911 resultados para Unsaturated polyester
Resumo:
In this study, the added value resultant from the incorporation of pultrusion production waste into polymer based concretes was assessed. For this purpose, different types of thermoset composite scrap material, proceeding from GFRP pultrusion manufacturing process, were mechanical shredded and milled into a fibrous-powdered material. Resultant GFRP recyclates, with two different size gradings, were added to polyester based mortars as fine aggregate and filler replacements, at various load contents between 4% up to 12% in weight of total mass. Flexural and compressive loading capacities were evaluated and found better than those of unmodified polymer mortars. Obtained results highlight the high potential of recycled GFRP pultrusion waste materials as efficient and sustainable admixtures for concrete and mortar-polymer composites, constituting an emergent waste management solution.
Resumo:
To date, glass fibre reinforced polymer (GFRP) waste recycling is very limited and restricted by thermoset nature of binder matrix and lack of economically viable enduse applications for the recyclates. In this study, efforts were made in order to recycle grinded GFRP waste proceeding from pultrusion production scrap, into new and sustainable composite materials. For this purpose, GFRP waste recyclates, a mix of powdered and fibrous materials, were incorporated into polyester based mortars as fine aggregate and filler replacements, at different load contents (between 4% up to 12% of total mass) and particle size distributions. Potential recycling solution was assessed by mechanical behaviour of resultant GFRP waste modified polymer mortars. Test results revealed that GFRP waste filled polymer mortars present improved flexural and compressive behaviour over unmodified polyester based mortars, thus indicating the feasibility of GFRP waste reuse in concrete-polymer composites.
Resumo:
In this paper, we present two Partial Least Squares Regression (PLSR) models for compressive and flexural strength responses of a concrete composite material reinforced with pultrusion wastes. The main objective is to characterize this cost-effective waste management solution for glass fiber reinforced polymer (GFRP) pultrusion wastes and end-of-life products that will lead, thereby, to a more sustainable composite materials industry. The experiments took into account formulations with the incorporation of three different weight contents of GFRP waste materials into polyester based mortars, as sand aggregate and filler replacements, two waste particle size grades and the incorporation of silane adhesion promoter into the polyester resin matrix in order to improve binder aggregates interfaces. The regression models were achieved for these data and two latent variables were identified as suitable, with a 95% confidence level. This technological option, for improving the quality of GFRP filled polymer mortars, is viable thus opening a door to selective recycling of GFRP waste and its use in the production of concrete-polymer based products. However, further and complementary studies will be necessary to confirm the technical and economic viability of the process.
Resumo:
Glass fibre-reinforced plastics (GFRP) have been considered inherently difficult to recycle due to both: cross-linked nature of thermoset resins, which cannot be remoulded, and complex composition of the composite itself. Presently, most of the GFRP waste is landfilled leading to negative environmental impacts and supplementary added costs. With an increasing awareness of environmental matters and the subsequent desire to save resources, recycling would convert an expensive waste disposal into a profitable reusable material. In this study, efforts were made in order to recycle grinded GFRP waste, proceeding from pultrusion production scrap, into new and sustainable composite materials. For this purpose, GFRP waste recyclates, were incorporated into polyester based mortars as fine aggregate and filler replacements at different load contents and particle size distributions. Potential recycling solution was assessed by mechanical behaviour of resultant GFRP waste modified polymer mortars. Results revealed that GFRP waste filled polymer mortars present improved flexural and compressive behavior over unmodified polyester based mortars, thus indicating the feasibility of the GFRP industrial waste reuse into concrete-polymer composite materials.
Resumo:
Octopus vulgaris, Octopus maya, and Eledone cirrhosa from distinct marine environments [Northeast Atlantic (NEA), Northwest Atlantic (NWA), Eastern Central Atlantic, Western Central Atlantic (WCA), Pacific Ocean, and Mediterranean Sea] were characterized regarding their lipid and vitamin E composition. These species are those commercially more relevant worldwide. Significant interspecies and interorigin differences were observed. Unsaturated fatty acids account for more than 65% of total fatty acids, mostly ω-3 PUFA due to docosahexaenoic (18.4−29.3%) and eicosapentanoic acid (11.4− 23.9%) contributions. The highest ω-3 PUFA amounts and ω-3/ω-6 ratios were quantified in the heaviest specimens, O. vulgaris from NWA, with high market price, and simultaneously in the lowest graded samples, E. cirrhosa from NEA, of reduced dimensions. Although having the highest cholesterol contents, E. cirrhosa from NEA and O. maya from WCA have also higher protective fatty acid indexes. Chemometric discrimination allowed clustering the selected species and several origins based on lipid and vitamin E profiles.
Resumo:
Glass fibre-reinforced plastics (GFRP) have been considered inherently difficult to recycle due to both: crosslinked nature of thermoset resins, which cannot be remoulded, and complex composition of the composite itself. Presently, most of the GFRP waste is landfilled leading to negative environmental impacts and supplementary added costs. With an increasing awareness of environmental matters and the subsequent desire to save resources, recycling would convert an expensive waste disposal into a profitable reusable material. In this study, efforts were made in order to recycle grinded GFRP waste, proceeding from pultrusion production scrap, into new and sustainable composite materials. For this purpose, GFRP waste recyclates, were incorporated into polyester based mortars as fine aggregate and filler replacements at different load contents and particle size distributions. Potential recycling solution was assessed by mechanical behaviour of resultant GFRP waste modified polymer mortars. Results revealed that GFRP waste filled polymer mortars present improved flexural and compressive behaviour over unmodified polyester based mortars, thus indicating the feasibility of the GFRP industrial waste reuse into concrete-polymer composite materials.
Resumo:
Esta dissertação teve como objetivo fundamental a otimização energética do sistema de refrigeração da máquina de impregnar tela ZELL e, como objetivo adicional, a avaliação da qualidade da água do circuito, justificada pela acentuada degradação dos rolos devido à corrosão provocada pela recirculação da água de arrefecimento. Inicialmente fez-se o levantamento de informações do processo produtivo para caracterizar o funcionamento do sistema de refrigeração, tendo-se selecionado duas telas de poliéster designadas neste estudo por P1 e P2 e, também, uma tela de nylon designada por N. Foram efetuados ensaios, um para cada tela, para a atual temperatura de setpoint da água à saída da torre de arrefecimento (30ºC). Realizou-se outro ensaio para a tela N mas com uma temperatura de setpoint de 37ºC, ao qual se chamou N37. Deste modo, determinou-se as potências térmicas removidas pela água de refrigeração e as potências térmicas perdidas por radiação e por convecção, tendo-se verificado que na generalidade dos rolos as referências P1 e P2 apresentam valores mais elevados. Em termos percentuais, a potência térmica removida pela água de refrigeração nos grupos tratores 1 e 3 e no conjunto de rolos de R1 a R29 corresponde a 48%, 10% e 70%, respetivamente. Com a avaliação às necessidades de arrefecimento da máquina ZELL, confirmou-se que os caudais atuais de refrigeração dos rolos garantem condições, mais que suficientes, de funcionamento dos rolamentos. Assim sendo, fez-se uma análise no sentido da diminuição do caudal total que passou de 10,25 L/s para 7,65 L/s. Considerando esta redução, determinou-se o caudal de ar húmido a ser introduzido na torre de arrefecimento. O valor determinado foi de 4,6 m3ar húmido/s, o que corresponde a uma redução de cerca de 32% em relação ao caudal atual que é de 6,8 m3ar húmido/s. Com os resultados das análises efetuadas à água do circuito de refrigeração, concluiu-se que a água de reposição e a água de recirculação possuem má qualidade para uso na generalidade dos sistemas de refrigeração, principalmente devido aos elevados valores de concentração de ferro e condutividade elétrica, responsáveis pela intensificação da corrosão no interior dos rolos.
Resumo:
O Biodiesel é uma fonte de energia renovável que actualmente se encontra em expansão. O Biodiesel é constituído por uma mistura de ésteres alquílicos de ácidos gordos. A existência de ácidos gordos insaturados torna o Biodiesel quimicamente menos estável, podendo ocorrer oxidação, degradação e polimerização do combustível, se este for inadequadamente armazenado ou transportado. O objectivo deste trabalho consistiu em avaliar a eficiência da utilização de antioxidantes fenólicos (ácido protocatecuico, ácido gálico, ácido 3,4 di-hidroxifenilacético, ácido cafeico, ácido hidrocafeico, ácido 3,4,5-tri-hidroxicinâmico, ácido m-coumárico e ácido p-coumárico), na estabilização do Biodiesel. O estudo envolveu a análise da influência do uso de cada um dos antioxidantes na inibição da peroxidação lipídica do ácido linoleico um dos principais ácidos gordos insaturados presentes na matéria-prima utilizada na produção de Biodiesel. A avaliação do efeito de inibição dos antioxidantes na peroxidação do ácido linoleico foi efetuada usando o método do tiocianato de ferro (III). Os resultados obtidos demonstraram, que todos os ácidos fenólicos estudados, apresentam uma elevada capacidade para inibir a peroxidação lipídica do ácido linoleico. As percentagens de inibição da peroxidação do ácido linoleico variaram entre os 72%, observada para o ácido p-coumárico, e os 82 %, verificada para o ácido protocatecuico. A eficiência de inibição da peroxidação por parte dos antioxidantes fenólicos em estudo foi comparada com a obtida utilizando um antioxidante de referência, o trolox. A eficiência de inibição obtida para todos os antioxidantes fenólicos estudados foi muito superior à observada para o trolox. Os resultados obtidos nesta dissertação permitem concluir que a utilização de ácidos fenólicos constitui uma boa alternativa para a estabilização de matrizes lipídicas, particularmente em combustíveis como o Biodiesel.
Resumo:
Glass fibre-reinforced plastics (GFRP), nowadays commonly used in the construction, transportation and automobile sectors, have been considered inherently difficult to recycle due to both the cross-linked nature of thermoset resins, which cannot be remoulded, and the complex composition of the composite itself, which includes glass fibres, polymer matrix and different types of inorganic fillers. Hence, to date, most of the thermoset based GFRP waste is being incinerated or landfilled leading to negative environmental impacts and additional costs to producers and suppliers. With an increasing awareness of environmental matters and the subsequent desire to save resources, recycling would convert an expensive waste disposal into a profitable reusable material. In this study, the effect of the incorporation of mechanically recycled GFRP pultrusion wastes on flexural and compressive behaviour of polyester polymer mortars (PM) was assessed. For this purpose, different contents of GFRP recyclates (0%, 4%, 8% and 12%, w/w), with distinct size grades (coarse fibrous mixture and fine powdered mixture), were incorporated into polyester PM as sand aggregates and filler replacements. The effect of the incorporation of a silane coupling agent was also assessed. Experimental results revealed that GFRP waste filled polymer mortars show improved mechanical behaviour over unmodified polyester based mortars, thus indicating the feasibility of GFRP waste reuse as raw material in concrete-polymer composites.
Resumo:
The aim of the present study was to verify the activity of the Tri-N-Butyl Tin maleate compound against Staphylococcus aureus and Aspergillus niger, after its industrial application in 40 samples of carpets of different materials (polypropylene, polyester, polyamide and wool). The qualitative assays were performed through two methodologies: Inhibition Halo (HZ) and Inhibition of Surface (Print). The carpet with the product inhibited 100% of bacterial (Staphylococcus aureus) and fungi (Aspergillus niger) growth, under the conditions of this study. The microbial inhibition was higher in upper portion of carpets. The methodologies employed appear to be adequate to test the bactericide and fungicide activities of the Tri-N-Butyl Tin maleate. The print methodology confirmed the results obtained by the inhibition zone assay. Further studies using the same methodologies are needed to confirm our results.
Resumo:
Este trabalho realizou-se na empresa Continental – Indústria Têxtil do Ave, S.A (CITA) em colaboração com a empresa Cofely GDF Suez – Energia e Serviços Portugal, S.A. O principal objetivo desta dissertação foi a otimização energética da máquina de impregnar telas para pneus – a máquina ZELL, tendo em conta as principais utilidades envolvidas: eletricidade e gás natural. Deste modo foi feito um levantamento prévio das condições de operação desta máquina relativamente às telas mais representativas da produção da empresa. Tendo-se verificado que as telas em poliéster representam 65% da produção total da máquina ZELL. Para este tipo de produto, foi feita uma análise dos consumos energéticos anuais para avaliar qual das utilidades referidas corresponde à maior parcela energética. Verificou-se que o consumo de gás natural representa a maior parcela da fatura energética anual da empresa correspondendo a 47%. Além disso, da energia total consumida anualmente pela ZELL, que corresponde a 1360 tep, 32% é relativo à energia elétrica e os restantes 68% ao consumo de gás natural. Por fim, procedeu-se à otimização energética estudando as alterações possíveis no sentido de reduzir os consumos energéticos da máquina, sem prejuízo da qualidade do produto final. Para isso propôs-se a instalação de permutadores de fluxo cruzado para pré-aquecer quer o ar fresco quer o ar de combustão. A implementação desta medida tem um período de retorno à volta de três anos e pode levar a uma poupança anual entre 1.359.639 kWh e 2.370.114 kWh para o ar fresco e 393.523 kWh e 639.475 kWh para o ar de combustão.
Resumo:
A presente dissertação realizada na empresa Continental-Indústria Têxtil do Ave, S.A., teve como objetivo a otimização energética da secção das malhas. Esta secção divide-se em duas áreas, a tricotagem e a ramulagem. Os artigos produzidos diferem no seu peso específico, composição e condições de operação, sendo os artigos A, B e C compostos por poliéster e termofixados a 190ºC e os artigos D e E compostos por poliéster e algodão, com uma temperatura de operação de 205ºC. Numa primeira etapa estudou-se o funcionamento da máquina de termofixação – a râmula – que opera em trabalho contínuo a 40 m/min. Esta máquina tem incorporado um permutador de calor, que aquece o ar fresco de entrada com os gases de exaustão das estufas. Posteriormente efetuou-se o levantamento energético de cada artigo, para as áreas de tricotagem e ramulagem. Verificou-se que os artigos D e E, pela sua constituição, são os que apresentam um consumo específico superior, em tep/ton. Entre as várias utilidades consumidas (gás natural, eletricidade e ar comprimido) o gás natural representa mais de 50% do consumo de energia total necessário para a produção de cada artigo. Após a completa análise aos consumos energéticos da râmula, foram realizados ensaios de otimização, tendo-se concluído que a diminuição do caudal de exaustão pode atingir valores de poupança anual de gás natural na ordem dos 3.000 €. Com o objetivo de avaliar o consumo de gás natural, não sendo possível a realização experimental, foram feitas simulações com base em alterações na corrente de entrada de ar fresco no permutador. Foi também estudada a possibilidade de isolamento e revestimento térmico da conduta exterior, projetada para o reaproveitamento do ar dos compressores, tendo-se obtido um orçamento de 2.500 €. Admitindo-se uma gama de temperaturas entre os 40ºC e os 60ºC, com um caudal de insuflação de 30%, obteve-se um payback entre os 0,97 e os 3,28 anos. Numa segunda fase admitiu-se uma temperatura média de 50ºC, aumentando o caudal de insuflação até 100%. O período de retorno obtido variou entre os 0,33 e os 1,38 anos, podendo as poupanças anuais atingirem os 7.600 €.
Resumo:
Os ácidos gordos desempenham um papel fisiológico importante como componentes indispensáveis na estrutura celular, bem como fontes de energia. Nas últimas décadas, tem havido um aumento notável do interesse público nos ácidos gordos polinsaturados ómegas 3 e 6 e no seu impacto sobre a saúde humana, especialmente em doenças metabólicas e cardiovasculares. Estes ácidos gordos específicos podem prevenir e/ou tratar várias patologias metabólicas, atuando nomeadamente como compostos anti-inflamatórios. A menopausa é um fator de risco para doença cardiovascular, a diminuição de estrogénio, que ocorre neste estado fisiológico, provoca disfunção endotelial e stresse oxidativo. Consequentemente há uma redução dos níveis de ácidos gordos polinsaturados ómegas 3, o que contribui para o aparecimento de aterosclerose e doença cardiovascular. Neste contexto, o objetivo deste estudo foi avaliar e caracterizar o perfil lipídico de ácidos gordos de uma amostra de mulheres pós-menopausa e com este, estudar as associações entre o perfil lipídico determinado e parâmetros metabólicos de risco (parâmetros clínicos e bioquímicos). Inicialmente, os ácidos gordos foram extraídos da matriz plasmática através da derivatização destes e a sua composição percentual no plasma foi determinada com recurso a cromatografia gasosa com deteção de ionização de chama. De seguida, através do software IBM SPSS Statistics 21, foram estabelecidas associações entre os parâmetros clínicos e bioquímicos e o perfil lipídico determinado. A população em estudo foi divida em dois grupos consoante o período de entrada na menopausa (há menos de 7 anos e há 7 anos ou mais). Não há conhecimento de estudos semelhantes ao apresentado, que relacionem todo o perfil de ácidos gordos com parâmetros metabólicos de risco considerando o estado menopausal. Os resultados obtidos mostram que o perfil lipídico influencia vários marcadores metabólicos / endócrinos com relevância clínica que devem ser explorados em futuros ensaios clínicos. Para as mulheres na menopausa há menos de 7 anos foram estabelecidas as seguintes relações: i) entre os ácidos gordos saturados e insaturados cis e os níveis de ALP; ii) entre os ácidos gordos mono e polinsaturados cis e os níveis de GGT, IL10 e estradiol; iii) entre os ácidos gordos polinsaturados trans e o IMC e os níveis de IL6; iv) entre os ómegas 3 e os níveis de IL10 e ácido úrico; v) entre os ómegas 6 e os níveis de estradiol, ALP e GGT; vi) entre os ómegas 9 e os níveis de estradiol e GGT; vi) entre os ácidos gordos de curta cadeia e os níveis de colesterol total, LDL, triglicerídeos e IL10; vii) entre os ácidos gordos saturados de cadeia longa e o ΣÁcido láurico, mirístico, palmítico e esteárico e os níveis de triglicerídeos, ALP e GGT; viii) os níveis de IL10 podem ser simultaneamente associados com os ácidos gordos de curta cadeia e os ómegas 3. Para as mulheres na menopausa há 7 anos ou mais foram estabelecidas relações: i) entre os ómegas 3 e o IMC e os níveis de triglicerídeos; ii) entre os ácidos gordos monoinsaturados cis e os ómegas 9 com os níveis de ALT. Relações independentes do estado menopausal também foram estabelecidas, nomeadamente: i) entre os ácidos gordos polinsaturados cis e ómegas 6 e os níveis de ALT, triglicerídeos e AST; ii) entre os níveis de ácidos gordos monoinsaturados cis e ómegas 9 e os níveis de AST e triglicerídeos. O perfil lipídico de ácidos gordos pode ser considerado um biomarcador para a condição de saúde da mulher na menopausa.
Resumo:
OBJECTIVE:Endograft mural thrombus has been associated with stent graft or limb thrombosis after endovascular aneurysm repair (EVAR). This study aimed to identify clinical and morphologic determinants of endograft mural thrombus accumulation and its influence on thromboembolic events after EVAR. METHODS: A prospectively maintained database of patients treated by EVAR at a tertiary institution from 2000 to 2012 was analyzed. Patients treated for degenerative infrarenal abdominal aortic aneurysms and with available imaging for thrombus analysis were considered. All measurements were performed on three-dimensional center-lumen line computed tomography angiography (CTA) reconstructions. Patients with thrombus accumulation within the endograft's main body with a thickness >2 mm and an extension >25% of the main body's circumference were included in the study group and compared with a control group that included all remaining patients. Clinical and morphologic variables were assessed for association with significant thrombus accumulation within the endograft's main body by multivariate regression analysis. Estimates for freedom from thromboembolic events were obtained by Kaplan-Meier plots. RESULTS: Sixty-eight patients (16.4%) presented with endograft mural thrombus. Median follow-up time was 3.54 years (interquartile range, 1.99-5.47 years). In-graft mural thrombus was identified on 30-day CTA in 22 patients (32.4% of the study group), on 6-month CTA in 8 patients (11.8%), and on 1-year CTA in 17 patients (25%). Intraprosthetic thrombus progressively accumulated during the study period in 40 patients of the study group (55.8%). Overall, 17 patients (4.1%) presented with endograft or limb occlusions, 3 (4.4%) in the thrombus group and 14 (4.1%) in the control group (P = .89). Thirty-one patients (7.5%) received an aortouni-iliac (AUI) endograft. Two endograft occlusions were identified among AUI devices (6.5%; overall, 0.5%). None of these patients showed thrombotic deposits in the main body, nor were any outflow abnormalities identified on the immediately preceding CTA. Estimated freedom from thromboembolic events at 5 years was 95% in both groups (P = .97). Endograft thrombus accumulation was associated with >25% proximal aneurysm neck thrombus coverage at baseline (odds ratio [OR], 1.9; 95% confidence interval [CI], 1.1-3.3), neck length ≤ 15 mm (OR, 2.4; 95% CI, 1.3-4.2), proximal neck diameter ≥ 30 mm (OR, 2.4; 95% CI, 1.3-4.6), AUI (OR, 2.2; 95% CI, 1.8-5.5), or polyester-covered stent grafts (OR, 4.0; 95% CI, 2.2-7.3) and with main component "barrel-like" configuration (OR, 6.9; 95% CI, 1.7-28.3). CONCLUSIONS: Mural thrombus formation within the main body of the endograft is related to different endograft configurations, main body geometry, and device fabric but appears to have no association with the occurrence of thromboembolic events over time.
Resumo:
Dissertação apresentada para a obtenção do Grau de Mestre em Genética Molecular e Biomedicina, pela Universidade N ova de Lisboa, Faculdade de Ciências e Tecnologia