - 25 nmol) in 0,1 M HEPES-Puffer (pH 3,4) bei 95°C innerhalb 15 min mit Ausbeuten > 95 % markieren. Für die DO2A-basierenden Verbindungen bedurfte es einer mikrowellengestützen Markierung (300 W, 1 min, 150°C), um vergleichbare Ausbeuten zu erzielen. Die in vitro-Stabilitätstests aller Verbindungen erfolgten in EtOH, NaCl und humanem Serum. Es konnten keine Instabilitäten innerhalb 80 min bei 37°C festgestellt werden. Unter Verwendung der „shake flask“-Methode wurden die Lipophilien (log D = -1,90 – 1,91) anhand des Verteilungs-quotienten in Octanol/PBS-Puffer ermittelt. Die kalten Referenzsubstanzen wurden mit GaCl3 hergestellt und zur Bestimmung der IC50-Werte (34,1 µM – 1 µM) in vitro auf ihre Affinität zum MC I getestet. In vivo-Evaluierungen erfolgten mit den zwei potentesten Verbindungen [68Ga]VN160.MZ und [68Ga]VN167.MZ durch µ-PET-Aufnahmen (n=3) in gesunden Ratten über 60 min. Um die Organverteilung ermitteln zu können, wurden ex vivo-Biodistributionsstudien (n=3) vorgenommen. Sowohl die µ-PET-Untersuchungen als auch die Biodistributionsstudien zeigten, dass es bei [68Ga]VN167.MZ zwar zu einer Herzaufnahme kam, die jedoch eher perfusionsabhängig ist. Eine Retention des Tracers im Myokard konnte in geringem Umfang festgestellt werden.
Resumo:
BACKGROUND: Left anterior hemiblock (LAHB) is the most frequent conduction abnormality, but its impact on the diagnostic accuracy of the exercise ECG has not been studied. The aim of our study was to determine the diagnostic accuracy of ST depression for predicting ischaemia in the presence of LAHB. PATIENTS: Consecutive patients with known or suspected coronary heart disease undergoing exercise ECG and 99mTc-sestamibi single photon emission computed tomography (SPECT) were included in the analysis. Patients with left bundle branch block, with changes in QRS morphology related to myocardial infarction, and patients who had undergone pharmacological stress testing were excluded. RESULTS: Of 1532 patients assessed, 567 patients qualified for the analysis. In 69 patients with LAHB, ECG stress testing had lower sensitivity (38% vs 86%) and lower negative predictive value (82% vs 92%) than in patients with normal baseline ECG. The reduction of sensitivity appeared to be similar in patients with isolated LAHB (n=43), in patients with right bundle branch block (n=39), and with bifascicular block (n=26). In contrast, the positive predictive value of the test was excellent. CONCLUSION: The diagnostic accuracy of the exercise ECG for prediction of ischaemia is reduced in patients with LAHB.
Resumo:
The blood–brain barrier and a blood–cerebrospinal-fluid (CSF) barrier function together to isolate the brain from circulating drugs, toxins, and xenobiotics. The blood–CSF drug-permeability barrier is localized to the epithelium of the choroid plexus (CP). However, the molecular mechanisms regulating drug permeability across the CP epithelium are defined poorly. Herein, we describe a drug-permeability barrier in human and rodent CP mediated by epithelial-specific expression of the MDR1 (multidrug resistance) P glycoprotein (Pgp) and the multidrug resistance-associated protein (MRP). Noninvasive single-photon-emission computed tomography with 99mTc-sestamibi, a membrane-permeant radiopharmaceutical whose transport is mediated by both Pgp and MRP, shows a large blood-to-CSF concentration gradient across intact CP epithelium in humans in vivo. In rats, pharmacokinetic analysis with 99mTc-sestamibi determined the concentration gradient to be greater than 100-fold. In membrane fractions of isolated native CP from rat, mouse, and human, the 170-kDa Pgp and 190-kDa MRP are identified readily. Furthermore, the murine proteins are absent in CP isolated from their respective mdr1a/1b(−/−) and mrp(−/−) gene knockout littermates. As determined by immunohistochemical and drug-transport analysis of native CP and polarized epithelial cell cultures derived from neonatal rat CP, Pgp localizes subapically, conferring an apical-to-basal transepithelial permeation barrier to radiolabeled drugs. Conversely, MRP localizes basolaterally, conferring an opposing basal-to-apical drug-permeation barrier. Together, these transporters may coordinate secretion and reabsorption of natural product substrates and therapeutic drugs, including chemotherapeutic agents, antipsychotics, and HIV protease inhibitors, into and out of the central nervous system.
Resumo:
INTRODUÇÃO: Tumores indutores de osteomalácia (TIOs) são raros, geralmente apresentam origem mesenquimal, têm produção excessiva de fosfatoninas sendo a mais comum o FGF23 (Fibroblast Growth Factor 23) que, em níveis elevados, provoca osteomalácia hipofosfatêmica. A cura dos TIOs envolve a remoção completa do tumor, o que torna essencial sua localização. OBJETIVOS: (1) caracterizar nove pacientes com TIO ao diagnóstico e avaliá-los evolutivamente em longo prazo; (2) avaliar a eficácia da cintilografia com Octreotida (Octreoscan®) e a da cintilografia de corpo inteiro com Mibi (MIBI) na detecção dos TIOs. MÉTODOS: O acompanhamento dos pacientes consistiu na avaliação clínica, na avaliação laboratorial com ênfase no metabolismo ósseo e na realização de exames de imagem para caracterização das deformidades esqueléticas. Para a localização dos TIOs, os pacientes foram submetidos a exames de Octreoscan®, MIBI, ressonância magnética (RM) e tomografia computadorizada (TC). RESULTADOS: O período de observação dos pacientes variou de dois a 25 anos. Ao diagnóstico, todos exibiam fraqueza muscular, dores ósseas e fraturas de fragilidade. Em relação à avaliação laboratorial, apresentavam: hipofosfatemia com taxa de reabsorção tubular de fosfato reduzida, fosfatase alcalina aumentada e níveis elevados de FGF23. O Octreoscan® permitiu a identificação dos TIOs nos nove pacientes e o MIBI possibilitou a localização dos TIOs em seis pacientes, sendo que ambos os exames foram concordantes entre si e com os exames topográficos (RM ou TC). Os achados histopatológicos das lesões dos nove pacientes confirmaram tratar-se de oito tumores mesenquimais fosfatúricos (PMTs) benignos e um PMT maligno. Após a primeira intervenção cirúrgica para a remoção dos TIOs, quatro pacientes encontram-se em remissão da doença e cinco evoluíram com persistência tumoral. Dos cinco, quatro foram reoperados e um aguarda nova cirurgia. Dos que foram reoperados, um paciente se mantém em remissão da doença, um foi a óbito por complicações clínicas, uma teve doença metastática e o último apresentou recidiva tumoral três anos após a segunda cirurgia. Deformidades ósseas graves foram observadas nos pacientes cujo diagnóstico e/ou tratamento clínico foram tardios. O tratamento da osteomalácia foi iniciado com fosfato e perdurou até a ressecção tumoral, tendo sido reintroduzido nos casos de persistência/recidiva tumoral. Quatro pacientes que fizerem uso regular desse medicamento por mais de seis anos evoluíram com hiperparatireoidismo terciário (HPT). CONCLUSÕES: O estudo revelou que tanto o Octreoscan® como o MIBI foram capazes de localizar os TIOs. Por isso, incentivamos a realização do MIBI nos locais onde o Octreoscan® não for disponível. Uma equipe experiente é indispensável para o sucesso cirúrgico visto que os tumores, embora benignos, costumam ser infiltrativos. Recomendamos o seguimento por tempo indeterminado em função do risco de recidiva tumoral. Assim como o FGF23, consideramos o fósforo um excelente marcador de remissão, persistência e recidiva dos TIOs. O diagnóstico e o tratamento precoce são fundamentais para a melhora dos sintomas podendo minimizar as deformidades esqueléticas e as sequelas ósseas. O uso prolongado do fosfato no tratamento da osteomalácia hipofosfatêmica foi associado ao desenvolvimento do HPT
Resumo:
Mestrado em Medicina Nuclear. Área de especialização: Radiofarmácia.
Resumo:
Introduction: The quantification of th e differential renal function in adults can be difficult due to many factors - on e of the se is the variances in kidney depth and the attenuation related with all the tissue s between the kidney and the camera. Some authors refer that t he lower attenuation i n p ediatric patients makes unnecessary the use of attenuation correction algorithms. This study will com pare the values of differential renal function obtained with and with out attenuation correction techniques . Material and Methods: Images from a group consisting of 15 individuals (aged 3 years +/ - 2) were used and two attenuation correction method s were applied – Tonnesen correction factors and the geometric mean method . The mean time of acquisition (time post 99m Tc - DMSA administration) was 3.5 hours +/ - 0.8h. Results: T he absence of any method of attenuation correction apparently seems to lead to consistent values that seem to correlate well with the ones obtained with the incorporation of methods of attenuation correction . The differences found between the values obtained with and without attenuation correction were not significant. Conclusion: T he decision of not doing any kind of attenuation correction method can apparently be justified by the minor differences verified on the relative kidney uptake values. Nevertheless, if it is recognized that there is a need for a really accurate value of the relative kidney uptake, then an attenuation correction method should be used.
Resumo:
GOAL: The manufacturing and distribution of strips of instant thin - layer chromatography with silica gel (ITLC - SG) (reference method) is currently discontinued so there is a need for an alternative method f or the determination of radiochemical purity (RCP) of 99m Tc - tetrofosmin. This study aims to compare five alternative methods proposed by the producer to determine the RCP of 99m Tc - tetrofosmin. METHODS: Nineteen vials of tetrofosmin were radiolabelled with 99m Tc and the percentages of the RCP were determined. Five different methods were compared with the standard RCP testing method (ITLC - SG, 2x20 cm): Whatman 3MM (1x10 cm) with acetone and dichloro - methane (method 1); Whatman 3MM (1x1 0 cm) with ethyl acetate (method 2); aluminum oxide - coated plastic thin - layer chromatography (TLC) plate (1x10 cm) and ethanol (method 3); Whatman 3MM (2x20 cm) with acetone and dichloro - methane (method 4); solid - phase extraction method C18 cartridge (meth od 5). RESULTS: The average values of RCP were 95,30% ± 1,28% (method 1), 93,95 ± 0,61% (method 2), 96,85% ± 0,93% (method 3), 92,94% ± 0,99% (method 4) and 96,25% ± 2,57% (method 5) (n=12 each), and 93,15% ± 1,13% for the standard method (n=19). There we re statistical significant differences in the values obtained for methods 1 (P=0,001), 3 (P=0,000) and 5 (P=0,004), and there were no statistical significant differences in the values obtained for methods 2 (P=0,113) and 4 (P=0,327). CONCLUSION: From the results obtained, methods 2 and 4 showed a higher correlation with the standard method. Unlike method 4, method 2 is less time - consuming than the reference method and can overcome the problems associated with the solvent toxicity. The remaining methods (1, 3 and 5) tended to overestimate RCP value compared to the standard method.
Resumo:
Introduction: Although relative uptake values aren’t the most important objective of a 99mTc-DMSA scan, they are important quantitative information. In most of the dynamic renal scintigraphies attenuation correction is essential if one wants to obtain a reliable result of the quantification process. Although in DMSA scans the absent of significant background and the lesser attenuation in pediatric patients, makes that this attenuation correction techniques are actually not applied. The geometric mean is the most common method, but that includes the acquisition of an anterior (extra) projection, which it is not acquired by a large number of NM departments. This method and the attenuation factors proposed by Tonnesen will be correlated with the absence of attenuation correction procedures. Material and Methods: Images from 20 individuals (aged 3 years +/- 2) were used and the two attenuation correction methods applied. The mean time of acquisition (time post DMSA administration) was 3.5 hours +/- 0.8h. Results: The absence of attenuation correction showed a good correlation with both attenuation methods (r=0.73 +/- 0.11) and the mean difference verified on the uptake values between the different methods were 4 +/- 3. The correlation was higher when the age was lower. The attenuation correction methods correlation was higher between them two than with the “no attenuation correction” method (r=0.82 +/- 0.8), and the mean differences of the uptake values were 2 +/- 2. Conclusion: The decision of not doing any kind of attenuation correction method can be justified by the minor differences verified on the relative kidney uptake values. Nevertheless, if it is recognized that there is a need for an accurate value of the relative kidney uptake, then an attenuation correction method should be used. Attenuation correction factors proposed by Tonnesen can be easily implemented and so become a practical and easy to implement alternative, namely when the anterior projection - needed for the geometric mean methodology – is not acquired.