927 resultados para triple junction


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Developed for use with triple GEM detectors, the GEM Electronic Board (GEB) forms a crucial part of the electronics readout system being developed as part of the CMS muon upgrade program. The objective of the GEB is threefold; to provide stable powering and ground for the VFAT3 front ends, to enable high-speed communication between 24 VFAT3 front ends and an optohybrid, and to shield the GEM detector from electromagnetic interference. The paper describes the concept and design of a large-size GEB in detail, highlighting the challenges in terms of design and feasibility of this deceptively difficult system component.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Previously we have employed antibodies to the tight junction (TJ)-associated proteins ZO-1 and occludin to describe endothelial tight junction abnormalities, in lesional and normal appearing white matter, in primary and secondary progressive multiple sclerosis (MS). This work is extended here by use of antibodies to the independent TJ-specific proteins and junctional adhesion molecule A & B (JAM-A, JAM-B). We have also assessed the expression in MS of ß-catenin, a protein specific to the TJ-associated adherens junction. Immunocytochemistry and semiquantitative confocal microscopy for JAM-A and ß-catenin was performed on snap-frozen sections from MS cases (n = 11) and controls (n = 6). Data on 1,443 blood vessels was acquired from active lesions (n = 13), inactive lesions (n = 13), NAWM (n = 20) and control white matter (n = 13). In MS abnormal JAM-A expression was found in active (46%) and inactive lesions (21%), comparable to previous data using ZO-1. However, a lower level of TJ abnormality was found in MS NAWM using JAM-A (3%) compared to ZO-1 (13%). JAM-B was strongly expressed on a small number of large blood vessels in control and MS tissues but at too low a level for quantitative analysis. By comparison with the high levels of abnormality observed with the TJ proteins, the adherens junction protein ß-catenin was normally expressed in all MS and control tissue categories. These results confirm, by use of the independent marker JAM-A, that TJ abnormalities are most frequent in active white matter lesions. Altered expression of JAM-A, in addition to affecting junctional tightness may also both reflect and affect leukocyte trafficking, with implications for immune status within the diseased CNS. Conversely, the adherens junction component of the TJ, as indicated by ß-catenin expression is normally expressed in all MS and control tissue categories.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The enantiomerically pure ligands LRR and LSS (N,N'-bis(-2,2'-bipyridyl-5-yl)carbonyl-(1S/R,2S/R)-(+/-)-1,2-diaminocyclohexane) have been synthesised by linking two 2,2'-bipyridine units by (R,R)- and (S,S)-1,2-diaminocyclohexane respectively. The crystal structure confirmed that the ligand had a twisted orientation between the two chelating units. The reaction of LRR and LSS with Fe(II), Co(III), Cd(II) and Zn(II) afforded dinuclear complexes confirmed by ES mass spectroscopy. CD spectroscopy indicated that the chiral diaminocyclohexane conferred helicity to the metal centre giving a dominant triple helicate diastereoisomer, with the LRR ligand giving a delta-configuration of each metal centre (P helicate) and the LSS ligand a lambda configuration (M helicate). 1H NMR spectroscopy confirmed a dominant major diastereoisomer with cadmium. The Zn(II) and Cd(II) complexes however were observed to undergo rapid ligand dissociation in solution.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This is the first paper to describe performance assessment of triple and double gate FinFETs for High Performance (HP), Low Operating Power (LOP) and Low Standby Power (LSTP) logic technologies is investigated. The impact of gate work-function, spacer width, lateral source/drain doping gradient, fin aspect ratio, fin thickness on device performance, has been analysed in detail and guidelines are presented to meet ITRS specification at 65 and 45 nm nodes. Optimal design of lateral source/drain doping profile can not only effectively control short channel effects, yielding low off-current, but also achieve low values of intrinsic gate delay.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The synthesis and photophysical evaluation of two enatiomerially pure dimetallic lanthanide luminescent triple-stranded helicates is described. The two systems, formed from the chiral (R,R) ligand 1 and (S,S) ligand 2, were produced as single species in solution, where the excitation of either the naphthalene antennae or the pyridiyl units gave rise to Eu(III) emission in a variety of solvents. Excitation of the antennae also gave rise to circularly polarized Eu(III) luminescence emissions for Eu2:13 and Eu2:23 that were of equal intensity and opposite sign, confirming their enantiomeric nature in solution providing a basis upon which we were able to assign the absolute configurations of Eu2:13 and Eu2:23.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The synthesis of the C2-symmetrical ligand 1 consisting of two naphthalene units connected to two pyridine-2,6-dicarboxamide moieties linked by a xylene spacer and the formation of LnIII-based (Ln1/4 Sm, Eu, Tb, and Lu) dimetallic helicates [Ln2 · 13] in MeCN by means of a metal-directed synthesis is described. By analyzing the metal-induced changes in the absorption and the fluorescence of 1, the formation of the helicates, and the presence of a second species [Ln2 · 12] was confirmed by nonlinear- regression analysis. While significant changes were observed in the photophysical properties of 1, the most dramatic changes were observed in the metal-centred lanthanide emissions, upon excitation of the naphthalene antennae. From the changes in the lanthanide emission, we were able to demonstrate that these helicates were formed in high yields (ca. 90% after the addition of 0.6 equiv. of LnIII), with high binding constants, which matched well with that determined from the changes in the absorption spectra. The formation of the LuIII helicate, [ Lu2 · 13 ] , was also investigated for comparison purposes, as we were unable to obtain accurate binding constants from the changes in the fluorescence emission upon formation of [Sm2 · 13], [Eu2 · 13], and [Tb2 · 13].

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper proposes a new hierarchical learning structure, namely the holistic triple learning (HTL), for extending the binary support vector machine (SVM) to multi-classification problems. For an N-class problem, a HTL constructs a decision tree up to a depth of A leaf node of the decision tree is allowed to be placed with a holistic triple learning unit whose generalisation abilities are assessed and approved. Meanwhile, the remaining nodes in the decision tree each accommodate a standard binary SVM classifier. The holistic triple classifier is a regression model trained on three classes, whose training algorithm is originated from a recently proposed implementation technique, namely the least-squares support vector machine (LS-SVM). A major novelty with the holistic triple classifier is the reduced number of support vectors in the solution. For the resultant HTL-SVM, an upper bound of the generalisation error can be obtained. The time complexity of training the HTL-SVM is analysed, and is shown to be comparable to that of training the one-versus-one (1-vs.-1) SVM, particularly on small-scale datasets. Empirical studies show that the proposed HTL-SVM achieves competitive classification accuracy with a reduced number of support vectors compared to the popular 1-vs-1 alternative.