991 resultados para hélicase E1
Resumo:
Invocatio: Q.B.V.
Resumo:
Invocatio: I.G.N.
Resumo:
Invocatio: D.D.
Resumo:
Invocatio: Auspice [et] Duce Deo.
Resumo:
Invocatio: M.D.H.B.
Resumo:
Painovuosi nimekkeestä.
Resumo:
Invocatio: D.D.
Resumo:
Arkit: 1 arkintunnukseton lehti, D4 E1.
Resumo:
Arkit: 1 arkintunnukseton lehti, A-D4 E1.
Resumo:
The present research aimed to study the parameters that affect the determination of estrogens in sewage upon the use of SPE and determination by using gas chromatography mass spectrometry (GC/MS). The study evaluated the stabilization pond technology with regard to estrogens removal. The results showed that the methodology was able to identify and quantify the estrogens E1, E2, E2-17A and EE2 in sewage. Moreover, the estrogens sometimes were not removed in the stabilization pond, showing that even the high hydraulic retention time (HRT) and high sunlight intensity were not enough to degrade these compounds completely during load peaks.
Resumo:
Lipid nanoemulsions have recently been proposed as parenteral delivery systems for poorly-soluble drugs. These systems consist of nanoscale oil/water dispersions stabilized by an appropriate surfactant system in which the drug is incorporated into the oil core and/or adsorbed at the interface. This article reviews technological aspects of such nanosystems, including their composition, preparation methods, and physicochemical properties. From this review, it was possible to identify five groups of nanoemulsions based on their composition. Biopharmaceutical aspects of formulations containing some commercially available drugs (diazepam, propofol, dexamethasone, etomidate, flurbiprofen and prostaglandin E1) were then discussed.
Resumo:
A simple and fast method for the determination of nimesulide (NI) using flow injection analysis with multiple-pulse amperometric (FIA-MPA) detection at a boron-doped diamond (BDD) electrode was developed. The method was based mainly on the application of a four-potential waveform, E1(det) = -0.8 V / 30 ms, E2(det) = 0.6 V / 30 ms, E3(det) = -0.4 V / 30 ms and E4(cleaning) = -0.45 V / 300 ms versus Ag/AgCl (3.0 mol L-1 KCl). NI was detected at three different electrode potentials, at which the nitro group undergoes different redox reactions. The proposed method was selective and sensitive (detection limit of 81.0 nmol L-1), and successfully applied for the determination of NI in pharmaceutical formulations, yielding similar results to those obtained by the reference method.
Resumo:
Density functional theory (DFT) calculations at the B3LYP/6-31G** theoretical level were performed for a series of guanidine-fused bicyclic skeleton derivatives C4N6H8-n(NO2)n (n = 1 - 6). The heats of formation (HOFs) were calculated by isodesmic reactions, and the detonation properties were evaluated using the Kamlet - Jacobs equations. The bond dissociation energies were also analyzed to investigate the thermal stability and sensitivity of the compounds. The results show that all of the derivatives have high positive HOFs, compound G has the highest theoretical density, and compound F1 has the highest detonation velocity and detonation pressure. Considering both the detonation properties and thermal stabilities, compounds D1 and D4 (3 nitro substituents), E1 - E6 (4 nitro substituents), and G (6 nitro substituents) can be regarded as potential candidates for high-energy density materials.
Resumo:
In this work, the efficiency of clarification treatment (coagulation, flocculation and sedimentation) with polyaluminum chloride (PAC) and aluminum sulfate (SA) as coagulants was evaluated in the removal of 7 microcontaminants (diclofenac - DCF, sulfamethoxazole - SMX, ethinylestradiol - EE2, bisphenol-A - BPA, estradiol - E2, estrone - E1 and estriol - E3) in water of low and high turbidity. The clarification treatment led to poor removal rates (40% at most) for all microcontaminants except SMX which exhibited intermediate removal efficiency (67 to 70%). Overall, PAC application yielded better performance compared to SA.
Resumo:
AbstractThe purpose of this study was to evaluate the best operating conditions of ICP OES for the determination of Na, Ca, Mg, Sr and Fe in aqueous extract of crude oil obtained after hot extraction with organic solvents (ASTM D 6470-99 modified). Thus, the full factorial design and central composite design were used to optimize the best conditions for the flow of nebulization gas, the flow of auxiliary gas, and radio frequency power. After optimization of variables, a study to obtain correct classification of the 18 samples of aqueous extract of crude oils (E1 to E18) from three production and refining fields was carried out. Exploratory analysis of these extracts was performed by principal component analysis (PCA), hierarchical cluster analysis (HCA) and linear discriminant analysis (LDA), using the original variables as the concentration of the metals Na, Ca, Mg, Sr and Fe determined by ICP OES.