974 resultados para Flame throwers


Relevância:

10.00% 10.00%

Publicador:

Resumo:

This paper describes the evaluation of a new method of sample preparation using a cold finger system with continuous water flow for rice analysis by flame atomic absorption spectrometry. The limits of detection for Cu, Fe, Mn and Zn for the proposed method were 0.36, 1.84, 2.12 and 0.16 mg kg-1, respectively. The RSDs were lower than 6.0% for all elements and the CRM analyzed showed values with 95% agreement. The proposed method is simple and safe for the proposed objective and does not require the use of mixtures of acid or special equipment for sample preparation.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The type A gasoline samples were analyzed by gas chromatography with flame ionization detector (GC-FID) which allowed quantifying and classifying of the various compounds into different classes of hydrocarbons. Several physicochemical parameters were evaluated according to the official methods in order to compare the results obtained against the limits established by the Agência Nacional de Petróleo, Gás Natural e Biocombustíveis (ANP, 2011). Additionally, principal component analysis (PCA) was applied to discriminate the samples studied, which revealed the separation of four groups according to their chemical composition determined in samples collected from the eight fuel distributors in the State of Pará.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Simple and sensitive procedures for the extraction/preconcentration of molybdenum based on vortex-assisted solidified floating organic drop microextraction (VA-SFODME) and cloud point combined with flame absorption atomic spectrometry (FAAS) and discrete nebulization were developed. The influence of the discrete nebulization on the sensitivity of the molybdenum preconcentration processes was studied. An injection volume of 200 µL resulted in a lower relative standard deviation with both preconcentration procedures. Enrichment factors of 31 and 67 and limits of detection of 25 and 5 µg L-1 were obtained for cloud point and VA-SFODME, respectively. The developed procedures were applied to the determination of Mo in mineral water and multivitamin samples.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Three bacterial strains were isolated from the activated sludge system of petroleum refinery wastewater, identified by partial sequencing of 16S rDNA, and classified as Acinetobacter genomospecies 3, Bacillus pumilus, and Bacillus flexus. The degradation efficiency of aromatic hydrocarbons was evaluated by gas chromatography with a flame ionization detector. In a mineral medium containing anthracene and phenanthrene and the consortium of microorganisms, the removal efficiency was 96% and 99%, respectively, after 30 days. The good rate of hydrocarbon degradation proves the operational efficiency of the microbial consortium in treating effluents containing these compounds.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

In the present work, a simple and rapid ligand-less, in situ, surfactant-based solid phase extraction for the preconcentration of copper in water samples was developed. In this method, a cationic surfactant (n-dodecyltrimethylammonium bromide) was dissolved in an aqueous sample followed by the addition of an appropriate ion-pairing agent (ClO4-). Due to the interaction between the surfactant and ion-pairing agent, solid particles were formed and subsequently used for the adsorption of Cu(OH)2 and CuI. After centrifugation, the sediment was dissolved in 1.0 mL of 1 mol L-1 HNO3 in ethanol and aspirated directly into the flame atomic absorption spectrometer. In order to obtain the optimum conditions, several parameters affecting the performance of the LL-ISS-SPE, including the volumes of DTAB, KClO4, and KI, pH, and potentially interfering ions, were optimized. It was found that KI and phosphate buffer solution (pH = 9) could extract more than 95% of copper ions. The amount of copper ions in the water samples varied from 3.2 to 4.8 ng mL-1, with relative standard deviations of 98.5%-103%. The determination of copper in water samples was linear over a concentration range of 0.5-200.0 ng mL-1. The limit of detection (3Sb/m) was 0.1 ng mL-1 with an enrichment factor of 38.7. The accuracy of the developed method was verified by the determination of copper in two certified reference materials, producing satisfactory results.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

In this study, the percentage content of free steroid in oils, fats and biodiesel was analyzed. For this, the saponification reaction on a microscale was used, and this procedure for extraction of unsaponifiable fraction was studied in several experimental steps. After the process of saponification, the unsaponifiable fraction was analyzed by gas chromatography with flame ionization detector, where all steroids present in each oil, fat and biodiesel were identified and their contents determined and compared to their respective biodiesel. A reduction in unsaponifiable fraction of each oil and fat and its biodiesel was noted, as well as a reduction in the content of free steroids. The results showed that, compared to the sedimentation problem of steroids in biodiesel, some raw materials, such as chicken fat and babassu oil may be promising because they have low content and high reduction percentages of steroids when converted to biodiesel.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Flame atomic absorption spectrometry (FAAS) and inductively coupled plasma optical emission spectrometry (ICP OES) are widely used in academic institutions and laboratories for quality control to analyze inorganic elements in samples. However, these techniques have been observed to underperform in sample nebulization processes. Most of the samples processed through nebulization system are discarded, producing large volumes of waste. This study reports the treatment and reuse of the waste produced from ICP OES technique in a laboratory of analytical research at the Universidade Federal do Ceará, Brazil. The treatment of the waste was performed by the precipitation of elements using (NH4)2CO3. Subsequently, the supernatant solution can be discarded in accordance with CONAMA 430/2011. The precipitate produced from the treatment of residues can be reused as a potential sample in undergraduate qualitative analytical chemistry lab classes, providing students the opportunity to test a real sample.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The chemical composition of the essential oil and hydrolates of Campomanesia viatoris Landrum were investigated by gas chromatography/mass spectrometry (GC/MS) and a GC flame ionization detector (GC-FID). The major constituents were tasmanone (70.50, essential oil; 74.73%, hydrolate), flavesone (12.77, essential oil; 12.24%, hydrolate) and agglomerone (6.79, essential oil; 10.84%, hydrolate). Tasmonone was isolated and its structure was characterized by spectrometric analysis, specifically 1D and 2D nuclear magnetic resonance (NMR) and mass spectrometry (MS). These findings supports the quimiotaxonomic relationship with Campomanesia and Eucalyptus genera.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The leaf essential oils of Eugenia lutescens Cambess andEugenia langsdorffii O. Berg, collected in the rainy (RS) and dry seasons (DS), were extracted by hydrodistillation and then characterized by a gas chromatography-flame ionization detector and a gas chromatography-mass spectrometer. The potential acaricidal activity and oviposition deterrence of these oils were evaluated against Tetranychus urticae . The oil yields were higher in the RS for E. lutescens, while those forE. langsdorffii were higher in the DS. α-Pinene and β-pinene were determined to be the major constituents of the oils fromE. lutescens, while bicyclogermacrene, spathulenol, and β-caryophyllene predominated in E. langsdorffii . Seasonal variations in the oils were primarily related to chemical diversity, and E. lutescens was more affected than was E. langsdorffii . The E. langsdorffii oil collected in the DS was most toxic to the spider mite, while the oils of E. lutescens and E. langsdorffii collected in the RS drastically reduced its egg quantities. This study successfully determined the periods of greater oil production and acaricidal activity.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A fast gas chromatography with a flame ionisation detector (GC-FID) method for the simultaneous analysis of methyl palmitate (C16:0), stearate (C18:0), oleate (C18:1), linoleate (C18:2) and linolenate (C18:3) in biodiesel samples was proposed. The analysis was conducted in a customised ionic-liquid stationary-phase capillary, SLB-IL 111, with a length of 14 m, an internal diameter of 0.10 mm, a film thickness of 0.08 µm and operated isothermally at 160 °C using hydrogen as the carrier gas at a rate of 50 cm s-1 in run time about 3 min. Once methyl myristate (C14:0) is present lower than 0.5% m/m in real samples it was used as an internal standard. The method was successful applied to monitoring basic and acidic catalysis transesterification reactions of vegetable oils such as soybean, canola, corn, sunflower and those used in frying process.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Tässä diplomityössä kehitettiin mittaus- ja analyysimenetelmät suojavaatemateriaalien kemikaaliläpäisevyyden testaamiseksi sekä neste- että kaasumaisella metyylisalisylaatilla. Kehitystyö tehtiin standardin SFS-EN ISO 6529 pohjalta. Tämä standardi kuvaa kuitenkin varsin yleisellä tasolla suojavaatemateriaalien kemikaaliläpäisevyyden testimenetelmät, eikä se ole mikään tarkka työohje. Näytteenotto- ja analyysimenetelmät joudutaan siis valitsemaan sekä validoimaan jokaiselle kemikaalille erikseen, tässä tapauksessa metyylisalisylaatille. Työn tarkoituksena oli kehittää toimivat menetelmät ja laitteistot siten, että olisi mahdollista suorittaa metyylisalisylaatin määritys on-line mittauksena läpäisytestauksessa. Läpäisytestaustoiminnan nopeuttamiseksi työssä myös suunniteltiin ja rakennettiin laitteistot kolmen rinnakkaisen testikennon yhdenaikaista testausta varten sekä kaasumaisen että nestemäisen metyylisalisylaatin ollessa testikemikaalina. Havaittiin, että UV/VIS-spektrofotometri varustettuna läpivirtauskyvetillä ja näyteenottopumpulla on toimiva ja käyttökelpoinen analyysimenetelmä metyylisalisylaatin määrittämiseen nesteistä on-line mittauksena läpäisyn testauksessa. Kaasumaisen metyylisalisylaatin tapauksessa määritysmenetelmänä päädyttiin käyttämään kokonaishiilivetyanalysaattoria, joka on varustettu liekki-ionisaatiodetektorilla. Molemmissa tapauksissa saatiin aikaan toimivat ja on-line mittauksiin kykenevät näytteenotto- ja määritysmenetelmät, joilla loppukäyttäjä voi suorittaa laajempaa läpäisytestausta.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Diplomityössä tutkittiin kromatografian, elektroforeesin ja spektrometrian käyttöä ympäristövesianalytiikassa. Kokeellisessa osassa analysoitiin Saimaan Vesi- ja Ympäristötutkimus Oy:n keräämistä kaatopaikka-, jätevesi-, pohjavesi-, vesistö-, uimahalli-, yksityiskaivo-, poreallas- ja suovesinäytteistä epäorgaaniset anionit (F-, Cl-, Br-, NO3-, NO2- SO42-ja PO42-) sekä ionikromatografilla että kapillaarielektroforeesilla. Näytteet on kerätty Saimaan alueen ympäristökunnista. Kapillaarielektroforeesilla analysoitiin lisäksi tiosulfaatti. Liekkiatomiabsorptio-spektrometrilla analysoitiin Cu, Fe, Na ja Al. Natriumia löytyi jokaisesta vesinäytteestä. Pohjavesistä ei löytynyt rautaa eikä alumiinia ja kuparipitoisuudet olivat alle määritysrajan. Vesistövesistä kahdessa näytteessä oli alle määritysrajan olevia rautapitoisuuksia. Muissa näytteissä ei rautaa ollut. Suovesistä kuparia löytyi hyvin pieniä määriä ja yhdestä näytteestä alumiinia alle määritysrajan. Kaatopaikkavesissä kuparipitoisuudet sekä kolmessa näytteessä alumiinipitoisuudet olivat alle määritysrajan. Jätevesistä oletettiin löytyvän suuria määriä typpispesieksiä ja fosforia. Niitä kuitenkin esiintyi isoissa pitoisuuksissa vain suovesinäytteissä. Jätevesinäytteet sisälsivät bromidia, nitraattia ja fluoridia jopa yli 140 mg/l. Kapillaarielektroforeesilla ja ionikromatografilla mitatut anionipitoisuudet korreloivat hyvin toisiaan. Kontaminoituja vesiä löytyi pohja-, kaatopaikka-, jäte- ja vesistövesistä sekä uima-altaan terapiaaltaan vedestä.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Silica gel chemically modified with 2-Aminotiazole groups, abbreviated as SiAT, was used for preconcentration of copper, zinc, nickel and iron from kerosene, normally used as a engine fuel for airplanes. Surface characteristics and surface area of the silica gel were obtained before and after chemical modification using FT-IR, Kjeldhal and surface area analysis (B.E.T.). The retention and recovery of the analyte elements were studied by applying batch and column techniques. The experimental parameters, such as shaking time in batch technique, flow rate and concentration of the eluent (HCl- 0.25-2.00 mol L-1) and the amount of silica, on retention and elution, have been investigated. Detection limits of the method for copper, iron, nickel and zinc are 0.77, 2.92, 1.73 and 0.097 mg L-1, respectively. The sorption-desorption of the studied metal ions made possible the development of a preconcentration method for metal ions at trace level in kerosene using flame AAS for their quantification.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Tässä työssä tutkittiin Stora Enso Oyj:n Heinolan Flutingtehtaan voimalaitos- ja jätevesien seuranta-analyysimenetelmien kehittämistä. Käytössä olevia menetelmiä vertailtiin vaihtoehtoisiin uusiin menetelmiin, jotka perustuvat erotustekniikoihin ja automaatioon. Flutingtehtaalla nykyisin käytössä olevat analyysimenetelmät perustuvat suurelta osin standardimäärityksiin, joissa käytetään pääasiassa titrausta. Määritykset vievät paljon aikaa, koska titraukset toteutetaan manuaalisesti. Titrausten päätepisteet tulkitaan esim. indikaattorin värinmuutoksella ja saostamalla, joten määritysten tarkkuus vaihtelee. Kokeellisessa osassa Flutingtehtaan puhtaista voimalaitosvesistä yhdistetty sekoitenäyte analysoitiin kahdella ionikromatografilla, liekkiatomiabsorptiospektrometrillä ja kapillaarielektroforeesilla. Yksittäisiä näytteitä ei tutkittu. Lisäksi vesilaboratoriossa määritettävistä jätevesistä yhdistettiin sekoitenäyte, joka analysoitiin kapillaarielektroforeesilla. Samat sekoitenäytteet analysoitiin myös nykyisillä menetelmillä tehtaan vesilaboratoriossa. Tulokset osoittivat, että kokeellisessa osassa tutkitut menetelmät soveltuvat sekoitenäytteen perusteella hyvin vesilaboratoriossa käytössä oleviin kuukausianalyyseihin. Automaattisella näytteensyötöllä varustettuna kaikki kolme kokeellisessa osassa tutkittua menetelmää ovat yksikertaisia käyttää ja ne nopeuttavat analyysejä. Päivittäisiä titrausanalyysejä voidaan tehostaa ja nopeuttaa automaation avulla. Erotustekniikoilla esimerkiksi typpi voidaan määrittää kokonaistyppenä, mutta myös komponentteinaan eli ammoniakkina, nitraattina ja nitriittinä. Lisäksi samalla erotuksella voidaan määrittää useita alkali- ja maa-alkalimetalleja sekä raskas-metalleja toistomittauksilla. Menetelmän käyttöalue on laajempi erotustekniikoilla kuin perinteisillä liuoskemian mittauksilla. Erotustekniikoilla tunnistetaan helposti määritysten oikeellisuus detektointimahdollisuuksien monipuolisuuden vuoksi.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A flow-injection system with sample and reagent addition by the synchronous merging zones approach for calcium determination in milk by flame AAS is proposed. Main parameters were optimized using a factorial design with central point. The optimum conditions were 2.5% (m/v) for La concentration, 8 mL min-1 for the carrier flow-rate, 20 cm for coiled reactor and 250 ìL for sample volume. Different sample preparation procedures were evaluated such as dilution in water or acid and microwave-assisted decomposition using concentrated or diluted acids. The optimized flow system was applied to determine Ca in eleven commercial milk samples and two standard reference materials diluted in water. Similar calcium levels were encountered comparing the results obtained by the proposed method (dilution in water) with those obtained using microwave-oven digestion. Results obtained in two standard reference materials were in agreement at 95% confidence level with those certified. Recoveries of spiked samples were in the 93% - 116% range. Relative standard deviation (n = 12) was < 5.4% and the sample throughput was 150 measurements per hour, corresponding to a consumption of 250 µL of sample and 6.25 mg La per determination.