965 resultados para NEAR-INFRARED OBSERVATIONS


Relevância:

100.00% 100.00%

Publicador:

Resumo:

We report on the nonlinear (NL) optical properties of glassy TeO2-GeO2-K2O-Bi2O3 at lambda = 800 nm and lambda = 1,064 nm. Using the Kerr gate technique with a laser delivering 150 fs pulses at 800 nm, we demonstrated the fast NL response of the samples. The modulus of the NL refractive index, n (2), at 800 nm was similar to 10(-15) cm(2)/W. The Z-scan technique was used to determine n (2) a parts per thousand +10(-15) cm(2)/W, at 1,064 nm with pulses of 17 ps. The two-photon absorption coefficient, alpha (2), was smaller than the minimum that we can measure (< 0.003 cm/GW). The figure of merit n (2)/alpha (2) lambda was calculated and indicates that this glass composition has large potential to be used for all-optical switching.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Purpose: Dynamic near infrared fluorescence imaging of the urinary tract provides a promising way to diagnose ureteropelvic junction obstruction. Initial studies demonstrated the ability to visualize urine flow and peristalsis in great detail. We analyzed the efficacy of near infrared imaging in evaluating ureteropelvic junction obstruction, renal involvement and the anatomical detail provided compared to conventional imaging modalities. Materials and Methods: Ten swine underwent partial or complete unilateral ureteral obstruction. Groups were survived for the short or the long term. Imaging was performed with mercaptoacetyltriglycine diuretic renogram, magnetic resonance urogram, excretory urogram, ultrasound and near infrared imaging. Scoring systems for ureteropelvic junction obstruction were developed for magnetic resonance urogram and near infrared imaging. Physicians and medical students graded ureteropelvic junction obstruction based on magnetic resonance urogram and near infrared imaging results. Results: Markers of vascular and urinary dynamics were quantitatively consistent among control renal units. The same markers were abnormal in obstructed renal units with significantly different times of renal phase peak, start of pelvic phase and start of renal uptake. Such parameters were consistent with those obtained with mercaptoacetyltriglycine diuretic renography. Near infrared imaging provided live imaging of urinary flow, which was helpful in identifying the area of obstruction for surgical planning. Physicians and medical students categorized the degree of obstruction appropriately for fluorescence imaging and magnetic resonance urogram. Conclusions: Near infrared imaging offers a feasible way to obtain live, dynamic images of urine flow and ureteral peristalsis. Qualitative and quantitative parameters were comparable to those of conventional imaging. Findings support fluorescence imaging as an accurate, easy to use method of diagnosing ureteropelvic junction obstruction.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The Nd3+-Yb3+ couple was investigated in fluoroindogallate glasses using optical spectroscopy to elucidate the energy transfer mechanisms involved in the downconversion (DC) process. Upon excitation of a Nd3+ ion by an ultraviolet photon, DC through a three-step energy transfer process occurs, in which the energy of the ultraviolet photon absorbed by the Nd3+ ion is converted into three infrared photons emitted by Yb3+ ions, i.e. quantum cutting (QC). In addition, with excitation in the visible, our results confirm that the DC process occurs through a one-step energy transfer process, in which the energy of a visible photon absorbed by the Nd3+ ion is converted into only one infrared photon emitted by an Yb3+ ion. Time-resolved measurements enabled the estimation of the efficiencies of the cross-relaxation processes between Nd3+ and Yb3+ ions.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Phase 1: To validate Near-Infrared Reflectance Analysis (NIRA) as a fast, reliable and suitable method for routine evaluation of human milk’s nitrogen and fat content. Phase 2: To determine whether fat content, protein content and osmolality of HM before and after fortification may affect gastroesophageal reflux (GER) in symptomatic preterm infants. Patients and Methods: Phase 1: 124 samples of expressed human milk (55 from preterm mothers and 69 from term mothers) were used to validate NIRA against traditional methods (Gerber method for fat and Kjeldhal method for nitrogen). Phase 2: GER was evaluated in 17 symptomatic preterm newborns fed naïve and fortified HM by combined pH/intraluminal-impedance monitoring (pH-MII). HM fat and protein content was analysed by a Near-Infrared-Reflectance-Analysis (NIRA). HM osmolality was tested before and after fortification. GER indexes measured before and after fortification were compared, and were also related with HM fat and protein content and osmolality before and after fortification. Results: Phase 1: · A strong agreement was found between traditional methods’ and NIRA’s results (expressed as g/100 g of milk), both for fat and nitrogen content in term (mean fat content: NIRA=2.76; Gerber=2.76; mean nitrogen content: NIRA=1.88; Kjeldhal =1.92) and preterm (mean fat content: NIRA=3.56; Kjeldhal=3.52; mean nitrogen content: NIRA=1.91; Kjeldhal =1.89) mother’s milk. · Nitrogen content of the milk samples, measured by NIRA, ranged from 1.18 to 2.71 g/100 g of milk in preterm milk and from 1.48 to 2.47 in term milk; fat content ranged from 1.27 to 6.23 g/100 g of milk in preterm milk and from 1.01 to 6.01 g/100 g of milk in term milk. Phase 2: · An inverse correlation was found between naïve HM protein content and acid reflux index (RIpH: p=0.041, rho=-0.501). · After fortification, osmolality often exceeded the values recommended for infant feeds; furthermore, a statistically significant (p<.05) increase in non acid reflux indexes was observed. Conclusions: NIRA can be used as a fast, reliable and suitable tool for routine monitoring of macronutrient content of human milk. Protein content of naïve HM may influence acid GER in preterm infants. A standard fortification of HM may worsen non acid GER indexes and, due to the extreme variability in HM composition, may overcome both recommended protein intake and HM osmolality. Thus, an individualized fortification, based on the analysis of the composition of naïve HM, could optimize both nutrient intake and feeding tolerance.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Background The goal when resuscitating trauma patients is to achieve adequate tissue perfusion. One parameter of tissue perfusion is tissue oxygen saturation (StO2), as measured by near infrared spectroscopy. Using a commercially available device, we investigated whether clinically relevant blood loss of 500 ml in healthy volunteers can be detected by changes in StO2 after a standardized ischemic event. Methods We performed occlusion of the brachial artery for 3 minutes in 20 healthy female blood donors before and after blood donation. StO2 and total oxygenated tissue hemoglobin (O2Hb) were measured continuously at the thenar eminence. 10 healthy volunteers were assessed in the same way, to examine whether repeated vascular occlusion without blood donation exhibits time dependent effects. Results Blood donation caused a substantial decrease in systolic blood pressure, but did not affect resting StO2 and O2Hb values. No changes were measured in the blood donor group in the reaction to the vascular occlusion test, but in the control group there was an increase in the O2Hb rate of recovery during the reperfusion phase. Conclusion StO2 measured at the thenar eminence seems to be insensitive to blood loss of 500 ml in this setting. Probably blood loss greater than this might lead to detectable changes guiding the treating physician. The exact cut off for detectable changes and the time effect on repeated vascular occlusion tests should be explored further. Until now no such data exist.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Introduction: As a previous study revealed, arts speech therapy (AST) affects cardiorespiratory interaction [1]. The aim of the present study was to investigate whether AST also has effects on brain oxygenation and hemodynamics measured non-invasively using near-infrared spectroscopy (NIRS). Material and methods: NIRS measurements were performed on 17 subjects (8 men and 9 women, mean age: 35.6 ± 12.7 y) during AST. Each measurement lasted 35 min, comprising 8 min pre-baseline, 10 min recitation and 20 min post-baseline. For each subject, measurements were performed for three different AST recitation tasks (recitation of alliterative, hexameter and prose verse). Relative concentration changes of oxyhemoglobin (Δ[O2Hb]) and deoxyhemoglobin (Δ[HHb]) as well as the tissue oxygenation index (TOI) were measured using a Hamamatsu NIRO300 NIRS device and a sensor placed on the subjects forehead. Movement artifacts were removed using a novel method [2]. Statistical analysis (Wilcoxon test) was applied to the data to investigate (i) if the recitation causes changes in the median values and/or in the Mayer wave power spectral density (MW-PSD, range: 0.07–0.13 Hz) of Δ[O2Hb], Δ[HHb] or TOI, and (ii) if these changes vary between the 3 recitation forms. Results: For all three recitation styles a significant (p < 0.05) decrease in Δ[O2Hb] and TOI was found, indicating a decrease in blood flow. These decreases did not vary significantly between the three styles. MW-PSD increased significantly for Δ[O2Hb] when reciting the hexameter and prose verse, and for Δ[HHb] and TOI when reciting alliterations and hexameter, representing an increase in Mayer waves. The MW-PSD increase for Δ[O2Hb] was significantly larger for the hexameter verse compared to alliterative and prose verse Conclusion: The study showed that AST affects brain hemodynamics (oxygenation, blood flow and Mayer waves). Recitation caused a significant decrease in cerebral blood flow for all recitation styles as well as an increase in Mayer waves, particularly for the hexameter, which may indicate a sympathetic activation. References 1. D. Cysarz, D. von Bonin, H. Lackner, P. Heusser, M. Moser, H. Bettermann. Am J Physiol Heart Circ Physiol, 287 (2) (2004), pp. H579–H587 2. F. Scholkmann, S. Spichtig, T. Muehlemann, M. Wolf. Physiol Meas, 31 (5) (2010), pp. 649–662

Relevância:

100.00% 100.00%

Publicador:

Resumo:

We present a near-infrared (0.9-2.4 mu m) spectroscopic study of 73 field ultracool dwarfs having spectroscopic and/or kinematic evidence of youth (approximate to 10-300 Myr). Our sample is composed of 48 low-resolution (R approximate to 100) spectra and 41 moderate-resolution spectra (R greater than or similar to 750-2000). First, we establish a method for spectral typing M5-L7 dwarfs at near-IR wavelengths that is independent of gravity. We find that both visual and index-based classification in the near-IR provides consistent spectral types with optical spectral types, though with a small systematic offset in the case of visual classification at J and K band. Second, we examine features in the spectra of similar to 10 Myr ultracool dwarfs to define a set of gravity-sensitive indices based on FeH, VO, Ki, Nai, and H-band continuum shape. We then create an index-based method for classifying the gravities of M6-L5 dwarfs that provides consistent results with gravity classifications from optical spectroscopy. Our index-based classification can distinguish between young and dusty objects. Guided by the resulting classifications, we propose a set of low-gravity spectral standards for the near-IR. Finally, we estimate the ages corresponding to our gravity classifications.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Rapid bedside determination of cerebral blood pressure autoregulation (AR) may improve clinical utility. We tested the hypothesis that cerebral Hb oxygenation (HbDiff) and cerebral Hb volume (HbTotal) measured by near-infrared spectroscopy (NIRS) would correlate with cerebral blood flow (CBF) after single dose phenylephrine (PE). Critically ill patients requiring artificial ventilation and arterial lines were eligible. During rapid blood pressure rise induced by i.v. PE bolus, ΔHbDiff and ΔHbTotal were calculated by subtracting values at baseline (normotension) from values at peak blood pressure elevation (hypertension). With the aid of NIRS and bolus injection of indocyanine green, relative measures of CBF, called blood flow index (BFI), were determined during normotension and during hypertension. BFI during hypertension was expressed as percentage from BFI during normotension (BFI%). Autoregulation indices (ARIs) were calculated by dividing BFI%, ΔHbDiff, and ΔHbTotal by the concomitant change in blood pressure. In 24 patients (11 newborns and 13 children), significant correlations between BFI% and ΔHbDiff (or ΔHbTotal) were found. In addition, the associations between Hb-based ARI and BFI%-based ARI were significant with correlation coefficients of 0.73 (or 0.72). Rapid determination of dynamic AR with the aid of cerebral Hb signals and PE bolus seems to be reliable.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Arts speech therapy (AST) is a therapeutic method within complementary medicine and has been practiced for decades for various medical conditions. It comprises listening and the recitation of different forms of speech exercises under the guidance of a licensed speech therapist. The aim of our study was to noninvasively investigate whether different types of recitation influence hemodynamics and oxygenation in the brain and skeletal leg muscle using near-infrared spectroscopy (NIRS). Seventeen healthy volunteers (eight men and nine women, mean age ± standard deviation 35.6 ± 12.7 years) were enrolled in the study. Each subject was measured three times on different days with the different types of recitation: hexameter, alliteration, and prose verse. Before, during, and after recitation, relative concentration changes of oxyhemoglobin (Δ[O2Hb]), deoxyhemoglobin (Δ[HHb]), total hemoglobin (Δ[tHb]), and tissue oxygenation saturation (StO2) were measured in the brain and skeletal leg muscle using a NIRS device. The study was performed with a randomized crossover design. Significant concentration changes were found during recitation of all verses, with mainly a decrease in Δ[O2Hb] and ΔStO2 in the brain, and an increase in Δ[O2Hb] and Δ[tHb] in the leg muscle during recitation. After the recitations, significant changes were mainly increases of Δ[HHb] and Δ[tHb] in the calf muscle. The Mayer wave spectral power (MWP) was also significantly affected, i.e., mainly the MWP of the Δ[O2Hb] and Δ[tHb] increased in the brain during recitation of hexameter and prose verse. The changes in MWP were also significantly different between hexameter and alliteration, and hexameter and prose. Possible physiological explanations for these changes are discussed. A probable reason is a different effect of recitations on the sympathetic nervous system. In conclusion, these changes show that AST has relevant effects on the hemodynamics and oxygenation of the brain and muscle.