959 resultados para total hip prostheses


Relevância:

30.00% 30.00%

Publicador:

Resumo:

Background During gait, the hip flexors generate 40% of the total power. Nevertheless, no device has been tested extensively for clinical purposes to cope with weakness in the hip flexors in patients with stroke. Objective The purpose of this study was to assess the efficacy and safety of a newly developed hip flexion assist orthosis in adult patients with hemiparesis after stroke. Design The study used a prospective, randomized, before-after trial design. The inclusion criteria were hemiparesis resulting from stroke (onset ≥8 weeks); ability to walk, even if with assistance; and hip flexion weakness (Medical Research Council Scale score ≤4).¦METHODS: /b> The main outcome measures were the 10-Meter Walk Test and the Six-Minute Walk Test. Patients also were evaluated with the Trunk Control Test, the Functional Ambulation Categories, the Motricity Index, and hip flexor strength on the Medical Research Council Scale. Sixty-two survivors of stroke were tested in random order with and without the orthosis. Any adverse event associated with its use was recorded.¦RESULTS: /b> Both the Six-Minute Walk Test and the 10-Meter Walk Test scores improved with the use of the orthosis. A significant negative correlation was found for improvement between scores on the 2 main outcome measures with the orthosis and the Functional Ambulation Categories scores. The improvement in Six-Minute Walk Test scores with the orthosis was related inversely to hip flexor strength.¦CONCLUSIONS: /b> The data showed that the use of a hip flexion assist orthosis can improve gait in patients with poststroke hemiparesis, particularly those with more severe walking impairment.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Background:¦Infection after total or partial hip arthroplasty (HA) leads to significant long-­term morbidity and high healthcare cost. We evaluated reasons for treatment failure of different surgical modalities in a 12-­year prosthetic hip joint infection cohort study.¦Method:¦All patients hospitalized at our institution with infected HA were included either retrospectively (1999-­‐2007) or prospectively¦(2008-­‐2010). HA infection was defined as growth of the same microorganism in ≥2 tissues or synovialfluid culture, visible purulence, sinus tract or acute inflammation on tissue histopathology. Outcome analysis was performed at outpatient visits, followed by contacting patients, their relatives and/or treating physicians afterwards.¦Results:¦During the study period, 117 patients with infected HA were identified. We excluded 2 patients due to missing data. The average age was 69 years (range, 33-­‐102 years); 42% were female. HA was mainly performed for osteoarthritis (n=84), followed by trauma (n=22), necrosis (n=4), dysplasia(n=2), rheumatoid arthritis (n=1), osteosarcoma (n=1) and tuberculosis (n=1). 28 infections occurred early(≤3 months), 25 delayed (3-­‐24 months) and 63 late (≥24 months after surgery). Infected HA were¦treated with (i) two-­‐stage exchange in 59 patients (51%, cure rate: 93%), (ii) one-­‐stage exchange in 5 (4.3%, cure rate: 100%), (iii) debridement with change of mobile parts in 18 (17%, cure rate: 83%), (iv) debridement without change of mobile¦parts in 17 (14%, cure rate : 53% ), (v) Girdlestone in 13 (11%, cure rate: 100%), and (vi) two-­‐stage exchange followed by¦removal in 3 (2.6%). Patients were followed for an average of 3.9 years (range, 0.1 to 9 years), 7 patients died unrelated to the infected HA. 15 patients (13%) needed additional operations, 1 for mechanical reasons(dislocation of spacer) and 14 for persistent infection: 11 treated with debridement and retention (8 without change; and 3 with change of mobile parts) and 3 with two-­‐stage exchange. The average number of surgery was 2.2 (range, 1 to 5). The infection was finally eradicated in all patients, but the functional outcome remained unsatisfactory in 20% (persistent pain or impaired mobility due to spacer or Girdlestone situation).¦Conclusions:¦Non-­‐respect of current treatment concept leads to treatment failure with subsequent operations. Precise analysis of each treatment failure can be used for improving the treatment algorithm leading to better results.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

BACKGROUND: Clinical results of total ankle arthroplasty with early designs were disappointing. Recently-developed ankle prostheses have good mid-term results; however, limited information is available regarding effects of total ankle arthroplasty on ankle laxity. METHODS: Eight cadaveric lower extremities were tested with a custom device which enabled measurement of multi-axial forces, moments, and displacement during applied axial, shear, and rotational loading. Tests consisted of anterior-posterior and medial-lateral translation and internal-external rotation of the talus relative to the tibia during axial loads on the tibia simulating body weight (700 N) and an unloaded condition (5 N). Tests were performed in neutral, dorsiflexion, and plantarflexion. Laxity was determined for the intact ankle, and following insertion of an unconstrained total ankle implant, comparing load-displacement curve. FINDINGS: Laxity after total ankle arthroplasty did not approximate the normal ankle in most conditions tested. Displacement was significantly greater for total ankle arthroplasty in both posterior and lateral translation, and internal rotation, with 5 N axial loading, and anterior-posterior, medial-lateral translation, and internal-external rotation for 700 N axial loading. For the 700 N axial load condition, in the neutral ankle position, total anterior-posterior translation averaged 0.4 mm (SD 0.2 mm), but 6.0 mm (SD 1.5 mm) after total ankle arthroplasty (P<0.01). This study demonstrated more laxity in the replaced ankle than normal ankle for both unloaded and 700 N axially loaded conditions. INTERPRETATION: These data indicate the increased responsibility of the ligaments for ankle laxity after total ankle arthroplasty and suggest the importance of meticulous ligament reconstruction with total ankle arthroplasty operations.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This study compared the outcome of total knee replacement (TKR) in adult patients with fixed- and mobile-bearing prostheses during the first post-operative year and at five years' follow-up, using gait parameters as a new objective measure. This double-blind randomised controlled clinical trial included 55 patients with mobile-bearing (n = 26) and fixed-bearing (n = 29) prostheses of the same design, evaluated pre-operatively and post-operatively at six weeks, three months, six months, one year and five years. Each participant undertook two walking trials of 30 m and completed the EuroQol questionnaire, Western Ontario and McMaster Universities osteoarthritis index, Knee Society score, and visual analogue scales for pain and stiffness. Gait analysis was performed using five miniature angular rate sensors mounted on the trunk (sacrum), each thigh and calf. The study population was divided into two groups according to age (≤ 70 years versus > 70 years). Improvements in most gait parameters at five years' follow-up were greater for fixed-bearing TKRs in older patients (> 70 years), and greater for mobile-bearing TKRs in younger patients (≤ 70 years). These findings should be confirmed by an extended age controlled study, as the ideal choice of prosthesis might depend on the age of the patient at the time of surgery.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The costs related to the treatment of infected total joint arthroplasties represent an ever groving burden to the society. Different patient-adapted therapeutic options like débridement and retention, 1- or 2-step exchange can be used. If a 2-step exchange is used we have to consider short (2-4 weeks) or long (>4-6 weeks) interval treatment. The Swiss DRG (Diagnose related Groups) determines the reimboursement the hopsital receives for the treatment of an infected total arthroplasty. The review assesses the cost-effectiveness of hospitalisation practices linked to surgical treatment in the two-stage exchange of a prosthetic-joint infection. The aim of this retrospectiv study is to compare the economical impact between a short (2 to 4 weeks) versus a long (6 weeks and above) interval during a two-satge procedure to determine the financial impact. Retrospectiv study of the patients with a two-stage procedure for a hip or knee prosthetic joint infection at CHUV hospital Lausanne (Switzerland) between 2012 and 2013. The review analyses the correlation between the interval length and the length of the hospital stay as well as with the costs and revenues per hospital stay. In average there is a loss of 40′000 Euro per hospitalisation for the treatment of prosthetic joint infection. Revenues never cover all the costs, even with a short interval procedure. This economical loss increases with the length of the hospital stay if a long-term intervall is choosen. The review explores potential for improvement in reimbourement practices and hospitalisation practices in the current Swiss healthcare setting. There should be alternative setups to decrease the burden of medical costs by a) increase the reimboursment for the treatment of infected total joints or by b) splitting the hospital stay with partners (rapid transfer after first operation from center hospital to level 2 hospital and retransfer for second operation to center) in order to increase revenues.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

OBJECTIVE: to characterize the epidemiological profile of patients undergoing hip replacement, primary or revisional. METHODS: we conducted a retrospective, descriptive study, including hip arthroplasties performed from January 2009 to June 2012 in a Belo Horizonte teaching hospital, Minas Gerais State - MG, Brazil. Data were analyzed using descriptive statistics. RESULTS: orthopedic procedures represented 45% of the operations at the hospital in the period, 1.4% hip arthroplasties. There were 125 hip replacements, 85 total, 27 partial and 13 reviews. Among the patients, 40% were male and 60% were female. Age ranged between 20 and 102 years, mean and median of 73 and 76 years, respectively. The most frequent diagnosis (82%) was femoral neck fracture by low-energy trauma caused by falling form standing position. In 13 revision operations, 12 required removal of the prosthesis. The infectious complication led to revision in 54% of the time, followed by dislocation (15%), peri-prosthetic fracture (15%) and aseptic loosening (15%). The infection etiologic agent was identified in 43% of occasions. The average length of the prosthesis to a revision operation was eight months. CONCLUSION: patients undergoing hip arthroplasty are elderly, with femoral neck fracture caused by falling form standing position, affecting more women. The incidence of hip prosthesis loosening was 10%. The main cause of the infection was loosening. The incidence of revisional hip arthroplasty was 10% and the incidence of hospital mortality in patients undergoing hip arthroplasty was 7.2%.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Pour répondre aux exigences du gouvernement fédéral quant aux temps d’attente pour les chirurgies de remplacement du genou et de la hanche, les établissements canadiens ont adopté des stratégies de gestion des listes d’attentes avec des niveaux de succès variables. Notre question de recherche visait à comprendre Quels facteurs ont permis de maintenir dans le temps un temps d’attente répondant aux exigences du gouvernement fédéral pendant au moins 6-12 mois? Nous avons développé un modèle possédant quatre facteurs, inspiré du modèle de Parsons (1977), afin d’analyser les facteurs comprenant la gouvernance, la culture, les ressources, et les outils. Trois études de cas ont été menées. En somme, le 1er cas a été capable d’obtenir les exigences pendant six mois mais incapable de les maintenir, le 2e cas a été capable de maintenir les exigences > 18 mois et le 3e cas a été incapable d’atteindre les objectifs. Des documents furent recueillis et des entrevues furent réalisées auprès des personnes impliquées dans la stratégie. Les résultats indiquent que l’hôpital qui a été en mesure de maintenir le temps d’attente possède certaines caractéristiques: réalisation exclusive de chirurgie de remplacement de la hanche et du genou, présence d’un personnel motivé, non distrait par d’autres préoccupations et un esprit d’équipe fort. Les deux autres cas ont eu à faire face à une culture médicale moins homogène et moins axés sur l’atteinte des cibles; des ressources dispersées et une politique intra-établissement imprécise. Le modèle d’hôpital factory est intéressant dans le cadre d’une chirurgie surspécialisée. Toutefois, les patients sont sélectionnés pour des chirurgies simples et dont le risque de complication est faible. Il ne peut donc pas être retenu comme le modèle durable par excellence.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Resumen basado en el de la publicaci??n

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Background: Significant morbidity and mortality are related to conventional aortic replacement surgery. Endovascular debranching techniques, fenestrated or branched endografts are time consuming and costly.Objective: We alternatively propose to use endovascular approach with parallel grafts for debranching of aortic arch.Methods: Under general anesthesia, 12 F sheaths were inserted in the femoral, axillary and common carotid arteries for vascular accesses. ViaBahn grafts 10 - 15 cm in length were placed into the aortic arch from right common carotid, left common carotid and left axillary arteries, until the tip of each graft reached into the ascending aorta. Through one femoral artery, the aortic stent-graft was positioned and delivered. Soon after, the parallel grafts were sequentially delivered. Self-spanding Wallstents(R) were used for parallel grafts reinforcement. Ballooning was routinely used for parallel grafts and rarely for aortic graft.Results: This technique was used in 2 cases. The first one was a lady with 72 years old, with an aortic retrograde dissection from left subclavian artery and involving remaining arch branches. Through right common carotid artery a stent-graft was placed in the ascending aorta and through the left common carotid artery a ViaBahn was inserted parallel to the former. A thoracic endograft then covered all the aortic arch dissection extending into the ascending aorta close to the sinu-tubular junction. The second case was a 82 year old male patient with a 7 cm aortic arch aneurysm. Through both common carotid arteries ViaBahn grafts were introduced and positioned into the ascending aorta. Soon after, the deployment of the thoracic stent graft covered all parallel grafts of the aortic arch, excluding the aneurysm. Both cases did not have neurologic or cardiac complications and were discharged 10 days after the procedure.Conclusions: This technique may be a good minimal invasive off-the-shelf technical option for aortic arch "debranching". More data and further improvements are required before this promising technique can be widely advocated. (C) 2011 European Society for Vascular Surgery. Published by Elsevier Ltd. All rights reserved.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Purpose: Three-dimensional finite element analysis was used to evaluate the effect of vertical and angular misfit in three-piece implant-supported screw-retained fixed prostheses on the biomechanical response in the peri-implant bone, implants, and prosthetic components. Materials and Methods: Four three-dimensional models were fabricated to represent a right posterior mandibular section with one implant in the region of the second premolar (2PM) and another in the region of the second molar (2M). The implants were splinted by a three-piece implant-supported metal-ceramic prosthesis and differed according to the type of misfit, as represented by four different models: Control = prosthesis with complete fit to the implants; UAM (unilateral angular misfit) = prosthesis presenting unilateral angular misfit of 100 pm in the mesial region of the 2M; UVM (unilateral vertical misfit) = prosthesis presenting unilateral vertical misfit of 100 pm in the mesial region of the 2M; and TVM (total vertical misfit) = prosthesis presenting total vertical misfit of 100 pm in the platform of the framework in the 2M. A vertical load of 400 N was distributed and applied on 12 centric points by the software Ansys, ie, a vertical load of 150 N was applied to each molar in the prosthesis and a vertical load of 100 N was applied at the 2PM. Results: The stress values and distribution in peri-implant bone tissue were similar for all groups. The models with misfit exhibited different distribution patterns and increased stress magnitude in comparison to the control. The highest stress values in group UAM were observed in the implant body and retention screw. The groups UVM and TVM exhibited high stress values in the platform of the framework and the implant hexagon, respectively. Conclusions: The three types of misfit influenced the magnitude and distribution of stresses. The influence of misfit on peri-implant bone tissue was modest. Each type of misfit increased the stress values in different regions of the system. INT J ORAL MAXILLOFAC IMPLANTS 2011;26:788-796

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The use of implants to rehabilitation of total edentulous, partial edentulous or single tooth is increasing, it is due to the high rate of success that this type of treatment present. The objective of this study was to analyze the mechanical behavior of different positions of two dental implants in a rehabilitation of 4 teeth in the region of maxilla anterior. The groups studied were divided according the positioning of the implants. The Group 1: Internal Hexagonal implant in position of lateral incisors and pontic in region of central incisors; Group 2: Internal Hexagonal implant in position of central incisors and cantilever of the lateral incisors and Group3 - : Internal Hexagonal implants alternate with suspended elements. The Electronic Speckle Pattern Interferometry (ESPI) technique was selected for the mechanical evaluation of the 3 groups performance. The results are shown in interferometric phase maps representing the displacement field of the prosthetic structure.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The purpose of this study was to assess color alteration of the paints used for iris painting in artificial eyes. Five disks of heat cured acrylic resin were confectioned by microwave energy for each paint analyzed, in a total of 40 specimens. Each specimen consisted of a colorless acrylic resin disk and another of equal size, of scleral white colored acrylic resin, with the painting interposed between the two disks. The specimens were submitted to an accelerated aging process in a chamber under ultraviolet radiation for 1,008 hours. To assess color variation, a reflective spectrophotometer was used. The results were statistically analyzed by ANOVA and the Tukey test (p < 0.05). All the paints underwent chromatic alteration. The oil paint presented the highest resistance to accelerated aging.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The aim of the present study was to evaluate the Mini Nutritional Assessment (MNA), the Nutritional Risk Screening (NRS) 2002 and the American Society of Anesthesiologists Physical Status Score (ASA) as predictors of gait status and mortality 6 months after hip fracture. A total of eighty-eight consecutive patients over the age of 65 years with hip fracture admitted to an orthopaedic unit were prospectively evaluated. Within the first 72 h of admission, each patient's characteristics were recorded, and the MNA, the NRS 2002 and the ASA were performed. Gait status and mortality were evaluated 6 months after hip fracture. Of the total patients, two were excluded because of pathological fractures. The remaining eighty-six patients (aged 80·2 (sd 7·3) years) were studied. Among these patients 76·7 % were female, 69·8 % walked with or without support and 12·8 % died 6 months after the fracture. In a multivariate analysis, only the MNA was associated with gait status 6 months after hip fracture (OR 0·773, 95 % CI 0·663, 0·901; P= 0·001). In the Cox regression model, only the MNA was associated with mortality 6 months after hip fracture (hazard ratio 0·869, 95 % CI 0·757, 0·998; P= 0·04). In conclusion, the MNA best predicts gait status and mortality 6 months after hip fracture. These results suggest that the MNA should be included in the clinical stratification of patients with hip fracture to identify and treat malnutrition in order to improve the outcomes.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Pós-graduação em Ciências da Motricidade - IBRC

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The aim of this study was to evaluate the effects that splinting and different lengths of implants have on the stress distribution in implant-supported prostheses by photoelastic analysis. A total of five photoelastic resin models were made with different proposed situations, and 400 load applications were performed for the analysis. Compared with the unitary prosthesis, the splinted implant-supported prosthesis acted favorably in the distribution of stresses and strains to the implant (p < 0.001). The increase in length was a significant factor in the stress distribution (p < 0.05) and, ultimately, the overall reduction in stress. It was concluded that the splinted implant-supported prosthesis behaved better biomechanically compared with the unitary prosthesis.