991 resultados para Vogt, CarlVogt, CarlCarlVogt
Resumo:
Physical fitness can be evaluated in competitive and school sports with different field tests under different conditions and goals. To produce valid results, a field test must be practical and reach high standards of test criteria (objectivity, reliability, validity). The purpose of this study was to investigate the test criteria and the practicability of a group of field tests called «SUISSE Sport Test Konzept Basis Feldtestbatterie». For 20-m sprint, ventral trunk muscle test, standing long jump, 2-kg medicine ball shot, obstacle course and cooper-test, test quality and practicability were evaluated. 221 children and adolescents from competitive sports and different school levels took part in the study. According to school level, they were divided into 3 groups (P: 7–11.5 y, S1: 11.6–15.5 y, S2: 15.6–21.8 y). Objectivity was tested for time or distance measurement in all tests as well as for error rating in obstacle test. For reliability measurement, 162 subjects performed the field tests twice within a few weeks. For validity results of standing long jump were compared with counter movement jump performance on a force plate. Correlation analysis was performed and level of significance was set for p < 0.05. For accuracy standard error was calculated. All tests achieved sufficient to excellent objectiv - ity with correlation-coefficient (r) lying between 0.85 and 0.99. Reliability was very good (r = 0.84–0.97). In cooper- and trunk test, reliability was higher for athletes than for pupils (trunk test: r = 0.95 vs. r = 0.62, cooper-test: r = 0.90 vs. r = 0.78). In those tests the reliability decreases with increasing age (cooper-test: P: r = 0.84, S1: r = 0.69, S2: r = 0.52; trunk-test: P: r = 0.69, S1: r = 0.71; S2: r = 0.39). Validity for standing long jump was good (r = 0.75–0.86). The standard error of the mean was between 4–8%, with the exception for cooper-test (athletes: 6%, pupils: 11%) and trunk test (athletes: 14%, pupils: 46%). The results show that the evaluated group of field tests is a practicable, objective and reliable tool to determine physical skills in young athletes as well as in a scholar setting over a broad age range. Most of the tests achieved the test criteria with the grades good to excellent. The lower coefficient of reliability for cooper- and trunk test by the pupils could be explained by motivational problems in this setting. For up to 20 subjects, a tester can accomplish the tests within 3 h. Finally, age-dependent grades were elaborated
Resumo:
RNA helicases represent a large family of proteins implicated in many biological processes including ribosome biogenesis, splicing, translation and mRNA degradation. However, these proteins have little substrate specificity, making inhibition of selected helicases a challenging problem. The prototypical DEAD box RNA helicase, eIF4A, works in conjunction with other translation factors to prepare mRNA templates for ribosome recruitment during translation initiation. Herein, we provide insight into the selectivity of a small molecule inhibitor of eIF4A, hippuristanol. This coral-derived natural product binds to amino acids adjacent to, and overlapping with, two conserved motifs present in the carboxy-terminal domain of eIF4A. Mutagenesis of amino acids within this region allowed us to alter the hippuristanol-sensitivity of eIF4A and undertake structure/function studies. Our results provide an understanding into how selective targeting of RNA helicases for pharmacological intervention can be achieved.
Resumo:
Sarcopenia is the age-related loss of muscle mass and strength and has been associated with an increased risk of falling and the development of metabolic diseases. Various training protocols, nutritional and hormonal interventions have been proposed to prevent sarcopenia. This study explores the potential of continuous eccentric exercise to retard age-related loss of muscle mass and function. Elderly men and women (80.6 +/- 3.5 years) were randomized to one of three training interventions demanding a training effort of two sessions weekly for 12 weeks: cognitive training (CT; n = 16), conventional resistance training (RET; n = 23) and eccentric ergometer training (EET; n = 23). Subjects were tested for functional parameters and body composition. Biopsies were collected from M. vastus lateralis before and after the intervention for the assessment of fiber size and composition. Maximal isometric leg extension strength (MEL: +8.4 +/- 1.7%) and eccentric muscle coordination (COORD: -43 +/- 4%) were significantly improved with EET but not with RET (MEL: +2.3 +/- 2.0%; COORD: -13 +/- 3%) and CT (MEL: -2.3 +/- 2.5%; COORD: -12 +/- 5%), respectively. We observed a loss of body fat (-5.0 +/- 1.1%) and thigh fat (-6.9 +/- 1.5%) in EET subjects only. Relative thigh lean mass increased with EET (+2.5 +/- 0.6%) and RET (+2.0 +/- 0.3%) and correlated negatively with type IIX/type II muscle fiber ratios. It was concluded that both RET and EET are beneficial for the elderly with regard to muscle functional and structural improvements but differ in their spectrum of effects. A training frequency of only two sessions per week seems to be the lower limit for a training stimulus to reveal measurable benefits.
Resumo:
PURPOSE: Alpine ski performance relates closely to both anaerobic and aerobic capacities. During their competitive season, skiers greatly reduce endurance and weight training, and on-snow training becomes predominant. To typify this shift, we compared exhaustive ramp cycling and squat (SJ) and countermovement jumping (CMJ) performance in elite males before and after their competitive season. RESULTS: In postseason compared with preseason: 1) maximal oxygen uptake (VO 2 max) normalized to bodyweight was higher (55.2 +/- 5.2 vs 52.7 +/- 3.6 mL x kg(-1) x min(-1), P < 0.01), but corresponding work rate (W) was unchanged; 2) at ventilatory thresholds (VT), absolute and relative work rates were similar but heart rates were lower; 3) VO2/W slope was greater (9.59 +/- 0.6 vs 9.19 +/- 0.4 mL O2 x min(-1) x W(-1), P = 0.02), with similar flattening (P < 0.01) above V T1 at both time points; and 4) jump height was greater in SJ (47.4 +/- 4.4 vs 44.7 +/- 4.3 cm, P < 0.01) and CMJ (52.7 +/- 4.6 vs 50.4 +/- 5.0 cm, P < 0.01). DISCUSSION: We believe that aerobic capacity and leg power were constrained in preseason and that improvements primarily reflected an in-season recovery from a fatigued state, which was caused by incongruous preseason training. Residual adaptations to high-altitude exposure in preseason could have also affected the results. Nonetheless, modern alpine skiing seemingly provides an ample cardiovascular training stimulus for skiers to maintain their aerobic capacities during the racing season. CONCLUSIONS: We conclude that aerobic fitness and leg explosiveness can be maintained in-season but may be compromised by heavy or excessive preseason training. In addition, ramp test V O2/W slope analysis could be useful for monitoring both positive and negative responses to training.
Resumo:
BACKGROUND: Difference in pulse pressure (dPP) reliably predicts fluid responsiveness in patients. We have developed a respiratory variation (RV) monitoring device (RV monitor), which continuously records both airway pressure and arterial blood pressure (ABP). We compared the RV monitor measurements with manual dPP measurements. METHODS: ABP and airway pressure (PAW) from 24 patients were recorded. Data were fed to the RV monitor to calculate dPP and systolic pressure variation in two different ways: (a) considering both ABP and PAW (RV algorithm) and (b) ABP only (RV(slim) algorithm). Additionally, ABP and PAW were recorded intraoperatively in 10-min intervals for later calculation of dPP by manual assessment. Interobserver variability was determined. Manual dPP assessments were used for comparison with automated measurements. To estimate the importance of the PAW signal, RV(slim) measurements were compared with RV measurements. RESULTS: For the 24 patients, 174 measurements (6-10 per patient) were recorded. Six observers assessed dPP manually in the first 8 patients (10-min interval, 53 measurements); no interobserver variability occurred using a computer-assisted method. Bland-Altman analysis showed acceptable bias and limits of agreement of the 2 automated methods compared with the manual method (RV: -0.33% +/- 8.72% and RV(slim): -1.74% +/- 7.97%). The difference between RV measurements and RV(slim) measurements is small (bias -1.05%, limits of agreement 5.67%). CONCLUSIONS: Measurements of the automated device are comparable with measurements obtained by human observers, who use a computer-assisted method. The importance of the PAW signal is questionable.
Resumo:
BACKGROUND: The single-use supraglottic airway devices LMA-Supreme (LMA-S; Laryngeal Mask Company, Henley-on-Thames, United Kingdom) and i-gel (Intersurgical Ltd, Wokingham, Berkshire, United Kingdom) have a second tube for gastric tube insertion. Only the LMA-S has an inflatable cuff. They have the same clinical indications and might be useful for difficult airway management. This prospective, crossover, randomized controlled trial was performed in a simulated difficult airway scenario using an extrication collar limiting mouth opening and neck movement. METHODS: Sixty patients were included. Both devices were placed in random order in each patient. Primary outcome was overall success rate. Other measurements were time to successful ventilation, airway leak pressure, fiberoptic glottic view, and adverse events. RESULTS: Success rate for the LMA-S was 95% versus 93% for the i-gel (P = 1.000). LMA-S needed shorter insertion time (34 +/- 12 s vs. 42 +/- 23 s, P = 0.024). Tidal volumes and airway leak pressure were similar (LMA-S 26 +/- 8 cm H20; i-gel 27 +/- 9 cm H20; P = 0.441). Fiberoptic view through the i-gel showed less epiglottic downfolding. Overall agreement in insertion outcome was 54 (successes) and 1 (failure) or 55 (92%) of 60 patients. The difference in success rate was 1.7% (95% CI -11.3% to 7.6%). CONCLUSIONS: Both airway devices had similar insertion success and clinical performance in the simulated difficult airway situation. The authors found less epiglottic downfolding and better fiberoptic view but longer insertion time with the i-gel. Our study shows that both devices are feasible for emergency airway management in patients with reduced neck movement and limited mouth opening.
Resumo:
Laparoscopic surgery was introduced into clinical practice in the early 1950s by gynaecologists. Technical improvements allowed its use for more complex and longer lasting procedures. Reduction of postoperative pain, more favourable cosmetic results, quicker recovery and reduced length of hospital stay proved to be advantageous when compared to open surgery. As a result progressively older patients with corresponding pulmonary and cardiovascular comorbidities and morbidly obese patients are now undergoing advanced laparoscopic surgery. Detailed knowledge of the respiratory and hemodynamic pathophysiology induced by capnoperitoneum is necessary to administer safe anaesthesia to such patients. This review addresses the most important effects of capnoperitoneum and recent research as well as the possible implications for clinical practice.