917 resultados para titanium and zirconium
Resumo:
Various surface treatments of dental implants have been developed in order to ensure anchorage to bone tissue, optimization of the determinants of electronic structure, crystallinity, composition and properties. Coating techniques have been proposed in order tocreate unionbiochemicalable to accelerate the early stages ofbone tissue, combining the positive properties of titanium and its alloys bioactivity of ceramic materials. This paper discusses protocol for handling the SBF coating of titanium alloys. The apatite phase nucleation occurs by immersing the substrate in synthetic solution simulating blood plasma (Simulated Body Fluid). The protocol allows manipulation of the SBF solution to establish guidelines regarding the usestreamlinedand organized to make practical application.
Resumo:
Purpose: In the present work, a susceptibility and efficacy of the Ti–7.5Mo alloy and Ti alloy to bacterial biofilm formation after surface treatment was evaluated. Methods and materials: The alloy Ti–7.5Mo was obtained in arc furnace under an argon atmosphere. Ingots were then homogenized under vacuum at 1100 °C for 86.4 ks to eliminate chemical segregation and after cold worked discs were cutting. Samples were immersed in NaOH aqueous solution (5 M) and treated at 450 °C. Biofilms were grown in Ti–7.5Mo discs immersed in sterile brain heart infusion broth (BHI)containing 5% sucrose, inoculated with microbial suspension (106 cells/ml) and incubated for 5 days. Next, the discs were placed in tubes with sterile physiological solution 0.9% sodium chloride (NaCl) and sonicated for to disperse the biofilms. Tenfold serial dilutions were carried and aliquots seeded in selective agar, which were then incubated for 48 h. Then, the numbers CFU/ml (log 10) were counted and analyzed statistically. Scanning electron microscopy (SEM) on discs with biofilms groups was performed, atomic force microscope (AFM) and contact angle. Results: The results show that there is a 5% difference in bacterial adhesion between pure titanium and Ti–7.5Mo alloy. Conclusion: It was concluded that the greater the roughness, the greater the hydrophilic effect.
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
In heterogeneous catalysis, numerous elements such as titanium and iron have been studied as nanoscale catalysts, but little is known about the use of niobium in nanocatalysis. The nanostructured particles have intrinsic and different physicochemical characteristics with great potential for use in industrial scale. Brazil having the largest known worldwide niobium reserve has the great challenge of creating pioneering technologies with the metal. Biodiesel is an alternative fuel and renewable substitute for regular diesel. Being biodegradable, non-toxic and have CO2 emissions lower than regular diesel, it contributes to the environment and to the independence from oil. The aim of this work was initially synthesize nanoscale particles of niobium pentoxide (Nanospheres, nanorods, nanofibers, nanocubes) from the sol-gel technique. The characterization of different nanoscale structures obtained was performed using different analytical techniques such as x-ray diffraction (XRD) and Scanning Electron Microscopy (SEM). The synthesized nanometer niobium oxide will be used as a heterogeneous catalyst in biodiesel synthesis from commercial soybean oil, checking in detail what the effect of morphology is presented (Nanospheres, nanorods, nanofibers, nanocubes) in the yield of biodiesel synthesis, comparing these results with those already described in literature for the amorphous niobium oxide and other oxide catalysts. The biodiesel obtained was characterized by gas chromatography system equipped with a FID detector
Development of Nanoinjector Devices for Electrospray Ionization - Tandem Mass Spectrometry (ESI-MSn)
Resumo:
In mass spectrometric (MS) systems with electrospray ionization (ESI), the sample can be analyzed coupled to separation systems (such as liquid chromatography or capillary electrophoresis) or simply by direct infusion. The greatest benefit of the type of injection is the possibility of continuous use of small amounts of samples over a long period of time. This extended analysis time allows a complete study of fragmentation by mass spectrometry, which is critical for structure elucidation of new compounds, or when using an ion trap mass analyzer. The injector filled with the sample is placed at the ESI source inlet creating an electric field suitable for the continuous formation of a spray (solvent and sample) and consequently, the gradual and even release of the sample. For the formation of the spray, is necessary that the injector end is metalized. The formation of a bilayer of titanium and gold provided an excellent attachment of the film, resulting in a nanoinjector for ionization/spray formation in the system for MS. The nanoinjectors showed high repeatability and stability over 100 min by continuous sampling with 10 mu L of sample.
Resumo:
An extensive investigation of strontium titanate, SrTiO3 (STO), nanospheres synthesized via a microwave-assisted hydrothermal (MAH) method has been conducted to gain a better insight into thermodynamic, kinetic, and reaction phenomena involved in STO nucleation and crystal growth processes. To this end, quantum chemical modeling based on the density functional theory and periodic super cell models were done. Several experimental techniques were employed to get a deep characterization of structural and optical features of STO nanospheres. A possible formation mechanism was proposed, based on dehydration of titanium and strontium clusters followed by mesoscale transformation and a self-assembly process along an oriented attachment mechanism resulting in spherical like shape. Raman and XANES analysis renders a noncentrosymmetric environment for the octahedral titanium, while infrared and first order Raman modes reveal OH groups which are unsystematically incorporated into uncoordinated superficial sites. These results seem to indicate that the key component is the presence of distorted TiO6 clusters to engender a luminescence property. Analysis of band structure, density Of states, and charge map shows that there is a close relationship among local broken symmetry, polarization, and energy split of the 3d orbitals of titanium. The interplay among these electronic and structural features provides necessary conditions to evaluate its luminescent properties under two energy excitation.
Development of nanoinjector devices for electrospray ionization - tandem mass spectrometry (ESI-MSn)
Resumo:
In mass spectrometric (MS) systems with electrospray ionization (ESI), the sample can be analyzed coupled to separation systems (such as liquid chromatography or capillary electrophoresis) or simply by direct infusion. The greatest benefit of the type of injection is the possibility of continuous use of small amounts of samples over a long period of time. This extended analysis time allows a complete study of fragmentation by mass spectrometry, which is critical for structure elucidation of new compounds, or when using an ion trap mass analyzer. The injector filled with the sample is placed at the ESI source inlet creating an electric field suitable for the continuous formation of a spray (solvent and sample) and consequently, the gradual and even release of the sample. For the formation of the spray, is necessary that the injector end is metalized. The formation of a bilayer of titanium and gold provided an excellent attachment of the film, resulting in a nanoinjector for ionization/spray formation in the system for MS. The nanoinjectors showed high repeatability and stability over 100 min by continuous sampling with 10 µL of sample.
Resumo:
OBJECTIVE: To describe and compare three alternative methods for controlling classical friction: Self-ligating brackets (SLB), special brackets (SB) and special elastomeric ligatures (SEB). METHODS: The study compared Damon MX, Smart Clip, In-Ovation and Easy Clip self-ligating bracket systems, the special Synergy brackets and Morelli's twin bracket with special 8-shaped elastomeric ligatures. New and used Morelli brackets with new and used elastomeric ligatures were used as control. All brackets had 0.022 x 0.028-in slots. 0.014-in nickel-titanium and stainless steel 0.019 x 0.025-in wires were tied to first premolar steel brackets using each archwire ligation method and pulled by an Instron machine at a speed of 0.5 mm/minute. Prior to the mechanical tests the absence of binding in the device was ruled out. Statistical analysis consisted of the Kruskal-Wallis test and multiple non-parametric analyses at a 1% significance level. RESULTS: When a 0.014-in archwire was employed, all ligation methods exhibited classical friction forces close to zero, except Morelli brackets with new and old elastomeric ligatures, which displayed 64 and 44 centiNewtons, respectively. When a 0.019 x 0.025-in archwire was employed, all ligation methods exhibited values close to zero, except the In-Ovation brackets, which yielded 45 cN, and the Morelli brackets with new and old elastomeric ligatures, which displayed 82 and 49 centiNewtons, respectively. CONCLUSIONS: Damon MX, Easy Clip, Smart Clip, Synergy bracket systems and 8-shaped ligatures proved to be equally effective alternatives for controlling classical friction using 0.014-in nickel-titanium archwires and 0.019 x 0.025-in steel archwires, while the In-Ovation was efficient with 0.014-in archwires but with 0.019 x 0.025-in archwires it exhibited friction that was similar to conventional brackets with used elastomeric ligatures.
Resumo:
Adhesive bonding provides solutions to realize cost effective and low weight aircraft fuselage structures, in particular where the Damage Tolerance (DT) is the design criterion. Bonded structures that combine Metal Laminates (MLs) and eventually Selective Reinforcements can guarantee slow crack propagation, crack arrest and large damage capability. To optimize the design exploiting the benefit of bonded structures incorporating selective reinforcement requires reliable analysis tools. The effect of bonded doublers / selective reinforcements is very difficult to be predicted numerically or analytically due to the complexity of the underlying mechanisms and failures modes acting. Reliable predictions of crack growth and residual strength can only be based on sound empirical and phenomenological considerations strictly related to the specific structural concept. Large flat stiffened panels that combine MLs and selective reinforcements have been tested with the purpose of investigating solutions applicable to pressurized fuselages. The large test campaign (for a total of 35 stiffened panels) has quantitatively investigated the role of the different metallic skin concepts (monolithic vs. MLs) of the aluminum, titanium and glass-fiber reinforcements, of the stringers material and cross sections and of the geometry and location of doublers / selective reinforcements. Bonded doublers and selective reinforcements confirmed to be outstanding tools to improve the DT properties of structural elements with a minor weight increase. However the choice of proper materials for the skin and the stringers must be not underestimated since they play an important role as well. A fuselage structural concept has been developed to exploit the benefit of a metal laminate design concept in terms of high Fatigue and Damage Tolerance (F&DT) performances. The structure used laminated skin (0.8mm thick), bonded stringers, two different splicing solutions and selective reinforcements (glass prepreg embedded in the laminate) under the circumferential frames. To validate the design concept a curved panel was manufactured and tested under loading conditions representative of a single aisle fuselage: cyclic internal pressurization plus longitudinal loads. The geometry of the panel, design and loading conditions were tailored for the requirements of the upper front fuselage. The curved panel has been fatigue tested for 60 000 cycles before the introduction of artificial damages (cracks in longitudinal and circumferential directions). The crack growth of the artificial damages has been investigated for about 85 000 cycles. At the end a residual strength test has been performed with a “2 bay over broken frame” longitudinal crack. The reparability of this innovative concept has been taken into account during design and demonstrated with the use of an external riveted repair. The F&DT curved panel test has confirmed that a long fatigue life and high damage tolerance can be achieved with a hybrid metal laminate low weight configuration. The superior fatigue life from metal laminates and the high damage tolerance characteristics provided by integrated selective reinforcements are the key concepts that provided the excellent performances. The weight comparison between the innovative bonded concept and a conventional monolithic riveted design solution showed a significant potential weight saving but the weight advantages shall be traded off with the additional costs.
Resumo:
Die Synthese und Charakterisierung von Bisphenolato-Komplexen des Titans und Vanadiums werden beschrieben.Neben dem Methylkomplex wurde eine Reihe von Bisphenolato-Komplexen des Titan(IV) der Zusammensetzung (tbmp)(o-C6H4CH2NMe2)TiX (mit X = CH2SiMe3, CH2Ph, OTf) synthetisiert. Der Methylkomplex wurde mit B(C6F5)3 oder (tbmp)(tbmpH)Al zum Komplexkation [(tbmp)(o-C6H4CH2NMe2)Ti]+ umgesetzt und dessen Reaktivität gegenüber 1-Olefinen untersucht.Ausgehend von (tbmp)TiCl2 wurden der Dimethylkomplex (tbmp)TiMe2 und der Dibenzylkomplex (tbmp)Ti(CH2Ph)2 dargestellt und strukturell charakterisiert. Der Dibenzylkomplex liegt im Kristall als Dimer vor, verbrückt über ein Dioxan-Molekül, während der Dimethylkomplex auch im Feststoff monomer ist. Dies ist das erste Beispiel für die Koordinationszahl fünf bei Bisphenolato-Titan-Komplexen.Polymerisationsversuche mit (tbmp)TiMe2 und B(C6F5)3 weisen auf eine hohe Reaktivität und geringe Stabilität des aktivierten Komplexes hin, die zu geringen Polymer-Ausbeuten führt.Im Falle des Vanadiums konnten trotz Schwierigkeiten aufgrund der hohen Redoxaktivität dieses Elements mehrere Komplexe dargestellt werden. Synthetisiert und strukturell charakterisiert wurden der Komplex (mbmp)V(O)(CH2SiMe3)·B(C6F5)3, das erste Beispiel für ein Boranaddukt eines Oxokomplexes des fünfwertigen Vanadiums, und der erste Di(bisphenolato)-Komplex des vierwertigen Vanadiums, (tbmp)2V.Desweiteren gelang die Darstellung von (mbmp)V(O)(CH2SiMe2Ph)·B(C6F5)3, (tbmp)VCl(THF)2 und (mbmp)2V. Die Alkylkomplexe des fünfwertigen Vanadiums waren mit B(C6F5)3 für die Polymerisation von Ethen nicht aktivierbar. Hingegen bildete (tbmp)VCl(THF)2 mit DEAC ein sehr aktives System für die Polymerisation von Ethen.
Resumo:
Ziel der Arbeit war es, festzustellen, inwieweit die Bestimmung der Konzentrationen und der Isotopenverhältnisse verschiedener Elemente in humanbiologischen Materialien dazu geeignet ist, Informationen über Herkunft und Wohnort oder zurückliegende Ortswechsel einer Person aufzuzeigen. Dieses Forschungsprojekt wurde in Zusammenarbeit mit dem Bundeskriminalamt Wiesbaden durchgeführt. Dort werden in dem seit 2008 laufenden Projekt „Isohaar“ vor allem Haare, aber auch Fingernägel, von Personen vor, während und nach einer Auslandsreise gesammelt. An diesen Materialien sollte überprüft werden, ob ein Ortswechsel Einfluss auf die Elementgehalte und/oder Isotopenverhältnisse hat.rnAls elementanalytische Methoden wurden die Neutronenaktivierungsanalyse (NAA) und die induktiv gekoppeltes Plasma-Massenspektrometrie (ICP-MS) an flüssigen Aufschlüssen der Proben, sowie direkt an den Proben mittels Laser Ablation (LA-ICP-MS) erprobt. Die Isotopenverhältnisse der Elemente Kohlenstoff und Stickstoff wurden mittels Isotopenverhältnis-Massenspektrometrie (IRMS) bestimmt, die der schweren Elemente Strontium und Blei mittels Thermionen-Massenspektrometrie (TIMS).rnMittels Flüssig-ICP-MS wurde ein Konzentrationsanstieg für einige Elemente (z.B. Na, Mg Ba, Cu, Sr und Ca) vom Haaransatz (jüngster Haarabschnitt) zur Haarspitze (ältester Haarabschnitt) einer analysierten Strähne gefunden. Die Spender dieser Proben hatten keinen Ortswechsel vollzogen. Bei Haarproben von Personen, die einen Aufenthaltsortswechsel erlebt hatten, zeigten sich markante Konzentrationserhöhungen bei Eisen, Mangan, Titan und Blei in den betreffenden Abschnitten. Diese Elemente scheinen evtl. das Potential zu haben, Ortswechsel anzuzeigen.rnBei den Isotopenverhältnissen von Kohlenstoff und Stickstoff konnten einige Unterschiede zwischen verschiedenen Aufenthaltsorten einer Person gefunden werden. Diese Änderungen werden mit der häufig unausweichlichen unterschiedlichen Ernährungsweise des Haarspenders bei Reisen in Zusammenhang gebracht. Die Isotopenverhältnisse von Strontium und Blei konnten bisher nicht einem bestimmten Land oder einer Region zugeordnet werden. Die Proben zwischen den einzelnen Teilnehmern unterschieden sich jedoch. rnFür die Zukunft sollte versucht werden, die Ergebnisse der Analysenmethoden miteinander zu kombinieren, um aussagekräftigere Hinweise auf einen möglichen Ortswechsel zu erhalten.rn
Resumo:
OBJECTIVE To compare the precision of fit of long-span vs. short-span implant-supported screw-retained fixed dental prostheses (FDPs) made from computer-aided-design/computer-aided-manufactured (CAD/CAM) titanium and veneered with ceramic. The null hypothesis was that there is no difference in the vertical microgap between long-span and short-span FDPs. MATERIALS AND METHODS CAD/CAM titanium frameworks for an implant-supported maxillary FDP on implants with a flat platform were fabricated on one single master cast. Group A consisted of six 10-unit FDPs connected to six implants (FDI positions 15, 13, 11, 21, 23, 25) and group B of six 5-unit FDPs (three implants, FDI positions 21, 23, 25). The CAD/CAM system from Biodenta Swiss AG (Berneck, Switzerland) was used for digitizing (laser scanner) the master cast and anatomical CAD of each framework separately. The frameworks were milled (CAM) from a titanium grade V monobloc and veneered with porcelain. Median vertical distance between implant and FDP platforms from the non-tightened implants (one-screw test on implant 25) was calculated from mesial, buccal, and distal scanning electron microscope measurements. RESULTS All measurements showed values <40 μm. Total median vertical microgaps were 23 μm (range 2-38 μm) for group A and 7 μm (4-24 μm) for group B. The difference between the groups was statistically significant at implant 21 (P = 0.002; 97.5% CI -27.3 to -4.9) and insignificant at implant 23 (P = 0.093; -3.9 to 1.0). CONCLUSIONS CAD/CAM fabrication including laboratory scanning and porcelain firing was highly precise and reproducible for all long- and short-span FDPs. While all FDPs showed clinically acceptable values, the short-span FDPs were statistically more precise at the 5-unit span distance.
Resumo:
In three typical sandy soils of Northern Germany the mobility of radioactive fission products of technetium, iodine, ruthenium and zirconium have been investigated in dependence of the hydrodynamic and physico-chemical soil properties. The laboratory experiments, which simulated fall-out events, used soil columns (1 m length, 30 cm diameter) taken as undisturbed as possible. By measurements of the breakthrough curves in the percolate and of the depth distribution of radionuclides in the soil columns after 6 months the average transport velocity could be determined. These values could be compared with the average water velocity measured by 3H tagging. Three qualitative mobility relations were observed: Ranker: Tc > Ru > I > Zr; Podsol: Tc > Ru > I > Zr; Brown forest soil: Tc = Ru > I > Zr. Relations between some physico-chemical soil properties and the retardation of radionuclides due to adsorption could be observed (eg. retardation of iodine and technetium by organic substances). The average retardation factors of the radionuclides and the hydrodynamic soil parameters are used in a model which gives a quantitative assessment of the hazard of groundwater contamination by a fall-out event in areas covered with comparable soils.