920 resultados para Neonatal Intensive Care Unit
Resumo:
The patient safety is a major concern in health services for its global dimension, as evidenced by the fragility of care processes that predispose an occurrence of adverse events. These events in a neonatal intensive care unit are considered serious and hazardous to lives of newborns. The present study aimed to identify and analyze adverse events in a neonatal intensive care unit based in Trigger Tool. It is an epidemiological, cross-sectional , exploratory, retrospective study with quantitative, descriptive and analytical approach, performed in 2015 at a school hospital. The sample was not probabilistic, involving 116 newborns who met the eligibility criteria. Data collection was performed by retrospective review of medical records, using a specific kind of "trigger" instrument, composed of sentinel events in neonatology, adapted from the American model used by the Vermont-Oxford Network. Data were analyzed using descriptive and inferential statistics. The chi-square test for linear trend was used to assess the associations between the variables of interest. The research received a favorable agreement from Ethics Committee of the Federal University of Rio Grande do Norte, under number 1055533, and Presentation Certificate for Ethics Assessment 43894515.6.0000.5537. The results show among investigated newborns, 110 experienced at least one adverse event during their stay, with a total of 391 medical records analyzed and rate of 3.37 events per patient. Prevailed the preterm newborns with low birth weight, from mother who had hypertensive diseases during pregnancy and urinary tract infection. The average hospitalization time was 25 days, associated with hospital-acquired infections events (p = 0.01). Among the identified adverse events stood out the events related to thermoregulation disorders (39.0%), with prevalence of hypothermia (26.0%), followed by health care-related infections (16.4%) and blood glucose disorders, hypoglycemia (9.00%) and hyperglycemia (6.64%). Most of these incidents were classified in categories E and F, which represents that there was damage small proportion. Due to these damages come from the care practice with newborn, 78% were classified as avoidable. There was statistically significant association between the variable birth weight with infections (p = 0.006) as well as peri/intraventricular bleeding (p = 0.02), hypoglycemia (p = 0.021), hyperglycemia (p = 0.001), hyperthermia (p = 0.39) and death (p=0,02). Gestational age was associated with seizures (p = 0.002), hyperglycemia (p=0.017) e hyperthermia (p=0.027). The security institution culture was reported by the health workers as intermediate, even though the number of adverse events found in only one unit of service indicates that there is much to be done. Thus the high rate of adverse events identified in the neonatal intensive care unit reinforces the necessity to elaborate specific preventive strategies for this risk environment.
Resumo:
The patient safety is a major concern in health services for its global dimension, as evidenced by the fragility of care processes that predispose an occurrence of adverse events. These events in a neonatal intensive care unit are considered serious and hazardous to lives of newborns. The present study aimed to identify and analyze adverse events in a neonatal intensive care unit based in Trigger Tool. It is an epidemiological, cross-sectional , exploratory, retrospective study with quantitative, descriptive and analytical approach, performed in 2015 at a school hospital. The sample was not probabilistic, involving 116 newborns who met the eligibility criteria. Data collection was performed by retrospective review of medical records, using a specific kind of "trigger" instrument, composed of sentinel events in neonatology, adapted from the American model used by the Vermont-Oxford Network. Data were analyzed using descriptive and inferential statistics. The chi-square test for linear trend was used to assess the associations between the variables of interest. The research received a favorable agreement from Ethics Committee of the Federal University of Rio Grande do Norte, under number 1055533, and Presentation Certificate for Ethics Assessment 43894515.6.0000.5537. The results show among investigated newborns, 110 experienced at least one adverse event during their stay, with a total of 391 medical records analyzed and rate of 3.37 events per patient. Prevailed the preterm newborns with low birth weight, from mother who had hypertensive diseases during pregnancy and urinary tract infection. The average hospitalization time was 25 days, associated with hospital-acquired infections events (p = 0.01). Among the identified adverse events stood out the events related to thermoregulation disorders (39.0%), with prevalence of hypothermia (26.0%), followed by health care-related infections (16.4%) and blood glucose disorders, hypoglycemia (9.00%) and hyperglycemia (6.64%). Most of these incidents were classified in categories E and F, which represents that there was damage small proportion. Due to these damages come from the care practice with newborn, 78% were classified as avoidable. There was statistically significant association between the variable birth weight with infections (p = 0.006) as well as peri/intraventricular bleeding (p = 0.02), hypoglycemia (p = 0.021), hyperglycemia (p = 0.001), hyperthermia (p = 0.39) and death (p=0,02). Gestational age was associated with seizures (p = 0.002), hyperglycemia (p=0.017) e hyperthermia (p=0.027). The security institution culture was reported by the health workers as intermediate, even though the number of adverse events found in only one unit of service indicates that there is much to be done. Thus the high rate of adverse events identified in the neonatal intensive care unit reinforces the necessity to elaborate specific preventive strategies for this risk environment.
Resumo:
BACKGROUND: Fluid resuscitation is a cornerstone of intensive care treatment, yet there is a lack of agreement on how various types of fluids should be used in critically ill patients with different disease states. Therefore, our goal was to investigate the practice patterns of fluid utilization for resuscitation of adult patients in intensive care units (ICUs) within the USA. METHODS: We conducted a cross-sectional online survey of 502 physicians practicing in medical and surgical ICUs. Survey questions were designed to assess clinical decision-making processes for 3 types of patients who need volume expansion: (1) not bleeding and not septic, (2) bleeding but not septic, (3) requiring resuscitation for sepsis. First-choice fluid used in fluid boluses for these 3 patient types was requested from the respondents. Descriptive statistics were performed using a Kruskal-Wallis test to evaluate differences among the physician groups. Follow-up tests, including t tests, were conducted to evaluate differences between ICU types, hospital settings, and bolus volume. RESULTS: Fluid resuscitation varied with respect to preferences for the factors to determine volume status and preferences for fluid types. The 3 most frequently preferred volume indicators were blood pressure, urine output, and central venous pressure. Regardless of the patient type, the most preferred fluid type was crystalloid, followed by 5 % albumin and then 6 % hydroxyethyl starches (HES) 450/0.70 and 6 % HES 600/0.75. Surprisingly, up to 10 % of physicians still chose HES as the first choice of fluid for resuscitation in sepsis. The clinical specialty and the practice setting of the treating physicians also influenced fluid choices. CONCLUSIONS: Practice patterns of fluid resuscitation varied in the USA, depending on patient characteristics, clinical specialties, and practice settings of the treating physicians.
Improving the care of preterm infants: before, during, and after, stabilisation in the delivery room
Resumo:
Introduction Up to 10% of infants require stabilisation during transition to extrauterine life. Enhanced monitoring of cardiorespiratory parameters during this time may improve stabilisation outcomes. In addition, technology may facilitate improved preparation for delivery room stabilisation as well as NICU procedures, through educational techniques. Aim To improve infant care 1) before birth via improved training, 2) during stabilisation via enhanced physiological monitoring and improved practice, and 3) after delivery, in the neonatal intensive care unit (NICU), via improved procedural care. Methods A multifaceted approach was utilised including; a combination of questionnaire based surveys, mannequin-based investigations, prospective observational investigations, and a randomised controlled trial involving preterm infants less than 32 weeks in the delivery room. Forms of technology utilised included; different types of mannequins including a CO2 producing mannequin, qualitative end tidal CO2 (EtCO2) detectors, a bespoke quantitative EtCO2 detector, and annotated videos of infant stabilisation as well as NICU procedures Results Manual ventilation improved with the use of EtCO2 detection, and was positively assessed by trainees. Quantitative EtCO2 detection in the delivery room is feasible, EtCO2 increased over the first 4 minutes of life in preterm infants, and EtCO2 was higher in preterm infants who were intubated. Current methods of heart rate assessment were found to be unreliable. Electrocardiography (ECG) application warrants further evaluation. Perfusion index (PI) monitoring utilised in the delivery room was feasible. Video recording technology was utilised in several ways. This technology has many potential benefits, including debriefing and coaching in procedural healthcare, and warrants further evaluation. Parents would welcome the introduction of webcams in the NICU. Conclusions I have evaluated new methods of improving infant care before, during, and after stabilisation in the DR. Specifically, I have developed novel educational tools to facilitate training, and evaluated EtCO2, PI, and ECG during infant stabilisation. I have identified barriers in using webcams in the NICU, to now be addressed prior to webcam implementation.
Resumo:
Brain injury due to lack of oxygen or impaired blood flow around the time of birth, may cause long term neurological dysfunction or death in severe cases. The treatments need to be initiated as soon as possible and tailored according to the nature of the injury to achieve best outcomes. The Electroencephalogram (EEG) currently provides the best insight into neurological activities. However, its interpretation presents formidable challenge for the neurophsiologists. Moreover, such expertise is not widely available particularly around the clock in a typical busy Neonatal Intensive Care Unit (NICU). Therefore, an automated computerized system for detecting and grading the severity of brain injuries could be of great help for medical staff to diagnose and then initiate on-time treatments. In this study, automated systems for detection of neonatal seizures and grading the severity of Hypoxic-Ischemic Encephalopathy (HIE) using EEG and Heart Rate (HR) signals are presented. It is well known that there is a lot of contextual and temporal information present in the EEG and HR signals if examined at longer time scale. The systems developed in the past, exploited this information either at very early stage of the system without any intelligent block or at very later stage where presence of such information is much reduced. This work has particularly focused on the development of a system that can incorporate the contextual information at the middle (classifier) level. This is achieved by using dynamic classifiers that are able to process the sequences of feature vectors rather than only one feature vector at a time.
Resumo:
Background and Objectives: Both psychiatric acute units and psychiatric intensive care units (PICUs) focus on acute treatment of behavioral disturbances such as violence and aggressive threats and acts. The aim of the present study is to describe the frequency of violent behavior; such as verbal or physical threats and physical attacks, among patients admitted to psychiatric intensive care unit (PICU). In addition the relationship between the episodes of threats and/or attacks in relation to time of the day, days of the week, and their seasonal variations was explored. Methods: All violent behavior was continuously assessed at the psychiatric emergency department. Data were collected during the period from May 2010 to May 2012. Results: Patients with only one hospitalization were less violent than those who have had two hospitalizations. There was a statistically significant difference in violence among patients without formal secondary education and those who have not formal education. Violent behavior showed two peaks during the day; the first occurring at 1 pm and the second at 8 pm. In regard to seasonality, summer had a higher incidence of violence. The most peaceful seasons of the year were spring and autumn. Conclusions: Violent behavior shows variation in daytime, days of the week and season in acute psychiatric intensive care. Daytime variation shows two peaks of violence at 1 pm and 8 pm, Sundays and Wednesdays being the quietest days regarding violence both in winter and summer. Patient's level of education and hospitalization status partially explain the variation.
Resumo:
Introduction: Patients who survive an intensive care unit admission frequently suffer physical and psychological morbidity for many months after discharge. Current rehabilitation pathways are often fragmented and little is known about the optimum method of promoting recovery. Many patients suffer reduced quality of life. Methods and analysis: The authors plan a multicentre randomised parallel group complex intervention trial with concealment of group allocation from outcome assessors. Patients who required more than 48 h of mechanical ventilation and are deemed fit for intensive care unit discharge will be eligible. Patients with primary neurological diagnoses will be excluded. Participants will be randomised into one of the two groups: the intervention group will receive standard ward-based care delivered by the NHS service with additional treatment by a specifically trained generic rehabilitation assistant during ward stay and via telephone contact after hospital discharge and the control group will receive standard ward-based care delivered by the current NHS service. The intervention group will also receive additional information about their critical illness and access to a critical care physician. The total duration of the intervention will be from randomisation to 3 months postrandomisation. The total duration of follow-up will be 12 months from randomisation for both groups. The primary outcome will be the Rivermead Mobility Index at 3 months. Secondary outcomes will include measures of physical and psychological morbidity and function, quality of life and survival over a 12-month period. A health economic evaluation will also be undertaken. Groups will be compared in relation to primary and secondary outcomes; quantitative analyses will be supplemented by focus groups with patients, carers and healthcare workers. Ethics and dissemination: Consent will be obtained from patients and relatives according to patient capacity. Data will be analysed according to a predefined analysis plan.
Resumo:
Background. The value of respiratory variables as weaning predictors in the intensive care unit (ICU) is controversial. We evaluated the ability of tidal volume (Vtexp), respiratory rate ( f ), minute volume (MVexp), rapid shallow breathing index ( f/Vt), inspired–expired oxygen concentration difference [(I–E)O2], and end-tidal carbon dioxide concentration (PE′CO2) at the end of a weaning trial to predict early weaning outcomes. Methods. Seventy-three patients who required .24 h of mechanical ventilation were studied. A controlled pressure support weaning trial was undertaken until 5 cm H2O continuous positive airway pressure or predefined criteria were reached. The ability of data from the last 5 min of the trial to predict whether a predefined endpoint indicating discontinuation of ventilator support within the next 24 h was evaluated. Results. Pre-test probability for achieving the outcome was 44% in the cohort (n¼32). Non-achievers were older, had higher APACHE II and organ failure scores before the trial, and higher baseline arterial H+ concentrations. The Vt, MV, f, and f/Vt had no predictive power using a range of cut-off values or from receiver operating characteristic (ROC) analysis. The [I–E]O2 and PE′CO2 had weak discriminatory power [areaunder the ROC curve: [I–E]O2 0.64 (P¼0.03); PE′CO2 0.63 (P¼0.05)]. Using best cut-off values for [I–E]O2 of 5.6% and PE′CO2 of 5.1 kPa, positive and negative likelihood ratios were 2 and 0.5, respectively, which only changed the pre- to post-test probability by about 20%. Conclusions. In unselected ICU patients, respiratory variables predict early weaning from mechanical ventilation poorly.
Resumo:
Background False-positive blood cultures findings may lead to a falsely increased morbidity and increased hospital costs. Method The survey was conducted as retrospective - prospective study and included 239 preterm infants (born before 37 weeks of gestation) who were treated in Neonatal Intensive Care Unit (NICU) in Institute for Child and Youth Health Care of Vojvodina during one year (January 1st, 2012 to December 31st, 2012). The retrospective part of the study focused on examination of incidence of neonatal sepsis and determination of risk factors. In the prospective part of the study infants were sub-divided into two groups: Group 1- infants hospitalized in NICU during the first 6 months of the study; blood cultures were taken by the ‘’clean technique’’ and checklists for this procedure were not taken. Group 2- neonates hospitalized in NICU during last 6 months of the study; blood cultures were taken by ‘’sterile technique’’ and checklists for this procedure were taken. Results The main risk factors for sepsis were prelabor rupture of membranes, low gestational age, low birth weight, mechanical ventilation, umbilical venous catheter placement, and abdominal drainage. Staphylococcus aureus and coagulase negative Staphylococcus were the most frequently isolated microorganisms in false-positive blood samples. Conclusions Education of employees, use of checklists and sterile sets for blood sampling, permanent control of false positive blood cultures, as well as regular and routine monthly reports are crucial for successful reduction of contamination rates.
Resumo:
Neonatal seizures are common in the neonatal intensive care unit. Clinicians treat these seizures with several anti-epileptic drugs (AEDs) to reduce seizures in a neonate. Current AEDs exhibit sub-optimal efficacy and several randomized control trials (RCT) of novel AEDs are planned. The aim of this study was to measure the influence of trial design on the required sample size of a RCT. We used seizure time courses from 41 term neonates with hypoxic ischaemic encephalopathy to build seizure treatment trial simulations. We used five outcome measures, three AED protocols, eight treatment delays from seizure onset (Td) and four levels of trial AED efficacy to simulate different RCTs. We performed power calculations for each RCT design and analysed the resultant sample size. We also assessed the rate of false positives, or placebo effect, in typical uncontrolled studies. We found that the false positive rate ranged from 5 to 85% of patients depending on RCT design. For controlled trials, the choice of outcome measure had the largest effect on sample size with median differences of 30.7 fold (IQR: 13.7–40.0) across a range of AED protocols, Td and trial AED efficacy (p<0.001). RCTs that compared the trial AED with positive controls required sample sizes with a median fold increase of 3.2 (IQR: 1.9–11.9; p<0.001). Delays in AED administration from seizure onset also increased the required sample size 2.1 fold (IQR: 1.7–2.9; p<0.001). Subgroup analysis showed that RCTs in neonates treated with hypothermia required a median fold increase in sample size of 2.6 (IQR: 2.4–3.0) compared to trials in normothermic neonates (p<0.001). These results show that RCT design has a profound influence on the required sample size. Trials that use a control group, appropriate outcome measure, and control for differences in Td between groups in analysis will be valid and minimise sample size.
Resumo:
Waiting time at an intensive care unity stands for a key feature in the assessment of healthcare quality. Nevertheless, its estimation is a difficult task, not only due to the different factors with intricate relations among them, but also with respect to the available data, which may be incomplete, self-contradictory or even unknown. However, its prediction not only improves the patients’ satisfaction but also enhance the quality of the healthcare being provided. To fulfill this goal, this work aims at the development of a decision support system that allows one to predict how long a patient should remain at an emergency unit, having into consideration all the remarks that were just stated above. It is built on top of a Logic Programming approach to knowledge representation and reasoning, complemented with a Case Base approach to computing.
Resumo:
As a matter of fact, an Intensive Care Unit (ICU) stands for a hospital facility where patients require close observation and monitoring. Indeed, predicting Length-of-Stay (LoS) at ICUs is essential not only to provide them with improved Quality-of-Care, but also to help the hospital management to cope with hospital resources. Therefore, in this work one`s aim is to present an Artificial Intelligence based Decision Support System to assist on the prediction of LoS at ICUs, which will be centered on a formal framework based on a Logic Programming acquaintance for knowledge representation and reasoning, complemented with a Case Based approach to computing, and able to handle unknown, incomplete, or even contradictory data, information or knowledge.
Resumo:
This study was the first conducted in Brazil to evaluate the presence of Enterobacter sakazakii in milk-based powdered infant formula manufactured for infants 0 to 6 months of age and to examine the conditions of formula preparation and service in three hospitals in Sao Paulo State, Brazil. Samples of dried and rehydrated infant formula, environments of milk kitchens, water, bottles and nipples, utensils, and hands of personnel were analyzed, and E. sakazakii and Enterobacteriaceae populations were determined. All samples of powdered infant formula purchased at retail contained E. sakazakii at <0.03 most probable number (MPN)/100 g. In hospital samples, E. sakazakii was found in one unopened formula can (0.3 MPN/100 g) and in the residue from one nursing bottle from hospital A. All other cans of formula from the same lot bought at a retail store contained E. sakazakii at <0.03 MPN/100 g. The pathogen also was found in one cleaning sponge from hospital B. Enterobacteriaceae populations ranged from 10(1) to 10(5) CFU/g in cleaning aids and <5 CFU/g in all formula types (dry or rehydrated), except for the sample that contained E. sakazakii, which also was contaminated with Enterobacteriaceae at 5 CFU/g. E. sakazakii isolates were not genetically related. In an experiment in which rehydrated formula was used as the growth medium, the temperature was that of the neonatal intensive care unit (25 C), and the incubation time was the average time that formula is left at room temperature while feeding the babies (up to 4 h), a 2-log increase in levels of E. sakazakii was found in the formula. Visual inspection of the facilities revealed that the hygienic conditions in the milk kitchens needed improvement. The length of time that formula is left at room temperature in the different hospitals while the babies in the neonatal intensive care unit are being fed (up to 4 h) may allow for the multiplication of E. sakazakii and thus may lead to an increased health risk for infants.
Resumo:
This study was designed to investigate the feasibility of applying tone-ABRs in the nursery and neonatal intensive care unit (NICU), and to provide normative tone-ABR data from neonates. Normative tone-ABR latency data were determined. The study obtained intensity series of tone-ABRs from thirty preterm neonates and twenty fullterm neonates who had confirmed normal peripheral auditory function after passing both an OAE and ABR screening examination. ABRs were collected in response to 500, 1500, and 4000 Hz tone bursts at 70, 50, 30, and 20 dB nHL. Mean wave V latencies were compared between groups, ears, and by gender. Responses to tone bursts of 20 and 30 dB nHL were detected in 97% and 100% of all ears respectively, in addition to responses to the higher-intensity stimuli. Preterm neonates` ABRs showed significantly longer latencies than those of the full-term infants. Tone-ABR evaluation was found to be both feasible and reliable as a measure of auditory function in neonates.
Resumo:
To compare presence and severity of clinical symptoms of anxiety, dysphoria, and depression in mothers of preterm and of full-term infants and to observe changes in symptoms of mothers of preterm infants during hospitalization of the infants and after discharge, 50 mothers of preterm infants and 25 mothers of full-term infants completed the State-Trait Anxiety Inventory and the Beck Depression Inventory. The mothers with preterm infants had significantly higher clinical symptoms of State Anxiety during hospitalization than the group with full-term infants, but the clinical symptoms of anxiety in mothers of preterm infants decreased significantly after discharge. The health staff in a neonatal intensive care unit should not only be aware of infants` clinical status but also of the mothers` emotional state.