278 resultados para Ppv


Relevância:

10.00% 10.00%

Publicador:

Resumo:

In the present study, the effects of Polybia paulista venom (PPV) on renal and vascular tissues were investigated. Isolated kidneys perfused with PPV (1 and 3 mu g/mL) had increased perfusion pressure, renal vascular resistance, urinary flow, and glomerular filtration rate; and reduced sodium tubular transport. Histological evaluation demonstrated deposits of proteins in Bowman's space and tubular lumen, and focal areas of necrosis. The venom promoted a cytotoxic effect on Madin-Darby canine kidney (MDCK) cells. A significant increase in lactic dehydrogenase levels was observed in response to venom exposure. In isolated mesenteric vascular beds, pressure and vascular resistance augmented in a dose-dependent manner. PPV increased the contractility of aortic rings maintained under basal tension. This contractile response was inhibited when preparations were maintained in Ca2+-free medium. Likewise, verapamil, a voltage-gated calcium channel blocker, also inhibited the contractile response. In this study, phentolamine, a blocker of a-adrenergic receptor blocker, significantly reduced the contractile effect of PPV in the aortic ring. In conclusion, PPV produced nephrotoxicity, which suggests a direct effect on necrotic cellular death in renal tubule cells. The vascular contractile effect of PPV appears to involve calcium influx through voltage-gated calcium channels via adrenergic regulation.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Conjugated organic semiconductors have been submitted to various electrical measurement techniques in order to reveal information about shallow levels and deep traps in the forbidden gap. The materials consisted of poly[2-methoxy, 5 ethyl (2' hexyloxy) paraphenylenevinylene] (MEH-PPV), poly(3-methylthiophene) (PMeT), and alpha-sexithienyl (alpha T6) and the employed techniques were IV, CV, admittance spectroscopy, TSC, capacitance and current transients. (C) 1999 Elsevier Science B.V. All rights reserved.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Transient capacitance methods were applied to the depletion region of an abrupt asymmetric n(+) -p junction of silicon and unintentionally doped poly[2-methoxy, 5 ethyl (2' hexyloxy) paraphenylenevinylene] (MEH-PPV). Studies in the temperature range 100-300 K show the presence of a majority-carrier trap at 1.0 eV and two minority traps at 0.7 and 1.3 eV, respectively. There is an indication for more levels for which the activation energy could not be determined. Furthermore, admittance data reveal a bulk activation energy for conduction of 0.12 eV, suggesting the presence of an additional shallow acceptor state. (C) 1999 American Institute of Physics. [S0003-6951(99)02308-6].

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Tese de Doutoramento em Ciências Veterinárias, Especialidade de Ciências Biológicas e Biomédicas

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Background: Incidence of jaundice is high in newborn infants. Since well appearing newborns are rapidly and routinely discharged from hospital, performing an inexpensive noninvasive pre-discharge screening test for evaluation of jaundice seems to be necessary. Objectives: This study was conducted to compare the accuracy of cutaneous v/s serum bilirubin measurements in this regard. Patients and Methods: This was a prospective cross sectional study conducted in Mahdieh hospital, Tehran. 613 neonates weighing ≥ 1,800 g with gestational age of ≥ 35 weeks were enrolled. A pre discharge transcutaneous bilirubin test (TcB) was performed in all. Serum samples were taken from neonates with TcB ≥ 5 mg/dL in first and > 8 mg/dL in second 24 hours. Decision for treatment or recheck of bilirubin level after discharge was made based on serum bilirubin results. Results: Based on the study protocol, among 613 studied neonates, 491 (80%) revealed high TcB, of them 240 (49%) cases showed TBC ≥ 5 mg/dL in first and 251 (51 %) in second pre-discharge 24 hours. TcB ranged 3.3 - 17.1, mean TcB in first 24 hours was 6.9 ± 1 .7 (mode 6) and in second 24 hours 9.1 ± 2.1 (mode 10). Of 491 neonates with high TcB, capillary serum sample was taken as the second step and 398 neonates revealed high total serum bilirubin (TsB) with the same protocol for TcB. 108 (27.1%) neonates showed TsB ≥ 5 mg/dL in first and 290 (72.9%) in second 24 hours. According to the study results TcB has a 81% positive predictive value (PPV) in diagnosis of hyperbilirubinemia. Correlation coefficient of TcB and TsB in highest rate is equal to 72% (P value < 0.001). Conclusions: TcB is an inexpensive, noninvasive and precise pre-discharge screening test for evaluation of hyperbilirubinemia, with a high PPV. It is highly recommended to be performed routinely due to high incidence of hyperbilirubinemia in neonates.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Conjugated organic semiconductors have been submitted to various electrical measurement techniques in order to reveal information about shallow levels and deep traps in the forbidden gap. The materials consisted of poly[2-methoxy, 5 ethyl (2' hexyloxy) paraphenylenevinylene] (MEH-PPV), poly(3-methylthiophene) (PMeT), and alpha-sexithienyl (alpha T6) and the employed techniques were IV, CV, admittance spectroscopy, TSC, capacitance and current transients. (C) 1999 Elsevier Science B.V. All rights reserved.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Transient capacitance methods were applied to the depletion region of an abrupt asymmetric n(+) -p junction of silicon and unintentionally doped poly[2-methoxy, 5 ethyl (2' hexyloxy) paraphenylenevinylene] (MEH-PPV). Studies in the temperature range 100-300 K show the presence of a majority-carrier trap at 1.0 eV and two minority traps at 0.7 and 1.3 eV, respectively. There is an indication for more levels for which the activation energy could not be determined. Furthermore, admittance data reveal a bulk activation energy for conduction of 0.12 eV, suggesting the presence of an additional shallow acceptor state. (C) 1999 American Institute of Physics. [S0003-6951(99)02308-6].

Relevância:

10.00% 10.00%

Publicador:

Resumo:

La tuberculosis TB es una de las principales causas de muerte en el mundo en individuos con infección por VIH. En Colombia esta coinfección soporta una carga importante en la población general convirtiéndose en un problema de salud pública. En estos pacientes las pruebas diagnósticas tienen sensibilidad inferior y la enfermedad evoluciona con mayor frecuencia hacia formas diseminadas y rápidamente progresivas y su diagnóstico oportuno representa un reto en Salud. El objetivo de este proyecto es evaluar el desempeño de las pruebas diagnósticas convencionales y moleculares, para la detección de TB latente y activa pacientes con VIH, en dos hospitales públicos de Bogotá. Para TB latente se evaluó la concordancia entre las pruebas QuantiFERON-TB (QTF) y Tuberculina (PPD), sugiriendo superioridad del QTF sobre la PPD. Se evaluaron tres pruebas diagnósticas por su sensibilidad y especificidad, baciloscopia (BK), GenoType®MTBDR plus (Genotype) y PCR IS6110 teniendo como estándar de oro el cultivo. Los resultados de sensibilidad (S) y especificidad (E) de cada prueba con una prevalencia del 19,4 % de TB pulmonar y extrapulmonar en los pacientes que participaron del estudio fue: BK S: 64% E: 99,1%; Genotype S: 77,8% E: 94,5%; PCRIS6110 S: 73% E: 95,5%, de la misma forma se determinaron los valores predictivos positivos y negativos (VPP y VPN) BK: 88,9% y 94,8%, Genotype S: 77,8% E: 94,5%; PCRIS6110 S: 90% y 95,7%. Se concluyó bajo análisis de curva ROC que las pruebas muestran un rendimiento diagnóstico similar por separado en el diagnóstico de TB en pacientes con VIH, aumentando su rendimiento diagnostico cuando se combinan