910 resultados para 2ND RULE
Resumo:
Purpose: For ultra-endurance athletes, whose energy expenditure is likely to be at the extremes of human tolerance for sustained periods of time, there is increased concern regarding meeting energy needs. Due to the lack of data outlining the energy requirements of such athletes, it is possible that those participating in ultra-endurance exercise are compromising performance, as well as health, as a result of inadequate nutrition and energy intake. To provide insight into this dilemma, we have presented a case study of a 37-yr-old ultra-marathon runner as he runs around the coast of Australia. Methods: Total energy expenditure was measured over a 2-wk period using the doubly labeled water technique. Results: The average total energy expenditure of the case subject was 6321 kcal.d(-1). Based on the expected accuracy and precision of the doubly labeled water technique the subject's total energy expenditure might range between 6095 and 6550 kcal.d(-1). The subject's average daily water turnover was 6.083 L over the 14-d period and might range between 5.9 L and 6.3 L.d(-1). Conclusions: This information will provide a guide to the energy requirements of ultra-endurance running and enable athletes, nutritionists, and coaches to optimize performance without compromising the health of the participant.
Resumo:
Reaching out to grasp an object (prehension) is a deceptively elegant and skilled behavior. The movement prior to object contact can be described as having two components [1], the movement of the hand to an appropriate location for gripping the object, the transport component, and the opening and closing of the aperture between the fingers as they prepare to grip the target, the grasp component. The grasp component is sensitive to the size of the object, so that a larger grasp aperture is formed for wider objects [1]; the maximum grasp aperture (MGA) is a little wider than the width of the target object and occurs later in the movement for larger objects [1, 2]. We present a simple model that can account for the temporal relationship between the transport and grasp components, We report the results of an experiment providing empirical support for our rule of thumb. The model provides a simple, but plausible, account of a neural control strategy that has been the center of debate over the last two decades.
Resumo:
The relation between patient and physician in most modern Health Care Sys- tems is sparse, limited in time and very in exible. On the other hand, and in contradiction with several recent studies, most physicians do not rely their patient diagnostics evaluations on intertwined psychological and social nature factors. Facing these problems and trying to improve the patient/physician relation we present a mobile health care solution to im- prove the interaction between the physician and his patients. The solution serves not only as a privileged mean of communication between physicians and patients but also as an evolutionary intelligent platform delivering a mobile rule based system.
Resumo:
In recent years, several new coffee cultivars recommended for different regions have been released. However, the performance of these varieties in many traditionally producing regions is unknown. Difference of climate and soil may jeopardize the productivity of the new cultivars and cause losses to farmers. The objective of this study is to evaluate the vegetative growth and productive genotypes of C. arabica in the conditions of the Northwestern Rio de Janeiro State, Brazil. The experiment was settled in 2007, in Panorama 1 Farm, located in the municipality of Varre Sai, RJ. Twenty-five genotypes of C. arabica were planted in a spacing of 2.5 × 0.8 m, using a completely randomized design with five replications and eight plants per plot. There were eight measurements of vegetative growth represented by plant height, stem diameter and number of plagiotropic branches. Assessments of productivity were also performed in years 2009 and 2010. There was a positive phenotypic correlation among vegetative characteristics and between vegetative characteristics and yield in the first harvest, while in the second harvest only the number of plagiotropic branches was positively correlated with yield. Up to date, the genotypes Catucaí amarelo 2 SL, Catiguá MG 02, Acauã, Palma II, Sabiá 398, IPR 103/ Iapar, IPR 100/Iapar, H 419-10-6-2-12-1, Catucaí amarelo 24 / 137, Iapar 59, Catucaí amarelo 20/15, H 419-10-6-2-5-10-1 and H 419-10-6-2-5-1 had the highest average yield after two harvests.
Resumo:
Purpose - This study aims to investigate the influence of tube potential (kVp) variation in relation to perceptual image quality and effective dose (E) for pelvis using automatic exposure control (AEC) and non-AEC in a Computed Radiography (CR) system. Methods and materials - To determine the effects of using AEC and non-AEC by applying the 10 kVp rule in two experiments using an anthropomorphic pelvis phantom. Images were acquired using 10 kVp increments (60–120 kVp) for both experiments. The first experiment, based on seven AEC combinations, produced 49 images. The mean mAs from each kVp increment were used as a baseline for the second experiment producing 35 images. A total of 84 images were produced and a panel of 5 experienced observers participated for the image scoring using the two alternative forced choice (2AFC) visual grading software. PCXMC software was used to estimate E. Results - A decrease in perceptual image quality as the kVp increases was observed both in non-AEC and AEC experiments, however no significant statistical differences (p > 0.05) were found. Image quality scores from all observers at 10 kVp increments for all mAs values using non-AEC mode demonstrates a better score up to 90 kVp. E results show a statistically significant decrease (p = 0.000) on the 75th quartile from 0.37 mSv at 60 kVp to 0.13 mSv at 120 kVp when applying the 10 kVp rule in non-AEC mode. Conclusion - Using the 10 kVp rule, no significant reduction in perceptual image quality is observed when increasing kVp whilst a marked and significant E reduction is observed.
Resumo:
Relatório de Estágio apresentado à Escola Superior de Educação de Lisboa para obtenção de grau de mestre em Ensino do 1º e 2º CEB
Resumo:
Purpose - To compare the image quality and effective dose applying the 10 kVp rule with manual mode acquisition and AEC mode in PA chest X-ray. Method - 68 images (with and without lesions) were acquired using an anthropomorphic chest phantom using a Wolverson Arcoma X-ray unit. These images were compared against a reference image using the 2 alternative forced choice (2AFC) method. The effective dose (E) was calculated using PCXMC software using the exposure parameters and the DAP. The exposure index (lgM provided by Agfa systems) was recorded. Results - Exposure time decreases more when applying the 10 kVp rule with manual mode (50%–28%) when compared with automatic mode (36%–23%). Statistical differences for E between several ionization chambers' combinations for AEC mode were found (p = 0.002). E is lower when using only the right AEC ionization chamber. Considering the image quality there are no statistical differences (p = 0.348) between the different ionization chambers' combinations for AEC mode for images with no lesions. Considering lgM values, it was demonstrated that they were higher when the AEC mode was used compared to the manual mode. It was also observed that lgM values obtained with AEC mode increased as kVp value went up. The image quality scores did not demonstrate statistical significant differences (p = 0.343) for the images with lesions comparing manual with AEC mode. Conclusion - In general the E is lower when manual mode is used. By using the right AEC ionising chamber under the lung the E will be the lowest in comparison to other ionising chambers. The use of the 10 kVp rule did not affect the visibility of the lesions or image quality.
Resumo:
Background - Pelvis and hip radiography are consistently found to be amongst the highest contributors to the collective effective dose (E) in all ten DOSE DATAMED countries in Europe, representing 2.8 to 9.4% of total collective dose (S) in the TOP 20 exams list. The level of image quality should provide all the diagnostic information in order not to jeopardise the diagnosis, but being able to provide the needed clinical information with the minimum dose. A recent study suggests further research to determine whether the “10 kVp rule” would have value for a range of examinations using Computed Radiography (CR) systems. As a “rule of thumb” increasing the kVp by 10 whilst halving the mAs is suggested to give a similar perceptual image quality when compared to the original exposure factors. Aims - In light of the 10kVp rule, this study aims to investigate the influence of tube potential (kVp) variation in relation to perceptual image quality and E for pelvis imaging using automatic exposure control (AEC) and non-AEC in a Computed Radiography (CR) system. Research questions - Does the 10kVp rule works for the pelvis in relation to image quality in a CR system? Does the image quality differs when the AEC is used instead of manual mode using the 10kVp rule and how this impacts on E?
Resumo:
Relatório de estágio apresentado à Escola Superior de Comunicação Social como parte dos requisitos para obtenção de grau de mestre em Jornalismo.