961 resultados para Radiometric correction
Resumo:
OBJECTIVE: To compare the classical neurosurgical technique with a new simplified technique for prenatal repair of a myelomeningocelelike defect in sheep. METHODS: A myelomeningocele-like defect (laminectomy and dural excision) was created in the lumbar region on day 90 of gestation in 9 pregnant sheep. Correction technique was randomized. In Group 1 the defect was corrected using the classic neurosurgical technique of three-layer suture (dura mater, muscle and skin closure) performed by a neurosurgeon. In Group 2, a fetal medicine specialist used a biosynthetic cellulose patch to protect the spinal cord and only the skin was sutured above it. Near term (day 132 of gestation) fetuses were sacrificed for pathological analysis. RESULTS: There were two miscarriages and one maternal death. In total, six cases were available for pathological analysis, three in each group. In Group 1, there were adherence of the spinal cord to the scar (meningo-neural adhesion) and spinal cord architecture loss with posterior funiculus destruction and no visualization of grey matter. In Group 2, we observed in all cases formation of a neo-dura mater, separating the nervous tissue from adjacent muscles, and preserving the posterior funiculus and grey matter. CONCLUSION: The new simplified technique was better than the classic neurosurgical technique. It preserved the nervous tissue and prevented the adherence of the spinal cord to the scar. This suggests the current technique used for the correction of spina bifida in humans may need to be reassessed.
Resumo:
Il presente studio si concentra sulle diverse applicazioni del telerilevamento termico in ambito urbano. Vengono inizialmente descritti la radiazione infrarossa e le sue interazioni con l’atmosfera terrestre, le leggi principali che regolano lo scambio di calore per irraggiamento, le caratteristiche dei sensori e le diverse applicazioni di termografia. Successivamente sono trattati nel dettaglio gli aspetti caratteristici della termografia da piattaforma satellitare, finalizzata principalmente alla valutazione del fenomeno dell'Urban Heat Island; vengono descritti i sensori disponibili, le metodologie di correzione per gli effetti atmosferici, per la stima dell'emissività delle superfici e per il calcolo della temperatura superficiale dei pixels. Viene quindi illustrata la sperimentazione effettuata sull'area di Bologna mediante immagini multispettrali ASTER: i risultati mostrano come sull'area urbana sia riscontrabile la presenza dell'Isola di Calore Urbano, anche se la sua quantificazione risulta complessa. Si procede quindi alla descrizione di potenzialità e limiti della termografia aerea, dei suoi diversi utilizzi, delle modalità operative di rilievo e degli algoritmi utilizzati per il calcolo della temperatura superficiale delle coperture edilizie. Tramite l’analisi di alcune esperienze precedenti vengono trattati l’influenza dell’atmosfera, la modellazione dei suoi effetti sulla radianza rilevata, i diversi metodi per la stima dell’emissività. Viene quindi introdotto il progetto europeo Energycity, finalizzato alla creazione di un sistema GeoWeb di supporto spaziale alle decisioni per la riduzione di consumi energetici e produzione di gas serra su sette città dell'Europa Centrale. Vengono illustrate le modalità di rilievo e le attività di processing dei datasets digitali per la creazione di mappe di temperatura superficiale da implementare nel sistema SDSS. Viene infine descritta la sperimentazione effettuata sulle immagini termiche acquisite nel febbraio 2010 sulla città di Treviso, trasformate in un mosaico georiferito di temperatura radiometrica tramite correzioni geometriche e radiometriche; a seguito della correzione per l’emissività quest’ultimo verrà trasformato in un mosaico di temperatura superficiale.
Resumo:
Nell'era genomica moderna, la mole di dati generata dal sequenziamento genetico è diventata estremamente elevata. L’analisi di dati genomici richiede l’utilizzo di metodi di significatività statistica per quantificare la robustezza delle correlazioni individuate nei dati. La significatività statistica ci permette di capire se le relazioni nei dati che stiamo analizzando abbiano effettivamente un peso statistico, cioè se l’evento che stiamo analizzando è successo “per caso” o è effettivamente corretto pensare che avvenga con una probabilità utile. Indipendentemente dal test statistico utilizzato, in presenza di test multipli di verifica (“Multiple Testing Hypothesis”) è necessario utilizzare metodi per la correzione della significatività statistica (“Multiple Testing Correction”). Lo scopo di questa tesi è quello di rendere disponibili le implementazioni dei più noti metodi di correzione della significatività statistica. È stata creata una raccolta di questi metodi, sottoforma di libreria, proprio perché nel panorama bioinformatico moderno non è stato trovato nulla del genere.
Resumo:
I Polar Codes sono la prima classe di codici a correzione d’errore di cui è stato dimostrato il raggiungimento della capacità per ogni canale simmetrico, discreto e senza memoria, grazie ad un nuovo metodo introdotto recentemente, chiamato ”Channel Polarization”. In questa tesi verranno descritti in dettaglio i principali algoritmi di codifica e decodifica. In particolare verranno confrontate le prestazioni dei simulatori sviluppati per il ”Successive Cancellation Decoder” e per il ”Successive Cancellation List Decoder” rispetto ai risultati riportati in letteratura. Al fine di migliorare la distanza minima e di conseguenza le prestazioni, utilizzeremo uno schema concatenato con il polar code come codice interno ed un CRC come codice esterno. Proporremo inoltre una nuova tecnica per analizzare la channel polarization nel caso di trasmissione su canale AWGN che risulta il modello statistico più appropriato per le comunicazioni satellitari e nelle applicazioni deep space. In aggiunta, investigheremo l’importanza di una accurata approssimazione delle funzioni di polarizzazione.
Resumo:
We report a new technique for vertical enlargement of the inferior border of the mandible.
Resumo:
The authors conducted a retrospective study on 24 consecutive adolescent scoliosis patients, 11 of whom were instrumented with hooks and 13 with hooks and screws (hybrid technique). The mean preoperative Cobb angle was 62.2 degrees (range: 48 degrees-96 degrees). The mean correction of the primary curve was 56.6% at followup after +/- 1.18 years ; there was no statistically significant difference between groups. Special attention was given to the postoperative quality of life (QOL) by means of the following scores: COMI patient self-assessment, SF-36, ODI, and VAS. Again, there was no statistical difference between groups but, interestingly, there was no correlation between QOL and degree of correction, after a follow-up period of +/- 2.1 years. Nevertheless, on the COMI patient self-assessment, there was a high level of satisfaction with treatment. Further studies should concentrate on how to achieve a high QOL, and abandon the best possible correction as a primary endpoint of success.
Resumo:
PET/CT guidance for percutaneous interventions allows biopsy of suspicious metabolically active bone lesions even when no morphological correlation is delineable in the CT images. Clinical use of PET/CT guidance with conventional step-by-step technique is time consuming and complicated especially in cases in which the target lesion is not shown in the CT image. Our recently developed multimodal instrument guidance system (IGS) for PET/CT improved this situation. Nevertheless, bone biopsies even with IGS have a trade-off between precision and intervention duration which is proportional to patient and personnel exposure to radiation. As image acquisition and reconstruction of PET may take up to 10 minutes, preferably only one time consuming combined PET/CT acquisition should be needed during an intervention. In case of required additional control images in order to check for possible patient movements/deformations, or to verify the final needle position in the target, only fast CT acquisitions should be performed. However, for precise instrument guidance accounting for patient movement and/or deformation without having a control PET image, it is essential to be able to transfer the position of the target as identified in the original PET/CT to a changed situation as shown in the control CT.
Resumo:
Background Leg edema is a common manifestation of various underlying pathologies. Reliable measurement tools are required to quantify edema and monitor therapeutic interventions. Aim of the present work was to investigate the reproducibility of optoelectronic leg volumetry over 3 weeks' time period and to eliminate daytime related within-individual variability. Methods Optoelectronic leg volumetry was performed in 63 hairdressers (mean age 45 ± 16 years, 85.7% female) in standing position twice within a minute for each leg and repeated after 3 weeks. Both lower leg (legBD) and whole limb (limbBF) volumetry were analysed. Reproducibility was expressed as analytical and within-individual coefficients of variance (CVA, CVW), and as intra-class correlation coefficients (ICC). Results A total of 492 leg volume measurements were analysed. Both legBD and limbBF volumetry were highly reproducible with CVA of 0.5% and 0.7%, respectively. Within-individual reproducibility of legBD and limbBF volumetry over a three weeks' period was high (CVW 1.3% for both; ICC 0.99 for both). At both visits, the second measurement revealed a significantly higher volume compared to the first measurement with a mean increase of 7.3 ml ± 14.1 (0.33% ± 0.58%) for legBD and 30.1 ml ± 48.5 ml (0.52% ± 0.79%) for limbBF volume. A significant linear correlation between absolute and relative leg volume differences and the difference of exact day time of measurement between the two study visits was found (P < .001). A therefore determined time-correction formula permitted further improvement of CVW. Conclusions Leg volume changes can be reliably assessed by optoelectronic leg volumetry at a single time point and over a 3 weeks' time period. However, volumetry results are biased by orthostatic and daytime-related volume changes. The bias for day-time related volume changes can be minimized by a time-correction formula.
Resumo:
To analyze the mechanism of overjet correction and space closure when treating Class II Division 1 patients by extracting the maxillary first molars.
Resumo:
For the examination of psychological stress effects on coagulation, the Dill and Costill correction (DCC) for hemoconcentration effects has been used to adjust for stress-induced plasma volume changes. Although the correction is appropriate for adjusting concentrations of various large blood constituents, it may be inappropriate for time-dependent or functional coagulation assays. Two new plasma reconstitution techniques for correcting hemoconcentration effects on stress-induced changes in coagulation were compared with the DCC.