950 resultados para Noise - Loss hearing
Resumo:
In this Letter we numerically investigate the fault-tolerant threshold for optical cluster-state quantum computing. We allow both photon loss noise and depolarizing noise (as a general proxy for all local noise), and obtain a threshold region of allowed pairs of values for the two types of noise. Roughly speaking, our results show that scalable optical quantum computing is possible for photon loss probabilities < 3x10(-3), and for depolarization probabilities < 10(-4).
Resumo:
To investigate amblyopic contrast vision at threshold and above we performed pedestal-masking (contrastdiscrimination) experiments with a group of eight strabismic amblyopes using horizontal sinusoidal gratings (mainly 3 c/deg) in monocular, binocular and dichoptic configurations balanced across eye (i.e. five conditions). With some exceptions in some observers, the four main results were as follows. (1) For the monocular and dichoptic conditions, sensitivity was less in the amblyopic eye than in the good eye at all mask contrasts. (2) Binocular and monocular dipper functions superimposed in the good eye. (3) Monocular masking functions had a normal dipper shape in the good eye, but facilitation was diminished in the amblyopic eye. (4) A less consistent result was normal facilitation in dichoptic masking when testing the good eye, but a loss of this when testing the amblyopic eye. This pattern of amblyopic results was replicated in a normal observer by placing a neutral density filter in front of one eye. The two-stage model of binocular contrast gain control [Meese, T.S., Georgeson, M.A. & Baker, D.H. (2006). Binocular contrast vision at and above threshold. Journal of Vision 6, 1224--1243.] was `lesioned' in several ways to assess the form of the amblyopic deficit. The most successful model involves attenuation of signal and an increase in noise in the amblyopic eye, and intact stages of interocular suppression and binocular summation. This implies a behavioural influence from monocular noise in the amblyopic visual system as well as in normal observers with an ND filter over one eye.
Resumo:
Opticians and audiologists tend to see the same people. Many factors that are associated with poorer vision, whether hereditary, pre-natal, or post-natal, are also associated with poorer hearing. The most common factor is simply old age. According to the Royal National Institute for Deaf People (RNID), more than half of all people aged over 60 have some degree of hearing loss and are gradually losing their hearing as part of the ageing process – a process known as presbycusis.
Resumo:
This thesis is concerned with the optimising of hearing protector selection. A computer model was used to estimate the reduction in noise exposure and risk of occupational deafness provided by the wearing of hearing protectors in industrial noise spectra. The model was used to show that low attenuation hearing protectors con provide greater protection than high attenuation protectors if the high attenuation protectors ore not worn for the total duration of noise exposure; or not used by a small proportion of the population. The model was also used to show that high attenuation protectors will not necessarily provide significantly greater reduction in risk than low attenuation protectors if the population has been exposed to the noise for many years prior to the provision of hearing protectors. The effects of earplugs and earmuffs on the localisation of sounds were studied to determine whether high attenuation earmuffs are likely to have greater potential than the lower attenuation earplugs for affecting personal safety. Laboratory studies and experiments at a foundry with normal-hearing office employees and noise-exposed foundrymen who had some experience of wearing hearing protectors showed that although earplugs reduced the ability of the wearer to determine the direction of warning sounds, earmuffs produced more total angular error and more confusions between left and right. !t is concluded from the research findings that the key to the selection of hearing protectors is to be found in the provision of hearing protectors that can be worn for a very high percentage of the exposure time by a high percentage of the exposed population with the minimum effect on the personal safety of the wearers - the attenuation provided by the protection should be adequate but not a maximum value.
Illness perceptions and hearing difficulties in King-Kopetzky syndrome:what determines help seeking?
Resumo:
The present study explored illness perceptions of hearing difficulties amongst one hundred participants who reported experiencing hearing difficulties despite normal audiometric thresholds. This experience is referred to as King-Kopetzky syndrome (KKS), obscure auditory dysfunction (OAD), or auditory processing disorder (APD). Logistic regression was used to consider the associations between help-seeking and a range of audiological and illness perception measures. Results indicate that help-seekers present with poorer speech in noise thresholds than non help-seekers, and that coherent illness perceptions and a negative belief in the consequences of hearing difficulties are associated with help-seeking status, regardless of hearing sensitivity.
Resumo:
Aim - This pilot study uses qualitative methods to learn about the psycho-social needs of people who seek help with hearing loss. Background - There has been some emphasis in health policy to reduce the number of appointments required between assessment of hearing loss and fitting of hearing aids. This may respond to audiological needs but may not address the psycho-social needs. This study piloted a phenomenological approach to identify the patient's perspective. Methods - A phenomenological approach was taken to provide description of patient perspectives. Findings - Six patients reported that help-seeking was primarily influenced by the need to appease social partners and to improve hearing performance. Hearing aids were not regarded as acceptable treatments. Conclusions - Service providers need to consider the psycho-social consequences of hearing-aid issue alongside audiological needs.
Resumo:
Heterogeneous datasets arise naturally in most applications due to the use of a variety of sensors and measuring platforms. Such datasets can be heterogeneous in terms of the error characteristics and sensor models. Treating such data is most naturally accomplished using a Bayesian or model-based geostatistical approach; however, such methods generally scale rather badly with the size of dataset, and require computationally expensive Monte Carlo based inference. Recently within the machine learning and spatial statistics communities many papers have explored the potential of reduced rank representations of the covariance matrix, often referred to as projected or fixed rank approaches. In such methods the covariance function of the posterior process is represented by a reduced rank approximation which is chosen such that there is minimal information loss. In this paper a sequential Bayesian framework for inference in such projected processes is presented. The observations are considered one at a time which avoids the need for high dimensional integrals typically required in a Bayesian approach. A C++ library, gptk, which is part of the INTAMAP web service, is introduced which implements projected, sequential estimation and adds several novel features. In particular the library includes the ability to use a generic observation operator, or sensor model, to permit data fusion. It is also possible to cope with a range of observation error characteristics, including non-Gaussian observation errors. Inference for the covariance parameters is explored, including the impact of the projected process approximation on likelihood profiles. We illustrate the projected sequential method in application to synthetic and real datasets. Limitations and extensions are discussed. © 2010 Elsevier Ltd.
Resumo:
College personnel are required to provide accommodations for students who are deaf and hard of hearing (D/HoH), but few empirical studies have been conducted on D/HoH students as they learn under the various accommodation conditions (sign language interpreting, SLI, real-time captioning, RTC, and both). Guided by the experiences of students who are D/HoH at Miami-Dade College (MDC) who requested RTC in addition to SLI as accommodations, the researcher adopted Merten’s transformative-emancipatory theoretical framework that values perceptions and voice of students who are D/HoH. A mixed methods design addressed two research questions: Did student learning differ for each accommodation? What did students experience while learning through accommodations? Participants included 30 students who were D/HoH (60% women). They represented MDC’s majority minority population: 10% White (non-Hispanic), 20% Black (non-Hispanic, including Haitian/Caribbean), 67% Hispanic, and 3% other. Hearing loss, ranged from severe-profound (70%) to mild-moderate (30%). All were able to communicate with American Sign Language: Learning was measured while students who were D/HoH viewed three lectures under three accommodation conditions (SLI, RTC, SLI+RTC). The learning measure was defined as the difference in pre- and post-test scores on tests of the content presented in the lectures. Using repeated measure ANOVA and ANCOVA, confounding variables of fluency in American Sign Language and literacy skills were treated as covariates. Perceptions were obtained through interviews and verbal protocol analysis that were signed, videotaped, transcribed, coded, and examined for common themes and metacognitive strategies. No statistically significant differences were found among the three accommodations on the learning measure. Students who were D/HoH expressed thoughts about five different aspects of their learning while they viewed lectures: (a) comprehending the information, (b) feeling a part of the classroom environment, (c) past experiences with an accommodation, (d) individual preferences for an accommodation, (e) suggestions for improving an accommodation. They exhibited three metacognitive strategies: (a) constructing knowledge, (b) monitoring comprehension, and (c) evaluating information. No patterns were found in the types of metacognitive strategies used for any particular accommodation. The researcher offers recommendations for flexible applications of the standard accommodations used with students who are D/HoH.
Resumo:
This thesis presents and discusses the results of ambient seismic noise correlation for two different environments: intraplate and Mid-Atlantic Ridge. The coda wave interferometry method has also been tested for the intraplate data. Ambient noise correlation is a method that allows to retrieve the structural response between two receivers from ambient noise records, as if one of the station was a virtual source. It has been largely used in seismology to image the subsurface and to monitor structural changes associated mostly with volcanic eruptions and large earthquakes. In the intraplate study, we were able to detect localized structural changes related to a small earthquake swarm, which main event is mR 3.7, North-East of Brazil. We also showed that the 1-bit normalization and spectral whitening result on the loss of waveform details and that the phase auto-correlation, which is amplitude unbiased, seems to be more sensitive and robust for our analysis of a small earthquake swarm. The analysis of 6 months of data using cross-correlations detect clear medium changes soon after the main event while the auto-correlations detect changes essentially after 1 month. It could be explained by fluid pressure redistribution which can be initiated by hydromechanical changes and opened path ways to shallower depth levels due to later occurring earthquakes. In the Mid-Atlantic Ridge study, we investigate structural changes associated with a mb 4.9 earthquake in the region of the Saint Paul transform fault. The data have been recorded by a single broadband seismic station located at less than 200 km from the Mid-Atlantic ridge. The results of the phase auto-correlation for a 5-month period, show a strong co-seismic medium change followed by a relatively fast post-seismic recovery. This medium change is likely related to the damages caused by the earthquake’s ground shaking. The healing process (filling of the new cracks) that lasted 60 days can be decomposed in two phases, a fast recovery (70% in ~30 days) in the early post-seismic stage and a relatively slow recovery later (30% in ~30 days). In the coda wave interferometry study, we monitor temporal changes of the subsurface caused by the small intraplate earthquake swarm mentioned previously. The method was first validated with synthetics data. We were able to detect a change of 2.5% in the source position and a 15% decrease of the scatterers’ amount. Then, from the real data, we observed a rapid decorrelation of the seismic coda after the mR 3.7 seismic event. This indicates a rapid change of the subsurface in the fault’s region induced by the earthquake.
Resumo:
This thesis presents and discusses the results of ambient seismic noise correlation for two different environments: intraplate and Mid-Atlantic Ridge. The coda wave interferometry method has also been tested for the intraplate data. Ambient noise correlation is a method that allows to retrieve the structural response between two receivers from ambient noise records, as if one of the station was a virtual source. It has been largely used in seismology to image the subsurface and to monitor structural changes associated mostly with volcanic eruptions and large earthquakes. In the intraplate study, we were able to detect localized structural changes related to a small earthquake swarm, which main event is mR 3.7, North-East of Brazil. We also showed that the 1-bit normalization and spectral whitening result on the loss of waveform details and that the phase auto-correlation, which is amplitude unbiased, seems to be more sensitive and robust for our analysis of a small earthquake swarm. The analysis of 6 months of data using cross-correlations detect clear medium changes soon after the main event while the auto-correlations detect changes essentially after 1 month. It could be explained by fluid pressure redistribution which can be initiated by hydromechanical changes and opened path ways to shallower depth levels due to later occurring earthquakes. In the Mid-Atlantic Ridge study, we investigate structural changes associated with a mb 4.9 earthquake in the region of the Saint Paul transform fault. The data have been recorded by a single broadband seismic station located at less than 200 km from the Mid-Atlantic ridge. The results of the phase auto-correlation for a 5-month period, show a strong co-seismic medium change followed by a relatively fast post-seismic recovery. This medium change is likely related to the damages caused by the earthquake’s ground shaking. The healing process (filling of the new cracks) that lasted 60 days can be decomposed in two phases, a fast recovery (70% in ~30 days) in the early post-seismic stage and a relatively slow recovery later (30% in ~30 days). In the coda wave interferometry study, we monitor temporal changes of the subsurface caused by the small intraplate earthquake swarm mentioned previously. The method was first validated with synthetics data. We were able to detect a change of 2.5% in the source position and a 15% decrease of the scatterers’ amount. Then, from the real data, we observed a rapid decorrelation of the seismic coda after the mR 3.7 seismic event. This indicates a rapid change of the subsurface in the fault’s region induced by the earthquake.
Resumo:
Introduction: This study reviews the cases of stapedotomy and evaluates its effectiveness at improving hearing loss in patients with otosclerosis. Materials and methods: Retrospective review of patients’ records who had clinical and audiometric diagnosis of otosclerosis from January to December 2012. Results: A total of 54 stapedotomy surgeries (52 unilateral and 1 bilateral surgeries) were received. Average post-operative ABG for 0.5, 1, 2 and 4 KHz showed that 61.1% had complete closure of ABG (ABG < 10 dB) compared with 1.6% preoperatively and 85.2% had closure of ABG to within 20dB compared with 4.7% preoperatively (t – 13.89, p = 0.000). More than 94% had hearing improvement and 81.5% had ABG closure greater than 10 dB postoperatively (mean gain 23.38 ± 12.37, t = 13.89, p = 0.000). A total of 13% complications were recorded with TM perforation (5.6%) being the commonest complication. Conclusion: Stapedotomy is an effective surgical procedure for the treatment of otosclerosis which leads to improvement in patients’ quality of life. A favorable hearing outcome can be obtained by the combination of experienced hands with minimal surgical trauma and appropriate surgical technique.
Resumo:
El presente trabajo se realizó en una Planta de Hormigón Asfáltico, donde se realizó el estudio del ruido como factor de riesgo bajo las perspectivas de: Salud Ocupacional, Seguridad e Higiene Industrial. Este enfoque holístico, define la influencia que éste riesgo laboral ejerce sobre la pérdida de agudeza auditiva. Se estableció inicialmente el marco teórico y legal vigente sobre el ruido, posteriormente se describió la metodología de estudio, operatividad de variables, y la muestra a estudiar. Luego se procedió a la caracterización de la población y área estudiada, así como las actividades productivas. Dentro de la Higiene Industrial, se monitoreó la exposición del nivel de presión sonora, se realizó el comparativo con el nivel permisible (TWA 8 horas) establecido en el “Reglamento de Seguridad y Salud de los Trabajadores”, D.E. 2393. En términos de Seguridad Industrial, se analizó el equipo de protección personal EPP utilizado, y las variables determinantes. En el ámbito de Salud Ocupacional, se estudió: características personales de trabajadores, patologías relacionadas con sordera, y un cuestionario de exposición al ruido. Finalmente se determinó la existencia de sobreexposición a ruido laboral en la empresa objeto de estudio, mediante el estudio del estado de salud auditiva de los colaboradores se determinó la gran incidencia de personal sano y finalmente se determinó las medidas de control a implementarse enfatizadas a la realidad descubierta en el presente estudio, las que incluyen cambios en equipos y maquinaria, buenas prácticas de trabajo, planes de adiestramiento y capacitación en todo el personal entre otros.
Resumo:
BACKGROUND: The genetic basis of hearing loss in humans is relatively poorly understood. In recent years, experimental approaches including laboratory studies of early onset hearing loss in inbred mouse strains, or proteomic analyses of hair cells or hair bundles, have suggested new candidate molecules involved in hearing function. However, the relevance of these genes/gene products to hearing function in humans remains unknown. We investigated whether single nucleotide polymorphisms (SNPs) in the human orthologues of genes of interest arising from the above-mentioned studies correlate with hearing function in children. METHODS: 577 SNPs from 13 genes were each analysed by linear regression against averaged high (3, 4 and 8 kHz) or low frequency (0.5, 1 and 2 kHz) audiometry data from 4970 children in the Avon Longitudinal Study of Parents and Children (ALSPAC) birth-cohort at age eleven years. Genes found to contain SNPs with low p-values were then investigated in 3417 adults in the G-EAR study of hearing. RESULTS: Genotypic data were available in ALSPAC for a total of 577 SNPs from 13 genes of interest. Two SNPs approached sample-wide significance (pre-specified at p = 0.00014): rs12959910 in CBP80/20-dependent translation initiation factor (CTIF) for averaged high frequency hearing (p = 0.00079, β = 0.61 dB per minor allele); and rs10492452 in L-plastin (LCP1) for averaged low frequency hearing (p = 0.00056, β = 0.45 dB). For low frequencies, rs9567638 in LCP1 also enhanced hearing in females (p = 0.0011, β = -1.76 dB; males p = 0.23, β = 0.61 dB, likelihood-ratio test p = 0.006). SNPs in LCP1 and CTIF were then examined against low and high frequency hearing data for adults in G-EAR. Although the ALSPAC results were not replicated, a SNP in LCP1, rs17601960, is in strong LD with rs9967638, and was associated with enhanced low frequency hearing in adult females in G-EAR (p = 0.00084). CONCLUSIONS: There was evidence to suggest that multiple SNPs in CTIF may contribute a small detrimental effect to hearing, and that a sex-specific locus in LCP1 is protective of hearing. No individual SNPs reached sample-wide significance in both ALSPAC and G-EAR. This is the first report of a possible association between LCP1 and hearing function.