763 resultados para intraocular lens
Resumo:
AIM To assess the effects of eye rubbing on corneal thickness (CT) and intraocular pressure (IOP) measurements obtained 0-30min after habitual eye rubbing in symptomatic patients. METHODS Measurements of IOP and CT were obtained at five locations (central, temporal, superior, nasal and inferior) before, and every 5min for 30min interval after 30s of eye rubbing, for 25 randomly selected eyes of 14 subjects with ocular allergy and 11 age-matched normals. Differences in measurements were calculated in each group [Baseline measurements minus measurements recorded at each time interval after eye rubbing (for IOP), and for each corneal location (for CT)] and comparison were then made between groups (allergic versus control) for differences in any observed effects. RESULTS Within groups, baseline mean IOPs in the allergic patient-group (14.2±3.0 mm Hg) and in the control group (13.1±1.9 mm Hg) were similar at all times, after eye rubbing (P >0.05, for all). The maximum reduction in IOP was 0.8 mm Hg in the control subjects and the maximum increase was also 0.8 mm Hg in the allergic subjects. Between groups (allergic versus control), the changes in IOP remained under 1 mm Hg at all times (P=0.2) after 30min of eye rubbing. Between 0 and 30min of CT measurements after eye rubbing, the mean central CT (CCT), inferior CT (ICT), superior CT (SCT), temporal CT (TCT) and nasal CT (NCT) did not vary significantly from baseline values in the control and allergic-subject groups (P>0.05, for both). Between both groups, changes in CT were similar at all locations (P>0.05) except for the TC which was minimally thinner by about 4.4 µm (P=0.001) in the allergic subjects than in the control subjects, 30min following 30s of eye rubbing. CONCLUSION IOP measured in allergic subjects after 30s of habitual eye rubbing was comparable with that obtained in normal subjects at all times between 0 and 30min. Although, CT in the allergic subjects were similar to those of the control subjects at all times, it varied between +10 and -7.5 µm following eye rubbing, with the temporal cornea showing consistent reductions in thickness in the subjects with allergy. However, this reduction was minimal and was considered to not be clinically relevant.
Resumo:
While Jonathan Silin's ideas have challenged early childhood educators to think seriously about the relationship between developmentalism and revisioning early education, they have done much more than this. They also challenge us to know who we are and how our identities might be enacted in our teacher-selves, whether in the classroom with young children, teacher education students or engaging professionally with teachers. In doing so he shows how to resist injustice and unmasks ways in which institutions function in society to marginalise and exclude.
Resumo:
We sought to evaluate central corneal thickness (CCT), corneal endothelial cell density (ECD) and intraocular pressure (IOP) in patients with type 2 diabetes mellitus (DM) and to associate potential differences with diabetes duration and treatment modality in a prospective, randomized study. We measured ECD, CCT and IOP of 125 patients with type 2 DM (mean age 57.1¡11.5 years) and compared them with 90 age-matched controls. Measured parameters were analyzed for association with diabetes duration and glucose control modalities (insulin injection or oral medication) while controlling for age. In the diabetic group, the mean ECD (2511¡252 cells/mm2), mean CCT (539.7¡33.6 mm) and mean IOP (18.3¡2.5 mmHg) varied significantly from those the control group [ECD: 2713¡132 cells/mm2 (P,0.0001), CCT: 525.0¡45.3 mm (P50.003) and IOP: 16.7¡1.8 mmHg (P,0.0001)]. ECD was significantly reduced by about 32 cell/mm2 for diabetics with duration of .10 years when compared with those with duration of ,10 years (P,0.05). CCT was thicker and IOP was higher for diabetics with duration of .10 years than those with duration of ,10 years (P.0.05). None of the measured parameters was significantly associated with diabetes duration and treatment modality (P.0.05). In conclusion, subjects with type 2 DM exhibit significant changes in ECD, IOP and CCT, which, however, are not correlated with disease duration or if the patients receive on insulin injection or oral medications.
Resumo:
Changes to the redox status of biological systems have been implicated in the pathogenesis of a wide variety of disorders including cancer, Ischemia-reperfusion (I/R) injury and neurodegeneration. In times of metabolic stress e.g. ischaemia/reperfusion, reactive oxygen species (ROS) production overwhelms the intrinsic antioxidant capacity of the cell, damaging vital cellular components. The ability to quantify ROS changes in vivo, is therefore essential to understanding their biological role. Here we evaluate the suitability of a novel reversible profluorescent probe containing a redox-sensitive nitroxide moiety (methyl ester tetraethylrhodamine nitroxide, ME-TRN), as an in vivo, real-time reporter of retinal oxidative status. The reversible nature of the probe's response offers the unique advantage of being able to monitor redox changes in both oxidizing and reducing directions in real time. After intravitreal administration of the ME-TRN probe, we induced ROS production in rat retina using an established model of complete, acute retinal ischaemia followed by reperfusion. After restoration of blood flow, retinas were imaged using a Micron III rodent fundus fluorescence imaging system, to quantify the redox-response of the probe. Fluorescent intensity declined during the first 60 min of reperfusion. The ROS-induced change in probe fluorescence was ameliorated with the retinal antioxidant, lutein. Fluorescence intensity in non-Ischemia eyes did not change significantly. This new probe and imaging technology provide a reversible and real-time response to oxidative changes and may allow the in vivo testing of antioxidant therapies of potential benefit to a range of diseases linked to oxidative stress
Resumo:
Early Childhood Education (ECE) has a long history of building foundations for children to achieve their full potential, enabling parents to participate in the economy while children are cared for, addressing poverty and disadvantage, and building individual, community and societal resources. In so doing, ECE has developed a set of cultural practices and ways of knowing that shape the field and the people who work within it. ECE, consequently, is frequently described as unique and special (Moss, 2006; Penn, 2011). This works to define and distinguish the field while, simultaneously, insulating it from other contexts, professions, and ideas. Recognising this dualism illuminates some of the risks and challenges of operating in an insular and isolated fashion. In the 21st century, there are new challenges for children, families and societies to which ECE must respond if it is to continue to be relevant. One major issue is how ECE contributes to transition towards more sustainable ways of living. Addressing this contemporary social problem is one from which Early Childhood teacher education has been largely absent (Davis & Elliott, 2014), despite the well recognised but often ignored role of education in contributing to sustainability. Because of its complexity, sustainability is sometimes referred to as a ‘wicked problem’ (Rittel & Webber, 1973; Australian Public Service Commission, 2007) requiring alternatives to ‘business as usual’ problem solving approaches. In this chapter, we propose that addressing such problems alongside disciplines other than Education enables the Early Childhood profession to have its eyes opened to new ways of thinking about our work, potentially liberating us from the limitations of our “unique” and idiosyncratic professional cultures. In our chapter, we focus on understandings of culture and diversity, looking to broaden these by exploring the different ‘cultures’ of the specialist fields of ECE and Design (in this project, we worked with students studying Architecture, Industrial Design, Landscape Architecture and Interior Design). We define culture not as it is typically represented, i.e. in relation to ideas and customs of particular ethnic and language groups, but to the ideas and practices of people working in different disciplines and professions. We assert that different specialisms have their own ‘cultural’ practices. Further, we propose that this kind of theoretical work helps us to reconsider ways in which ECE might be reframed and broadened to meet new challenges such as sustainability and as yet unknown future challenges and possibilities. We explore these matters by turning to preservice Early Childhood teacher education (in Australia) as a context in which traditional views of culture and diversity might be reconstructed. We are looking to push our specialist knowledge boundaries and to extend both preservice teachers and academics beyond their comfort zones by engaging in innovative interdisciplinary learning and teaching. We describe a case study of preservice Early Childhood teachers and designers working in collaborative teams, intersecting with a ‘real-world’ business partner. The joint learning task was the design of an early learning centre based on sustainable design principles and in which early Education for Sustainability (EfS) would be embedded Data were collected via focus group and individual interviews with students in ECE and Design. Our findings suggest that interdisciplinary teaching and learning holds considerable potential in dismantling taken-for-granted cultural practices, such that professional roles and identities might be reimagined and reconfigured. We conclude the chapter with provocations challenging the ways in which culture and diversity in the field of ECE might be reconsidered within teacher education.
Resumo:
To discover quantitative trait loci for intraocular pressure, amajor risk factor for glaucoma and the only modifiable one,weperformed agenome-wide association studyonadiscoverycohort of2175individualsfromSydney, Australia. We found a novel association between intraocular pressure and a common variant at 7p21 near to GLCCI1 and ICA1. The findings in this region were confirmed through two UK replication cohorts totalling 4866 individuals (rs59072263, Pcombined = 1.10 × 10-8). A copy of the G allele at this SNP is associated with an increase in mean IOP of 0.45 mmHg (95%CI = 0.30-0.61 mmHg). These results lend support to the implication of vesicle trafficking and glucocorticoid inducibility pathways in the determination of intraocular pressure and in the pathogenesis of primary open-angle glaucoma.
Resumo:
Ultraviolet (UV) radiation is one of the major risk factors of cataract (loss of eye-lens transparency). The influence of UVB radiation (300 nm, 100 mu W cm(-2)) on the activity and apparent kinetic constants (K-m and V-max) of rat lens hexokinase (HK;EC2.7.1.1), phosphofructokinase (PFK;EC2.7.1.11), isocitrate dehydrogenase (ICDH;EC1.1.1.41) and malate dehydrogenase (MDH;EC1.1.1.37) of energy metabolism has been investigated by irradiating the lens homogenate of three-and 12-month-old rats. In the three-month-old group specific activities of HK and PFK are reduced by 56 and 43 %, respectively, and there is no change in ICDH and MDH activities after a 24 h exposure. On the other hand, in the 12-month-old group the decreases are 72, 71, 24 and 16 % for HK, PFK. ICDH and MDH, respectively. UVB irradiation increases the apparent K-m of HK and PFK (in both age groups), whereas the K-m of ICDH and MDH is not altered. While the decrease in V-max of these enzymes due to UVB exposure is only marginal in three-month-old rats, it is more pronounced (significant) in 12-month-old rats. A similar decrease in enzyme activities of HK and PFK is also observe upon UVB exposure of the intact rat lens. The photoinduced changes in energy metabolism may in turn have a bearing on lens transparency, particularly at an older age.
Resumo:
This chapter will examine how transnational film making allows national and iconic stories to shift outside their imposed national boundaries, freeing them from “nation building” constraints and predetermined ideological motivations. Each interpretation creates one more dimension to the story’s complexity and hybridity assuring its continuance and relevance into the future. Each new film version, and in the case of iconic stories, each new transnational film version, breathes new energy and life into the stories and also stops monolithic ownership of them. What is also of interest in this chapter is the judgement cast upon each of the retelling and adaptations of these iconic stories. Every adaptation is weighed up and judged against a mythic ideal, and as such, each always falls short of imagined expectations. But in a paradoxical fashion, it is this failure to capture that provides the impetus for the story’s future retellings.
Resumo:
Maximum intensity contrast has been used as a measure of lens defocus. A photodiode array under the control of 8085 microprocessor is used to measure the maximum intensity contrast and to position the lens for best focus. The lens is moved by a stepper motor under processor control at a speed of 350 to 500 steps/s. At this speed, focusing time was found to be between 5 and 8 s. Under coherent illuminating conditions, an accuracy of ± 50 μm has been achieved.
Resumo:
Purpose Transient changes in corneal topography associated with soft and conventional or reverse geometry rigid contact lens wear have been well documented; however, only a few studies have examined the influence of scleral contact lens wear upon the cornea. Therefore, in this study, we examined the influence of modern miniscleral contact lenses, which land entirely on the sclera and overlying tissues, upon anterior corneal curvature and optics. Methods Anterior corneal topography and elevation data were acquired using Scheimpflug imaging (Pentacam HR, Oculus) immediately prior to and following 8 hours of miniscleral contact lens wear in 15 young healthy adults (mean age 22 ± 3 years, 8 East Asian, 7 Caucasian) with normal corneae. Corneal diurnal variations were accounted for using data collected on a dedicated measurement day without contact lens wear. Corneal clearance was quantified using an optical coherence tomographer (RS-3000, Nidek) following lens insertion and after 8 hours of lens wear. Results Although corneal clearance was maintained throughout the 8 hour lens wear period, significant corneal flattening (up to 0.08 ± 0.04 mm) was observed, primarily in the superior mid-peripheral cornea, which resulted in a slight increase in against-the-rule corneal astigmatism (mean +0.02/-0.15 x 94 for an 8 mm diameter). Higher order aberration terms of horizontal coma, vertical coma and spherical aberration all underwent significant changes for an 8 mm corneal diameter (p ≤ 0.01), which typically resulted in a decrease in RMS error values (mean change in total higher order RMS -0.035 ± 0.046 µm for an 8 mm diameter). There was no association between the magnitude of change in central or mid-peripheral corneal clearance during lens wear and the observed changes in corneal curvature (p > 0.05). However, Asian participants displayed a significantly greater reduction in corneal clearance (p = 0.04) and greater superior-nasal corneal flattening compared to Caucasians (p = 0.048). Conclusions Miniscleral contact lenses that vault the cornea induce significant changes in anterior corneal surface topography and higher order aberrations following 8 hours of lens wear. The region of greatest corneal flattening was observed in the superior-nasal mid-periphery, more so in Asian participants. Practitioners should be aware that corneal measurements obtained following miniscleral lens removal may mask underlying corneal steepening.
Resumo:
- Purpose To examine the change in corneal thickness and posterior curvature following 8 hours of miniscleral contact lens wear. - Methods Scheimpflug imaging (Pentacam HR, Oculus) was captured before, and immediately following, 8 hours of miniscleral contact lens wear for 15 young (mean age 22 ± 3 years), healthy participants with normal corneae. Natural diurnal variations were considered by measuring baseline corneal changes obtained on a separate control day without contact lens wear. - Results Over the central 6 mm of the cornea, a small, but highly statistically significant amount of edema was observed following 8 hours of miniscleral lens wear, after accounting for normal diurnal fluctuations (mean ± standard deviation percentage swelling 1.70 ± 0.98%, p < 0.0001). Posterior corneal topography remained stable following lens wear (-0.01 ± 0.07 mm steepening over the central 6 mm, p = 0.60). The magnitude of posterior corneal topographical changes following lens wear did not correlate with the extent of lens-related corneal edema (r = -0.16, p = 0.57). Similarly, the initial central corneal vault (maximum post-lens tear layer depth) was not associated with corneal swelling following lens removal (r = 0.27, p = 0.33). - Conclusions While a small amount of corneal swelling was induced following 8 hours of miniscleral lens wear (on average <2%), modern high Dk miniscleral contact lenses that vault the cornea do not induce clinically significant corneal edema or hypoxic related posterior corneal curvature changes during short-term wear. Longer-term studies of compromised eyes (e.g. corneal ectasia) are still required to inform the optimum lens and fitting characteristics for safe scleral lens wear to minimize corneal hypoxia.
Resumo:
Glaucoma is a multifactorial long-term ocular neuropathy associated with progressive loss of the visual field, retinal nerve fiber structural abnormalities and optic disc changes. Like arterial hypertension it is usually a symptomless disease, but if left untreated leads to visual disability and eventual blindness. All therapies currently used aim to lower intraocular pressure (IOP) in order to minimize cell death. Drugs with new mechanisms of action could protect glaucomatous eyes against blindness. Renin-angiotensin system (RAS) is known to regulate systemic blood pressure and compounds acting on it are in wide clinical use in the treatment of hypertension and heart failure but not yet in ophthalmological use. There are only few previous studies concerning intraocular RAS, though evidence is accumulating that drugs antagonizing RAS can also lower IOP, the only treatable risk factor in glaucoma. The main aim of this experimental study was to clarify the expression of the renin-angiotensin system in the eye tissues and to test its potential oculohypotensive effects and mechanisms. In addition, the possible relationship between the development of hypertension and IOP was evaluated in animal models. In conclusion, a novel angiotensin receptor type (Mas), as well as ACE2 enzyme- producing agonists for Mas, were described for the first time in the eye structures participating in the regulation of IOP. In addition, a Mas receptor agonist significantly reduced even normal IOP. The effect was abolished by a specific receptor antagonist. Intraocular, local RAS would thus to be involved in the regulation of IOP, probably even more in pathological conditions such as glaucoma though there was no unambiguous relationship between arterial and ocular hypertension. The findings suggest the potential as antiglaucomatous drugs of agents which increase ACE2 activity and the formation of angiotensin (1-7), or activate Mas receptors.
Resumo:
Since the late 1990s, the International Contact Lens Prescribing Survey Consortium has prospectively gathered information about 285,000 contact lens fits from more than 50 countries. This article presents our 14th annual summary of current trends published in Contact Lens Spectrum. With only minor differences in the distribution of our surveys among markets, we have continued to adopt the same approach throughout the past 18 years. Through national coordinators, we approach contact lens prescribers in each country and ask them to record information about the first 10 patients whom they fit with contact lenses after receipt of our survey form. The information collected is generic, and respondents are weighted to reflect the volume of contact lens fits undertaken by each. For this 2014 report, we present information about 25,179 contact lens fits from 32 countries...