945 resultados para welding clamp


Relevância:

10.00% 10.00%

Publicador:

Resumo:

1. The relative permeability of the native P2X receptor channel to monovalent and divalent inorganic and organic cations was determined from reversal potential measurements of ATP-evoked currents in parasympathetic neurones dissociated from rat submandibular ganglia using the dialysed whole-cell patch clamp technique. 2. The P2X receptor-channel exhibited weak selectivity among the alkali metals with a selectivity sequence of Na+ > Li+ > Cs+ > Rb+ > K+, and permeability ratios relative to Cs+ (P-X/P-Cs) ranging from 1. 11 to 0.86. 3. The selectivity for the divalent alkaline earth cations was also weak with the sequence Ca2+ > Sr2+ > Ba2+ > Mn2+ > Mg2+. ATP-evoked currents were strongly inhibited when the extracellular divalent cation concentration was increased. 4, The calculated permeability ratios of different ammonium cations are higher than those of the alkali metal cations. The permeability sequence obtained for the saturated organic cations is inversely correlated with the size of the cation. The unsaturated organic cations have a higher permeability than that predicted by molecular size. 5. Acidification to pH 6.2 increased the ATP-induced current amplitude twofold, whereas alkalization to 8.2 and 9.2 markedly reduced current amplitude. Cell dialysis with either anti-P2X(2) and/or anti-P2X(4) but not anti-P2X(1) antibodies attenuated the ATP-evoked current amplitude. Taken together, these data are consistent with homomeric and/or heteromeric P2X(2) and P2X(4) receptor subtypes expressed in rat submandibular neurones. 6. The permeability ratios for the series of monovalent organic cations, with the exception of unsaturated cations, were approximately related to the ionic size. The relative permeabilities of the monovalent inoganic and organic cations tested are similar to those reported previously for cloned rat P2X2 receptors expressed in mammalian cells.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The properties of single Ca2+-activated K+ (BK) channels in neonatal rat intracardiac neurons were investigated using the patch-clamp recording technique. In symmetrical 140 mM K+, the single-channel slope conductance was linear in the voltage range -60/+60 mV. and was 207+/-19 pS. Na+ ions were not measurably permeant through the open channel. Channel activity increased with the cytoplasmic free Ca2+ concentration ([Ca2+],) with a Hill plot giving a half-saturating [Ca2+] (K-0.5) of 1.35 muM and slope of congruent to3. The BK channel was inhibited reversibly by external tetraethylammonium (TEA) ions, charybdotoxin, and quinine and was resistant to block by 4-aminopyridine and apamin. Ionomycin (1-10 muM) increased BK channel activity in the cell-attached recording configuration. The resting activity was consistent with a [Ca2+](i)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Voltage-gated sodium channels drive the initial depolarization phase of the cardiac action potential and therefore critically determine conduction of excitation through the heart. In patients, deletions or loss-of-function mutations of the cardiac sodium channel gene, SCN5A, have been associated with a wide range of arrhythmias including bradycardia (heart rate slowing), atrioventricular conduction delay, and ventricular fibrillation. The pathophysiological basis of these clinical conditions is unresolved. Here we show that disruption of the mouse cardiac sodium channel gene, Scn5a, causes intrauterine lethality in homozygotes with severe defects in ventricular morphogenesis whereas heterozygotes show normal survival. Whole-cell patch clamp analyses of isolated ventricular myocytes from adult Scn5a(+/-) mice demonstrate a approximate to50% reduction in sodium conductance. Scn5a(+/-) hearts have several defects including impaired atrioventricular conduction, delayed intramyocardial conduction, increased ventricular refractoriness, and ventricular tachycardia with characteristics of reentrant excitation. These findings reconcile reduced activity of the cardiac sodium channel leading to slowed conduction with several apparently diverse clinical phenotypes, providing a model for the detailed analysis of the pathophysiology of arrhythmias.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Objective: To investigate the effects of rosiglitazone (RSG) on insulin sensitivity and regional adiposity (including intrahepatic fat) in patients with type 2 diabetes. Research Methods and Procedures: We examined the effect of RSG (8 mg/day, 2 divided doses) compared with placebo on insulin sensitivity and body composition in 33 type 2 diabetic patients. Measurements of insulin sensitivity (euglycemic hyperinsulinemic clamp), body fat (abdominal magnetic resonance imaging and DXA), and liver fat (magnetic resonance spectroscopy) were taken at baseline and repeated after 16 weeks of treatment. Results: There was a significant improvement in glycemic control (glycosylated hemoglobin -0.7 +/- 0.7%, p less than or equal to 0.05) and an 86% increase in insulin sensitivity in the RSG group (glucose-disposal rate change from baseline: 17.5 +/- 14.5 mumol glucose/min/kg free fat mass, P < 0.05), but no significant change in the placebo group compared with baseline. Total body weight and fat mass increased (p &LE; 0.05) with RSG (2.1 +/- 2.0 kg and 1.4 +/- 1.6 kg, respectively) with 95% of the increase in adiposity occurring in nonabdominal regions. In the abdominal region, RSG increased subcutaneous fat area by 8% (25.0 +/- 28.7 cm(2), p = 0.02), did not alter intra-abdominal fat area, and reduced intrahepatic fat levels by 45% (-6.7 +/- 9.7%, concentration relative to water). Discussion: Our data indicate that RSG greatly improves insulin sensitivity in patients with type 2 diabetes and is associated with an increase in adiposity in subcutaneous but not visceral body regions.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The presence of a basal nonselective cation permeability was mainly investigated in primary cultures of rat cardiac microvascular endothelial cells (CMEC) by applying both the patch-clamp technique and Fura-2 microfluorimetry. With low EGTA in the pipette solution, the resting membrane potential of CMEC was -21.2 +/- 1.1 mV, and a Ca2+-activated Cl- conductance was present. When the intracellular Ca2+ was buffered with high EGTA, the membrane potential decreased to 5.5 +/- 1.2 mV. In this condition, full or partial substitution of external Na+ by NMDG(+) proportionally reduced the inward component of the basal I-V relationship. This current was dependent on extracellular monovalent cations with a permeability sequence of K+ > Cs+ > Na+ > Li+ and was inhibited by Ca2+, La3+, Gd3+, and amiloride. The K+/Na+ permeability ratio, determined using the Goldman-Hodgkin-Katz equation, was 2.01. The outward component of the basal I-V relationship was reduced when intracellular K+ was replaced by NMDG(+), but was not sensitive to substitution by Cs+. Finally, microfluorimetric experiments indicated the existence of a basal Ca2+ entry pathway, inhibited by La3+ and Gd3+. The basal nonselective cation permeability in CMEC could be involved both in the control of myocardial ionic homeostasis, according to the model of the blood-heart barrier, and in the modulation of Ca2+ -dependent processes. (C) 2002 Elsevier Science (USA).

Relevância:

10.00% 10.00%

Publicador:

Resumo:

delta-Atracotoxin-Ar1a (delta-ACTX-Ar1a) is the major polypeptide neurotoxin isolated from the venom of the male Sydney funnel-web spider, Atrax robustus. This neurotoxin targets both insect and mammalian voltage-gated sodium channels, where it competes with scorpion alpha-toxins for neurotoxin receptor site-3 to slow sodium-channel inactivation. Progress in characterizing the structure and mechanism of action of this toxin has been hampered by the limited supply of pure toxin from natural sources. In this paper, we describe the first successful chemical synthesis and oxidative refolding of the four-disulfide bond containing delta-ACTX-Ar1a. This synthesis involved solid-phase Boc chemistry using double coupling, followed by oxidative folding of purified peptide using a buffer of 2 M GdnHCl and glutathione/glutathiol in a 1:1 mixture of 2-propanol (pH 8.5). Successful oxidation and refolding was confirmed using both chemical and pharmacological characterization. Ion spray mass spectrometry was employed to confirm the molecular weight. H-1 NMR analysis showed identical chemical shifts for native and synthetic toxins, indicating that the synthetic toxin adopts the native fold. Pharmacological studies employing whole-cell patch clamp recordings from rat dorsal root ganglion neurons confirmed that synthetic delta-ACTX-Ar1a produced a slowing of the sodium current inactivation and hyperpolarizing shifts in the voltage-dependence of activation and inactivation similar to native toxin. Under current clamp conditions, we show for the first time that delta-ACTX-Ar1a produces spontaneous repetitive plateau potentials underlying the clinical symptoms seen during envenomation. This successful oxidative refolding of synthetic delta-ACTX-Ar1a paves the way for future structure-activity studies to determine the toxin pharmacophore.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Mestrado em Segurança e Higiene do Trabalho.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Mestrado em Segurança e Higiene no Trabalho.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Bearing in mind the potential adverse health effects of ultrafine particles, it is of paramount importance to perform effective monitoring of nanosized particles in several microenvironments, which may include ambient air, indoor air, and also occupational environments. In fact, effective and accurate monitoring is the first step to obtaining a set of data that could be used further on to perform subsequent evaluations such as risk assessment and epidemiologic studies, thus proposing good working practices such as containment measures in order to reduce occupational exposure. This paper presents a useful methodology for monitoring ultrafine particles/nanoparticles in several microenvironments, using online analyzers and also sampling systems that allow further characterization on collected nanoparticles. This methodology was validated in three case studies presented in the paper, which assess monitoring of nanosized particles in the outdoor atmosphere, during cooking operations, and in a welding workshop.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Mestrado em Engenharia Electrotécnica – Sistemas Eléctricos de Energia

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Trabalho Final de Mestrado para obtenção do grau de Mestre em Engenharia Mecânica

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Os objectivos principais deste estudo são a caracterização de uma das linhas de extrusão existentes na Cabelte, nomeadamente a linha de extrusão de referência EP5, composta por duas extrusoras. Pretende-se fazer a determinação de indicadores energéticos e de processo e a optimização do consumo energético, no que diz respeito à energia consumida e às perdas térmicas relativas a esta linha. Para fazer a monitorização da linha de extrusão EP5 foi colocado no quadro geral dessa linha um equipamento central de medida de forma a ser possível a sua monitorização. No entanto, para a extrusora auxiliar as medições foram efectuadas com uma pinça amperimétrica e um fasímetro. Foram também efectuados ensaios onde foi avaliada a quantidade de material transformada, para isso foi utilizado um equipamento de pesagem, doseador gravimétrico aplicado nas extrusoras. As medições de temperatura para os cálculos das perdas térmicas da extrusora principal e para a caracterização dos materiais plásticos, foram efectuadas utilizando um termómetro digital. Foram efectuados ensaios de débito às extrusoras auxiliar e principal e foi estudada a variação do factor de potência em função da rotação do fuso. Na perspectiva do utilizador final a optimização para a utilização racional de energia está na redução de encargos da factura de energia eléctrica. Essa factura não depende só da quantidade mas também do modo temporal como se utiliza essa energia, principalmente a energia eléctrica, bastante dependente do período em que é consumida. Uma metodologia diferente no planeamento da produção, contemplando o fabrico dos cabos com maior custo específico nas horas de menor custo energético, implicaria uma redução dos custos específicos de 18,7% para o horário de verão e de 20,4% para o horário de inverno. Os materiais de revestimento utilizados (PE e PVC), influenciam directamente os custos energéticos, uma vez que o polietileno (PE) apresenta sempre valores de entalpia superiores (0,317 kWh/kg e 0,281 kWh/kg)) e necessita de temperaturas de trabalho mais elevadas do que o policloreto de vinilo (PVC) (0,141 kWh/kg e 0,124 kWh/kg). O consumo específico tendencialmente diminui à medida que aumenta a rotação do fuso, até se atingir o valor de rotação óptimo, a partir do qual esta tendência se inverte. O cosφ para as duas extrusoras em estudo, aumenta sempre com o aumento de rotação do fuso. Este estudo permitiu avaliar as condições óptimas no processo de revestimento dos cabos, de forma a minimizarmos os consumos energéticos. A redução de toda a espécie de desperdícios (sobre consumos, desperdício em purgas) é uma prioridade de gestão que alia também a eficácia à eficiência, e constitui uma ferramenta fundamental para assegurar o futuro da empresa. O valor médio lido para o factor de potência (0,38) da linha EP5, valor extremamente baixo e que vem associado à energia reactiva, além do factor económico que lhe está inerente, condiciona futuras ampliações. A forma de se corrigir o factor de potência é instalando uma bateria de condensadores de 500 kVAr. Considerando o novo sistema tarifário aplicado à energia reactiva, vamos ter um ganho de 36167,4 Euro/ano e o período de retorno de investimento é de 0,37 ano (4,5 meses). Esta medida implica também uma redução anual na quantidade de CO2 emitida de 6,5%. A quantificação das perdas térmicas é importante, pois só desta forma se podem definir modos de actuação de forma a aumentar a eficiência energética. Se não existir conhecimento profundo dos processos e metodologias correctas, não podem existir soluções eficientes, logo é importante medir antes de avançar com qualquer medida de gestão.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Trabalho Final de Mestrado para obtenção do grau de Mestre em Engenharia Química e Biológica Ramo de processos químicos

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Trabalho Final de Mestrado para obtenção do grau de Mestre em Engenharia Mecânica