991 resultados para Sta Analyser
Water vapour isotopes analyser raw data from POLARSTERN cruise PS93.2 (ARK-XXIX/2.2), links to files
Resumo:
Gelatinisation and retrogradation of starch-whey mixtures were studied in water (pH 7) using the Rapid Visco-Analyser (RVA). The starch:whey ratios ranged from 0:100 - 100:0. Wheat starch, and whey protein concentrate (about 80% solids basis) and isolate (about 96% solids basis) were used. Mixtures with whey isolates were generally more viscous than those with whey concentrates, and this was attributed to fewer non-protein milk components in the former. Whey protein concentrates and isolates reduced the peak, trough and final viscosities of the mixtures, but the breakdown and setback ratios of the mixtures were increased. The gelatinisation temperature increased with whey substitutions indicating that whey protein delayed starch gelatinisation. The temperature of fastest viscosity development decreased as the amount of whey was increased. Whey protein isolate generally exercised a lesser effect than the concentrate. At between 40 - 50% whey substitutions, the dominant phase changed from starch to protein irrespective of the source of the whey protein. An additive law poorly defined selected RVA parameters. Both macromolecules interacted to define the viscosity of the mixture, and an exponential model predicted the viscosity better than the additive law. The results obtained in this study are discussed to assist the understanding of extrusion processing of starch-whey systems as models for whey-fortified snack and ready-to-eat foods. Copyright ©2006 The Berkeley Electronic Press. All rights reserved.
Resumo:
Following a scene-setting introduction are detailed reviews of the relevant scientific principles, thermal analysis as a research tool and the development of the zinc-aluminium family of alloys. A recently introduced simultaneous thermal analyser, the STA 1500, its use for differential thermal analysis (DTA) being central to the investigation, is described, together with the sources of support information, chemical analysis, scanning electron microscopy, ingot cooling curves and fluidity spiral castings. The compositions of alloys tested were from the binary zinc-aluminium system, the ternary zinc-aluminium-silicon system at 30%, 50% and 70% aluminium levels, binary and ternary alloys with additions of copper and magnesium to simulate commercial alloys and five widely used commercial alloys. Each alloy was shotted to provide the smaller, 100mg, representative sample required for DTA. The STA 1500 was characterised and calibrated with commercially pure zinc, and an experimental procedure established for the determination of DTA heating curves at 10°C per minute and cooling curves at 2°C per minute. Phase change temperatures were taken from DTA traces, most importantly, liquidus from a cooling curve and solidus from both heating and cooling curves. The accepted zinc-aluminium binary phase diagram was endorsed with the added detail that the eutectic is at 5.2% aluminium rather than 5.0%. The ternary eutectic trough was found to run through the points, 70% Al, 7.1% Si, 545°C; 50% Al, 3.9% Si, 520°C; 30% Al, 1.4% Si, 482°C. The dendrite arm spacing in samples after DTA increased with increasing aluminium content from 130m at 30% to 220m at 70%. The smallest dendrite arm spacing of 60m was in the 30% aluminium 2% silicon alloy. A 1kg ingot of the 10% aluminium binary alloy, insulated with Kaowool, solidified at the same 2°C per minute rate as the DTA samples. A similar sized sand casting was solidified at 3°C per minute and a chill casting at 27°C per minute. During metallographic examination the following features were observed: heavily cored phase which decomposed into ' and '' on cooling; needles of the intermetallic phase FeAl4; copper containing ternary eutectic and copper rich T phase.
Resumo:
Aim: The aim of this study was to evaluate the practicality and accuracy of tonometers used in routine clinical practice for established keratoconus (KC). Methods: This was a prospective study of 118 normal and 76 keratoconic eyes where intraocular pressure (IOP) was measured in random order using the Goldman applanation tonometer (GAT), Pascal dynamic contour tonometer (DCT), Reichert ocular response analyser (ORA) and TonoPen XL tonometer. Corneal hysteresis (CH) and corneal resistance factor (CRF), as calculated by the ORA, were recorded. Central corneal thickness (CCT) was measured using an ultrasound pachymeter. Results: The difference in IOP values between instruments was highly significant in both study groups (p<0.001). All other IOP measures were significantly higher than those for GAT, except for the Goldmann-correlated IOP (average of the two applanation pressure points) (IOPg) as measured by ORA in the control group and the CH-corrected IOP (corneal-compensated IOP value) (IOPcc) measures in the KC group. CCT, CH and CRF were significantly less in the KC group (p<0.001). Apart from the DCT, all techniques tended to measure IOP higher in eyes with thicker corneas. Conclusion: The DCT and the ORA are currently the most appropriate tonometers to use in KC for the measurement of IOPcc. Corneal factors such as CH and CRT may be of more importance than CCT in causing inaccuracies in applanation tonometry techniques.
Resumo:
DUE TO COPYRIGHT RESTRICTIONS ONLY AVAILABLE FOR CONSULTATION AT ASTON UNIVERSITY LIBRARY AND INFORMATION SERVICES WITH PRIOR ARRANGEMENT
Water vapour isotopes analyser raw data from POLARSTERN cruise PS95.2 (ANT-XXXI/1.2), links to files