986 resultados para Mean values
Resumo:
Objective: The purpose of this study was to evaluate the flexural strength of repairs made with autopolymerising acrylic resin after different treatments of joint surfaces.Material and Methods: Fifty rectangular specimens were made with heat-polymerised acrylic resin and 40 were repaired with autopolymerising acrylic resin following joint surface treatments: group 1 (intact specimens), group 2 (chemical treatment: wetting with methyl-methacrylate for 180 s), group 3 (abraded with silicon carbide paper), group 4 (abraded and wetting with methyl-methacrylate for 180 s) and group 5 (without surface treatment). The flexural strength was measured by a three-point bending test using a universal testing machine with a 100 Kgf load cell in the centre of repair at 5 mm/min cross-head speed. All data were analysed using one-way ANOVA and Tukey HSD test for multiple comparisons (p < 0.05).Results: Among repaired specimens, groups 2 and 4 had 66.53 +/- 3.4 and 69.38 +/- 1.8 MPa mean values and were similar. These groups had superior flexural strength than groups 3 and 5 that were similar and had 54.11 +/- 3.4 and 51.24 +/- 2.8 MPa mean values, respectively. Group 1 had a mean value of 108.30 +/- 2.8 MPa being the highest result.Conclusion: It can be concluded that the treatment of the joint surfaces with methyl-methacrylate increases the flexural strength of denture base repairs, although the strength is still lower than that observed for the intact denture base resin. Abrasion with sandpaper was not able to influence the flexural strength of repaired denture bases.
Resumo:
Purpose: This in vitro study evaluated the dimensional accuracy of two impression techniques (tapered and splinted) with two stock trays (plastic and metal) for implant-supported prostheses. Materials and Methods: A master cast with four parallel abutment analogs and a passive framework were fabricated. Polyvinyl siloxane impression material was used for all impressions with two metal stock trays and two plastic stock trays (closed and open trays). Four groups (tapered plastic, splinted plastic, tapered metal, and splinted metal) and a control group (master cast) were tested (n = 5 for each group). After the framework was seated on each of the casts, one abutment screw was tightened, and the marginal gap between the abutment and framework on the other side was measured with a stereomicroscope. The measurements were analyzed with the Kruskal-Wallis one-way analysis of variance on ranks test followed by the Dunn method. Results: The mean values (+/- standard deviations) for the abutment/framework interface gaps were: master cast, 32 +/- 2 mu m; tapered metal, 44 +/- 10 mu m; splinted metal, 69 +/- 28 mu m; tapered plastic, 164 +/- 58 mu m; splinted plastic, 128 +/- 47 mu m. No significant difference was detected between the master cast, tapered metal, and splinted metal groups or between the tapered and splinted plastic groups. Conclusions: In this study, the rigidity of the metal stock tray ensured better results than the plastic stock tray for implant impressions with a high-viscosity impression material (putty). Statistically similar results were obtained using tapered impression copings and splinted squared impression copings. The tapered impression copings technique and splinted squared impression copings technique with a metal stock tray produced precise casts with no statistically significant difference in interface gaps compared to the master cast. INT J ORAL MAXILLOFAC IMPLANTS 2012;27:544-550.
Resumo:
OBJETIVO: Este estudo avaliou o escoamento do Acroseal, AH Plus, Endomethasone N, Sealapex e ActiV GP de acordo com a especificação ISO 6876/2001. METODOLOGIA: Um volume de 0,05 mL do cimento manipulado de acordo com as recomendações do fabricante foi colocado numa placa de vidro. Aos 180±5 s após o início da espatulação, uma segunda placa de vidro foi colocada sobre o cimento, seguida por um peso de massa de 100 g para fazer um total de 120±2 g. Dez minutos após o começo da manipulação o peso foi removido e o valor do diâmetro do disco de cimento foi mensurado. A média de 3 mensurações para cada cimento foi tomada como o escoamento do material. Os dados foram comparados estatisticamente pelos testes ANOVA e Tukey. RESULTADOS: Os escoamentos obtidos foram: Acroseal 21.,4 mm, AH Plus 22,72 mm, ActiV GP 24,90 mm, Endomethasone N 18,76 mm e Sealapex 25,15 mm. CONCLUSÃO: Apenas o Endomethasone N não se enquadrou na especificação ISO a qual requer que o cimento tenha um diâmetro não inferior a 20 mm. O Sealapex alcançou o melhor escoamento, mas não foi estatisticamente diferente do Activ GP e AH Plus (P>0,05).
Resumo:
Background and Objective: evaluate the adhesion of adhesive restorations with and without a base of resin-modified glass-ionomer cement (RMGIC) to dentin irradiated with Er:YAG laser.Study Design/Materials and Methods: Twenty-four human molar teeth were divided into 6 groups (n=4): G1) 37% Phosphoric acid (PA) + Adhesive system (Ad) + Composite resin (CR); G2) RMGIC + CR; G3) Laser (60mJ-5Hz-20s) + PA + Ad + CR; G4) Laser (60 mJ-5 Hz-20 s) + RMGIC + CR; G5) Laser (100mJ-5Hz-20s) + PA + Ad + CR; G6) Laser (100mJ-5Hz-20s) + RMGIC + CR. Teeth were prepared, restored and cut into specimens, according to the treatment proposed and to methodology for microtensile test. Data were submitted to ANOVA and Tukey statistical tests (alpha=5%).Results:. The mean values for adhesion (MPa) and standard deviation (+/- SD) were: G1) 26.30(+/- 4.50), G2) 5.34(+/- 2.87), G3) 21.16(+/- 6.01), G4) 5.22(+/- 1.52), G5) 22.23(+/- 4.98), G6) 5.25(+/- 3.08).Conclusion: the use of Er:YAG laser did not influence on the restorations adhesion.
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Purpose: To evaluate the root fracture strength of human single-rooted premolars restored with customized fiberglass post-core systems after fatigue simulation. Methods: 40 human premolars had their crowns cut and the root length was standardized to 13 mm. The teeth were endodontically treated and embedded in acrylic resin. The specimens were distributed into four groups (n=10) according to the restorative material used: prefabricated fiber post (PFP), PFP+accessory fiber posts (PFPa), PFP+unidirectional fiberglass (PFPf), and unidirectional fiberglass customized post (CP). All posts were luted using resin cement and the cores were built up with a resin composite. The samples were stored for 24 hours at 37 degrees C and 100% relative humidity and then submitted to mechanical cycling. The specimens were then compressive-loaded in a universal testing machine at a crosshead speed of 0.5 mm/minute until fracture. The failure patterns were analyzed and classified. Data was submitted to one-way ANOVA and Tukey's test (alpha= 0.05). Results: The mean values of maximum load (N) were: PFP - 811.4 +/- 124.3; PFPa - 729.2 +/- 157.2; PFPf - 747.5 +/- 204.7; CP - 762.4 +/- 110. Statistical differences were not observed among the groups. All groups showed favorable restorable failures. Fiberglass customized post did not show improved fracture resistance or differences in failure patterns when compared to prefabricated glass fiber posts. (Am J Dent 2012;25:35-38).
Resumo:
The Epiphany (TM) Sealer is a new dual-curing resin-based sealer and has been introduced as an alternative to gutta-percha and traditional root canal sealers. The canal filling is claimed to create a seal with the dentinal tubules within the root canal system producing a 'monoblock' effect between the sealer and dentinal tubules. Therefore, considering the possibility to incorporate the others adhesive systems, it is important to study the bond strength of the resulting cement. Forty-eight root mandibular canines were sectioned 8-mm below CEJ. The dentine discs were prepared using a tapered diamond bur and irrigated with 1% NaOCl and 17% EDTA. Previous the application Epiphany (TM) Sealer, the Epiphany (TM) Primer, AdheSE, and One Up Bond F were applied to the root canal walls. The LED and QTH (Quartz Tungsten Halogen) were used to photo-activation during 45 s with power density of 400 and 720 mW/cm(2), respectively. The specimens were performed on a universal testing machine at a cross-head speed of 1 mm/min until bond failure occurred. The force was recorded and the debonding values were used to calculate Push-out bond strength. The analysis of variance (ANOVA) and Tukey's post-hoc tests showed significant statistical differences (P < 0.05) to Epiphany (TM) Sealer/Epiphany (TM) Primer/QTH and EpiphanyTM Sealer/AdheSE/QTH, which had the highest mean values of bond strength. The efficiency of resin-based filling materials are dependent the type of light curing unit used including the power density, the polymerization characteristics of these resin-based filling materials, depending on the primer/adhesive used.
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Objective: Our goal was to investigate the surface temperature variations in the cervical region via infrared thermography, as well as the temperature within the pulp chamber via thermocouples, of mandibular incisors when subjected to dental bleaching using two different 35% hydrogen peroxide gels, red (HP) and green (HPM), when activated by halogen light (HL) and LED light.Background Data: Temperatures increases of more than 5.5 degrees C are considered to be potentially threatening to pulp vitality, while those higher than 10 degrees C can result in periodontal injury.Materials and Methods: Tooth samples were randomly divided into four groups (n = 10 each), according to the bleaching agent and catalyst light source used.Results: Mean values and standard deviations of the temperature increases inside the pulp chamber in the HL groups were 4.4 degrees +/- 2.1 degrees C with HP, and 4.5 degrees +/- 1.2 degrees C with HPM; whereas in the groups using LED light, they were 1.4 degrees +/- 0.3 degrees C for HP, and 1.5 degrees +/- 0.2 degrees C for HPM. For the root surfaces, the maximum temperature increases in the groups irradiated with HL were 6.5 degrees +/- 1.5 degrees C for HP, and 7.5 degrees +/- 1.1 degrees C with HPM; whereas in the groups irradiated with LED light, they were 2.8 degrees +/- 0.7 degrees C with HP, and 3 degrees +/- 0.8 degrees C with HPM. There were no statistically significant differences in pulp and surface temperature increases between the groups using different gels, although the mean temperature increases were significantly higher for the groups irradiated with HL when compared with those irradiated with the LED light (p < 0.05 with Tukey's test).Conclusion: LED light may be safe for periodontal and pulp tissue when using this method, but HL should be used with care.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
This study was carried out to evaluate the relationship of abomasal inflammatory cells and parasite-specific immunoglobulin A (IgA) in mucus, with the resistance to Haemonchus contortus infection in three breeds of sheep naturally infected with gastrointestinal nematodes. The breeds were the native Santa Ines sheep, and the European Suffolk and Ile de France breeds. Mast cells, eosinophils and globule leucocytes were enumerated in abomasal mucosa. Eosinophils within the sub-mucosa also were counted separately. Histamine concentration was estimated in abomasal tissue samples. Enzyme-linked immunosorbent assay was carried out in mucus samples to determine the level of IgA anti-H. contortus third and fifth instar. There were no significant differences among group means of these variables (P > 0.05). The correlation coefficients between fecal egg counts (FEC) x mast cells (r = -0.490; P < 0.05) and FEC x eosinophils in sub-mucosa (r = -0.714; P < 0.01) was significant in the Santa Ines sheep. In the Ile de France group, the correlation coefficients between globule leucocytes x FEC (r = -0.879; P < 0.001) and histamine x worm burden (r = -0.833; P < 0.01) were also significant. In the Santa Ines and Ile de France sheep, correlation coefficients between IgA anti-L3 x worm burden and IgA anti-L3 x FEC were negative. In general, inflammatory cells and IgA-parasite-specific in abomasum were inversely associated with H. contortus worm burden and FEC indicating that they may impair parasite development or fecundity in the three breeds of sheep. However, similar mean values of inflammatory cells and IgA were found in the resistant (Santa Ines) and in the susceptible (Suffolk and Ile de France) breeds of sheep. The enumeration of cells by histological assessment does not provide information on their functional activity, which may be different among breeds. Thus, the effect of breed on the functional activity of these and other inflammatory cells is an important area for further study. (c) 2004 Elsevier B.V. All rights reserved.
Resumo:
Breeds of sheep with resistance to nematode infection often display a reduced periparturient rise (PPR) in faecal egg counts (FEC) when compared with susceptible sheep. This trial was carried out to compare the resistance of Santa Ines, an indigenous Brazilian breed of sheep, and Ile de France ewes to natural infections by gastrointestinal nematodes, especially in the periparturient period. Twelve Santa lnes and 10 Ile de France ewes were estrus synchronized and then mated (December 2001). Lambing occurred from 30 April to 19 June 2002 and the lambs were weaned at 60 days of age. Faecal egg counts, packed cell volume (PCV), total plasma protein levels and peripheral eosinophils counts were determined from November 2001 to September 2002. To prevent deaths, individual treatment with anthelmintics was provided to ewes with FEC higher than 4000 eggs per gram (EPG) or with PCV lower than 21%. The percentage of Santa Ines ewes treated with anthelmintics was lower than that of Ile de France sheep. Eight of the 10 Ile de France ewes were treated, with one of them requiring four treatments, one requiring three treatments, and two requiring two treatments. The remaining four received a single treatment. In contrast, only 5 of the 12 Santa lnes ewes required treatment and for each this was done only once. The mean values of PCV were in the normal range in the Santa Ines ewes. In contrast, mean PCVs of Ile de France ewes reached a low of 24.5% in the second month after lambing and were significantly lower than Santa Ines 1 month before lambing (P < 0.05) and 2 months after lambing (P < 0.07). The mean plasma protein level was significantly lower in the Ile de France ewes in the second month after lambing (P < 0.01) coinciding with a reduction in PCV. The ewes of both breeds had high mean numbers of eosinophils in blood, which increased even further post-weaning when a marked reduction in FEC occurred. Haemonchus larvae were the most numerous genus in faecal cultures for both breeds followed by Trichostrongylus, Oesophagostomum and Cooperia. A periparturient rise in FEC was observed in both breeds. However, Santa Ines ewes showed a higher capacity to support the infection in an environment contaminated with large number of infective larvae of gastrointestinal nematodes. (C) 2004 Elsevier B.V. All rights reserved.
Resumo:
FUNDAMENTO: Ausência de estudos na literatura validando equações preditivas da frequência cardíaca máxima (FCmáx) em crianças e adolescentes. OBJETIVO: Analisar a validade das equações preditivas da FCmáx 220 - idade e 208 - (0,7 x idade) em meninos com idades entre 10 e 16 anos. MÉTODOS: Um teste progressivo de esforço máximo foi realizado em 69 meninos com idades entre 10 e 16 anos, aparentemente saudáveis e ativos. A velocidade inicial do teste foi de 9 km/h com incrementos de 1 km/h a cada três minutos. O teste foi mantido até a exaustão voluntária, considerando-se como FCmáx a maior frequência cardíaca atingida durante o teste. A FCmáx medida foi comparada com os valores preditos pelas equações 220 - idade e 208 - (0,7 x idade) através da ANOVA, medidas repetidas. Resultados: Os valores médios da FCmáx (bpm) foram: 200,2 ± 8,0 (medida), 207,4 ± 1,5 (220 - idade) e 199,2 ± 1,1 (208 - (0,7 x idade)). A FCmáx predita pela equação 220 - idade foi significantemente maior (p < 0,001) que a FCmáx medida e que a FCmáx predita pela equação (208 - (0,7 x idade)). A correlação entre a FCmáx medida e a idade não foi estatisticamente significativa (r = 0,096; p > 0,05). CONCLUSÃO: A equação 220 - idade superestimou a FCmáx medida e não se mostrou válida para essa população. A equação 208 - (0,7 x idade) se mostrou válida apresentando resultados bastante próximos da FCmáx medida. Estudos futuros estudos com amostras maiores poderão comprovar se a FCmáx não depende da idade para essa população, situação em que o valor constante de 200 bpm seria mais apropriado para a FCmáx.
Resumo:
Objective. The aim of this study was to analyze the relationships between the rate of perceived exertion (RPE) of a whole exercise session (RPE-S) and objective measures of exercise intensity during a karate training session.Methods. Eight well-trained karate athletes performed a single training session involving basic karate techniques and sparring. Heart rate (HR) was continuously monitored, while blood lactate ([lac]13) and rating of perceived exertion using the Borg's 6-20 scale were taken each 10-min during exercise. Athletes were also asked to rate their RPE-S using a modified CR-10 scale 30-min after exercise.Results. Significant relationships (P<0.05) were found between RPE-S and mean values of %HRmax (r(p) = 0.91), %HR reserve (r(p) = 0.87), [lac]b(r(p) = 0.96), and RPE (r(p) = 0.78) during the session, but not between RPE-S and the duration of exercise bout (r(s) = 0.28; P > 0.05). RPE-S was also significantly related (P < 0.05) to percentage of time sustained under ventilatory thresold (VT) (r(p) = 0.96), between VT and respiratory compensation point (RCP) (r(p) = 0.93) and above RCP (r(p) = 0.96).Conclusion. These results suggest RPE-S to be a valid tool for assessing interindividual variations in global exercise intensity during karate training. (C) 2010 Elsevier Masson SAS. All rights reserved.