931 resultados para PERINATAL TRANSMISSION
Resumo:
We investigate the nonlinear propagation of ultrashort pulses on resonant intersubband transitions in multiple semiconductor quantum wells. It is shown that the nonlinearity rooted from electron-electron interactions destroys the condition giving rise to self-induced transparency. However, by adjusting the area of input pulse, we find the signatures of self-induced transmission due to a full Rabi flopping of the electron density, and this phenomenon can be approximately interpreted by the traditional standard area theorem via defining the effective area of input pulse.
Resumo:
We investigate the characteristics of Gaussian beams reflected and transmitted from a uniaxial crystal slab with an arbitrary orientation of its optical axis. The formulas of the total electric and magnetic fields inside and outside the slab are derived by use of Maxwell's equations and by matching the boundary conditions at the interfaces. Numerical simulations are presented and the field values as well as the power densities are computed. Negative refractions are demonstrated when the beam is transmitted through a uniaxial crystal slab. Beam splitting of the reflected beam is observed and is explained by the resonant transmission for plane waves. Dependences of the lateral shift on the incident angle and beam width are discussed. Negative and positive lateral shifts are observed due to the spatial anisotropic properties.
Resumo:
A relação da qualidade da prática médica assistencial com os indicadores de saúde tem sido objeto de controvérsia. A possibilidade de avaliar o estado de saúde do recém-nascido em função do cuidado recebido, facilita o estudo desta relação, principalmente na área perinatal onde a expectativa é o nascimento de um bebê saudável ao final de uma gestação sem fatores de riscos acompanhados segundo as normas obstétricas vigentes. Neste estudo, examina-se a adequação do acompanhamento do trabalho de parto em uma maternidade pública do Estado do Rio de Janeiro, sob a ótica de avaliação de qualidade pela abordagem de processos e resultados através de critérios explícitos supondo que os fatores selecionados como componentes do processo de assistência ao trabalho de parto determinariam o resultado. Observa-se tais relações através da metodologia epidemiológica optando por um estudo caso-referente ou um estudo caso-controle, com definição primária da base. Selecionou-se como determinantes da qualidade da prática obstétrica intraparto a duração do trabalho de parto, percepção de alterações durante o trabalho de parto, prontidão para intervenção, número de exames realizados e intervalo entre o último exame e hora do parto. O resultado neonatal adverso caracterizou-se por óbito intra-útero, óbito neonatal e presença de um conjunto de sinais clínicos anormais no período neonatal imediato, com alto valor preditivo para o futuro dano neurológico. O risco de um resultado adverso foi estimado pela razão dos produtos cruzados aodds ratio (OR) numa população de 34 casos e 124 controles. A duração do trabalho de parto maior que doze horas esteve associada a um OR igual a 3,48 (1,28-9,43), idade da gestante, dilatação cervical do colo uterino à admissão e peso ao nascer modificaram o efeito desta associação, que também foi confundida pela paridade e pelo uso da ocitocina contrariando hipótese inicial. A percepção de alterações resultou num OR= 14,73 (4.24-54,27) e, à medida que o tempo de intervenção se prolongava os riscos aumentavam obedecendo a uma tendência linear. Discutem-se as dificuldades de aplicação metodologia epidemiológica ao campo da avaliação da qualidade, essencialmente no que se refere as exigências quantitativas, para garantir precisão e confiabilidade. A observação da interação e o controle do confundimento apontam o cuidado necessário nos trabalhos desta natureza para alcançar consistência e validade.
Resumo:
The relationship between transmission area of an object imaged and the visibility of correlated imaging is investigated in a lensless system. We show that they are not in simple inverse proportion, as usually depicted. The changes of the visibility will be quite different when the transmission area is varied by different manners, which may motivate people to seek a new understanding about the influence factors of the visibility. (C) 2007 Optical Society of America
Resumo:
Theoretically, we analyse the dispersion compensation characteristics of the chirped fibre grating (CFG) in an optical fibre cable television (CATV) system and obtain the analytic expression of the composite second-order (CSO) distortion using the time-domain form of the field envelope wave equation. The obtained result is in good agreement with the numerical simulation result. Experimentally, we verify the result by making use of the tunable characteristics of CFG to change the dispersion compensation amount and obtain an optimal CSO performance in a 125km fibre transmission link. Both the theoretical and experimental results show that the CSO performance can be improved by properly choosing the dispersion compensation amount for a certain fibre transmission link.
Resumo:
As feature size decreases, especially with the use of resolution enhancement technique, requirements for the coma aberrations in the projection lenses of the lithographic tools have become extremely severe. So, fast and accurate in situ measurement of coma is necessary. In the present paper, we present a new method for characterizing the coma aberrations in the projection lens using a phase-shifting mask and a transmission image sensor. By measuring the image positions at multiple NA and partial coherence settings, we are able to extract the coma aberration. The simulation results show that the accuracy of coma measurement increases approximately 20% compared to the previous straightforward measurement technique. (c) 2005 Elsevier GmbH. All rights reserved.
Resumo:
We describe the design, fabrication, and excellent performance of an optimized deep-etched high-density fused-silica transmission grating for use in dense wavelength division multiplexing (DWDM) systems. The fabricated optimized transmission grating exhibits an efficiency of 87.1% at a wavelength of 1550 nm. Inductively coupled plasma-etching technology was used to fabricate the grating. The deep-etched high-density fused-silica transmission grating is suitable for use in a DWDM system because of its high efficiency, low polarization-dependent loss, parallel demultiplexing, and stable optical performance. The fabricated deep-etched high-density fused-silica transmission gratings should play an important role in DWDM systems. (c) 2006 Optical Society of America.
Resumo:
The use of transmission matrices and lumped parameter models for describing continuous systems is the subject of this study. Non-uniform continuous systems which play important roles in practical vibration problems, e.g., torsional oscillations in bars, transverse bending vibrations of beams, etc., are of primary importance.
A new approach for deriving closed form transmission matrices is applied to several classes of non-uniform continuous segments of one dimensional and beam systems. A power series expansion method is presented for determining approximate transmission matrices of any order for segments of non-uniform systems whose solutions cannot be found in closed form. This direct series method is shown to give results comparable to those of the improved lumped parameter models for one dimensional systems.
Four types of lumped parameter models are evaluated on the basis of the uniform continuous one dimensional system by comparing the behavior of the frequency root errors. The lumped parameter models which are based upon a close fit to the low frequency approximation of the exact transmission matrix, at the segment level, are shown to be superior. On this basis an improved lumped parameter model is recommended for approximating non-uniform segments. This new model is compared to a uniform segment approximation and error curves are presented for systems whose areas very quadratically and linearly. The effect of varying segment lengths is investigated for one dimensional systems and results indicate very little improvement in comparison to the use of equal length segments. For purposes of completeness, a brief summary of various lumped parameter models and other techniques which have previously been used to approximate the uniform Bernoulli-Euler beam is a given.
Polaring beam splitter of two-layer dielectric rectangular transmission gratings in Littrow mounting