960 resultados para Manifest refractive cylinder


Relevância:

20.00% 20.00%

Publicador:

Resumo:

A set of long period grating devices have been fabricated in photosensitive single mode fibre coated with a series of copper rings (period of 380μm, 50% duty cycle and length of 4cm). The long period gratings were inscribed with a uniform UV-laser exposure across the entire length of the copper ring patterned coating. The devices ranged in copper thickness from 0.5μm to 1.5μm. In addition, a control long period grating was fabricated in the same type of fibre with the same period for comparison. The refractive index and temperature spectral sensitivity of these devices were investigated and it was found that the index and temperature sensitivity is a function of the thickness of the copper rings, as supported by theoretical modelling. Furthermore, the index sensitivity of these devices in the 1.333 index region is greater than the control long period grating. The patterned 0.5μm coated long period grating gave a sensitivity of Δλ/Δn = -74 nm leading to a resolution of 1.4×10-3 compared to the control which had a sensitivity of Δλ/Δn = -32 nm with a resolution of 3.2×10-3 in the index region of 1.320 to 1.380 (aqueous solution regime). This demonstrates a two fold increase in the sensitivity. This novel fibre long period grating device shows potential for increasing the resolution of measurements of the index of aqueous solutions.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A dual-parameter optical sensor has been realized by UV-writing a long-period and a Bragg grating structure in D-fiber. The hybrid configuration permits the detection of the temperature from the latter and measuring the external refractive index from the former responses, respectively. The employment of the D-fiber allows as effective modification and enhancement of the device sensitivity by cladding etching. The grating sensor has been used to measure the concentrations of aqueous sugar solutions, demonstrating the potential capability to detect concentration changes as small as 0.01%.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose - To assess clinical outcomes and subjective experience after bilateral implantation of a diffractive trifocal intraocular lens (IOL). Setting - Midland Eye Institute, Solihull, United Kingdom. Design - Cohort study. Methods - Patients had bilateral implantation of Finevision trifocal IOLs. Uncorrected distance visual acuity, corrected distance visual acuity (CDVA), and manifest refraction were measured 2 months postoperatively. Defocus curves were assessed under photopic and mesopic conditions over a range of +1.50 to -4.00 diopters (D) in 0.50 D steps. Contrast sensitivity function was assessed under photopic conditions. Halometry was used to measure the angular size of monocular and binocular photopic scotomas arising from a glare source. Patient satisfaction with uncorrected near vision was assessed using the Near Activity Visual Questionnaire (NAVQ). Results - The mean monocular CDVA was 0.08 logMAR ± 0.08 (SD) and the mean binocular CDVA, 0.06 ± 0.08 logMAR. Defocus curve testing showed an extended range of clear vision from +1.00 to -2.50 D defocus, with a significant difference in acuity between photopic conditions and mesopic conditions at -1.50 D defocus only. Photopic contrast sensitivity was significantly better binocularly than monocularly at all spatial frequencies. Halometry showed a glare scotoma of a mean size similar to that in previous studies of multifocal and accommodating IOLs; there were no subjective complaints of dysphotopsia. The mean NAVQ Rasch score for satisfaction with near vision was 15.9 ± 10.7 logits. Conclusions - The trifocal IOL implanted binocularly produced good distance visual acuity and near and intermediate visual function. Patients were very satisfied with their uncorrected near vision.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We report here the fabrication, charaterisation and refractive index sensing of two microchanneled chirped fiber Bragg gratings (MCFBGs) with different channel sizes (~550µm and ~1000µm). The chirped grating structures were UV-inscribed in optical fibre and the microchannels were created in the middle of the CFBGs by femtosecond (fs) laser assisted chemical etching method. The creation of microchannels in the CFBG structures gives an access to the external index liquid, thus inducing refractive index (RI) sensitivity to the structure. In comparison with previously reported FBG based RI sensors, for which the cladding layers usually were removed, the MCFBGs represent a more ideal solution for robust devices as the microchannel will not degrade the structure strength. The two MCFBGs were spectrally charaterised for their RI and temperature responses and both gratings exhibited unique thermal and RI sensitivities, which may be utilised for implementation of bio-chemical sensors with capability to eliminate temperature crosssensitivity.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

De-inking sludge can be converted into useful forms of energy to provide economic and environmental benefits. In this study, pyrolysis oil produced from de-inking sludge through an intermediate pyrolysis technique was blended with biodiesel derived from waste cooking oil, and tested in a multi-cylinder indirect injection type CI engine. The physical and chemical properties of pyrolysis oil and its blends (20 and 30 vol.%) were measured and compared with those of fossil diesel and pure biodiesel (B100). Full engine power was achieved with both blends, and very little difference in engine performance and emission results were observed between 20% and 30% blends. At full engine load, the brake specific fuel consumption on a volume basis was around 6% higher for the blends when compared to fossil diesel. The brake thermal efficiencies were about 3-6% lower than biodiesel and were similar to fossil diesel. Exhaust gas emissions of the blends contained 4% higher CO2 and 6-12% lower NOx, as compared to fossil diesel. At full load, CO emissions of the blends were decreased by 5-10 times. The cylinder gas pressure diagram showed stable engine operation with the 20% blend, but indicated minor knocking with 30% blend. Peak cylinder pressure of the 30% blend was about 5-6% higher compared to fossil diesel. At full load, the peak burn rate of combustion from the 30% blend was about 26% and 12% higher than fossil diesel and biodiesel respectively. In comparison to fossil diesel the combustion duration was decreased for both blends; for 30% blend at full load, the duration was almost 12% lower. The study concludes that up to 20% blend of de-inking sludge pyrolysis oil with biodiesel can be used in an indirect injection CI engine without adding any ignition additives or surfactants.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Renewable alternatives such as biofuels and optimisation of the engine operating parameters can enhance engine performance and reduce emissions. The temperature of the engine coolant is known to have significant influence on engine performance and emissions. Whereas much existing literature describes the effects of coolant temperature in engines using fossil derived fuels, very few studies have investigated these effects when biofuel is used as an alternative fuel. Jatropha oil is a non-edible biofuel which can substitute fossil diesel for compression ignition (CI) engine use. However, due to the high viscosity of Jatropha oil, technique such as transesterification, preheating the oil, mixing with other fuel is recommended for improved combustion and reduced emissions. In this study, Jatropha oil was blended separately with ethanol and butanol, at ratios of 80:20 and 70:30. The fuel properties of all four blends were measured and compared with diesel and jatropha oil. It was found that the 80% jatropha oil + 20% butanol blend was the most suitable alternative, as its properties were closest to that of diesel. A 2 cylinder Yanmar engine was used; the cooling water temperature was varied between 50°C and 95°C. In general, it was found that when the temperature of the cooling water was increased, the combustion process enhanced for both diesel and Jatropha-Butanol blend. The CO2 emissions for both diesel and biofuel blend were observed to increase with temperature. As a result CO, O2 and lambda values were observed to decrease when cooling water temperature increased. When the engine was operated using diesel, NOX emissions correlated in an opposite manner to smoke opacity; however, when the biofuel blend was used, NOX emissions and smoke opacity correlated in an identical manner. The brake thermal efficiencies were found to increase slightly as the temperature was increased. In contrast, for all fuels, the volumetric efficiency was observed to decrease as the coolant temperature was increased. Brake specific fuel consumption was observed to decrease as the temperature was increased and was higher on average when the biofuel was used, in comparison to diesel. The study concludes that the effects of engine coolant temperature on engine performance and emission characteristics differ between biofuel blend and fossil diesel operation. The coolant temperature needs to be optimised depending on the type of biofuel for optimum engine performance and reduced emissions.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We report the implementation of a low-cost high-resolution WDM interrogation system operating around 800nm region with bandwidth up to 60 nm and resolution of 13 pm by utilising a tilted fibre Bragg grating as an out-coupling device and a CCD-array detector. The system has been evaluated for interrogating fibre Bragg grating based strain, temperature sensors, giving sensitivities of 0.6 pm/µe and 5.6 pm/°C which are in good agreement with previously reported values. Furthermore, the system has been utilised to detect refractive index change of sample liquids, demonstrating a capability of measuring index change as small as 10-5.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A multicore fibre (MCF) sensor to measure the radial deformation of a compliant cylinder under compression is presented. The sensor is connectorised and need not be permanently bonded to the test object. A differential measurement technique using FBGs written into the MCF makes the sensor temperature insensitive. FBG measurement of axial strain of a cylinder under compression is also reported.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: Changes in refractive error are well documented over the typical human lifespan. However, a relatively neglected period of investigation appears to be during the late fourth decade; this is at the incipient phase of presbyopia (IP), where the amplitude of accommodation is much reduced and approaches the level where a first reading addition is anticipated. Significantly, informal clinical observation has suggested a low incidence of an unexpected abrupt increase in myopia during IP. Methods: We investigated this alleged myopic shift retrospectively by mapping the longitudinal refraction histories of normally-sighted 35-44years old British White patients previously examined in routine optometric practice. The refractive trends in the right eyes of healthy myopic subjects (spherical equivalent refraction, SER =-0.50D: N=39) were analysed relative to that point at which a first near dioptric addition was considered to be clinically useful. Results: A refractive change was evident in some subjects during IP; viz, an abrupt increase in myopic SER of between -0.50 and -0.75D. These individuals (N=8) represented 20% of the study population of myopic incipient presbyopes. Beyond the pivotal point of the first near addition the longitudinal refraction stabilized in these subjects. In contrast, and as the extent of the available longitudinal data would permit, the remaining myopic eyes maintained an approximately stable refractive trend throughout IP and beyond. Conclusions: The anatomical or physiological basis of this specific late (non-developmental) abrupt myopic refractive change is an intriguing issue. Axial (vitreous chamber elongation), corneal (contour) and lenticular (profile and index) power bases, alone or in concert, might be considered candidates for this hitherto unexplored refractive phenomenon. Although necessarily obtained under conventional conditions of central (0deg) fixation, our data might also be a reflection of the recent recognition of the possible influence of the peripheral refraction upon the axial error. Consideration of this material provides an impetus for further research, including ocular biometry, a reappraisal of ciliary zonular functional anatomy, renewed investigation of the AC/A ratio, and the extent of a centripetal refractive influence on myopia development. © 2011 The College of Optometrists.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

DUE TO COPYRIGHT RESTRICTIONS ONLY AVAILABLE FOR CONSULTATION AT ASTON UNIVERSITY LIBRARY AND INFORMATION SERVICES WITH PRIOR ARRANGEMENT

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A compact scheme for simultaneous temperature and surrounding refractive index (SRI) measurement using two long-period gratings (LPGs) of different periods inscribed side-by-side in a single piece of a double-cladding fibre is presented. One of the LPGs is sensitive to both SRI and temperature, whilst the second is sensitive to temperature only.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We present a compact scheme for simultaneous temperature and surrounding refractive index (SRI) measurement using two long period gratings (LPGs) of different periods inscribed side-by-side in a single piece of a double-cladding fibre. One of the LPGs is sensitive to both SRI and temperature changes whilst the second is SRI-insensitive but shows spectral shift with temperature changes. In addition, we show that a resonance peak of the SRI-insensitive LPG can be designed to appear in the EDFA wavelength region with potential use for gain flattening applications.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The microchannelled chirped fibre Bragg grating (MCFBG) was fabricated using femtosecond laser processing and HF-etching. Intrinsical refractive-index sensitivity induced by the microchannel makes MCFBGs ideal for biochemical sensing.