956 resultados para remote diagnostics of electric drives
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
The paper describes the preliminary studies of University of Minho on the use of Electric Impedance/Resistance Tomography to assess masonry structures. The study is focused on the analysis of values of current and voltage resulting from the use of an electrical source with voltage and frequency values from a distribution network. The analysis is made from results obtained through computer simulations, using a three-dimensional model of the idealized masonry structures. A finite element program was used for the simulations. Three types of electrodes were used in simulations, and the analysis of the results led to significant conclusions. Later masonry specimens were built and a series of preliminary tests were carried out in the laboratory. The comparative analysis of simulated and experimental results allowed identifying the factors that have influence on the physical results.
Resumo:
Full validation of the electrochemical mechanisms so far postulated as driving force of electric field-assisted non-spontaneous crystallization development in given glasses has suffered experimental restrictions. In this work, we looked into origin of this phenomenon in lead oxyfluoroborate glasses, resulting in beta-PbF2 growth even below the corresponding glass transition temperatures, through achieving a systematic study of not only Pt,Ag/Glass/Ag,Pt- but also Pt,Ag/Glass/YSZ:PbF2/Ag,Pt-type cells, where YSZ:PbF2 represents a two-phase system (formed by Y2O3-doped ZrO2 and PbF2). It is demonstrated that crystallization induction in these glasses involves Pb2+ ions reduction at the cathode, the phenomenon being, however, confirmed only when the F- ions were simultaneously also able to reach the anode for oxidation, after assuring either a direct glass-anode contact or percolation pathways for free fluoride migration across the YSZ:PbF2 mixtures. A further support of this account is that the electrochemically induced beta-PbF2 phase crystallizes showing ramified-like microstructure morphology that arises, accordingly, from development of electroconvective diffusion processes under electric field action.
Modelling, diagnostics and experimental analysis of plasma assisted processes for material treatment
Resumo:
This work presents results from experimental investigations of several different atmospheric pressure plasmas applications, such as Metal Inert Gas (MIG) welding and Plasma Arc Cutting (PAC) and Welding (PAW) sources, as well as Inductively Coupled Plasma (ICP) torches. The main diagnostic tool that has been used is High Speed Imaging (HSI), often assisted by Schlieren imaging to analyse non-visible phenomena. Furthermore, starting from thermo-fluid-dynamic models developed by the University of Bologna group, such plasma processes have been studied also with new advanced models, focusing for instance on the interaction between a melting metal wire and a plasma, or considering non-equilibrium phenomena for diagnostics of plasma arcs. Additionally, the experimental diagnostic tools that have been developed for industrial thermal plasmas have been used also for the characterization of innovative low temperature atmospheric pressure non equilibrium plasmas, such as dielectric barrier discharges (DBD) and Plasma Jets. These sources are controlled by few kV voltage pulses with pulse rise time of few nanoseconds to avoid the formation of a plasma arc, with interesting applications in surface functionalization of thermosensitive materials. In order to investigate also bio-medical applications of thermal plasma, a self-developed quenching device has been connected to an ICP torch. Such device has allowed inactivation of several kinds of bacteria spread on petri dishes, by keeping the substrate temperature lower than 40 degrees, which is a strict requirement in order to allow the treatment of living tissues.
Resumo:
The subject of this study is to investigate the capability of spaceborne remote sensing data to predict ground concentrations of PM10 over the European Alpine region using satellite derived Aerosol Optical Depth (AOD) from the geostationary Spinning Enhanced Visible and InfraRed Imager (SEVIRI) and the polar-orbiting MODerate resolution Imaging Spectroradiometer (MODIS). The spatial and temporal resolutions of these aerosol products (10 km and 2 measurements per day for MODIS, ∼ 25 km and observation intervals of 15 min for SEVIRI) permit an evaluation of PM estimation from space at different spatial and temporal scales. Different empirical linear relationships between coincident AOD and PM10 observations are evaluated at 13 ground-based PM measurement sites, with the assumption that aerosols are vertically homogeneously distributed below the planetary Boundary Layer Height (BLH). The BLH and Relative Humidity (RH) variability are assessed, as well as their impact on the parameterization. The BLH has a strong influence on the correlation of daily and hourly time series, whilst RH effects are less clear and smaller in magnitude. Despite its lower spatial resolution and AOD accuracy, SEVIRI shows higher correlations than MODIS (rSEV∼ 0.7, rMOD∼ 0.6) with regard to daily averaged PM10. Advantages from MODIS arise only at hourly time scales in mountainous locations but lower correlations were found for both sensors at this time scale (r∼ 0.45). Moreover, the fraction of days in 2008 with at least one satellite observation was 27% for SEVIRI and 17% for MODIS. These results suggest that the frequency of observations plays an important role in PM monitoring, while higher spatial resolution does not generally improve the PM estimation. Ground-based Sun Photometer (SP) measurements are used to validate the satellite-based AOD in the study region and to discuss the impact of aerosols' micro-physical properties in the empirical models. A lower error limit of 30 to 60% in the PM10 assessment from space is estimated in the study area as a result of AOD uncertainties, variability of aerosols properties and the heterogeneity of ground measurement sites. It is concluded that SEVIRI has a similar capacity to map PM as sensors on board polar-orbiting platforms, with the advantage of a higher number of observations. However, the accuracy represents a serious limitation to the applicability of satellites for ground PM mapping, especially in mountainous areas.
Resumo:
Energy crisis and worldwide environmental problem make hydrogen a prospective energy carrier. However, storage and transportation of hydrogen in large quantities at small volume is currently not practical. Lots of materials and devices have been developed for storage hydrogen, but to today none is able to meet the DOE targets. Activated carbon has been found to be a good hydrogen adsorbent due to its high surface area. However, the weak van der Waals force between hydrogen and the adsorbent has limited the adsorption capacity. Previous studies have found that enhanced adsorption can be obtained with applied electric field. Stronger interaction between the polarized hydrogen and the charged sorbents under high voltage is considered as the reason. This study was initiated to investigate if the adsorption can be further enhanced when the activated carbon particles are separated with a dielectric coating. Dielectric TiO2 nanoparticles were first utilized. Hydrogen adsorption measurements on the TiO2-coated carbon materials, with or without an external electric field, were made. The results showed that the adsorption capacity enhancement increased with the increasing amount of TiO2 nanoparticles with an applied electric field. Since the hydrogen adsorption capacity on TiO2 particles is very low and there is no hydrogen adsorption enhancement on TiO2 particles alone when electric field is applied, the effect of dielectric coating is demonstrated. Another set of experiments investigated the behavior of hydrogen adsorption over TiO2-coated activated carbon under various electric potentials. The results revealed that the hydrogen adsorption first increased and then decreased with the increase of electric field. The improved storage was due to a stronger interaction between charged carbon surface and polarized hydrogen molecule caused by field induced polarization of TiO2 coating. When the electric field was sufficient to cause considerable ionization of hydrogen, the decrease of hydrogen adsorption occurred. The current leak detected at 3000 V was a sign of ionization of hydrogen. Experiments were also carried out to examine the hydrogen adsorption performances over activated carbon separated by other dielectric materials, MgO, ZnO and BaTiO3, respectively. For the samples partitioned with MgO and ZnO, the measurements with and without an electric field indicated negligible differences. Electric field enhanced adsorption has been observed on the activated carbon separated with BaTiO3, a material with unusually high dielectric constant. Corresponding computational calculations using Density Functional Theory have been performed on hydrogen interaction with charged TiO2 molecule as well as TiO2 molecule, coronene and TiO2-doped coronene in the presence of an electric field. The simulated results were consistent with the observations from experiments, further confirming the proposed hypotheses.
Resumo:
This thesis will present strategies for the use of plug-in electric vehicles on smart and microgrids. MATLAB is used as the design tool for all models and simulations. First, a scenario will be explored using the dispatchable loads of electric vehicles to stabilize a microgrid with a high penetration of renewable power generation. Grid components for a microgrid with 50% photovoltaic solar production will be sized through an optimization routine to maintain storage system, load, and vehicle states over a 24-hour period. The findings of this portion are that the dispatchable loads can be used to guard against unpredictable losses in renewable generation output. Second, the use of distributed control strategies for the charging of electric vehicles utilizing an agent-based approach on a smart grid will be studied. The vehicles are regarded as additional loads to a primary forecasted load and use information transfer with the grid to make their charging decisions. Three lightweight control strategies and their effects on the power grid will be presented. The findings are that the charging behavior and peak loads on the grid can be reduced through the use of distributed control strategies.
Resumo:
The RPC developed a new phantom to ensure comparable and consistent radiation administration in spinal radiosurgery clinical trials. This study assessed the phantom’s dosimetric and anatomic utility. The ‘spine phantom’ is a water filled thorax with anatomy encountered in spinal radiosurgery: target volume, vertebral column, spinal canal, esophagus, heart, and lungs. The dose to the target volume was measured with axial and sagittal planes of radiochromic film and thermoluminescent dosimeters (TLD). The dose distributions were measured with the radiochromic film calibrated to the absolute dose measured by the TLD. Four irradiations were administered: a four angle box plan, a seven angle conformal plan, a seven angle IMRT plan, and a nine angle IMRT plan (denoted as IMRT plan #1 and plan #2, respectively). In each plan, at least 95% of the defined tumor volume received 8 Gy. For each irradiation the planned and administered dose distributions were registered via pinpricks, and compared using point dose measurements, dose profiles, isodose distributions, and gamma analyses. Based on previous experience at the RPC, a gamma analysis was considering passing if greater than 95% of pixels passed the criteria of 5% dose difference and 3 mm distance-to-agreement. Each irradiation showed acceptable agreement in the qualitative assessments and exceeded the 95% passing rate at the 5% / 3 mm criteria, except IMRT plan #1, which was determined to have been poorly localized during treatment administration. The measured and planned dose distributions demonstrated acceptable agreement at the 5% / 3 mm criteria, and the spine phantom was determined to be a useful tool for the remote assessment of an institution’s treatment planning and dose delivery regimen.
Resumo:
Distribution, accumulation and diagenesis of surficial sediments in coastal and continental shelf systems follow complex chains of localized processes and form deposits of great spatial variability. Given the environmental and economic relevance of ocean margins, there is growing need for innovative geophysical exploration methods to characterize seafloor sediments by more than acoustic properties. A newly conceptualized benthic profiling and data processing approach based on controlled source electromagnetic (CSEM) imaging permits to coevally quantify the magnetic susceptibility and the electric conductivity of shallow marine deposits. The two physical properties differ fundamentally insofar as magnetic susceptibility mostly assesses solid particle characteristics such as terrigenous or iron mineral content, redox state and contamination level, while electric conductivity primarily relates to the fluid-filled pore space and detects salinity, porosity and grain-size variations. We develop and validate a layered half-space inversion algorithm for submarine multifrequency CSEM with concentric sensor configuration. Guided by results of modeling, we modified a commercial land CSEM sensor for submarine application, which was mounted into a nonconductive and nonmagnetic bottom-towed sled. This benthic EM profiler Neridis II achieves 25 soundings/second at 3-4 knots over continuous profiles of up to hundred kilometers. Magnetic susceptibility is determined from the 75 Hz in-phase response (90% signal originates from the top 50 cm), while electric conductivity is derived from the 5 kHz out-of-phase (quadrature) component (90% signal from the top 92 cm). Exemplary survey data from the north-west Iberian margin underline the excellent sensitivity, functionality and robustness of the system in littoral (~0-50 m) and neritic (~50-300 m) environments. Susceptibility vs. porosity cross-plots successfully identify known lithofacies units and their transitions. All presently available data indicate an eminent potential of CSEM profiling for assessing the complex distribution of shallow marine surficial sediments and for revealing climatic, hydrodynamic, diagenetic and anthropogenic factors governing their formation.
Resumo:
This paper presents an analysis of the transport of electric current in a jet of an electrically conducting liquid discharging from a metallic tube into a gas or a vacuum, and subject to an electric field due to a high voltage applied between the tube and a far electrode. The flow, the surface charge and the electric field are computed in the current transfer region of the jet, where conduction current in the liquid becomes surface current due to the convection of electric charge accumulated at its surface. The electric current computed as a function of the flow rate of the liquid injected through the tube increases first as the square root of this flow rate, levels to a nearly constant value when the flow rate is increased and finally sets to a linear increase when the flow rate is further increased. The current increases linearly with the applied voltage at small and moderate values of this variable, and faster than linearly at high voltages. The characteristic length and structure of the current transfer region are determined. Order-of-magnitude estimates for jets which are only weakly stretched by the electric stresses are worked out that qualitatively account for some of the numerical results.
Resumo:
This paper describes the experiences using remote laboratories for thorough analysis of a thermal system, including disturbances. Remote laboratories for education in subjects of control, is a common resorted method, used by universities. This method is applied to offer a flexible service in schedules so as to obtain greater and better results of available resources. Remote laboratories have been used for controlling physical devices remotely. Furthermore, remote labs have been used for transfer function identification of real equipment. Nevertheless, remote analyses of disturbances have not been done. The aim of this contribution is thereby to apply the experience of remote laboratories in the study of disturbances. Some experiments are carried out to demonstrate the effectiveness in using remote laboratories for complete analysis of a thermal system. Considering the remote access to thermal system, “Sistema de Laboratorios a Distancia” (SLD) was used.
Resumo:
Con 1.300 millones de personas en el mundo sin acceso a la electricidad (la mayoría en entornos rurales de países empobrecidos), la energía solar fotovoltaica constituye una solución viable técnica y económicamente para electrificar las zonas más remotas del planeta donde las redes eléctricas convencionales no llegan. Casi todos los países en el mundo han desarrollado algún tipo de programa de electrificación fotovoltaica rural durante los últimos 40 años, principalmente los países más pobres, donde a través de diferentes modelos de financiación, se han instalado millones de sistemas solares domiciliarios (pequeños sistemas fotovoltaicos para uso doméstico). Durante este largo período, se han ido superando muchas barreras, como la mejora de la calidad de los sistemas fotovoltaicos, la reducción de costes, la optimización del diseño y del dimensionado de los sistemas, la disponibilidad financiera para implantar programas de electrificación rural, etc. Gracias a esto, la electrificación rural descentralizada ha experimentado recientemente un salto de escala caracterizada por la implantación de grandes programas con miles de sistemas solares domiciliarios e integrando largos períodos de mantenimiento. Muchos de estos grandes programas se están llevando a cabo con limitado éxito, ya que generalmente parten de supuestos e hipótesis poco contrastadas con la realidad, comprometiendo así un retorno económico que permita el desarrollo de esta actividad a largo plazo. En este escenario surge un nuevo reto: el de cómo garantizar la sostenibilidad de los grandes programas de electrificación rural fotovoltaica. Se argumenta que la principal causa de esta falta de rentabilidad es el imprevisto alto coste de la fase de operación y mantenimiento. Cuestiones clave tales como la estructura de costes de operación y mantenimiento o la fiabilidad de los componentes del sistema fotovoltaico no están bien caracterizados hoy en día. Esta situación limita la capacidad de diseñar estructuras de mantenimiento capaces de asegurar la sostenibilidad y la rentabilidad del servicio de operación y mantenimiento en estos programas. Esta tesis doctoral tiene como objetivo responder a estas cuestiones. Se ha realizado varios estudios sobre la base de un gran programa de electrificación rural fotovoltaica real llevado a cabo en Marruecos con más de 13.000 sistemas solares domiciliarios instalados. Sobre la base de este programa se ha hecho una evaluación en profundidad de la fiabilidad de los sistemas solares a partir de los datos de mantenimiento recogidos durante 5 años con más de 80.000 inputs. Los resultados han permitido establecer las funciones de fiabilidad de los equipos tal y como se comportan en condiciones reales de operación, las tasas de fallos y los tiempos medios hasta el fallo para los principales componentes del sistema, siendo este el primer caso de divulgación de resultados de este tipo en el campo de la electrificación rural fotovoltaica. Los dos principales componentes del sistema solar domiciliario, la batería y el módulo fotovoltaico, han sido analizados en campo a través de una muestra de 41 sistemas trabajando en condiciones reales pertenecientes al programa solar marroquí. Por un lado se ha estudiado la degradación de la capacidad de las baterías y por otro la degradación de potencia de los módulos fotovoltaicos. En el caso de las baterías, los resultados nos han permitido caracterizar la curva de degradación en capacidad llegando a obtener una propuesta de nueva definición del umbral de vida útil de las baterías en electrificación rural. También sobre la base del programa solar de Marruecos se ha llevado a cabo un estudio de caracterización de los costes reales de operación y mantenimiento a partir de la base de datos de contabilidad del programa registrados durante 5 años. Los resultados del estudio han permitido definir cuáles son costes que más incidencia tienen en el coste global. Se han obtenido los costes unitarios por sistema instalado y se han calculado los montantes de las cuotas de mantenimiento de los usuarios para garantizar la rentabilidad de la operación y mantenimiento. Finalmente, se propone un modelo de optimización matemática para diseñar estructuras de mantenimiento basado en los resultados de los estudios anteriores. La herramienta, elaborada mediante programación lineal entera mixta, se ha aplicado al programa marroquí con el fin de validar el modelo propuesto. ABSTRACT With 1,300 million people worldwide deprived of access to electricity (mostly in rural environments), photovoltaic solar energy has proven to be a cost‐effective solution and the only hope for electrifying the most remote inhabitants of the planet, where conventional electric grids do not reach because they are unaffordable. Almost all countries in the world have had some kind of rural photovoltaic electrification programme during the past 40 years, mainly the poorer countries, where through different organizational models, millions of solar home systems (small photovoltaic systems for domestic use) have been installed. During this long period, many barriers have been overcome, such as quality enhancement, cost reduction, the optimization of designing and sizing, financial availability, etc. Thanks to this, decentralized rural electrification has recently experienced a change of scale characterized by new programmes with thousands of solar home systems and long maintenance periods. Many of these large programmes are being developed with limited success, as they have generally been based on assumptions that do not correspond to reality, compromising the economic return that allows long term activity. In this scenario a new challenge emerges, which approaches the sustainability of large programmes. It is argued that the main cause of unprofitability is the unexpected high cost of the operation and maintenance of the solar systems. In fact, the lack of a paradigm in decentralized rural services has led to many private companies to carry out decentralized electrification programmes blindly. Issues such as the operation and maintenance cost structure or the reliability of the solar home system components have still not been characterized. This situation does not allow optimized maintenance structure to be designed to assure the sustainability and profitability of the operation and maintenance service. This PhD thesis aims to respond to these needs. Several studies have been carried out based on a real and large photovoltaic rural electrification programme carried out in Morocco with more than 13,000 solar home systems. An in‐depth reliability assessment has been made from a 5‐year maintenance database with more than 80,000 maintenance inputs. The results have allowed us to establish the real reliability functions, the failure rate and the main time to failure of the main components of the system, reporting these findings for the first time in the field of rural electrification. Both in‐field experiments on the capacity degradation of batteries and power degradation of photovoltaic modules have been carried out. During the experiments both samples of batteries and modules were operating under real conditions integrated into the solar home systems of the Moroccan programme. In the case of the batteries, the results have enabled us to obtain a proposal of definition of death of batteries in rural electrification. A cost assessment of the Moroccan experience based on a 5‐year accounting database has been carried out to characterize the cost structure of the programme. The results have allowed the major costs of the photovoltaic electrification to be defined. The overall cost ratio per installed system has been calculated together with the necessary fees that users would have to pay to make the operation and maintenance affordable. Finally, a mathematical optimization model has been proposed to design maintenance structures based on the previous study results. The tool has been applied to the Moroccan programme with the aim of validating the model.
Resumo:
All around the ITER vacuum vessel, forty-four ports will provide access to the vacuum vessel for remotehandling operations, diagnostic systems, heating, and vacuum systems: 18 upper ports, 17 equatorialports, and 9 lower ports. Among the lower ports, three of them will be used for the remote handlinginstallation of the ITER divertor. Once the divertor is in place, these ports will host various diagnosticsystems mounted in the so-called diagnostic racks. The diagnostic racks must allow the support andcooling of the diagnostics, extraction of the required diagnostic signals, and providing access and main-tainability while minimizing the leakage of radiation toward the back of the port where the humans areallowed to enter. A fully integrated inner rack, carrying the near plasma diagnostic components, will bean stainless steel structure, 4.2 m long, with a maximum weight of 10 t. This structure brings water forcooling and baking at maximum temperature of 240?C and provides connection with gas, vacuum andelectric services. Additional racks (placed away from plasma and not requiring cooling) may be requiredfor the support of some particular diagnostic components. The diagnostics racks and its associated exvessel structures, which are in its conceptual design phase, are being designed to survive the lifetimeof ITER of 20 years. This paper presents the current state of development including interfaces, diagnos-tic integration, operation and maintenance, shielding requirements, remote handling, loads cases anddiscussion of the main challenges coming from the severe environment and engineering requirements.
Resumo:
Application of electric fields tangent to the plane of a confined patch of fluid bilayer membrane can create lateral concentration gradients of the lipids. A thermodynamic model of this steady-state behavior is developed for binary systems and tested with experiments in supported lipid bilayers. The model uses Flory’s approximation for the entropy of mixing and allows for effects arising when the components have different molecular areas. In the special case of equal area molecules the concentration gradient reduces to a Fermi–Dirac distribution. The theory is extended to include effects from charged molecules in the membrane. Calculations show that surface charge on the supporting substrate substantially screens electrostatic interactions within the membrane. It also is shown that concentration profiles can be affected by other intermolecular interactions such as clustering. Qualitative agreement with this prediction is provided by comparing phosphatidylserine- and cardiolipin-containing membranes.
Resumo:
"ILENR/CD-87/02."