944 resultados para Load factor design


Relevância:

30.00% 30.00%

Publicador:

Resumo:

In this thesis, the purpose was to find the cost distribution of the screen dryer and the largest cost factors. The hot section of the screen dryer was revealed as the biggest cost factor, so composing new cost efficient solutions were directed to it. DFMA (Design for Manufacture and Assembly) was chosen to help the design process. DFMA is a product design strategy developed for taking manufacturing and assembly costs into account at the early stages of the design process. In the theory part of the thesis, other methods of economical design and tools needed for estimating manufacturing costs are introduced. In the empirical part, the hot section of the screen dryer was divided into sub-assemblies and their manufacturing costs were estimated. The design propositions were directed to the self-manufactured assemblies and parts. The new manufacturing costs were calculated for the developed propositions. Lastly, the most cost efficient solutions were summarized. The savings on the self-manufactured assemblies were about 40 %, which was about 13 % of the combined total costs of the hot section.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

In this work is proposed a solid phase preconcentration system of Co2+ ions and its posterior determination by GFAAS in which fractional factorial design and response surface methodology (RSM) were used for optimization of the variables associated with preconcentration system performance. The method is based on cobalt extraction as a complex Co2+-PAN (1:2) in a mini-column of polyurethane foam (PUF) impregnated with 1-(2-pyridylazo)-naphthol (PAN) followed by elution with HCl solution and its determination by GFAAS. The chemical and flow variables studied were pH, buffer concentration, eluent concentration and preconcentration and elution flow rates. Results obtained from fractional factorial design 2(5-1) showed that only the variables pH, buffer concentration and interaction (pH X buffer concentration) based on analysis of variance (ANOVA) were statistically significant at 95% confidence level. Under optimised conditions, the method provided an enrichment factor of 11.6 fold with limit of detection and quantification of 38 and 130 ng L-1, respectively, and linear range varying from 0.13 to 10 µg L-1. The precision (n = 9) assessed by relative standard deviation (RSD) was respectively 5.18 and 2.87% for 0.3 and 3.0 µg L-1 cobalt concentrations.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Rautaruukki Oyj:n uusi Ruukki double grade S420MH/S355J2H -rakenneputki yhdistää putkilajien S420MH ja S355J2H ominaisuudet. Eurocode 3:n suunnitteluohjeiden mukaan Ruukki double graden käyttöön on sovellettava lujuusluokan S420 mukaista hitsien mitoitusta ja rakenneputkiliitosten staattista mitoituskestävyyttä alentavaa varmuuskerrointa, kun halutaan hyödyntää lujuusluokan S420 ominaisuudet Ruukki double gradea käytettäessä. Tässä työssä tutkittiin S420-lujuusluokkaa vastaavien suunnittelumääräysten soveltamistarvetta Ruukki double grade -rakenneputken käyttöön. Työn tavoitteena oli arvioida Ruukki double grade -rakenneputkesta hitsaamalla valmistetun X-liitoksen kestävyyden ja muodonmuutoskyvyn riittävyys, kun hitsit mitoitettiin S355-lujuusluokkaa vastaavien Eurocode 3:n suunnitteluohjeiden mukaisesti. X-liitosten kestävyyttä ja muodonmuutoskykyä tutkittiin kokeellisesti -40 C lämpötilassa suoritettujen laboratoriokokeiden avulla sekä analyyttisen laskennan ja elementtimenetelmän keinoin. Kestävyyden riittävyyttä arvioitiin vertaamalla laboratoriokokeista saatuja liitosten kestävyyksiä Eurocode 3:n ja myötöviivateorian mukaisiin kestävyyksiin. Elementtimenetelmän ja laboratoriokokeen pohjalta piirrettyjä liitoksen voima-siirtymäkuvaajia vertailtiin keskenään, kun elementtimalli analysoitiin eri materiaalimalleilla. Lisäksi verrattiin elementtimallin voima-venymäkuvaajia liitoksen venymäliuskan arvoihin. Kaikki koesarjan S355-lujuusluokan mukaisilla hitsin a-mitoilla valmistetut liitokset täyttivät kestävyydelle ja muodonmuutoskyvylle asetetut vaatimukset. Täten tämän koesarjan perusteella ei ollut tarpeellista soveltaa S420-lujuusluokan mukaista hitsien mitoitusta ja staattista mitoituskestävyyttä alentavaa varmuuslukua Ruukki double grade -rakenneputkeen. Elementtimenetelmästä ja laboratoriokokeesta saadut liitoksen voima-siirtymäkuvaajat vastasivat hyvin toisiaan. Sen sijaan elementtimallin voima-venymä-kuvaajat eivät vastanneet venymäliuskojen mittausdataa kovin hyvin.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Tässä työssä tutkittiin Ruukin valmistamista lujista Optim 700 MC Plus sekä Optim 700 QL teräksistä tehtyjen hitsattujen palkkirakenteiden vikasietoisuutta sekä murtumiskäyttäytymistä laboratoriossa suoritettujen täyden mittakaavan kokeiden avulla. Koerakenteet suunniteltiin siten, että rakenteen kylmämuovauksen sekä hitsauksen vaikutukset yhdessä rakenteen geometrian vaikutuksen kanssa heikentävät rakenteen murtumissitkeyttä rakenteeseen tehdyn teräväkärkisen alkusärön tasossa. Suunnitellussa koesarjassa varioidaan testauslämpötilan lisäksi hitsauksen lämmöntuontia sekä koerakenteeseen tehtävän alkusärön kokoa. Tässä työssä tavoitteena oli yleisesti esittää menettely hitsatun säröllisen teräsrakenteen kestävyyden arviointia varten. Optim 700 MC Plus teräksestä tehdyn koerakenteen käyttäytymistä tutkittiin laskennallisesti murtumismekaniikan avulla. Laadittujen FEM - mallien avulla laskettiin rakenteen murtumisparametrien arvot kummallekin tutkittavalle teräkselle. Optim 700 MC Plus materiaalista valmistetuille koerakenteen säröalueen rakennedetaljia vastaavalle koekappaleille suoritettiin murtumissitkeyskokeita. Murtumissitkeyskokeista saatujen tulosten avulla pystyttiin kuvaamaan täyden mittakaavan koerakenteessa olevan särön murtumiskäyttäytymistä mitoitusmenetelmissä. Koerakenteelle laskettiin tässä työssä kriittisen särökoon ja sitä vastaavan kuorman arvot perustuen rakenteen oletettuun hauraaseen, epästabiiliin sitkeään sekä plastiseen murtumiskäyttäytymiseen. Tässä työssä testattiin molemmista tutkittavista materiaaleista valmistetut täyden mittakaavan koerakenteet -40 °C lämpötilassa. Molemmat testatut rakenteet käyttäytyvät mitattujen siirtymätulosten perusteella melko hauraasti. Optim 700 MC Plus materiaalille saatujen laskentatulosten voidaan todeta testatun koekappaleen perusteella soveltuvan hauraasti käyttäytyvän rakenteen mitoitukseen.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Direct-driven permanent magnet synchronous generator is one of the most promising topologies for megawatt-range wind power applications. The rotational speed of the direct-driven generator is very low compared with the traditional electrical machines. The low rotational speed requires high torque to produce megawatt-range power. The special features of the direct-driven generators caused by the low speed and high torque are discussed in this doctoral thesis. Low speed and high torque set high demands on the torque quality. The cogging torque and the load torque ripple must be as low as possible to prevent mechanical failures. In this doctoral thesis, various methods to improve the torque quality are compared with each other. The rotor surface shaping, magnet skew, magnet shaping, and the asymmetrical placement of magnets and stator slots are studied not only by means of torque quality, but also the effects on the electromagnetic performance and manufacturability of the machine are discussed. The heat transfer of the direct-driven generator must be designed to handle the copper losses of the stator winding carrying high current density and to keep the temperature of the magnets low enough. The cooling system of the direct-driven generator applying the doubly radial air cooling with numerous radial cooling ducts was modeled with a lumped-parameter-based thermal network. The performance of the cooling system was discussed during the steady and transient states. The effect of the number and width of radial cooling ducts was explored. The large number of radial cooling ducts drastically increases the impact of the stack end area effects, because the stator stack consists of numerous substacks. The effects of the radial cooling ducts on the effective axial length of the machine were studied by analyzing the crosssection of the machine in the axial direction. The method to compensate the magnet end area leakage was considered. The effect of the cooling ducts and the stack end area effects on the no-load voltages and inductances of the machine were explored by using numerical analysis tools based on the three-dimensional finite element method. The electrical efficiency of the permanent magnet machine with different control methods was estimated analytically over the whole speed and torque range. The electrical efficiencies achieved with the most common control methods were compared with each other. The stator voltage increase caused by the armature reaction was analyzed. The effect of inductance saturation as a function of load current was implemented to the analytical efficiency calculation.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This doctoral thesis presents a study on the development of a liquid-cooled frame salient pole permanent-magnet-exited traction machine for a four-wheel-driven electric car. The emphasis of the thesis is put on a radial flux machine design in order to achieve a light-weight machine structure for traction applications. The design features combine electromagnetic and thermal design methods, because traction machine operation does not have a strict operating point. Arbitrary load cycles and the flexible supply require special attention in the design process. It is shown that accurate modelling of the machine magnetic state is essential for high-performance operation. The saturation effect related to the cross-saturation has to be taken carefully into account in order to achieve the desired operation. Two prototype machines have been designed and built for testing: one totally enclosed machine with a special magnet module pole arrangement and another through-ventilated machine with a more traditional embedded magnet structure. Both structures are built with magnetically salient structures in order to increase the torque production capability with the reluctance torque component. Both machine structures show potential for traction usage. However, the traditional embedded magnet design turns out to be mechanically the more secure one of these two machine options.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

In order to grow, cities are increasingly competing for attention, jobs, investments, visitors, residents and significant events. Cities need to come up with creative solutions to keep up with the competition; they ought to become creative cities. Attracting talented and diverse inhabitants is a key factor in developing a creative city, which on is characterized by openness, tolerance, vibrancy and diversity. Along the need for renewed city images city brand building has become popular. Helsinki is the World Design Capital 2012 (WDC 2012) and this mega-event presents a meaningful opportunity for the city to broadcast itself globally. The purpose of this study is to evaluate how Helsinki brands itself as a creative city through an international mega-event. The sub-aims are to: 1) Map the factors behind the creative city and their relation to the city of Helsinki, 2) Describe the city branding process, 3) Evaluate the role of the Helsinki World Design Capital 2012 mega-event in Helsinki’s creative city brand building. First, the theory discusses the concept of the creative city that has gained growing attention during the past decade. Then, the city branding process is described and the benefits of hosting a mega-event are presented. Finally, co-branding a city and a mega-event in order to generate maximum benefit from the mega-event, is reviewed. This is a qualitative research for which data was collected through three face-to-face interviews, the World Design Capital 2012 bid, Helsinki’s economic development strategy, a consulting firm’s research report on the case city and web-pages. The research reveals that Helsinki has shown interest in the creative city discussion. The terminology around the concept is however approached carefully. Helsinki fits many of the creative city characteristics and recognizes its flaws for which improvement strategies have been planned. Bottlenecks keeping the city from promoting a more open mind were mainly revealed in its organizational structures. Helsinki has no official brand strategy; nonetheless pressure to develop one is present. The World Design Capital 2012 mega-event is seen as a meaningful stepping board to strengthen Helsinki’s identity and image, and start thinking about a city brand. The brand strategies of the mega-event support the values and virtues of the city itself, which enables benefits of co-branding introduces in the theory part. Helsinki has no official brand and doesn’t call itself a creative city, however this study shows signs of the city taking steps towards building a creative city brand with the help of the Helsinki World Design Capital 2012 mega-event.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Permanent magnet generators (PMG) represent the cutting edge technology in modern wind mills. The efficiency remains high (over 90%) at partial loads. To improve the machine efficiency even further, every aspect of machine losses has to be analyzed. Additional losses are often given as a certain percentage without providing any detailed information about the actual calculation process; meanwhile, there are many design-dependent losses that have an effect on the total amount of additional losses and that have to be taken into consideration. Additional losses are most often eddy current losses in different parts of the machine. These losses are usually difficult to calculate in the design process. In this doctoral thesis, some additional losses are identified and modeled. Further, suggestions on how to minimize the losses are given. Iron losses can differ significantly between the measured no-load values and the loss values under load. In addition, with embedded magnet rotors, the quadrature-axis armature reaction adds losses to the stator iron by manipulating the harmonic content of the flux. It was, therefore, re-evaluated that in salient pole machines, to minimize the losses and the loss difference between the no-load and load operation, the flux density has to be kept below 1.5 T in the stator yoke, which is the traditional guideline for machine designers. Eddy current losses may occur in the end-winding area and in the support structure of the machine, that is, in the finger plate and the clamping ring. With construction steel, these losses account for 0.08% of the input power of the machine. These losses can be reduced almost to zero by using nonmagnetic stainless steel. In addition, the machine housing may be subjected to eddy current losses if the flux density exceeds 1.5 T in the stator yoke. Winding losses can rise rapidly when high frequencies and 10–15 mm high conductors are used. In general, minimizing the winding losses is simple. For example, it can be done by dividing the conductor into transposed subconductors. However, this comes with the expense of an increase in the DC resistance. In the doctoral thesis, a new method is presented to minimize the winding losses by applying a litz wire with noninsulated strands. The construction is the same as in a normal litz wire but the insulation between the subconductors has been left out. The idea is that the connection is kept weak to prevent harmful eddy currents from flowing. Moreover, the analytical solution for calculating the AC resistance factor of the litz-wire is supplemented by including an end-winding resistance in the analytical solution. A simple measurement device is developed to measure the AC resistance in the windings. In the case of a litz-wire with originally noninsulated strands, vacuum pressure impregnation (VPI) is used to insulate the subconductors. In one of the two cases studied, the VPI affected the AC resistance factor, but in the other case, it did not have any effect. However, more research is needed to determine the effect of the VPI on litz-wire with noninsulated strands. An empirical model is developed to calculate the AC resistance factor of a single-layer formwound winding. The model includes the end-winding length and the number of strands and turns. The end winding includes the circulating current (eddy currents that are traveling through the whole winding between parallel strands) and the main current. The end-winding length also affects the total AC resistance factor.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The capacity of beams is a very important factor in the study of durability of structures and structural members. The capacity of a high-strength steel I-beam made of S960 QC was investigated in this study. The investigation included assessment of the service limits and ultimate limits of the steel beam. The thesis was done according to European standards for steel structures, Eurocode 3. An analytical method was used to determine the throat thickness, deformation, elastic and plastic moment capacities as well as the fatigue life of the beam. The results of the analytical method were compared with those obtained by Finite Element Analysis (FEA). Elastic moment capacity obtained by the analytical method was 172 kNm. FEA and the analytical method predicted the maximum lateral-torsional buckling (LTB) capacity in the range of 90-93 kNm and the probability of failure as a result of LTB is estimated to be 50%. The lateral buckling capacity meant that the I-beam can carry a safe load of 300 kN instead of the initial load of 600 kN. The beam is liable to fail shortly after exceeding the elastic moment capacity. Based on results in of the different approaches, it was noted that FEA predicted higher deformation values on the load-deformation curve than the analytical results. However, both FEA and the analytical methods predicted identical results for nominal stress range and moment capacities. Fatigue life was estimated to be in the range of 53000-64000 cycles for bending stress range using crack propagation equation and strength-life approach. As Eurocode 3 is limited to steel grades up to S690, results for S960 must be verified with experimental data and appropriate design rules.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Tässä diplomityössä on tutkittu tehollisen lovijännityksen menetelmän soveltuvuutta ultralujien terästen korkealaatuisten hitsien väsymismitoitukseen. International Institute of Welding suosittelee käyttämään elementtimenetelmässä hitsin rajaviivoilla sekä juuressa fiktiivistä 1 mm pyöristystä, jonka avulla tehollinen lovijännitys määritetään. Kaikille liitostyypeille sovelletaan samaa, kaltevuudeltaan m = 3 olevaa SN-käyrää, jolloin maksimipääjännitystä vastaava väsymisluokka FAT saa arvon 225. Nykyisiä mitoitusohjeita on pidetty kuitenkin liian konservatiivisina, etenkin jos kyseessä on suurilujuuksisesta teräksestä valmistettu korkealaatuinen hitsi. Rajaviivalla vaikuttavaa lovijännitystä on tutkittu mallintamalla liitokset FEMAP – elementtimenetelmäohjelmalla varioimalla rajaviivan pyöristystä. Elementtimenetelmän tuloksia on verrattu analyyttisiin loven muotoluvun laskentakaavoihin. Tutkittavana on ollut Ruukin Optim 960 QC sekä Optim 1100 QC – teräksistä valmistettuja koesauvoja. Koesauvat on valmistettu sekä koestettu pääasiassa Lappeenrannan teknillisen yliopiston teräsrakenteiden laboratoriossa. Tutkittavat koesauvat ovat olleet kuormaa kantamattomia ristiliitoksia sekä päittäisliitoksia. Suurin osa koesauvoista on väsytetty käyttämällä jännityssuhdetta R < 0,11. Koesauvat on jaoteltu jännityssuhteen sekä liitostyypin mukaan. Kaikkien koekappaleiden karakteristiseksi väsymisluokan arvoksi on määritetty FAT 200. Alle 0,11 jännityssuhteella väsytettyjen koekappaleiden karakteristinen väsymisluokka on FAT 230 ja isoilla jännityssuhteilla väsytettyjen FAT 126. Tulosten perusteella nykyiset mitoitusohjeet eivät ole liian konservatiivisia. Väsymisluokkaa FAT 225 voidaan käyttää väsymislaskennassa, mikäli rakenteen kuormitusten suhde on alle 0,1. Isoilla jännityssuhteilla koestettujen koekappaleiden lukumäärä on ollut pieni, joten niiden mitoitukselle ei voida antaa tarkkoja ohjeita.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Parin viime vuosikymmenen aikana on kehitetty huomattavasti entistä lujempia teräslaatuja, joiden käyttö ei kuitenkaan ole yleistynyt läheskään samaan tahtiin. Korkeamman hinnan lisäksi yksi merkittävä syy tähän on, että suunnittelijoilla ei usein ole riittäviä tietoja siitä, millaisissa tilanteissa lujemman teräslaadun käytöstä on merkittävää hyötyä. Tilannetta ei myöskään helpota se, että käytössä olevat standardit eivät tarjoa lainkaan ohjeistusta kaikkein lujimpien, myötörajaltaan yli 700MPa terästen käyttöön ja mitoitukseen. Tässä työssä pyritään tarjoamaan suunnittelijalle ohjeita ja nyrkkisääntöjä sopivan lujuusluokan ja profiilin valintaan sekä yleisesti lujempien teräslaatujen käyttöön. Lujemman teräslaadun käytöllä voidaan keventää suunniteltavaa rakennetta ja saada aikaan huomattavia painonsäästöjä. Usein ongelmaksi nousevat kuitenkin stabiiliuskriteerit, sillä teräksen lommahduskestävyys määräytyy suuresti sen lujuusluokasta siten, että mitä lujempaa teräs on, sitä helpommin se lommahtaa. Kun tämä yhdistetään siihen, että lujempaa terästä käytettäessä rakenteesta tulee optimoituna muutenkin pienempi ja kevyempi, kasvaa näiden kahden asian yhteisvaikutuksena kantokyvyn mukaan mitoitetun rakenteen taipuma korkeampiin lujuusluokkiin edetessä hyvin nopeasti sallittujen rajojen yli. Työssä etsitään siksi keinoja sopivan kompromissin löytämiseksi lujuuden ja jäykkyyden välille. Koska muotoilulla ja poikkileikkauksella on suuri merkitys sekä taipuman että stabiliteetin kannalta, tutkitaan erilaisia poikkileikkausvaihtoehtoja ja etsitään optimaalista poikkileikkausta taivutuspalkille matemaattisen optimointimallin avulla. Kun eri poikkileikkausvaihtoehdot on käsitelty ja optimoitu taivutuksen suhteen, tutkitaan poikkileikkauksia myös muissa kuormitustapauksissa. Huomattavan raskaan laskentatyön takia apuna käytetään Matlab-ohjelmistoa itse optimointiin ja Femap-ohjelmaa muiden kuormitustapausten tutkimiseen ja tulosten verifioitiin.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Traction motor design significantly differs from industrial machine design. The starting point is the load cycle instead of the steady-state rated operation point. The speed of the motor varies from zero to very high speeds. At low speeds, heavy overloading is used for starting, and the field-weakening region also plays an important role. Finding a suitable fieldweakening point is one of the important design targets. At the lowest speeds, a high torque output is desired, and all current reserves of the supplying converter unit are used to achieve the torque. In this paper, a 110-kW 2.5-p.u. starting torque and a maximum 2.5-p.u. speed permanent-magnet traction motor will be studied. The field-weakening point is altered by varying the number of winding turns of machine. One design is selected for prototyping. Theoretical results are verified by measurements.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The objective of the present study was to determine the prevalence of electrolyte disturbances in AIDS patients developing acute kidney injury in the hospital setting, as well as to determine whether such disturbances constitute a risk factor for nephrotoxic and ischemic injury. A prospective, observational cohort study was carried out. Hospitalized AIDS patients were evaluated for age; gender; coinfection with hepatitis; diabetes mellitus; hypertension; time since HIV seroconversion; CD4 count; HIV viral load; proteinuria; serum levels of creatinine, urea, sodium, potassium and magnesium; antiretroviral use; nephrotoxic drug use; sepsis; intensive care unit (ICU) admission, and the need for dialysis. Each of these characteristics was correlated with the development of acute kidney injury, with recovery of renal function and with survival. Fifty-four patients developed acute kidney injury: 72% were males, 59% had been HIV-infected for >5 years, 72% had CD4 counts <200 cells/mm³, 87% developed electrolyte disturbances, 33% recovered renal function, and 56% survived. ICU admission, dialysis, sepsis and hypomagnesemia were all significantly associated with nonrecovery of renal function and with mortality. Nonrecovery of renal function was significantly associated with hypomagnesemia, as was mortality in the multivariate analysis. The risks for nonrecovery of renal function and for death were 6.94 and 6.92 times greater, respectively, for patients with hypomagnesemia. In hospitalized AIDS patients, hypomagnesemia is a risk factor for nonrecovery of renal function and for in-hospital mortality. To determine whether hypomagnesemia is a determinant or simply a marker of critical illness, further studies involving magnesium supplementation in AIDS patients are warranted.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Common variants of the transcription factor 7-like 2 (TCF7L2) gene have been found to be associated with type 2 diabetes in different ethnic groups. The Japanese-Brazilian population has one of the highest prevalence rates of diabetes. Therefore, the aim of the present study was to assess whether two single-nucleotide polymorphisms (SNPs) of TCF7L2, rs7903146 and rs12255372, could predict the development of glucose intolerance in Japanese-Brazilians. In a population-based 7-year prospective study, we genotyped 222 individuals (72 males and 150 females, aged 56.2 ± 10.5 years) with normal glucose tolerance at baseline. In the study population, we found that the minor allele frequency was 0.05 for SNP rs7903146 and 0.03 for SNP rs12255372. No significant allele or genotype association with glucose intolerance incidence was found for either SNP. Haplotypes were constructed with these two SNPs and three haplotypes were defined: CG (frequency: 0.94), TT (frequency = 0.027) and TG (frequency = 0.026). None of the haplotypes provided evidence for association with the incidence of glucose intolerance. Despite no associations between incidence of glucose intolerance and SNPs of the TCF7L2 gene in Japanese-Brazilians, we found that carriers of the CT genotype for rs7903146 had significantly lower insulin levels 2 h after a 75-g glucose load than carriers of the CC genotype. In conclusion, in Japanese-Brazilians, a population with a high prevalence of type 2 diabetes, common TCF7L2 variants did not make major contributions to the incidence of glucose tolerance abnormalities.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

At present, one of the main concerns of green network is to minimize the power consumption of network infrastructure. Surveys show that, the highest amount of power is consumed by the network devices during its runtime. However to control this power consumption it is important to know which factors has highest impact on this matter. This paper is focused on the measurement and modeling the power consumption of an Ethernet switch during its runtime considering various types of input parameters with all possible combinations. For the experiment, three input parameters are chosen. They are bandwidth, link load and number of connections. The output to be measured is the power consumption of the Ethernet switch. Due to the uncertain power consuming pattern of the Ethernet switch a fully-comprehensive experimental evaluation would require an unfeasible and cumbersome experimental phase. Because of that, design of experiment (DoE) method has been applied to obtain adequate information on the effects of each input parameters on the power consumption. The whole work consists of three parts. In the first part a test bed is planned with input parameters and the power consumption of the switch is measured. The second part is about generating a mathematical model with the help of design of experiment tools. This model can be used for measuring precise power consumption in different scenario and also pinpoint the parameters with higher influence in power consumption. And in the last part, the mathematical model is evaluated by comparing with the experimental values.