993 resultados para 120499 Engineering Design not elsewhere classified


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Novel current density mapping (CDM) schemes are developed for the design of new actively shielded, clinical magnetic resonance imaging (MRI) magnets. This is an extended inverse method in which the entire potential solution space for the superconductors has been considered, rather than single current density layers. The solution provides an insight into the required superconducting coil pattern for a desired magnet configuration. This information is then used as an initial set of parameters for the magnet structure, and a previously developed hybrid numerical optimization technique is used to obtain the final geometry of the magnet. The CDM scheme is applied to the design of compact symmetric, asymmetric, and open architecture 1.0-1.5 T MRI magnet systems of novel geometry and utility. A new symmetric 1.0-T system that is just I m in length with a full 50-cm diameter of the active, or sensitive, volume (DSV) is detailed, as well as an asymmetric system in which a 50-cm DSV begins just 14 cm from the end of the coil structure. Finally a 1.0-T open magnet system with a full 50-cm DSV is presented. These new designs provide clinically useful homogeneous regions and have appropriately restricted stray fields but, in some of the designs, the DSV is much closer to the end of the magnet system than in conventional designs. These new designs have the potential to reduce patient claustrophobia and improve physician access to patients undergoing scans. (C) 2002 Wiley Periodicals, Inc.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Radio-frequency (RF) coils are a necessary component of magnetic resonance imaging (MRI) systems. When used in transmit operation, they act to generate a homogeneous RF magnetic field within a volume of interest and when in receive operation, they act to receive the nuclear magnetic resonance signal from the RF-excited specimen. This paper outlines a procedure for the design of open RF coils using the time-harmonic inverse method. This method entails the calculation of an ideal current density on a multipaned planar surface that would generate a specified magnetic field within the volume of interest. Because of the averaging effect of the regularization technique in the matrix solution, the specified magnetic field is shaped within an iterative procedure until the generated magnetic field matches the desired magnetic field. The stream-function technique is used to ascertain conductor positions and a method of moments package is then used to finalize the design. An open head/neck coil was designed to operate in a clinical 2T MRI system and the presented results prove the efficacy of this design methodology.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The emphasis of this work is on the optimal design of MRI magnets with both superconducting coils and ferromagnetic rings. The work is directed to the automated design of MRI magnet systems containing superconducting wire and both `cold' and `warm' iron. Details of the optimization procedure are given and the results show combined superconducting and iron material MRI magnets with excellent field characteristics. Strong, homogeneous central magnetic fields are produced with little stray or external field leakage. The field calculations are performed using a semi-analytical method for both current coil and iron material sources. Design examples for symmetric, open and asymmetric clinical MRI magnets containing both superconducting coils and ferromagnetic material are presented.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Magnetic resonance imaging (MRI) magnets have very stringent constraints on the homogeneity of the static magnetic field that they generate over desired imaging regions. The magnet system also preferably generates very little stray field external to its structure, so that ease of siting and safety are assured. This work concentrates on deriving, means of rapidly computing the effect of 'cold' and 'warm' ferromagnetic material in or around the superconducting magnet system, so as to facilitate the automated design of hybrid material MR magnets. A complete scheme for the direct calculation of the spherical harmonics of the magnetic field generated by a circular ring of ferromagnetic material is derived under the conditions of arbitrary external magnetizing fields. The magnetic field produced by the superconducting coils in the system is computed using previously developed methods. The final, hybrid algorithm is fast enough for use in large-scale optimization methods. The resultant fields from a practical example of a 4 T, clinical MRI magnet containing both superconducting coils and magnetic material are presented.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Lifter use in dryers improves mass transfer by increasing the amount of surface area available for transfer and also by increasing the velocity of gas over the particle surface. An even cross-sectional distribution of particles in a dryer improves the efficiency of operation by ensuring that evaporation from falling particles is taking place for the maximum fraction of the rotation period of the drier. Studies on lifter design to improve the cross-sectional particle distribution were performed on angled lifters. A single lifter was used and the mass-transfer rate examined as a function of angular lifter displacement. Analysis of the mass transfer characteristics of single lifters allowed performance comparisons and recommendations for lifter design.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A parallel computing environment to support optimization of large-scale engineering systems is designed and implemented on Windows-based personal computer networks, using the master-worker model and the Parallel Virtual Machine (PVM). It is involved in decomposition of a large engineering system into a number of smaller subsystems optimized in parallel on worker nodes and coordination of subsystem optimization results on the master node. The environment consists of six functional modules, i.e. the master control, the optimization model generator, the optimizer, the data manager, the monitor, and the post processor. Object-oriented design of these modules is presented. The environment supports steps from the generation of optimization models to the solution and the visualization on networks of computers. User-friendly graphical interfaces make it easy to define the problem, and monitor and steer the optimization process. It has been verified by an example of a large space truss optimization. (C) 2004 Elsevier Ltd. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Cultivation technologies promoting organization of mammalian cells in three dimensions are essential for gene-function analyses as well as drug testing and represent the first step toward the design of tissue replacements and bioartificial organs. Embedded in a three-dimensional environment, cells are expected to develop tissue-like higher order intercellular structures (cell-cell contacts, extracellular matrix) that orchestrate cellular functions including proliferation, differentiation, apoptosis, and angiogenesis with unmatched quality. We have refined the hanging drop cultivation technology to pioneer beating heart microtissues derived from pure primary rat and mouse cardiomyocyte cultures as well as mixed populations reflecting the cell type composition of rodent hearts. Phenotypic characterization combined with detailed analysis of muscle-specific cell traits, extracellular matrix components, as well as endogenous vascular endothelial growth factor (VEGF) expression profiles of heart microtissues revealed (1) a linear cell number-microtissue size correlation, (2) intermicrotissue superstructures, (3) retention of key cardiomyocyte-specific cell qualities, (4) a sophisticated extracellular matrix, and (5) a high degree of self-organization exemplified by the tendency of muscle structures to assemble at the periphery of these myocardial spheroids. Furthermore (6), myocardial spheroids support endogenous VEGF expression in a size-dependent manner that will likely promote vascularization of heart microtissues produced from defined cell mixtures as well as support connection to the host vascular system after implantation. As cardiomyocytes are known to be refractory to current transfection technologies we have designed lentivirus-based transduction strategies to lead the way for genetic engineering of myocardial microtissues in a clinical setting.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Most adverse environmental impacts result from design decisions made long before manufacturing or usage. In order to prevent this situation, several authors have proposed the application of life cycle assessment (LCA) at the very first phases of the design of a process, a product or a service. The study in this paper presents an innovative thermal drying process for sewage sludge called fry-drying, in which dewatered sludge is directly contacted in the dryer with hot recycled cooking oils (RCO) as the heat medium. Considering the practical difficulties for the disposal of these two wastes, fry-drying presents a potentially convenient method for their combined elimination by incineration of the final fry-dried sludge. An analytical comparison between a conventional drying process and the new proposed fry-drying process is reported, with reference to some environmental impact categories. The results of this study, applied at the earliest stages of the design of the process, assist evaluation of the feasibility of such system compared to a current disposal process for the drying and incineration of sewage sludge.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A simple method for the design of ultra-wideband antennas in planar format is presented. This method is demonstrated for a high-dielectric-constant substrate material, which allows for a considerable antenna size reduction. Simulations are performed using Ansoft's High-Frequency Structure Simulator (HFSS) for antennas assuming Du-Pont951 (epsilon(r) = 7.8) and RT6010LM (epsilon(r) = 10.2) substrates. For the 1-mm-thick DuPont951, the designed antenna with 22 X 28 nun dimensions features a 10-dB return-loss band width front 2.7 GHz to more than 15 GHz. For the 0.64-mm-thick RT6010LM a 20 X 26 nun antenna exhibits a 10-dB return loss bandwidth from 3.1 to 15 GHz. Both antennas feature nearly omnidirectional properties across the whole 10-dB return-loss bandwidth. The validity of the presented UWB antenna design strategy is confirmed by measurements performed on a prototype developed on RT6010LM substrate. (c) 2006 Wiley Periodicals, Inc.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

In this paper, a novel design procedure for designing a compact UWB antipodal Vivaldi antenna is presented. The antenna operates over the UWB frequency, band from 3.1 to more than 10.6 GHz. Its measured far-field radiation is directive and its peak gain is 10.2 dBi in the specified band. The antenna pulse response shows negligible distortion, indicating that it can be useful in a precision ranging and imaging instrumentation. (c) 2006 Wiley Periodicals, Inc.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The operation of polymer electrolyte membrane fuel cells (PEMFCs) with dry feeds has been examined with different fuel cell flow channel designs as functions of pressure, temperature and flow rate. Auto-humidified (or self-humidifying) PEMFC operation is improved at higher pressures and low gas velocities where axial dispersion enhances back-mixing of the product water with the dry feed. We demonstrate auto-humidified operation of the channel-less, self-draining fuel cell, based on a stirred tank reactor; data is presented showing auto-humidified operation from 25 to 115 degrees C at 1 and 3 atm. Design and operating requirements are derived for the auto-humidified operation of the channel-less, self-draining fuel cell. The auto-humidified self-draining fuel cell outperforms a fully humidified serpentine flow channel fuel cell at high current densities. The new design offers substantial benefits for simplicity of operation and control including: the ability to self-drain reducing flooding, the ability to uniformly disperse water removing current gradients and the ability to operate on dry feeds eliminating the need for humidifiers. Additionally, the design lends itself well to a modular design concept. (c) 2005 Elsevier B.V. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Three important goals in describing software design patterns are: generality, precision, and understandability. To address these goals, this paper presents an integrated approach to specifying patterns using Object-Z and UML. To achieve the generality goal, we adopt a role-based metamodeling approach to define patterns. With this approach, each pattern is defined as a pattern role model. To achieve precision, we formalize role concepts using Object-Z (a role metamodel) and use these concepts to define patterns (pattern role models). To achieve understandability, we represent the role metamodel and pattern role models visually using UML. Our pattern role models provide a precise basis for pattern-based model transformations or refactoring approaches.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

An inverse methodology to assist in the design of radio-frequency (RF) head coils for high field MRI application is described in this work. Free space time-harmonic electromagnetic Green's functions and preemphasized B1 field are used to calculate the current density on the coil cylinder. With B1 field preemphasized and lowered in the middle of the RF transverse plane, the calculated current distribution can generate an internal magnetic field that can reduce the EM field/tissue interactions at high frequencies. The current distribution of a head coil operating at 4 T is calculated using inverse methodology with preemphasized B1 fields. FDTD is employed to calculate B1 field and signal intensity inside a homogenous cylindrical phantom and human head. A comparison with conventional RF birdcage coil is reported here and demonstrated that inverse-method designed coil with preemphasized B1 field can help in decreasing the notorious bright region caused by EM field/tissue interactions in the human head images at 4 T.