999 resultados para Fire stations -- Buildings -- Llansa (Spain)
Resumo:
Disaster management is one of the most relevant application fields of wireless sensor networks. In this application, the role of the sensor network usually consists of obtaining a representation or a model of a physical phenomenon spreading through the affected area. In this work we focus on forest firefighting operations, proposing three fully distributed ways for approximating the actual shape of the fire. In the simplest approach, a circular burnt area is assumed around each node that has detected the fire and the union of these circles gives the overall fire’s shape. However, as this approach makes an intensive use of the wireless sensor network resources, we have proposed to incorporate two in-network aggregation techniques, which do not require considering the complete set of fire detections. The first technique models the fire by means of a complex shape composed of multiple convex hulls representing different burning areas, while the second technique uses a set of arbitrary polygons. Performance evaluation of realistic fire models on computer simulations reveals that the method based on arbitrary polygons obtains an improvement of 20% in terms of accuracy of the fire shape approximation, reducing the overhead in-network resources to 10% in the best case.
Resumo:
In this work a forest fire detection solution using small autonomous aerial vehicles is proposed. The FALCOS unmanned aerial vehicle developed for remote-monitoring purposes is described. This is a small size UAV with onboard vision processing and autonomous flight capabilities. A set of custom developed navigation sensors was developed for the vehicle. Fire detection is performed through the use of low cost digital cameras and near-infrared sensors. Test results for navigation and ignition detection in real scenario are presented.
Resumo:
Every year forest fires consume large areas, being a major concern in many countries like Australia, United States and Mediterranean Basin European Countries (e.g., Portugal, Spain, Italy and Greece). Understanding patterns of such events, in terms of size and spatiotemporal distributions, may help to take measures beforehand in view of possible hazards and decide strategies of fire prevention, detection and suppression. Traditional statistical tools have been used to study forest fires. Nevertheless, those tools might not be able to capture the main features of fires complex dynamics and to model fire behaviour [1]. Forest fires size-frequency distributions unveil long range correlations and long memory characteristics, which are typical of fractional order systems [2]. Those complex correlations are characterized by self-similarity and absence of characteristic length-scale, meaning that forest fires exhibit power-law (PL) behaviour. Forest fires have also been proved to exhibit time-clustering phenomena, with timescales of the order of few days [3]. In this paper, we study forest fires in the perspective of dynamical systems and fractional calculus (FC). Public domain forest fires catalogues, containing data of events occurred in Portugal, in the period 1980 up to 2011, are considered. The data is analysed in an annual basis, modelling the occurrences as sequences of Dirac impulses. The frequency spectra of such signals are determined using Fourier transforms, and approximated through PL trendlines. The PL parameters are then used to unveil the fractional-order dynamics characteristics of the data. To complement the analysis, correlation indices are used to compare and find possible relationships among the data. It is shown that the used approach can be useful to expose hidden patterns not captured by traditional tools.
Resumo:
The aim of this study was to undertake a comparative analysis of the practices and information behaviour of European information users who visit information units specialising in European information in Portugal and Spain. The study used a quantitative methodology based on a questionnaire containing closed questions and one open question. The questions covered the general sociological profile of the respondents and their use of European Document Centres, in addition to analysing aspects associated with information behaviour relating to European themes. The study therefore examined data on the preferred means and sources for accessing European information, types of documents and the subjects investigated most. The use of European databases and the Internet to access material on Europe was also studied, together with the reasons which users considered made it easy or difficult to access European information, and the aspects they valued most in accessing this information. The questionnaire was administered in European Document Centres in 2008 and 2010.
Resumo:
A very important part of the globally produced energy is consumed in buildings, being an important share frequently used in the HVAC systems. These ones are increasing both in performance and in complexity, taking advantage from the use of the recent advances in mechanical and power electronic devices, particularly in the speed variation field. However the improved efficiency only occurs while the HVAC unit is working in the conditions specified by the manufacturer, otherwise the energy consumption raises to values considerably higher than the nominal ones. The adequate maintenance enforces the system to run on its nominal performance and the contrary has undesirable impact both in the performance and in the system expected life time. Therefore, HVAC field maintenance assumes a very important role in the global building sustainability concept. This work presents some results of an incorrect use of HVAC and the associated electric energy overconsumption that can assume values 50% higher than those that occur when the installation is operated according to the adequate maintenance plan.
Resumo:
In order to decrease the risk of severe wildfire, prescribed fire has recently been adopted in Portugal and elsewhere in the Mediterranean as a major tool for reducing the fuel load instead of manual or mechanical removal of vegetation. There has been some research into its impact on soils in shrublands and grasslands, but to date little research has been conducted in forested areas in the region. As a result, the impact of prescribed fire on the physico-chemical soil characteristics of forest soils has been assumed to be minimal, but this has not been demonstrated. In this study, we present the results of a monitoring campaign of a detailed pre- and post-prescribed fire assessment of soil properties in a long-unburnt P. pinaster plantation, NW Portugal. The soil characteristics examined were pH, total porosity, bulk density, moisture content, organic matter content and litter/ash quantity. The results show that there was no significant impact on the measured soil properties, the only effect being confined to minor changes in the upper 1 cm of soil. We conclude that provided the fire is carried out according to strict guidelines in P. pinaster forest, a minimal impact on soil properties can be expected.
Resumo:
5th International Conference of Fire Effects on Soil Properties
Resumo:
The Azores archipelago is a zone with a vast cultural heritage, presenting a building stock mainly constructed in traditional stone masonry. It is known that this type of construction exhibits poor behaviour under seismic excitations; however it is extensively used in seismic prone areas, such as this case. The 9th of July of 1998 earthquake was the last seismic event in the islands, leaving many traditional stone constructions severely damaged or totally destroyed. This scenario led to an effort by the local government of improving the seismic resistance of these constructions, with the application of several reinforcement techniques. This work aims to study some of the most used reinforcement schemes after the 1998 earthquake, and to assess their effectiveness in the mitigation of the construction’s seismic vulnerability. A brief evaluation of the cost versus benefit of these retrofitting techniques is also made, seeking to identify those that are most suitable for each building typology. Thus, it was sought to analyze the case of real structures with different geometrical and physical characteristics, by establishing a comparison between the seismic performance of reinforced and non-reinforced structures. The first section contains the analysis of a total of six reinforcement scenarios for each building chosen. Using the recorded 1998 earthquake accelerograms, a linear time-history analysis was performed for each reinforcement scenario. A comparison was then established between the maximum displacements, inter-storey drift and maximum stress obtained, in order to evaluate the global seismic response of each reinforced structure. In the second part of the work, the examination of the performance obtained in the previous section, in relation to the cost of implementing each reinforcement technique, allowed to draw conclusions concerning the viability of implementing each reinforcement method, based on the book value of the buildings in study.
Resumo:
A Segurança Contra Incêndios em Edifícios representa uma parte importante nos projetos de engenharia, uma vez que tem de ser analisada e implementada desde o início da construção. O principal objetivo é oferecer confiança aos utilizadores dos edifícios, aos seus bens e sistemas, sempre de acordo com a lei. Em qualquer tipo de edifício é iminente a capacidade de, por diversos motivos e circunstâncias, se iniciar um incêndio. O que se pretende com toda a regulamentação e matéria sobre a Segurança Contra Incêndios em Edifícios é a aplicação de sistemas de deteção, prevenção e extinção de incêndios, conseguindo, deste modo, reduzir os seus efeitos negativos. Este relatório de estágio apresenta, de um modo geral, a importância da Segurança Contra Incêndios em Edifícios atualmente nas construções, quais as principais regras neste âmbito, bem como a apresentação de todos os equipamentos e sistemas que fazem parte dos sistemas de SCIE. O presente relatório culmina com a vertente prática que consiste na descrição de casos acompanhados durante os meses de estágio, vistorias efetuadas e ensaios de incêndio. Os fenómenos inerentes a um alarme de incêndio serão descritos e comprovados em situações reais de simulação.
Resumo:
Dissertation submitted in partial fulfillment of the requirements for the Degree of Master of Science in Geospatial Technologies.
Resumo:
Dissertation submitted in partial fulfillment of the requirements for the Degree of Master of Science in Geospatial Technologies.
Resumo:
Dissertation submitted in partial fulfillment of the requirements for the Degree of Master of Science in Geospatial Technologies.
Resumo:
Dissertation submitted in partial fulfillment of the requirements for the Degree of Master of Science in Geospatial Technologies.
Resumo:
Dissertation submitted in partial fulfillment of the requirements for the Degree of Master of Science in Geospatial Technologies.
Resumo:
Background: Sexually transmitted infections (STIs) present a major public health concern and a global cause of illness in both industrialized and developing countries. Portugal is no exception, with an increasing incidence of STIs, and one of the highest prevalences of HIV in Europe. Reduced risk perceptions among men who have sex with men (MSM) and a consequent high-risk sexual behaviour have been increasingly reported throughout the world. Objectives: To characterize the population of MSM attending a STI clinic in Lisbon, and to assess practice of condom use among these patients. Methods: Records of all MSM patients who attended the STI clinic from 2008 to 2011 were reviewed to study demographic characteristics, sexual behaviours, and leading diagnoses in this population. Results: Of a total of 389 patients, 108 MSM were identified (27.8%), mostly Portuguese men with high school or above education, aged 17 to 61 years (medium age of 32.4 years). More than half of the patients (52.8%) reported more than one sexual partner in the past 6 months (19.4% more than 5 partners), and only a third consistently used condom. A history of sex with sex workers was mentioned in 9.2%. The most prevalent diagnoses were syphilis (45.6%) and condylomata acuminata (38.9%). The prevalence of HIV infection in this subgroup of patients was significantly higher than in the rest of the population (47.2% vs. 14.9%). Inconsistent condom use increased over the years (36.4% in 2008, 66.7% in 2011), and these patients revealed a greater number of sexual partners than condom users (60.4% vs. 50%). However, 38.9% of condom users presented with early syphilis, suggesting inadequate use of this barrier method. Among HIV patients, almost half of them (49%) had sex with more than one partner in the previous six months, and 47.1% did not use the condom during all sexual practices. Of these, 45.8% were not on antiretroviral therapy. Conclusions: High-risk sexual behaviours (inconsistent use of condom and multiple partners) are increasingly prevalent in this MSM subpopulation, despite previous educational programmes. The high incidence of risk behaviours among HIV infected patients is particularly worrisome, and must be addressed with innovative interventions and population-based prevention strategies.